Skip to main content
Top
Published in: Abdominal Radiology 6/2021

01-06-2021 | Computed Tomography | Pancreas

Simulated twin-phase pancreatic CT generated using single portal venous phase dual-energy CT acquisition in pancreatic ductal adenocarcinoma

Authors: Yoshifumi Noda, Toru Tochigi, Anushri Parakh, Avinash Kambadakone

Published in: Abdominal Radiology | Issue 6/2021

Login to get access

Abstract

Purpose

To evaluate the diagnostic performance of a simulated twin-phase pancreatic protocol CT generated from a single portal venous phase (PVP) dual-energy CT (DECT) acquisition in patients with pancreatic ductal adenocarcinoma (PDAC).

Methods

In this retrospective study, we included 63 patients with PDAC who underwent pancreatic protocol (pancreatic phase [PP] and PVP) DECT. Two data sets were created from this original acquisition—(1) Standard protocol (50 keV PP/65 keV PVP) and (2) Simulated protocol (40 keV/65 keV PVP). Using a 5-point scale, three readers scored image quality, tumor conspicuity, and arterial involvement by the PDAC. Signal-to-noise ratio (SNR) of the pancreas and tumor-to-pancreas contrast-to-noise ratio (CNR) were calculated. Qualitative scores, quantitative parameters, and radiation dose were compared between standard and simulated protocols.

Results

No significant difference in detection rate of PDAC was seen between the standard (58/63, 92.1%) and simulated protocols (56/63, 88.9%) (P = 0.76). Subjective scoring for arterial involvement for celiac (P = 0.86), superior mesenteric (P = 0.88), splenic (P = 0.86), common hepatic (P = 0.52), gastroduodenal (P = 0.95), first jejunal (P = 0.48) arteries, and aorta (P = 1.00) were comparable between two protocols. The image quality (P = 0.14), the SNR of the pancreas (P = 0.15), and CNR (P = 0.54) were comparable between two protocols. The projected mean dose-length product (DLP) (629.6 ± 148.3 mGy cm) in the simulated protocol showed a 44% reduction in radiation dose compared to the standard protocol (mean DLP, 1123.3 ± 268.9 mGy cm) (P < 0.0001).

