Skip to main content
Top
Published in: International Orthopaedics 3/2017

01-03-2017 | Orthopaedic Heritage

Once upon a time.... Dual mobility: history

Authors: Daniel Noyer, Jacques Henri Caton

Published in: International Orthopaedics | Issue 3/2017

Login to get access

Abstract

Introduction

Since 1962, the low friction arthroplasty developed by Sir John Charnley has given us very good long terms results at more than 40 years follow up, but dislocation remains a major complication. The dislocation rate is a permanent risk during the life of the patient and the prosthesis, defined by J. Caton and D. Berry in 2004 as a cumulative risk. History and concept development: The concept of dual mobility was thought up by G. Bousquet, A. Rambert and J. Rieu in the 1970s (1974-1979). The first one in 1979 was called NOVAE and combined two articulations: one large and one smaller by a recruitement phenomenon increasing the jumps distance and so decreasing dislocation forces. In 2003, D. Noyer published the first paper about the «third articulation»: a true metal/PE bearing. Since 1996, twenty years after the first patent, many dual mobility cups have been developed with various fixation ways and various designs.

Conclusion

Today with the same principles there are many differences for the «third generation» with excellent results at more than ten years FU with less than 1% to 2% dislocation rate in primary, revision, recurrent THA dislocation and THA after femoral neck fractures.
Literature
1.
go back to reference Huten D (1996) Luxations et subluxations des prothèses totales de hanche. Conférences d’enseignement de la SOFCOT Elsevier, Paris 55: p.19-46. Huten D (1996) Luxations et subluxations des prothèses totales de hanche. Conférences d’enseignement de la SOFCOT Elsevier, Paris 55: p.19-46.
2.
go back to reference Berry DJ, von KM, Schleck CD, Harmsen WS (2004) the cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86-A:9–14CrossRefPubMed Berry DJ, von KM, Schleck CD, Harmsen WS (2004) the cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86-A:9–14CrossRefPubMed
3.
go back to reference Australian Orthopaedic Association National Joint Replacement Registry. (2014) Annual Report.cturner@aoanjrr.org.au Australian Orthopaedic Association National Joint Replacement Registry. (2014) Annual Report.cturner@aoanjrr.org.au
4.
go back to reference AJRR. (2014) Second American Joint Replacement Registry: annual teport on hip and Knee Arthroplasty Data, AAHKS.www.ajrr.net. AJRR. (2014) Second American Joint Replacement Registry: annual teport on hip and Knee Arthroplasty Data, AAHKS.www.​ajrr.​net.
5.
go back to reference Aubriot JH, Lesimple P, Leclercq S (1993) Study of Bousquet’s non-cemented acetabular implant in 100 hybrid total hip prostheses (Charnley type cemented femoral component). Average 5-year follow-up. Acta Orthop Belg 59(1):267–71 Aubriot JH, Lesimple P, Leclercq S (1993) Study of Bousquet’s non-cemented acetabular implant in 100 hybrid total hip prostheses (Charnley type cemented femoral component). Average 5-year follow-up. Acta Orthop Belg 59(1):267–71
6.
go back to reference Bousquet G, Argenson C, Godeneche JL, Cisterne JP, Gazielly DF, Girardin P, Debiesse JL (1986) Recovery after aseptic loosening of cemented total hip arthroplasties with Bousquet’s cementless prosthesis. A propos of 136 cases. Rev Chir Orthop Reparatrice Appar Mot 72(2):70–4PubMed Bousquet G, Argenson C, Godeneche JL, Cisterne JP, Gazielly DF, Girardin P, Debiesse JL (1986) Recovery after aseptic loosening of cemented total hip arthroplasties with Bousquet’s cementless prosthesis. A propos of 136 cases. Rev Chir Orthop Reparatrice Appar Mot 72(2):70–4PubMed
7.
go back to reference Fessy MH, Bejui J, Fisher LP (1993) Bousquet’s threaded stem in first-intention total hip arthroplast. Acta Orthop Belg 59(1):207–11PubMed Fessy MH, Bejui J, Fisher LP (1993) Bousquet’s threaded stem in first-intention total hip arthroplast. Acta Orthop Belg 59(1):207–11PubMed
8.
go back to reference Caton JH, Prudhon JL, Ferreira A, Aslanian T, Verdier R (2014) A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk. Int Orthop 38:1125–29CrossRefPubMedPubMedCentral Caton JH, Prudhon JL, Ferreira A, Aslanian T, Verdier R (2014) A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk. Int Orthop 38:1125–29CrossRefPubMedPubMedCentral
