Skip to main content
Top
Published in: International Orthopaedics 2/2011

01-02-2011 | Original Paper

The dual mobility socket concept: experience with 668 cases

Authors: Claude Vielpeau, Benoit Lebel, Ludovic Ardouin, Gilles Burdin, Christine Lautridou

Published in: International Orthopaedics | Issue 2/2011

Login to get access

Abstract

Long-term results of a retrospective series of primary arthroplasty with the original cementless dual mobility socket (A) and the midterm results with the second generation (B) are reported. In series A (follow-up 16.5 years) 437 total hip arthroplasties (THA) were included and in series B (follow-up five years) 231 hips. The 15-year survival rate was 84.4 ± 4.5% (revision for any reason as endpoint); 30 hips (6.8%) were revised for aseptic loosening. Five THA were revised for dislocation: two early and three after ten years or more. With the second generation socket neither dislocation nor revision for mechanical reasons were observed. The survival rate was 99.6 ± 0.4% (revision for any reason). The prevalence of revision for dislocation was very low in our series. This concept does not avoid wear and aseptic loosening, especially in young active patients, but the long-term stability has been confirmed. Dual mobility can be recommended for patients over 70 years of age and for younger patients with high risk of dislocation.
Literature
1.
go back to reference Adam P, Philippot R, Dargai F, Coumert S, Farizon F, Fessy MH (2005) Double mobilité et luxation intra prothétique. Rev Chir Orthop Reparatrice Appar Mot 91(6 Suppl):185 Adam P, Philippot R, Dargai F, Coumert S, Farizon F, Fessy MH (2005) Double mobilité et luxation intra prothétique. Rev Chir Orthop Reparatrice Appar Mot 91(6 Suppl):185
2.
go back to reference Adam P, Farizon F, Fessy MH (2005) Analyse de surface après explantation de 40 cupules rétentives à double mobilité. Rev Chir Orthop Reparatrice Appar Mot 91:627–636PubMed Adam P, Farizon F, Fessy MH (2005) Analyse de surface après explantation de 40 cupules rétentives à double mobilité. Rev Chir Orthop Reparatrice Appar Mot 91:627–636PubMed
3.
go back to reference Aubriot JH, Lesimple P, Leclercq S (1993) Etude du cotyle non scellé de Bousquet dans cent prothèses totales de hanche hybrides. Recul moyen de 5 ans. Acta Orthop Belg 59(Suppl 1):267–271PubMed Aubriot JH, Lesimple P, Leclercq S (1993) Etude du cotyle non scellé de Bousquet dans cent prothèses totales de hanche hybrides. Recul moyen de 5 ans. Acta Orthop Belg 59(Suppl 1):267–271PubMed
4.
go back to reference Avedikian J, Soyer J, Dumez JF, Muller A, Pries P, Clarac JP (1996) L’implant cotyloïdien dans l’arthroplastie totale de Charnley. Revue de 309 dossiers avec un recul minimum de 15 ans. Rev Chir Orthop Reparatrice Appar Mot 82(2):116–124PubMed Avedikian J, Soyer J, Dumez JF, Muller A, Pries P, Clarac JP (1996) L’implant cotyloïdien dans l’arthroplastie totale de Charnley. Revue de 309 dossiers avec un recul minimum de 15 ans. Rev Chir Orthop Reparatrice Appar Mot 82(2):116–124PubMed
6.
go back to reference Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2004) The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86-A(1):9–14PubMed Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2004) The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86-A(1):9–14PubMed
7.
go back to reference Callaghan JJ, Heithoff BE, Goetz DD, Sullivan PM, Pedersen DR, Johnston RC (2001) Prevention of dislocation after hip arthroplasty: lessons from long-term followup. Clin Orthop Relat Res 393:157–162CrossRefPubMed Callaghan JJ, Heithoff BE, Goetz DD, Sullivan PM, Pedersen DR, Johnston RC (2001) Prevention of dislocation after hip arthroplasty: lessons from long-term followup. Clin Orthop Relat Res 393:157–162CrossRefPubMed
8.
go back to reference Callaghan JJ, Templeton JE, Liu SS, Petersen DR, Goetz DD, Sullivan PM et al (2004) Results of Charnley total hip arthroplasty at a minimum of thirty years. A concise follow-up of a previous report. J Bone Joint Surg Am 86-A(4):690–695PubMed Callaghan JJ, Templeton JE, Liu SS, Petersen DR, Goetz DD, Sullivan PM et al (2004) Results of Charnley total hip arthroplasty at a minimum of thirty years. A concise follow-up of a previous report. J Bone Joint Surg Am 86-A(4):690–695PubMed
9.