Conclusions

Low keV images generated from a PVP DECT acquisition allows creation of a twin-phase pancreatic protocol CT with comparable diagnostic accuracy for detecting PDAC with significant reduction in radiation dose. Reduced radiation dose is desirable in surveillance and screening for pancreatic diseases.
Literature
1.
go back to reference Rahib L, Smith BD, Aizenberg R, Rosenzweig AB, Fleshman JM, Matrisian LM. Projecting cancer incidence and deaths to 2030: the unexpected burden of thyroid, liver, and pancreas cancers in the United States. Cancer Res 2014; 74:2913-2921CrossRef Rahib L, Smith BD, Aizenberg R, Rosenzweig AB, Fleshman JM, Matrisian LM. Projecting cancer incidence and deaths to 2030: the unexpected burden of thyroid, liver, and pancreas cancers in the United States. Cancer Res 2014; 74:2913-2921CrossRef
2.
go back to reference Klauss M, Schobinger M, Wolf I, et al. Value of three-dimensional reconstructions in pancreatic carcinoma using multidetector CT: initial results. World J Gastroenterol 2009; 15:5827-5832CrossRef Klauss M, Schobinger M, Wolf I, et al. Value of three-dimensional reconstructions in pancreatic carcinoma using multidetector CT: initial results. World J Gastroenterol 2009; 15:5827-5832CrossRef
4.
go back to reference Kulkarni NM, Soloff EV, Tolat PP, et al. White paper on pancreatic ductal adenocarcinoma from society of abdominal radiology's disease-focused panel for pancreatic ductal adenocarcinoma: Part I, AJCC staging system, NCCN guidelines, and borderline resectable disease. Abdom Radiol (NY) 2020; 45:716-728CrossRef Kulkarni NM, Soloff EV, Tolat PP, et al. White paper on pancreatic ductal adenocarcinoma from society of abdominal radiology's disease-focused panel for pancreatic ductal adenocarcinoma: Part I, AJCC staging system, NCCN guidelines, and borderline resectable disease. Abdom Radiol (NY) 2020; 45:716-728CrossRef
5.
go back to reference Kulkarni NM, Hough DM, Tolat PP, Soloff EV, Kambadakone AR. Pancreatic adenocarcinoma: cross-sectional imaging techniques. Abdom Radiol (NY) 2018; 43:253-263CrossRef Kulkarni NM, Hough DM, Tolat PP, Soloff EV, Kambadakone AR. Pancreatic adenocarcinoma: cross-sectional imaging techniques. Abdom Radiol (NY) 2018; 43:253-263CrossRef
6.
go back to reference Singhi AD, Koay EJ, Chari ST, Maitra A. Early Detection of Pancreatic Cancer: Opportunities and Challenges. Gastroenterology 2019; 156:2024-2040CrossRef Singhi AD, Koay EJ, Chari ST, Maitra A. Early Detection of Pancreatic Cancer: Opportunities and Challenges. Gastroenterology 2019; 156:2024-2040CrossRef
7.
go back to reference Noda Y, Goshima S, Kaga T, et al. Virtual monochromatic image at lower energy level for assessing pancreatic ductal adenocarcinoma in fast kV-switching dual-energy CT. Clin Radiol 2019; Noda Y, Goshima S, Kaga T, et al. Virtual monochromatic image at lower energy level for assessing pancreatic ductal adenocarcinoma in fast kV-switching dual-energy CT. Clin Radiol 2019;
8.
go back to reference Ohira S, Kanayama N, Wada K, et al. A Third-Generation Adaptive Statistical Iterative Reconstruction for Contrast-Enhanced 4-Dimensional Dual-Energy Computed Tomography for Pancreatic Cancer. J Comput Assist Tomogr 2019; Ohira S, Kanayama N, Wada K, et al. A Third-Generation Adaptive Statistical Iterative Reconstruction for Contrast-Enhanced 4-Dimensional Dual-Energy Computed Tomography for Pancreatic Cancer. J Comput Assist Tomogr 2019;
9.
go back to reference Aslan S, Camlidag I, Nural MS. Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT. Abdom Radiol (NY) 2019; 44:568-575CrossRef Aslan S, Camlidag I, Nural MS. Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT. Abdom Radiol (NY) 2019; 44:568-575CrossRef
10.
go back to reference Apfaltrer P, Sudarski S, Schneider D, et al. Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography. Eur J Radiol 2014; 83:322-328CrossRef Apfaltrer P, Sudarski S, Schneider D, et al. Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography. Eur J Radiol 2014; 83:322-328CrossRef
11.
go back to reference Brook OR, Gourtsoyianni S, Brook A, Siewert B, Kent T, Raptopoulos V. Split-bolus spectral multidetector CT of the pancreas: assessment of radiation dose and tumor conspicuity. Radiology 2013; 269:139-148CrossRef Brook OR, Gourtsoyianni S, Brook A, Siewert B, Kent T, Raptopoulos V. Split-bolus spectral multidetector CT of the pancreas: assessment of radiation dose and tumor conspicuity. Radiology 2013; 269:139-148CrossRef
12.
go back to reference Camacho A, Fang J, Cohen MP, Raptopoulos V, Brook OR. Split-bolus pancreas CTA protocol for local staging of pancreatic cancer and detection and characterization of liver lesions. Abdom Radiol (NY) 2018; 43:340-350CrossRef Camacho A, Fang J, Cohen MP, Raptopoulos V, Brook OR. Split-bolus pancreas CTA protocol for local staging of pancreatic cancer and detection and characterization of liver lesions. Abdom Radiol (NY) 2018; 43:340-350CrossRef
