Skip to main content
Top
Published in: Pediatric Cardiology 5/2013

01-06-2013 | Original Article

Infant Cardiac Magnetic Resonance Imaging Using Oscillatory Ventilation: Safe and Effective

Authors: Alicia H. Chaves, Joseph R. Cava, Pippa Simpson, George M. Hoffman, Margaret M. Samyn

Published in: Pediatric Cardiology | Issue 5/2013

Login to get access

Abstract

Cardiac magnetic resonance imaging (CMR) for infants and young children typically requires sedation. General anesthesia with controlled ventilation can eliminate motion artifact with breath-holds during imaging to limit respiratory artifact, but these may lead to atelectasis or other complications. High-frequency oscillatory ventilation (HFOV) provides ventilation with near-constant mean airway pressure and minimal movement of chest wall and diaphragm, thus obviating the need for breath-holding. Clinical data were collected for 8 infants who underwent CMR with HFOV and 8 controls who underwent CMR with conventional ventilator and breath-hold technique. Data included demographic information, adverse events, and scan-acquisition time. Studies were reviewed for image quality by two cardiologists who were blinded to type of ventilation. There were no significant differences in patient characteristics between the two groups. There was no significant difference in average image quality for cine short-axis or black blood imaging. Total CMR scan time was not significantly different between groups, but the short-axis cine stack was acquired more quickly in the HFOV group (1.8 ± 0.8 vs. 5.0 ± 3.6 min). There were no adverse events in the HFOV group, but scans were terminated early for two patients in the conventional ventilator group. HFOV during CMR is feasible and well tolerated. Image quality is equivalent to that obtained with conventional ventilation with breath-holding technique and allows shorter cine scan times for some sequences.
Literature
1.
go back to reference Blitman NM, Lee HK, Jain VR, Viencio AG, Girshin M, Haramati LB (2007) Pulmonary atelectasis in children anesthetized for cardiothoracic MR: evaluation of risk factors. J Comput Assist Tomogr 31:789–794PubMedCrossRef Blitman NM, Lee HK, Jain VR, Viencio AG, Girshin M, Haramati LB (2007) Pulmonary atelectasis in children anesthetized for cardiothoracic MR: evaluation of risk factors. J Comput Assist Tomogr 31:789–794PubMedCrossRef
2.
go back to reference Bojan M, Gioanni S, Mauriat P, Pouard P (2001) High-frequency oscillatory ventilation and short-term outcome in neonates and infants undergoing cardiac surgery: a propensity score analysis. Crit Care 15:R259CrossRef Bojan M, Gioanni S, Mauriat P, Pouard P (2001) High-frequency oscillatory ventilation and short-term outcome in neonates and infants undergoing cardiac surgery: a propensity score analysis. Crit Care 15:R259CrossRef
3.
go back to reference Dorfman AL, Odegard KC, Powell AJ, Laussen PC, Geva T (2007) Risk factors for adverse events during cardiovascular magnetic resonance in congenital heart disease. J Cardiovasc Magn Reson 9:793–798PubMedCrossRef Dorfman AL, Odegard KC, Powell AJ, Laussen PC, Geva T (2007) Risk factors for adverse events during cardiovascular magnetic resonance in congenital heart disease. J Cardiovasc Magn Reson 9:793–798PubMedCrossRef
4.
go back to reference Fogel MA, Weinberg PM, Parave E, Harris C, Montenegro L, Harris MA et al (2008) Deep sedation for cardiac magnetic resonance imaging: a comparison with cardiac anesthesia. J Pediatr 152:534–539PubMedCrossRef Fogel MA, Weinberg PM, Parave E, Harris C, Montenegro L, Harris MA et al (2008) Deep sedation for cardiac magnetic resonance imaging: a comparison with cardiac anesthesia. J Pediatr 152:534–539PubMedCrossRef
5.
go back to reference Fogel MA, Pawlowski TW, Harris MA, Whitehead KK, Keller MS, Wilson J et al (2011) Comparison and usefulness of cardiac magnetic resonance versus computed tomography in infants six months of age or younger with aortic arch anomalies without deep sedation or anesthesia. Am J Cardiol 108:120–125PubMedCrossRef Fogel MA, Pawlowski TW, Harris MA, Whitehead KK, Keller MS, Wilson J et al (2011) Comparison and usefulness of cardiac magnetic resonance versus computed tomography in infants six months of age or younger with aortic arch anomalies without deep sedation or anesthesia. Am J Cardiol 108:120–125PubMedCrossRef
6.
go back to reference Girshin M, Shapiro V, Rhee A, Ginsberg S, Inchiosa MA (2009) Increased risk of general anesthesia for high-risk patients undergoing magnetic resonance imaging. J Comput Assist Tomogr 33:312–315PubMedCrossRef Girshin M, Shapiro V, Rhee A, Ginsberg S, Inchiosa MA (2009) Increased risk of general anesthesia for high-risk patients undergoing magnetic resonance imaging. J Comput Assist Tomogr 33:312–315PubMedCrossRef
