Abstract

We aim to assess the safety, feasibility and efficacy of the new Nit-Occlud ASD-R (NOASD-R) device. From 2014 to 2015, transcatheter closure of atrial septal defect (ASD) using the NOASD-R was performed in 30 consecutive patients. The standard deployment technique as the left upper pulmonary vein approach was used in 25 patients. Right upper pulmonary vein approach was required in five. The median age was 6 years (range 3.5–60 years), and median weight was 21.5 kg (14–79 kg). Implantation was successful in all patients. The median size of devices was 16 mm (12.0–26.0 mm). The mean device size/2D defect diameter ratio was 1.26 ± 0.09 (1.12–1.40). The mean device size/color flow diameter ratio was 1.07 ± 0.06 (range 1.0–1.22). Releasing problem was encountered in three patients. A device-related erosion on the day after the closure was observed in one patient. No further device-related complication (erosion, embolization or dislodgement of the device) was encountered in a median follow-up period of 10 months (range 2–14 months). Complete occlusion has occurred in all at follow-up. NOASD-R is a feasible and effective device for use in the transcatheter occlusion of moderate to large secundum ASDs in selected patients. The occurrence of the erosion on the right atrial roof may be due to the high localization of the device and the larger size of the right disk.
Literature
1.
go back to reference Fischer G, Stieh J, Uebing A, Hoffmann U, Morf G, Kramer HH (2006) Experience with transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: a single centre study in 236 consecutive patients. Heart 89:199–204CrossRef Fischer G, Stieh J, Uebing A, Hoffmann U, Morf G, Kramer HH (2006) Experience with transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: a single centre study in 236 consecutive patients. Heart 89:199–204CrossRef
2.
go back to reference Pedra CA, Pedra SF, Esteves CA et al (2003) Initial experience in Brazil with the Helex septal occluder for percutaneous occlusion of atrial septal defects. Arq Bras Cardiol 81:435–452PubMed Pedra CA, Pedra SF, Esteves CA et al (2003) Initial experience in Brazil with the Helex septal occluder for percutaneous occlusion of atrial septal defects. Arq Bras Cardiol 81:435–452PubMed
3.
go back to reference Hsieh KS, Lee CL, Lin CC, Huang TC (2003) Transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: initial experience in Taiwan. Int J Angiol 12:122–124CrossRef Hsieh KS, Lee CL, Lin CC, Huang TC (2003) Transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: initial experience in Taiwan. Int J Angiol 12:122–124CrossRef
4.
go back to reference Lairakdomrong K, Srimahachota S, Lertsapcharoen P, Chaipromprasit J, Boonyaratavej S, Kaewsukkho P (2006) Clinical results of large secundum atrial septal defect closure in adult using percutaneous transcatheter Cocoon atrial septal occluder. J Med Assoc Thai 96:1127–1134 Lairakdomrong K, Srimahachota S, Lertsapcharoen P, Chaipromprasit J, Boonyaratavej S, Kaewsukkho P (2006) Clinical results of large secundum atrial septal defect closure in adult using percutaneous transcatheter Cocoon atrial septal occluder. J Med Assoc Thai 96:1127–1134
5.
go back to reference Thanopoulos BD, Biasco L, Dardas P et al (2014) Catheter closure of atrial septal defects using the Cocoon septal occluder: preliminary results of a European multicenter study. Int J Cardiol 177:418–422CrossRefPubMed Thanopoulos BD, Biasco L, Dardas P et al (2014) Catheter closure of atrial septal defects using the Cocoon septal occluder: preliminary results of a European multicenter study. Int J Cardiol 177:418–422CrossRefPubMed
6.
go back to reference Amin Z, Hijazi ZM, Bass JL, Cheatham JP, Hellenbrand WE, Kleinman CS (2004) Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv 63:496–502CrossRefPubMed Amin Z, Hijazi ZM, Bass JL, Cheatham JP, Hellenbrand WE, Kleinman CS (2004) Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv 63:496–502CrossRefPubMed
7.
go back to reference Crawford GB, Brindis RG, Krucoff MW, Mansalis BP, Carroll JD (2012) Percutaneous atrial septal occluder devices and cardiac erosion: a review of the literature. Catheter Cardiovasc Interv 80:157–167CrossRefPubMed Crawford GB, Brindis RG, Krucoff MW, Mansalis BP, Carroll JD (2012) Percutaneous atrial septal occluder devices and cardiac erosion: a review of the literature. Catheter Cardiovasc Interv 80:157–167CrossRefPubMed
8.
go back to reference Diab K, Kenny D, Hijazi ZM (2012) Erosions, erosions, and erosions! Device closure of atrial septal defects: how safe is safe? Catheter Cardiovasc Interv 80:168–174CrossRefPubMed Diab K, Kenny D, Hijazi ZM (2012) Erosions, erosions, and erosions! Device closure of atrial septal defects: how safe is safe? Catheter Cardiovasc Interv 80:168–174CrossRefPubMed
