Skip to main content
Top
Published in: Pediatric Cardiology 3/2014

01-03-2014 | Original Article

Risk Factors and Prognosis of Atrioventricular Block After Atrial Septum Defect Closure Using the Amplatzer Device

Authors: Yibin Wang, Yimin Hua, Li Li, Xiaoqin Wang, Lina Qiao, Xiaoqing Shi, Jiping Hua, Yi Qu, Dezhi Mu

Published in: Pediatric Cardiology | Issue 3/2014

Login to get access

Abstract

Amplatzer septal occluder (ASO)-induced complications have been observed. However, little attention is paid to the atrioventricular block (AVB) induced by atrial septum defect (ASD) closure using the Amplatzer device. This study aimed to analyze the risk factors and prognosis of AVB after catheter closure and to reduce the incidence of adverse events. In this study, 706 ASD patients who received closure in our division were investigated retrospectively for the relationship between AVB and factors such as age, size of the ASD (D d), diameter of the occluder (D o), diameter of the septum (D s), D o/D d ratio, and D o/D s ratio. Data distribution was evaluated with the Kolmogorov–Smirnov normality test. The Wilcoxon rank sum test was used to compare non-normal distribution data. A p value lower than 0.05 was considered significant. Of the 706 patients, six had experienced the development of AVB, giving an incidence of 0.85 %. The risk factors included younger age, larger size of the ASD, larger size of the device, and the D o/D s ratio (≥0.45). The milder AVB is, the better the prognosis. An AVB of III° and an unchanged electrocardiogram (ECG) within 3 days after the procedure are poor prognostic indicators. More attention should be paid to AVB induced by ASD closure. Younger age, size of the ASD, size of the device, and a D o/D s ratio of 0.45 or higher are the risk factors associated with AVB after closure. A timely retrieval of the device should be considered for a good prognosis.
Literature
1.
go back to reference Carlson KM, Justino H, O’Brien RE, Dimas VV, Leonard GT Jr, Pignatelli RH et al (2005) Transcatheter atrial septal defect closure: modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluder. Catheter Cardiovasc Interv 66:390–396CrossRefPubMed Carlson KM, Justino H, O’Brien RE, Dimas VV, Leonard GT Jr, Pignatelli RH et al (2005) Transcatheter atrial septal defect closure: modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluder. Catheter Cardiovasc Interv 66:390–396CrossRefPubMed
2.
go back to reference Celiker A, Ozkutlu S, Karakurt C, Karagoz T (2005) Cardiac dysrhythmias after transcatheter closure of ASD with Amplatzer device. Turk J Pediatr 47:323–326PubMed Celiker A, Ozkutlu S, Karakurt C, Karagoz T (2005) Cardiac dysrhythmias after transcatheter closure of ASD with Amplatzer device. Turk J Pediatr 47:323–326PubMed
3.
go back to reference Chessa M, Carminati M, Butera G, Bini RM, Drago M, Rosti L, Giamberti A, Pome G, Bossone E, Frigiola A (2002) Early and late complications associated with transcatheter occlusion of secundum atrial septal defect. J Am Coll Cardiol 39:1061–1065CrossRefPubMed Chessa M, Carminati M, Butera G, Bini RM, Drago M, Rosti L, Giamberti A, Pome G, Bossone E, Frigiola A (2002) Early and late complications associated with transcatheter occlusion of secundum atrial septal defect. J Am Coll Cardiol 39:1061–1065CrossRefPubMed
4.
go back to reference Dalvi B, Pinto R, Gupta A (2008) Device closure of large atrial septal defects requiring devices > or = 20 mm in small children weighing <20 kg. Catheter Cardiovasc Interv 71:679–686CrossRefPubMed Dalvi B, Pinto R, Gupta A (2008) Device closure of large atrial septal defects requiring devices > or = 20 mm in small children weighing <20 kg. Catheter Cardiovasc Interv 71:679–686CrossRefPubMed
5.
go back to reference Delaney JW, Li JS, Rhodes JF (2007) Major complications associated with transcatheter atrial septal occluder implantation: a review of the medical literature and the manufacturer and user facility device experience (MAUDE) database. Congenit Heart Dis 2:256–264CrossRefPubMed Delaney JW, Li JS, Rhodes JF (2007) Major complications associated with transcatheter atrial septal occluder implantation: a review of the medical literature and the manufacturer and user facility device experience (MAUDE) database. Congenit Heart Dis 2:256–264CrossRefPubMed
6.
go back to reference Diab K, Kenny D, Hijazi ZM (2012) Erosions, erosions, and erosions! device closure of atrial septal defects: how safe is safe? Catheter Cardiovasc Interv 80:168–174CrossRefPubMed Diab K, Kenny D, Hijazi ZM (2012) Erosions, erosions, and erosions! device closure of atrial septal defects: how safe is safe? Catheter Cardiovasc Interv 80:168–174CrossRefPubMed
