Skip to main content
Top
Published in: Pediatric Cardiology 2/2014

01-02-2014 | Original Article

The Ability of Stroke Volume Variation Measured by a Noninvasive Cardiac Output Monitor to Predict Fluid Responsiveness in Mechanically Ventilated Children

Authors: Ji Yeon Lee, Ji Young Kim, Chang Hyu Choi, Hong Soon Kim, Kyung Cheon Lee, Hyun Jeong Kwak

Published in: Pediatric Cardiology | Issue 2/2014

Login to get access

Abstract

Continuous noninvasive cardiac output monitoring (NICOM) is a clinically useful tool in the pediatric setting. This study compared the ability of stroke volume variation (SVV) measured by NICOM with that of respiratory variations in the velocity of aortic blood flow (△Vpeak) and central venous pressure (CVP) to predict of fluid responsiveness in mechanically ventilated children after ventricular septal defect repair. The study investigated 26 mechanically ventilated children after the completion of surgery. At 30 min after their arrival in an intensive care unit, a colloid solution of 10 ml/kg was administrated for volume expansion. Hemodynamic variables, including CVP, stroke volume, and △Vpeak in addition to cardiac output and SVV in NICOM were measured before and 10 min after volume expansion. The patients with a stroke volume increase of more than 15 % after volume expansion were defined as responders. The 26 patients in the study consisted of 13 responders and 13 nonresponders. Before volume expansion, △Vpeak and SVV were higher in the responders (both p values <0.001). The areas under the receiver operating characteristic curves of △Vpeak, SVV, and CVP were respectively 0.956 (95 % CI 0.885–1.00), 0.888 (95 % CI 0.764–1.00), and 0.331 (95 % CI 0.123–0.540). This study showed that SVV by NICOM and △Vpeak by echocardiography, but not CVP, reliably predicted fluid responsiveness during mechanical ventilation after ventricular septal defect repair in children.
Literature
1.
go back to reference Ballestero Y, López-Herce J, Urbano J et al (2011) Measurement of cardiac output in children by bioreactance. Pediatr Cardiol 32:469–472CrossRefPubMed Ballestero Y, López-Herce J, Urbano J et al (2011) Measurement of cardiac output in children by bioreactance. Pediatr Cardiol 32:469–472CrossRefPubMed
2.
go back to reference Choi DY, Kwak HJ, Park HY, Kim YB, Choi CH, Lee JY (2010) Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect. Pediatr Cardiol 31:1166–1170CrossRefPubMed Choi DY, Kwak HJ, Park HY, Kim YB, Choi CH, Lee JY (2010) Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect. Pediatr Cardiol 31:1166–1170CrossRefPubMed
3.
go back to reference Chung E, Cannesson M (2012) Using noninvasive dynamic parameters of fluid responsiveness in children: there is still much to learn. J Clin Monit Comput 26:153–155CrossRefPubMed Chung E, Cannesson M (2012) Using noninvasive dynamic parameters of fluid responsiveness in children: there is still much to learn. J Clin Monit Comput 26:153–155CrossRefPubMed
4.
go back to reference Conway DH, Hussain OA, Gall I (2013) A comparison of noninvasive bioreactance with oesophageal Doppler estimation of stroke volume during open abdominal surgery: an observational study. Eur J Anaesthesiol 30:501–508CrossRefPubMed Conway DH, Hussain OA, Gall I (2013) A comparison of noninvasive bioreactance with oesophageal Doppler estimation of stroke volume during open abdominal surgery: an observational study. Eur J Anaesthesiol 30:501–508CrossRefPubMed
5.
go back to reference de Souza Pereira, Neto E, Grousson S, Duflo F et al (2011) Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography. Br J Anaesth 106:856–864CrossRef de Souza Pereira, Neto E, Grousson S, Duflo F et al (2011) Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography. Br J Anaesth 106:856–864CrossRef
6.
go back to reference Durand P, Chevret L, Essouri S, Haas V, Devictor D (2008) Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children. Intensive Care Med 34:888–894CrossRefPubMed Durand P, Chevret L, Essouri S, Haas V, Devictor D (2008) Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children. Intensive Care Med 34:888–894CrossRefPubMed
7.
8.
go back to reference Hanley JA, McNeil BJ (1982) The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 143:29–36CrossRefPubMed Hanley JA, McNeil BJ (1982) The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 143:29–36CrossRefPubMed
9.
go back to reference Keren H, Burkhoff D, Squara P (2007) Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol 293:H583–H589CrossRefPubMed Keren H, Burkhoff D, Squara P (2007) Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol 293:H583–H589CrossRefPubMed
10.