9.
10.
go back to reference Leclercq S, Benoit JY, de Rosa JP, Tallier E, Leteurtre C, Girardin PH (2013) Evora chromium-cobalt dual mobility socket: results at a minimum 10 years’ follow-up. Orthop Traumatol Surg Res 99:758–64 Leclercq S, Benoit JY, de Rosa JP, Tallier E, Leteurtre C, Girardin PH (2013) Evora chromium-cobalt dual mobility socket: results at a minimum 10 years’ follow-up. Orthop Traumatol Surg Res 99:758–64
11.
go back to reference Alacoque M. (1978) L’avenir du cartilage du cotyle face à une prothèse fémorale (Recul maximum de 17 ans). Medical Thesis Université Claude Bernard - Lyon 1, Lyon France. Alacoque M. (1978) L’avenir du cartilage du cotyle face à une prothèse fémorale (Recul maximum de 17 ans). Medical Thesis Université Claude Bernard - Lyon 1, Lyon France.
12.
go back to reference Moore A (1943) Metal hip joint. A case report. J Bone Joint Surg Am 25:688–92 Moore A (1943) Metal hip joint. A case report. J Bone Joint Surg Am 25:688–92
13.
14.
go back to reference Fischer LP, Noyer D, Vial P, Hartmann D, Patricot LM, Laborier JC, Louis D, Ville G, de Mourgues G (1979) Cotyloid cartilage as affected by 3 types of femoral prosthesis. Experimental study. Rev Chir Orthop Reparatrice Appar Mot 65(Suppl 2):47–50PubMed Fischer LP, Noyer D, Vial P, Hartmann D, Patricot LM, Laborier JC, Louis D, Ville G, de Mourgues G (1979) Cotyloid cartilage as affected by 3 types of femoral prosthesis. Experimental study. Rev Chir Orthop Reparatrice Appar Mot 65(Suppl 2):47–50PubMed
15.
go back to reference Fischer LP, Vial P, Noyer D (1979) Le cartilage sain face à une prothèse fémorale chez le lapin. Rev Chir Orthop Reparatrice Appar Mot 65(3):123–163 Fischer LP, Vial P, Noyer D (1979) Le cartilage sain face à une prothèse fémorale chez le lapin. Rev Chir Orthop Reparatrice Appar Mot 65(3):123–163
16.
go back to reference Charnley J (1960) Anchorage of the femoral head prosthesis to the shaft of the femur. J Bone Joint Surg Br 42-B:28–30PubMed Charnley J (1960) Anchorage of the femoral head prosthesis to the shaft of the femur. J Bone Joint Surg Br 42-B:28–30PubMed
18.
go back to reference Charnley J (1970) Total hip replacement by low-friction arthroplasty. Clin Orthop Relat Res 72:7–21PubMed Charnley J (1970) Total hip replacement by low-friction arthroplasty. Clin Orthop Relat Res 72:7–21PubMed
19.
go back to reference Caton J, Aslanian T, Prudhon JL, Ferreira A, Descamps L, Derhi G, Puch J. (2016) La cupule à double mobilité: une nouvelle révolution technique dans la prothèse totale de hanche. Dual mobility cup: a new THA revolution. e-mémoires de l’académie nationale de chirurgie 15:004-10. doi:10.14607/emem.2016.1.004 Caton J, Aslanian T, Prudhon JL, Ferreira A, Descamps L, Derhi G, Puch J. (2016) La cupule à double mobilité: une nouvelle révolution technique dans la prothèse totale de hanche. Dual mobility cup: a new THA revolution. e-mémoires de l’académie nationale de chirurgie 15:004-10. doi:10.​14607/​emem.​2016.​1.​004
20.
go back to reference Bertrand M. (1978) Etude critique d’un système de prothèse cervico-céphalique avec cupule rétentive non scellée dans le traitement des fractures récentes du col du fémur. Medical Thesis, Claude Bernard University - Lyon 1 Lyon France. Bertrand M. (1978) Etude critique d’un système de prothèse cervico-céphalique avec cupule rétentive non scellée dans le traitement des fractures récentes du col du fémur. Medical Thesis, Claude Bernard University - Lyon 1 Lyon France.
21.
go back to reference Rhenter JL. (1977) Proposition d’un nouveau système de prothèse dit intermédiaire à propos de 110 cas. Medical Thesis Claude Bernard University - Lyon 1 Lyon France. Rhenter JL. (1977) Proposition d’un nouveau système de prothèse dit intermédiaire à propos de 110 cas. Medical Thesis Claude Bernard University - Lyon 1 Lyon France.
22.
go back to reference Fischer LP, Olivier H (1979) L’avenir du cotyle face à une prothèse fémorale. Rev Chir Orthop 65:121–63 Fischer LP, Olivier H (1979) L’avenir du cotyle face à une prothèse fémorale. Rev Chir Orthop 65:121–63