13.
go back to reference Noda Y, Goshima S, Kozaka K, et al. Optimal window settings in single-source dual-energy computed tomography of the abdomen. Eur J Radiol 2018; 109:204-209CrossRef Noda Y, Goshima S, Kozaka K, et al. Optimal window settings in single-source dual-energy computed tomography of the abdomen. Eur J Radiol 2018; 109:204-209CrossRef
14.
go back to reference Noda Y, Goshima S, Takai Y, et al. Detection of pancreatic ductal adenocarcinoma and liver metastases: comparison of Gd-EOB-DTPA-enhanced MR imaging vs. extracellular contrast materials. Abdom Radiol (NY) 2020; 45:2459–2468 Noda Y, Goshima S, Takai Y, et al. Detection of pancreatic ductal adenocarcinoma and liver metastases: comparison of Gd-EOB-DTPA-enhanced MR imaging vs. extracellular contrast materials. Abdom Radiol (NY) 2020; 45:2459–2468
15.
go back to reference Noda Y, Goshima S, Koyasu H, et al. Renovascular CT: comparison between adaptive statistical iterative reconstruction and model-based iterative reconstruction. Clin Radiol 2017; 72:901 e913–901 e919 Noda Y, Goshima S, Koyasu H, et al. Renovascular CT: comparison between adaptive statistical iterative reconstruction and model-based iterative reconstruction. Clin Radiol 2017; 72:901 e913–901 e919
16.
go back to reference Hong SB, Lee SS, Kim JH, et al. Pancreatic Cancer CT: Prediction of Resectability according to NCCN Criteria. Radiology 2018; 289:710-718CrossRef Hong SB, Lee SS, Kim JH, et al. Pancreatic Cancer CT: Prediction of Resectability according to NCCN Criteria. Radiology 2018; 289:710-718CrossRef
17.
go back to reference Al-Hawary MM, Francis IR, Chari ST, et al. Pancreatic ductal adenocarcinoma radiology reporting template: consensus statement of the Society of Abdominal Radiology and the American Pancreatic Association. Radiology 2014; 270:248-260CrossRef Al-Hawary MM, Francis IR, Chari ST, et al. Pancreatic ductal adenocarcinoma radiology reporting template: consensus statement of the Society of Abdominal Radiology and the American Pancreatic Association. Radiology 2014; 270:248-260CrossRef
18.
go back to reference Uhrig M, Simons D, Kachelriess M, Pisana F, Kuchenbecker S, Schlemmer HP. Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose. Cancer Imaging 2016; 16:15CrossRef Uhrig M, Simons D, Kachelriess M, Pisana F, Kuchenbecker S, Schlemmer HP. Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose. Cancer Imaging 2016; 16:15CrossRef
19.
go back to reference Noda Y, Goshima S, Miyoshi T, et al. Determination of the least amount of iodine load required for the detection of pancreatic adenocarcinoma at 80-kVp CT. Eur J Radiol 2016; 85:901-905CrossRef Noda Y, Goshima S, Miyoshi T, et al. Determination of the least amount of iodine load required for the detection of pancreatic adenocarcinoma at 80-kVp CT. Eur J Radiol 2016; 85:901-905CrossRef
20.
go back to reference Christner JA, Kofler JM, McCollough CH. Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol 2010; 194:881-889CrossRef Christner JA, Kofler JM, McCollough CH. Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol 2010; 194:881-889CrossRef
21.
go back to reference Noda Y, Goshima S, Kaga T, et al. Virtual monochromatic image at lower energy level for assessing pancreatic ductal adenocarcinoma in fast kV-switching dual-energy CT. Clin Radiol 2020; 75:320 e317–320 e323 Noda Y, Goshima S, Kaga T, et al. Virtual monochromatic image at lower energy level for assessing pancreatic ductal adenocarcinoma in fast kV-switching dual-energy CT. Clin Radiol 2020; 75:320 e317–320 e323
22.
go back to reference Yin Q, Zou X, Zai X, et al. Pancreatic ductal adenocarcinoma and chronic mass-forming pancreatitis: Differentiation with dual-energy MDCT in spectral imaging mode. Eur J Radiol 2015; 84:2470-2476CrossRef Yin Q, Zou X, Zai X, et al. Pancreatic ductal adenocarcinoma and chronic mass-forming pancreatitis: Differentiation with dual-energy MDCT in spectral imaging mode. Eur J Radiol 2015; 84:2470-2476CrossRef
23.
go back to reference Gupta S, Wagner-Bartak N, Jensen CT, et al. Dual-energy CT of pancreatic adenocarcinoma: reproducibility of primary tumor measurements and assessment of tumor conspicuity and margin sharpness. Abdom Radiol (NY) 2016; 41:1317-1324CrossRef Gupta S, Wagner-Bartak N, Jensen CT, et al. Dual-energy CT of pancreatic adenocarcinoma: reproducibility of primary tumor measurements and assessment of tumor conspicuity and margin sharpness. Abdom Radiol (NY) 2016; 41:1317-1324CrossRef
24.