7.
go back to reference DiBardino DJ, McElhinney DB, Kaza AK, Mayer JE Jr (2009) Analysis of the US food and drug administration manufacturer and user facility device experience database for adverse events involving Amplatzer septal occluder devices and comparison with the society of thoracic surgery congenital cardiac surgery database. J Thorac Cardiovasc Surg 137:1334–1341PubMedCentralCrossRefPubMed DiBardino DJ, McElhinney DB, Kaza AK, Mayer JE Jr (2009) Analysis of the US food and drug administration manufacturer and user facility device experience database for adverse events involving Amplatzer septal occluder devices and comparison with the society of thoracic surgery congenital cardiac surgery database. J Thorac Cardiovasc Surg 137:1334–1341PubMedCentralCrossRefPubMed
8.
go back to reference Gupta U, Al-anani SJ, Polimenakos AC (2011) Timing for successful surgical management of heart block after placement of an Amplatzer occlusion device for secundum atrial septal defect repair. J Thorac Cardiovasc Surg 141:1319–1321CrossRefPubMed Gupta U, Al-anani SJ, Polimenakos AC (2011) Timing for successful surgical management of heart block after placement of an Amplatzer occlusion device for secundum atrial septal defect repair. J Thorac Cardiovasc Surg 141:1319–1321CrossRefPubMed
9.
go back to reference Ho T-Y, Tsai M-C, Lee P-C, Lu J-H, Liang C-M, Laura Meng C-C, Hwang B (2005) Amplatzer septal occluder-induced arrhythmias. J Med Sci 25:105–108 Ho T-Y, Tsai M-C, Lee P-C, Lu J-H, Liang C-M, Laura Meng C-C, Hwang B (2005) Amplatzer septal occluder-induced arrhythmias. J Med Sci 25:105–108
10.
go back to reference King TD, Mills NL (1974) Nonoperative closure of atrial septal defects. Surgery 75:383–388PubMed King TD, Mills NL (1974) Nonoperative closure of atrial septal defects. Surgery 75:383–388PubMed
11.
go back to reference Masura J, Gavora P, Formanek A, Hijazi ZM (1997) Transcatheter closure of secundum atrial septal defects using the new self-centering Amplatzer septal occluder: initial human experience. Cathet Cardiovasc Diagn 42:388–393CrossRefPubMed Masura J, Gavora P, Formanek A, Hijazi ZM (1997) Transcatheter closure of secundum atrial septal defects using the new self-centering Amplatzer septal occluder: initial human experience. Cathet Cardiovasc Diagn 42:388–393CrossRefPubMed
12.
go back to reference Nehgme RA, Huddleston AR, Cheatham JP (2009) Progression to late complete atrioventricular block following Amplatzer device closure of atrial septal defect in a child. Pediatr Cardiol 30:367–370CrossRefPubMed Nehgme RA, Huddleston AR, Cheatham JP (2009) Progression to late complete atrioventricular block following Amplatzer device closure of atrial septal defect in a child. Pediatr Cardiol 30:367–370CrossRefPubMed
13.
go back to reference Sadiq M, Kazmi T, Rehman AU, Latif F, Hyder N, Qureshi SA (2012) Device closure of atrial septal defect: medium-term outcome with special reference to complications. Cardiol Young 22:71–78CrossRefPubMed Sadiq M, Kazmi T, Rehman AU, Latif F, Hyder N, Qureshi SA (2012) Device closure of atrial septal defect: medium-term outcome with special reference to complications. Cardiol Young 22:71–78CrossRefPubMed
14.
go back to reference Suda K, Raboisson MJ, Piette E, Dahdah NS, Miro J (2004) Reversible atrioventricular block associated with closure of atrial septal defects using the Amplatzer device. J Am Coll Cardiol 43:1677–1682CrossRefPubMed Suda K, Raboisson MJ, Piette E, Dahdah NS, Miro J (2004) Reversible atrioventricular block associated with closure of atrial septal defects using the Amplatzer device. J Am Coll Cardiol 43:1677–1682CrossRefPubMed
15.
go back to reference Ueda H, Yanagi S, Nakamura H, Ueno K, Gatayama R, Asou T, Yasui S (2012) Device closure of atrial septal defect: immediate and midterm results. Circ J 76:1229–1234CrossRefPubMed Ueda H, Yanagi S, Nakamura H, Ueno K, Gatayama R, Asou T, Yasui S (2012) Device closure of atrial septal defect: immediate and midterm results. Circ J 76:1229–1234CrossRefPubMed
Metadata
Title
Risk Factors and Prognosis of Atrioventricular Block After Atrial Septum Defect Closure Using the Amplatzer Device
Authors
Yibin Wang
Yimin Hua
Li Li
Xiaoqin Wang
Lina Qiao
Xiaoqing Shi
Jiping Hua
Yi Qu
Dezhi Mu
Publication date
01-03-2014
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 3/2014
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-013-0822-1

Other articles of this Issue 3/2014

Pediatric Cardiology 3/2014 Go to the issue