go back to reference Lafanechère A, Albaladejo P, Raux M et al (2006) Cardiac output measurement during infrarenal aortic surgery: echo-esophageal Doppler versus thermodilution catheter. J Cardiothorac Vasc Anesth 20:26–30CrossRefPubMed Lafanechère A, Albaladejo P, Raux M et al (2006) Cardiac output measurement during infrarenal aortic surgery: echo-esophageal Doppler versus thermodilution catheter. J Cardiothorac Vasc Anesth 20:26–30CrossRefPubMed
11.
go back to reference Loupec T, Nanadoumgar H, Frasca D et al (2011) Pleth variability index predicts fluid responsiveness in critically ill patients. Crit Care Med 39:294–299CrossRefPubMed Loupec T, Nanadoumgar H, Frasca D et al (2011) Pleth variability index predicts fluid responsiveness in critically ill patients. Crit Care Med 39:294–299CrossRefPubMed
12.
go back to reference Marik PE, Baram M, Vahid B (2008) Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 134:172–178CrossRefPubMed Marik PE, Baram M, Vahid B (2008) Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 134:172–178CrossRefPubMed
13.
go back to reference Marik PE, Cavallazzi R, Vasu T, Hirani A (2009) Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 37:2642–2647CrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A (2009) Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 37:2642–2647CrossRefPubMed
14.
go back to reference Obuchowski NA, McClish DK (1997) Sample size determination for diagnostic accuracy studies involving binormal ROC curve indices. Stat Med 16:1529–1542CrossRefPubMed Obuchowski NA, McClish DK (1997) Sample size determination for diagnostic accuracy studies involving binormal ROC curve indices. Stat Med 16:1529–1542CrossRefPubMed
15.
go back to reference Renner J, Gruenewald M, Meybohm P et al (2008) Effect of elevated PEEP on dynamic variables of fluid responsiveness in a pediatric animal model. Paediatr Anaesth 18:1170–1177PubMed Renner J, Gruenewald M, Meybohm P et al (2008) Effect of elevated PEEP on dynamic variables of fluid responsiveness in a pediatric animal model. Paediatr Anaesth 18:1170–1177PubMed
16.
go back to reference Renner J, Cavus E, Meybohm P et al (2008) Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal model. Acta Anaesthesiol Scand 52:374–380CrossRefPubMed Renner J, Cavus E, Meybohm P et al (2008) Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal model. Acta Anaesthesiol Scand 52:374–380CrossRefPubMed
17.
go back to reference Renner J, Broch O, Gruenewald M et al (2011) Noninvasive prediction of fluid responsiveness in infants using Pleth variability index. Anaesthesia 66:582–589CrossRefPubMed Renner J, Broch O, Gruenewald M et al (2011) Noninvasive prediction of fluid responsiveness in infants using Pleth variability index. Anaesthesia 66:582–589CrossRefPubMed
18.
go back to reference Renner J, Broch O, Duetschke P et al (2012) Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery. Br J Anaesth 108:108–115CrossRefPubMed Renner J, Broch O, Duetschke P et al (2012) Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery. Br J Anaesth 108:108–115CrossRefPubMed
19.
go back to reference Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C (2007) Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med 33:1191–1194CrossRefPubMed Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C (2007) Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med 33:1191–1194CrossRefPubMed
20.
go back to reference Vistisen ST, Koefoed-Nielsen J, Larsson A (2010) Should dynamic parameters for prediction of fluid responsiveness be indexed to the tidal volume? Acta Anaesthesiol Scand 54:191–198CrossRefPubMed Vistisen ST, Koefoed-Nielsen J, Larsson A (2010) Should dynamic parameters for prediction of fluid responsiveness be indexed to the tidal volume? Acta Anaesthesiol Scand 54:191–198CrossRefPubMed
21.
go back to reference Weisz DE, Jain A, McNamara PJ, EL-Khuffash A (2012) Noninvasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography. Neonatology 102:61–67CrossRefPubMed Weisz DE, Jain A, McNamara PJ, EL-Khuffash A (2012) Noninvasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography. Neonatology 102:61–67CrossRefPubMed
Metadata
Title
The Ability of Stroke Volume Variation Measured by a Noninvasive Cardiac Output Monitor to Predict Fluid Responsiveness in Mechanically Ventilated Children
Authors
Ji Yeon Lee
Ji Young Kim
Chang Hyu Choi
Hong Soon Kim
Kyung Cheon Lee
Hyun Jeong Kwak
Publication date
01-02-2014
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 2/2014
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-013-0772-7

Other articles of this Issue 2/2014

Pediatric Cardiology 2/2014 Go to the issue