go back to reference Wu R, Watanabe Y, Satoh K, et al. Quantitative Comparison of Virtual Monochromatic Images of Dual Energy Computed Tomography Systems: Beam Hardening Artifact Correction and Variance in Computed Tomography Numbers: A Phantom Study. J Comput Assist Tomogr 2018; 42:648-654CrossRef Wu R, Watanabe Y, Satoh K, et al. Quantitative Comparison of Virtual Monochromatic Images of Dual Energy Computed Tomography Systems: Beam Hardening Artifact Correction and Variance in Computed Tomography Numbers: A Phantom Study. J Comput Assist Tomogr 2018; 42:648-654CrossRef
25.
go back to reference Sugawara H, Suzuki S, Katada Y, et al. Comparison of full-iodine conventional CT and half-iodine virtual monochromatic imaging: advantages and disadvantages. Eur Radiol 2019; 29:1400-1407CrossRef Sugawara H, Suzuki S, Katada Y, et al. Comparison of full-iodine conventional CT and half-iodine virtual monochromatic imaging: advantages and disadvantages. Eur Radiol 2019; 29:1400-1407CrossRef
26.
go back to reference Sugawara H, Takayanagi T, Ishikawa T, et al. New Fast kVp Switching Dual-Energy CT: Reduced Severity of Beam Hardening Artifacts and Improved Image Quality in Reduced-Iodine Virtual Monochromatic Imaging. Acad Radiol 2019; Sugawara H, Takayanagi T, Ishikawa T, et al. New Fast kVp Switching Dual-Energy CT: Reduced Severity of Beam Hardening Artifacts and Improved Image Quality in Reduced-Iodine Virtual Monochromatic Imaging. Acad Radiol 2019;
27.
go back to reference Han WK, Na JC, Park SY. Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy. Eur Radiol 2020; 30:798-805CrossRef Han WK, Na JC, Park SY. Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy. Eur Radiol 2020; 30:798-805CrossRef
28.
go back to reference Tang H, Liu Z, Hu Z, et al. Clinical value of a new generation adaptive statistical iterative reconstruction (ASIR-V) in the diagnosis of pulmonary nodule in low-dose chest CT. Br J Radiol 2019; 92:20180909CrossRef Tang H, Liu Z, Hu Z, et al. Clinical value of a new generation adaptive statistical iterative reconstruction (ASIR-V) in the diagnosis of pulmonary nodule in low-dose chest CT. Br J Radiol 2019; 92:20180909CrossRef
29.
go back to reference Chen Y, Liu Z, Li M, et al. Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol. Eur Radiol 2019; 29:3036-3043CrossRef Chen Y, Liu Z, Li M, et al. Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol. Eur Radiol 2019; 29:3036-3043CrossRef
30.
go back to reference Chen LH, Jin C, Li JY, et al. Image quality comparison of two adaptive statistical iterative reconstruction (ASiR, ASiR-V) algorithms and filtered back projection in routine liver CT. Br J Radiol 2018; 91:20170655CrossRef Chen LH, Jin C, Li JY, et al. Image quality comparison of two adaptive statistical iterative reconstruction (ASiR, ASiR-V) algorithms and filtered back projection in routine liver CT. Br J Radiol 2018; 91:20170655CrossRef
31.
go back to reference Tamm EP, Loyer EM, Faria SC, Evans DB, Wolff RA, Charnsangavej C. Retrospective analysis of dual-phase MDCT and follow-up EUS/EUS-FNA in the diagnosis of pancreatic cancer. Abdom Imaging 2007; 32:660-667CrossRef Tamm EP, Loyer EM, Faria SC, Evans DB, Wolff RA, Charnsangavej C. Retrospective analysis of dual-phase MDCT and follow-up EUS/EUS-FNA in the diagnosis of pancreatic cancer. Abdom Imaging 2007; 32:660-667CrossRef
32.
go back to reference DeWitt J, Devereaux B, Chriswell M, et al. Comparison of endoscopic ultrasonography and multidetector computed tomography for detecting and staging pancreatic cancer. Ann Intern Med 2004; 141:753-763CrossRef DeWitt J, Devereaux B, Chriswell M, et al. Comparison of endoscopic ultrasonography and multidetector computed tomography for detecting and staging pancreatic cancer. Ann Intern Med 2004; 141:753-763CrossRef
33.
go back to reference 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP 1991; 21:1-201CrossRef 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP 1991; 21:1-201CrossRef
34.
go back to reference Kanal KM, Butler PF, Sengupta D, Bhargavan-Chatfield M, Coombs LP, Morin RL. U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations. Radiology 2017; 284:120-133CrossRef Kanal KM, Butler PF, Sengupta D, Bhargavan-Chatfield M, Coombs LP, Morin RL. U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations. Radiology 2017; 284:120-133CrossRef
Metadata
Title
Simulated twin-phase pancreatic CT generated using single portal venous phase dual-energy CT acquisition in pancreatic ductal adenocarcinoma
Authors
Yoshifumi Noda
Toru Tochigi
Anushri Parakh
Avinash Kambadakone
Publication date
01-06-2021
Publisher
Springer US
Published in
Abdominal Radiology / Issue 6/2021
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-020-02921-9

Other articles of this Issue 6/2021

Abdominal Radiology 6/2021 Go to the issue

Classics in Abdominal Radiology

The “star sign” in Crohn’s disease