Skip to main content
Top
Published in: Abdominal Radiology 10/2020

01-10-2020 | Computed Tomography | Technical

The omental free flap and flow-through flap: pre-operative evaluation of right gastro-omental artery on multidetector computed tomography

Authors: Nicla Settembre, Zakariyae Bouziane, Damien Mandry, Marc Braun, Sergueï Malikov

Published in: Abdominal Radiology | Issue 10/2020

Login to get access

Abstract

Background

The gastro-omental artery (GOA) and the greater omentum are nowadays commonly used in many reconstructive surgeries, including cardiac, vascular, and plastic surgery. There are cases in which the GOA is found to be unsuitable only after partial harvesting following an upper laparotomy, and an improved method of pre-operative evaluation is required to eliminate the need for intraoperative small laparotomy.

Methods

Multidetector computed tomography was performed for 30 consecutive patients admitted for lower limb ischemia in a routine pre-operative evaluation of lower limb peripheral arterial disease (PAD). The origin of the GOA was checked on coronal and sagittal slices, its pathway was identified on the three-dimensional rendering. We assessed length and mean diameter of the distal and proximal right GOA, and the mean distances between the origins of GOA and the omental branches. Finally, we report one case of omental flow-through flap.

Results

30 patients were included in our study. Routine pre-operative MDCT during lower limb PAD workup enabled identification of GOA in all cases. The mean internal diameter of the GOA at its origin was 3.3 mm (± 3.3). The mean internal diameter of the distal GOA was 1.26 mm (± 0.3). At least one omental descending branch was detected in every case and in 63% (19 patients) at least two branches were visualized.