go back to reference Epinette JA, Manley MT, D’Antonio JA, Edidin AA, Capello WN (2003) A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: clinical, radiographic and survivorship analyses with comparison to the literature. J Arthroplasty 18(2):140–148CrossRefPubMed Epinette JA, Manley MT, D’Antonio JA, Edidin AA, Capello WN (2003) A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: clinical, radiographic and survivorship analyses with comparison to the literature. J Arthroplasty 18(2):140–148CrossRefPubMed
10.
go back to reference Guyen O, Pibarot V, Vaz G, Chevillote C, Carret JP, Bejui-Hugues J (2007) Unconstrained tripolar implant for primary total hip arthroplasty in patient at risk for dislocation. J Arthroplasty 22(6):849–858CrossRefPubMed Guyen O, Pibarot V, Vaz G, Chevillote C, Carret JP, Bejui-Hugues J (2007) Unconstrained tripolar implant for primary total hip arthroplasty in patient at risk for dislocation. J Arthroplasty 22(6):849–858CrossRefPubMed
11.
go back to reference Huten D (1996) Luxations et subluxations des prothèses totales de hanche. In: Conférences d’enseignement de la SOFCOT. Paris: Expansion scientifique française, 1996. p. 19–46 (Cahiers d’enseignement de la SOFCOT; 55) Huten D (1996) Luxations et subluxations des prothèses totales de hanche. In: Conférences d’enseignement de la SOFCOT. Paris: Expansion scientifique française, 1996. p. 19–46 (Cahiers d’enseignement de la SOFCOT; 55)
12.
go back to reference Keener JD, Callaghan JJ, Goetz DD, Pederson D, Sullivan P, Johnston RC (2003) Long-term function after Charnley total hip arthroplasty. Clin Orthop Relat Res 417:148–156PubMed Keener JD, Callaghan JJ, Goetz DD, Pederson D, Sullivan P, Johnston RC (2003) Long-term function after Charnley total hip arthroplasty. Clin Orthop Relat Res 417:148–156PubMed
13.
go back to reference Khatod M, Barber T, Paxton E, Namba R, Fithian D (2006) An analysis of the risk of hip dislocation with a contemporary total joint registry. Clin Orthop Relat Res 447:19–23CrossRefPubMed Khatod M, Barber T, Paxton E, Namba R, Fithian D (2006) An analysis of the risk of hip dislocation with a contemporary total joint registry. Clin Orthop Relat Res 447:19–23CrossRefPubMed
14.
go back to reference Lautridou C, Lebel B, Burdin G, Vielpeau C (2008) La cupule rétentive, à double mobilité, non scellée de Bousquet dans l’arthroplastie totale de hanche. A propos de 437 hanches. Survie à 16.5 ans de recul moyen. Analyse des échecs. Rev Chir Orthop Reparatrice Appar Mot 94(8):731–739PubMed Lautridou C, Lebel B, Burdin G, Vielpeau C (2008) La cupule rétentive, à double mobilité, non scellée de Bousquet dans l’arthroplastie totale de hanche. A propos de 437 hanches. Survie à 16.5 ans de recul moyen. Analyse des échecs. Rev Chir Orthop Reparatrice Appar Mot 94(8):731–739PubMed
15.
go back to reference Leclercq S, Benoit JY, de Rosa JP, Euvrard P, Leteurtre C, Girardin P (2008) Results of the Evora dual mobility socket: five years follow-up. Rev Chir Orthop Reparatrice Appar Mot 94:37–42PubMed Leclercq S, Benoit JY, de Rosa JP, Euvrard P, Leteurtre C, Girardin P (2008) Results of the Evora dual mobility socket: five years follow-up. Rev Chir Orthop Reparatrice Appar Mot 94:37–42PubMed
16.
go back to reference Lecuire F, Benareau I, Rubini J, Basso M (2004) Luxation intra-prothétique dans la cupule à double mobilité de Bousquet. Rev Chir Orthop Reparatrice Appar Mot 90(3):249–255PubMed Lecuire F, Benareau I, Rubini J, Basso M (2004) Luxation intra-prothétique dans la cupule à double mobilité de Bousquet. Rev Chir Orthop Reparatrice Appar Mot 90(3):249–255PubMed
17.
go back to reference Levy BA, Berry DJ, Pagnano MW (2000) Long-term survivorship of cemented all-polyethylene acetabular components in patients > 75 years of age. J Arthroplasty 15(4):461–467CrossRefPubMed Levy BA, Berry DJ, Pagnano MW (2000) Long-term survivorship of cemented all-polyethylene acetabular components in patients > 75 years of age. J Arthroplasty 15(4):461–467CrossRefPubMed
18.
go back to reference Malchau H, Herberts P, Eisler T, Garellick G, Söderman P (2002) The Swedish Total Hip Replacement Register. J Bone Joint Surg Am 84-A(Suppl 2):2–20. Erratum in: J Bone Joint Surg Am 2004;86(2):363PubMed Malchau H, Herberts P, Eisler T, Garellick G, Söderman P (2002) The Swedish Total Hip Replacement Register. J Bone Joint Surg Am 84-A(Suppl 2):2–20. Erratum in: J Bone Joint Surg Am 2004;86(2):363PubMed