23.
go back to reference Fischer LP, Olivier H, Carret JP, Noyer D (1980) Le conflit tête prothétique cotyle. In Hanche opérée, ed. M-Cpdla locomoteur: p. 110-12. Fischer LP, Olivier H, Carret JP, Noyer D (1980) Le conflit tête prothétique cotyle. In Hanche opérée, ed. M-Cpdla locomoteur: p. 110-12.
24.
go back to reference Fischer LP, Olivier H, Gonon GP, Lortat-Jacob A, Carret JP, Béjui J, Noyer D (1980) Les prothèses intermédiaires de la hanche. In Hanche opérée, ed. M-Cpdla locomoteur. Fischer LP, Olivier H, Gonon GP, Lortat-Jacob A, Carret JP, Béjui J, Noyer D (1980) Les prothèses intermédiaires de la hanche. In Hanche opérée, ed. M-Cpdla locomoteur.
25.
go back to reference Noyer D. (1980) Le cartilage articulaire cet inconnu de la chirurgie orthopédique. Medical Thesis Claude Bernard University - Lyon 1 Lyon France. Noyer D. (1980) Le cartilage articulaire cet inconnu de la chirurgie orthopédique. Medical Thesis Claude Bernard University - Lyon 1 Lyon France.
26.
go back to reference Farizon F, de Lavison R, Azoulai JJ, Bousquet G (1998) Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. Int Orthop 22:219–24CrossRefPubMedPubMedCentral Farizon F, de Lavison R, Azoulai JJ, Bousquet G (1998) Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. Int Orthop 22:219–24CrossRefPubMedPubMedCentral
27.
go back to reference Philippot R (2005) Etude de la survie à 10 ans d’un cotyle double mobilité non cimenté. Medical Thesis - Université de Saint-Etienne, France Philippot R (2005) Etude de la survie à 10 ans d’un cotyle double mobilité non cimenté. Medical Thesis - Université de Saint-Etienne, France
28.
go back to reference Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F (2009) The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop 33:927–32CrossRefPubMed Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F (2009) The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop 33:927–32CrossRefPubMed
29.
go back to reference Muller D. (1992) Résultats d’un cotyle blindé strié semi-rétentif à plus de 5 ans. Medical Thesis Claude Bernard University - Lyon 1 France. Muller D. (1992) Résultats d’un cotyle blindé strié semi-rétentif à plus de 5 ans. Medical Thesis Claude Bernard University - Lyon 1 France.
30.
go back to reference Adam P, Farizon F, Fessy M-H (2005) Analyse de surface après explantation de 40 cupules rétentives en polyéthylène à double mobilité. Orthop Traumatol Surg Res 100(1):85–91CrossRef Adam P, Farizon F, Fessy M-H (2005) Analyse de surface après explantation de 40 cupules rétentives en polyéthylène à double mobilité. Orthop Traumatol Surg Res 100(1):85–91CrossRef
31.
go back to reference Lecuire F, Benareau I, Rubini J, Basso M (2004) Intra-prosthetic dislocation of the Bousquet dual mobility socket. Rev Chir Orthop Reparatrice Appar LocoMot 90:249–55CrossRef Lecuire F, Benareau I, Rubini J, Basso M (2004) Intra-prosthetic dislocation of the Bousquet dual mobility socket. Rev Chir Orthop Reparatrice Appar LocoMot 90:249–55CrossRef
32.
go back to reference Noyer D (2003) La troisième articulation des prothèses à double mobilité. Maitrise Orthopédique 121:20–2 Noyer D (2003) La troisième articulation des prothèses à double mobilité. Maitrise Orthopédique 121:20–2
33.
go back to reference Guyen O. (2004) Etude mécanique de la cupule tripolaire à double mobilité dans les arthroplasties totales de hanche. Medical Thesis Claude Bernard University - Lyon 1.Lyon France. Guyen O. (2004) Etude mécanique de la cupule tripolaire à double mobilité dans les arthroplasties totales de hanche. Medical Thesis Claude Bernard University - Lyon 1.Lyon France.
34.
go back to reference Christiansen T (1969) A new hip prosthesis with trunnion-bearing. Acta Chir Scand 135:43–6PubMed Christiansen T (1969) A new hip prosthesis with trunnion-bearing. Acta Chir Scand 135:43–6PubMed
Metadata
Title
Once upon a time.... Dual mobility: history
Authors
Daniel Noyer
Jacques Henri Caton
Publication date
01-03-2017
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 3/2017
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3361-6

Other articles of this Issue 3/2017

International Orthopaedics 3/2017 Go to the issue