Conclusion

Routine pre-operative angio-MDCT imaging is an effective tool to assess precisely the different anatomical properties of the GOA. This exam could be useful for both diagnosis of lower limb PAD and evaluation of the GOA suitability for flow-through flap lower limb revascularisation.
Literature
1.
go back to reference McLean DH, Buncke HJ Jr. Autotransplant of omentum to a large scalp defect, with microsurgical revascularization. Plast Reconstr Surg. 1972 Mar;49(3):268-74.CrossRef McLean DH, Buncke HJ Jr. Autotransplant of omentum to a large scalp defect, with microsurgical revascularization. Plast Reconstr Surg. 1972 Mar;49(3):268-74.CrossRef
3.
go back to reference Settembre N, Labrousse M, Magnan PE, Branchereau A, Champsaur P, Bussani R, Braun M, Malikov S. Surgical anatomy of the right gastro-omental artery: a study on 100 cadaver dissections. Surg Radiol Anat. 2018 Apr. 40 (4), 415-422.CrossRef Settembre N, Labrousse M, Magnan PE, Branchereau A, Champsaur P, Bussani R, Braun M, Malikov S. Surgical anatomy of the right gastro-omental artery: a study on 100 cadaver dissections. Surg Radiol Anat. 2018 Apr. 40 (4), 415-422.CrossRef
4.
go back to reference Settembre N, Malikov S, Branchereau A, Champsaur P, Bussani R, Magnan PE. Epiploic Bypass Flap: A New Method of Limb Salvage. Anatomic Basis and Clinical Application. Ann Vasc Surg. 2013 Dec 4. Settembre N, Malikov S, Branchereau A, Champsaur P, Bussani R, Magnan PE. Epiploic Bypass Flap: A New Method of Limb Salvage. Anatomic Basis and Clinical Application. Ann Vasc Surg. 2013 Dec 4.
6.
go back to reference Alday ES, Goldsmith HS. Surgical technique for omental lengthening based on arterial anatomy. Surg Gynecol Obstet. 1972 Jul;135(1):103-7.PubMed Alday ES, Goldsmith HS. Surgical technique for omental lengthening based on arterial anatomy. Surg Gynecol Obstet. 1972 Jul;135(1):103-7.PubMed
7.
go back to reference Bourgeon A., Tran D.K., Abbes M., Clermont C., Lebreton E., Richelme H. Etude de la vascularisation du grand épiploon. Applications chirurgicales. Bull. Ass. Anat., 1973,57:829-838. Bourgeon A., Tran D.K., Abbes M., Clermont C., Lebreton E., Richelme H. Etude de la vascularisation du grand épiploon. Applications chirurgicales. Bull. Ass. Anat., 1973,57:829-838.
8.
go back to reference Cathala B. Etude radio-anatomique de la vascularisation du grand épiploon. Thèse Toulouse 1975 n 263. Cathala B. Etude radio-anatomique de la vascularisation du grand épiploon. Thèse Toulouse 1975 n 263.
9.
go back to reference van Son JA, Smedts FM, Yang CQ, Mravunac M, Falk V, Mohr FW, He GW. Morphometric study of the right gastroepiploic and inferior epigastric arteries. Ann Thorac Surg. 1997 Mar;63(3):709-15.CrossRef van Son JA, Smedts FM, Yang CQ, Mravunac M, Falk V, Mohr FW, He GW. Morphometric study of the right gastroepiploic and inferior epigastric arteries. Ann Thorac Surg. 1997 Mar;63(3):709-15.CrossRef
10.
go back to reference Lestrade M, Joffre P, Putois M. Artères épiploïques. Aspects radiologiques normaux et pathologiques. J Radiol Electrol Med Nucl. 1975, Jan; 56 (1): 35-43. Lestrade M, Joffre P, Putois M. Artères épiploïques. Aspects radiologiques normaux et pathologiques. J Radiol Electrol Med Nucl. 1975, Jan; 56 (1): 35-43.
11.
go back to reference Micheau PH, Castagliola M, Joffre F, Lestrade M, Cathala B, Chavoin JP, Clouet M, Lagleize J. Utilisation du grand épiploon, bases anathomiques et radiologiques. Ann Chir Plast. 1975; 20 (3-4): 311-8.PubMed Micheau PH, Castagliola M, Joffre F, Lestrade M, Cathala B, Chavoin JP, Clouet M, Lagleize J. Utilisation du grand épiploon, bases anathomiques et radiologiques. Ann Chir Plast. 1975; 20 (3-4): 311-8.PubMed
12.
go back to reference Jin H, Min PQ, Yang ZG, Song B, Wu B. A study of multi-detector row CT scan on greater omentum in 50 individuals: correlating with anatomical basis and clinical application. Surg Radiol Anat. 2008 Feb;30(1):69-75.CrossRef Jin H, Min PQ, Yang ZG, Song B, Wu B. A study of multi-detector row CT scan on greater omentum in 50 individuals: correlating with anatomical basis and clinical application. Surg Radiol Anat. 2008 Feb;30(1):69-75.CrossRef
13.
go back to reference Kamohara K1, Minato N, Minematsu N, Yunoki J, Hakuba T, Satoh H, Morokuma H, Takao Y. Preoperative evaluation of the right gastroepiploic artery on multidetector computed tomography in coronary artery bypass graft surgery. Ann Thorac Surg.2008 Nov;86(5):1444-9. Kamohara K1, Minato N, Minematsu N, Yunoki J, Hakuba T, Satoh H, Morokuma H, Takao Y. Preoperative evaluation of the right gastroepiploic artery on multidetector computed tomography in coronary artery bypass graft surgery. Ann Thorac Surg.2008 Nov;86(5):1444-9.
14.
go back to reference Kuettner A1, Beck T, Drosch T, Kettering K, Heuschmid M, Burgstahler C, Claussen CD, Kopp AF, Schroeder S. Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution. J Am Coll Cardiol. 2005 Jan 4;45(1):123-7. Kuettner A1, Beck T, Drosch T, Kettering K, Heuschmid M, Burgstahler C, Claussen CD, Kopp AF, Schroeder S. Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution. J Am Coll Cardiol. 2005 Jan 4;45(1):123-7.
Metadata
Title
The omental free flap and flow-through flap: pre-operative evaluation of right gastro-omental artery on multidetector computed tomography
Authors
Nicla Settembre
Zakariyae Bouziane
Damien Mandry
Marc Braun
Sergueï Malikov
Publication date
01-10-2020
Publisher
Springer US
Published in
Abdominal Radiology / Issue 10/2020
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-020-02493-8

Other articles of this Issue 10/2020

Abdominal Radiology 10/2020 Go to the issue