7.
go back to reference Hoffman GM, Ruiz FJ, Johnson R, Scott JP, Taylor SP (2010) High frequency oscillatory ventilation for anesthesia for cardiac MRI in neonates and infants. In: Abstract presented at proceedings of the 2010 annual meeting of the American society anesthesiologists Hoffman GM, Ruiz FJ, Johnson R, Scott JP, Taylor SP (2010) High frequency oscillatory ventilation for anesthesia for cardiac MRI in neonates and infants. In: Abstract presented at proceedings of the 2010 annual meeting of the American society anesthesiologists
8.
9.
go back to reference Lutterby G, Wattjes MP, Doerr D, Fischer NJ, Gieske J, Schild HH (2007) Atelectasis in children undergoing either propofol infusion or positive pressure ventilation anesthesia for magnetic resonance imaging. Pediatr Anesth 17:121–125CrossRef Lutterby G, Wattjes MP, Doerr D, Fischer NJ, Gieske J, Schild HH (2007) Atelectasis in children undergoing either propofol infusion or positive pressure ventilation anesthesia for magnetic resonance imaging. Pediatr Anesth 17:121–125CrossRef
10.
go back to reference Malviya S, Voepel-Lewis T, Eldevik OP, Rockwell DT, Wong JH, Tait AR (2000) Sedation and general anesthesia in children undergoing MRI and CT: adverse events and outcomes. Br J Anesth 84(6):743–748CrossRef Malviya S, Voepel-Lewis T, Eldevik OP, Rockwell DT, Wong JH, Tait AR (2000) Sedation and general anesthesia in children undergoing MRI and CT: adverse events and outcomes. Br J Anesth 84(6):743–748CrossRef
11.
go back to reference Odegard KC, Dinardo JA, Tsai-Goodman B, Powell AJ, Geva T, Laussen PC (2004) Anaesthesia considerations for cardiac MRI in infants and small children. Pediatr Anesth 14:471–476CrossRef Odegard KC, Dinardo JA, Tsai-Goodman B, Powell AJ, Geva T, Laussen PC (2004) Anaesthesia considerations for cardiac MRI in infants and small children. Pediatr Anesth 14:471–476CrossRef
12.
go back to reference Sarikouch S, Schaeffler R, Koperich H, Dongas A, Haas NA, Beerbaum P (2009) Cardiovascular magnetic resonance imaging for intensive care infants: safe and effective? Pediatr Cardiol 30:146–152PubMedCrossRef Sarikouch S, Schaeffler R, Koperich H, Dongas A, Haas NA, Beerbaum P (2009) Cardiovascular magnetic resonance imaging for intensive care infants: safe and effective? Pediatr Cardiol 30:146–152PubMedCrossRef
13.
go back to reference Tsai-Goodman B, Geva T, Odegard KC, Sena LM, Powell AJ (2004) Clinical role, accuracy, and technical aspects of cardiovascular magnetic resonance imaging in infants. Am J Cardiol 94:69–74PubMedCrossRef Tsai-Goodman B, Geva T, Odegard KC, Sena LM, Powell AJ (2004) Clinical role, accuracy, and technical aspects of cardiovascular magnetic resonance imaging in infants. Am J Cardiol 94:69–74PubMedCrossRef
14.
go back to reference Tusman G, Bohm SH, Tempra A, Melkun Garcia E, Turhetto E et al (2003) Effects of recruitment maneuver on atelectasis in anesthetized children. Anesthesiology 98(1):14–22PubMedCrossRef Tusman G, Bohm SH, Tempra A, Melkun Garcia E, Turhetto E et al (2003) Effects of recruitment maneuver on atelectasis in anesthetized children. Anesthesiology 98(1):14–22PubMedCrossRef
15.
go back to reference Ventre KM, Arnold JH (2004) High frequency oscillatory ventilation in acute respiratory failure. Paediatr Respir Rev 5(4):323–332PubMedCrossRef Ventre KM, Arnold JH (2004) High frequency oscillatory ventilation in acute respiratory failure. Paediatr Respir Rev 5(4):323–332PubMedCrossRef
16.
go back to reference Windram J, Grosse-Wortmann L, Shiriat M, Greer M, Crawford MW, Yoo S (2012) Cardiovascular MRI without sedation or general anesthesia using a feed-and-sleep technique in neonates and infants. Pediatr Radiol 42:183–187PubMedCrossRef Windram J, Grosse-Wortmann L, Shiriat M, Greer M, Crawford MW, Yoo S (2012) Cardiovascular MRI without sedation or general anesthesia using a feed-and-sleep technique in neonates and infants. Pediatr Radiol 42:183–187PubMedCrossRef
Metadata
Title
Infant Cardiac Magnetic Resonance Imaging Using Oscillatory Ventilation: Safe and Effective
Authors
Alicia H. Chaves
Joseph R. Cava
Pippa Simpson
George M. Hoffman
Margaret M. Samyn
Publication date
01-06-2013
Publisher
Springer-Verlag
Published in
Pediatric Cardiology / Issue 5/2013
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-013-0630-7

Other articles of this Issue 5/2013

Pediatric Cardiology 5/2013 Go to the issue