19.
go back to reference Masaoka T, Yamamoto K, Shishido T, Katori Y, Mizoue T, Shirasu H, Nunodaint D (2006) Study of hip joint dislocation after total hip arthroplasty. Int Orthop 30(1):26–30CrossRefPubMed Masaoka T, Yamamoto K, Shishido T, Katori Y, Mizoue T, Shirasu H, Nunodaint D (2006) Study of hip joint dislocation after total hip arthroplasty. Int Orthop 30(1):26–30CrossRefPubMed
20.
go back to reference Nizard R, Ferrari A, Banallec L, Hamadouche M (1998) Méthode d’étude des prothèses totales de hanche chez les patients de moins de 50 ans. Rev Chir Orthop Reparatrice Appar Mot 84:78–80 Nizard R, Ferrari A, Banallec L, Hamadouche M (1998) Méthode d’étude des prothèses totales de hanche chez les patients de moins de 50 ans. Rev Chir Orthop Reparatrice Appar Mot 84:78–80
21.
go back to reference Philippot R, Adam P, Farizon F, Fessy MH, Bousquet G (2006) Survie à dix ans d’une cupule double mobilité non cimentée. Rev Chir Orthop Reparatrice Appar Mot 92(4):326–331PubMed Philippot R, Adam P, Farizon F, Fessy MH, Bousquet G (2006) Survie à dix ans d’une cupule double mobilité non cimentée. Rev Chir Orthop Reparatrice Appar Mot 92(4):326–331PubMed
22.
go back to reference Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F (2009) The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop 33(4):927–932CrossRefPubMed Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F (2009) The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop 33(4):927–932CrossRefPubMed
23.
go back to reference Philippot R, Farizon F, Camilleri JP et al (2008) Survival of dual mobility socket with a mean 17 years follow-up. Rev Chir Orthop Reparatrice Appar Mot 94:43–48PubMed Philippot R, Farizon F, Camilleri JP et al (2008) Survival of dual mobility socket with a mean 17 years follow-up. Rev Chir Orthop Reparatrice Appar Mot 94:43–48PubMed
24.
go back to reference Pineau V, Lebel B, Gouzy S, Dutheil JJ, Vielpeau C (2010) Dual mobility hip arthroplasty wear measurement: experimental accuracy assessment using radiostereometric analysis (RSA). Orthop Traumatol Surg Res 96(6):609–615CrossRef Pineau V, Lebel B, Gouzy S, Dutheil JJ, Vielpeau C (2010) Dual mobility hip arthroplasty wear measurement: experimental accuracy assessment using radiostereometric analysis (RSA). Orthop Traumatol Surg Res 96(6):609–615CrossRef
25.
go back to reference Turner RS (1994) Postoperative total hip prosthetic femoral head dislocations. Incidence, etiologic factors, and management. Clin Orthop Relat Res 301:196–204PubMed Turner RS (1994) Postoperative total hip prosthetic femoral head dislocations. Incidence, etiologic factors, and management. Clin Orthop Relat Res 301:196–204PubMed
26.
go back to reference von Knoch M, Berry DJ, Harmsen WS, Morrey BF (2002) Late dislocation after total hip arthroplasty. J Bone Joint Surg Am 84-A(11):1949–1953 von Knoch M, Berry DJ, Harmsen WS, Morrey BF (2002) Late dislocation after total hip arthroplasty. J Bone Joint Surg Am 84-A(11):1949–1953
27.
go back to reference Woo RY, Morrey BF (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg Am 64(9):1295–1306PubMed Woo RY, Morrey BF (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg Am 64(9):1295–1306PubMed
28.
go back to reference Wroblewski BM (1986) 15-21-year results of the Charnley low-friction arthroplasty. Clin Orthop Relat Res 211:30–35PubMed Wroblewski BM (1986) 15-21-year results of the Charnley low-friction arthroplasty. Clin Orthop Relat Res 211:30–35PubMed
29.
go back to reference Wroblewski BM, Fleming PA, Siney PD (1999) Charnley low-frictional torque arthroplasty of the hip. 20-to-30 year results. J Bone Joint Surg Br 81(3):427–430CrossRefPubMed Wroblewski BM, Fleming PA, Siney PD (1999) Charnley low-frictional torque arthroplasty of the hip. 20-to-30 year results. J Bone Joint Surg Br 81(3):427–430CrossRefPubMed
Metadata
Title
The dual mobility socket concept: experience with 668 cases
Authors
Claude Vielpeau
Benoit Lebel
Ludovic Ardouin
Gilles Burdin
Christine Lautridou
Publication date
01-02-2011
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 2/2011
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-010-1156-8

Other articles of this Issue 2/2011

International Orthopaedics 2/2011 Go to the issue

Acknowledgement to Referees

Acknowledgement to Referees