9.
go back to reference Peirone A, Contreras A, Ferrero A, da Costa RN, Pedra SF, Pedra CA (2014) Immediate and short-term outcomes after percutaneous atrial septal defect closure using the new nit-occlud ASD-R device. Catheter Cardiovasc Interv 84:464–470CrossRefPubMed Peirone A, Contreras A, Ferrero A, da Costa RN, Pedra SF, Pedra CA (2014) Immediate and short-term outcomes after percutaneous atrial septal defect closure using the new nit-occlud ASD-R device. Catheter Cardiovasc Interv 84:464–470CrossRefPubMed
10.
go back to reference Mortezaeian H, Sayadpour Zanjani K, Malakan Rad E (2013) Transcatheter atrial septal defect closure using occlutech figulla device: a two-center experience. J Tehran Heart Cent 8:197–201PubMedPubMedCentral Mortezaeian H, Sayadpour Zanjani K, Malakan Rad E (2013) Transcatheter atrial septal defect closure using occlutech figulla device: a two-center experience. J Tehran Heart Cent 8:197–201PubMedPubMedCentral
11.
go back to reference Haas NA, Happel CM, Soetemann DB et al (2014) Optimal septum alignment of the Figulla Flex Occluder to the atrial septum in patients with secundum atrial septal defects. Eurointervention. doi:10.4244/EIJY14M12_09 Haas NA, Happel CM, Soetemann DB et al (2014) Optimal septum alignment of the Figulla Flex Occluder to the atrial septum in patients with secundum atrial septal defects. Eurointervention. doi:10.​4244/​EIJY14M12_​09
13.
go back to reference Erdem A, Sarıtas T, Zeybek C et al (2013) Transthoracic echocardiographic guidance during transcatheter closure of atrial septal defects in children and adults. Int J Cardiovasc Imaging 29:53–61CrossRefPubMed Erdem A, Sarıtas T, Zeybek C et al (2013) Transthoracic echocardiographic guidance during transcatheter closure of atrial septal defects in children and adults. Int J Cardiovasc Imaging 29:53–61CrossRefPubMed
14.
go back to reference Sadiq N, Ullah M, Sultan M, Akhtar K (2014) Transthoracic echocardiography as a measuring and guiding tool for transcatheter device closure of secundum atrial septal defect in young children. J Invasive Cardiol 26:245–248PubMed Sadiq N, Ullah M, Sultan M, Akhtar K (2014) Transthoracic echocardiography as a measuring and guiding tool for transcatheter device closure of secundum atrial septal defect in young children. J Invasive Cardiol 26:245–248PubMed
15.
go back to reference Lange RA (2012) Confidence in ASD occluder devices is eroding. Catheter Cardiovasc Interv 80:175–176CrossRefPubMed Lange RA (2012) Confidence in ASD occluder devices is eroding. Catheter Cardiovasc Interv 80:175–176CrossRefPubMed
16.
go back to reference Amin Z (2014) Echocardiographic predictors of cardiac erosion after Amplatzer septal occluder placement. Catheter Cardiovasc Interv 83:84–92CrossRefPubMed Amin Z (2014) Echocardiographic predictors of cardiac erosion after Amplatzer septal occluder placement. Catheter Cardiovasc Interv 83:84–92CrossRefPubMed
17.
go back to reference Tchantchaleishvili V, Melvin AL, Ling FS, Knight PA (2014) Late erosion of Amplatzer septal occluder device resulting in cardiac tamponade. Interact CardioVasc Thorac Surg 19:1074–1076CrossRefPubMed Tchantchaleishvili V, Melvin AL, Ling FS, Knight PA (2014) Late erosion of Amplatzer septal occluder device resulting in cardiac tamponade. Interact CardioVasc Thorac Surg 19:1074–1076CrossRefPubMed
18.
go back to reference Aggoun Y, Gallet B, Acar P et al (2002) Perforation of the aorta after percutaneous closure of an atrial septal defect with an Amplatz prosthesis, presenting with acute severe hemolysis. Arch Mal Coeur Vaiss 95:479–482PubMed Aggoun Y, Gallet B, Acar P et al (2002) Perforation of the aorta after percutaneous closure of an atrial septal defect with an Amplatz prosthesis, presenting with acute severe hemolysis. Arch Mal Coeur Vaiss 95:479–482PubMed
19.
go back to reference Wang JK, Tsai SK, Lin SM, Chiu SN, Lin MT, Wu MH (2008) Transcatheter closure of atrial septal defect without balloon sizing. Catheter Cardiovasc Interv 71:214–221CrossRefPubMed Wang JK, Tsai SK, Lin SM, Chiu SN, Lin MT, Wu MH (2008) Transcatheter closure of atrial septal defect without balloon sizing. Catheter Cardiovasc Interv 71:214–221CrossRefPubMed
Metadata
Title
Initial Experience with the Nit-Occlud ASD-R: Short-Term Results
Authors
Mustafa Orhan Bulut
Ilker Kemal Yucel
Mehmet Kucuk
Sevket Balli
Evic Zeynep Basar
Ahmet Celebi
Publication date
01-10-2016
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 7/2016
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-016-1426-3

Other articles of this Issue 7/2016

Pediatric Cardiology 7/2016 Go to the issue