Skip to main content
Top
Published in: Pediatric Cardiology 1/2012

01-01-2012 | Original Article

Radiation Exposure in Children During the Current Era of Pediatric Cardiac Intervention

Authors: Maiy Hamdy El Sayed, Alaa Mahmoud Roushdy, Hala El Farghaly, Ahmad El Sherbini

Published in: Pediatric Cardiology | Issue 1/2012

Login to get access

Abstract

Cardiac catheterizations are among the X-ray procedures with the highest patient radiation dose and therefore are of great concern in pediatric settings. This study aimed to evaluate factors that influence variability of X-ray exposure in children with congenital heart diseases during cardiac catheterization. The study included 107 children who underwent either diagnostic (n = 46) or interventional (n = 61) procedures. A custom-made sheet for patient and procedural characteristics was designed. Data were collected, and different correlations were applied to determine factors that influence variability of X-ray exposure. The flouroscopy time (FT) differed significantly between the diagnostic (8.9 ± 6.3 min) and intervention (12.8 ± 9.98 min) groups (P = 0.032). The mean dose–area product (DAP) differed significantly between the two groups (3.775 ± 2.5 Gy/cm2 vs. 13.239 ± 15.4 Gy/cm2; P = 0.003). The highest DAP was during left anterior oblique (LAO) cranial 30° angulation (2.8 Gy/cm2/4 s cine). The mean cumulative dose (CD) was 0.053 Gy in diagnostic cases and 0.48 Gy in intervention cases. The effective dose was 5.97 ± 7.05 mSv for theraputic procedures compared with 3.42 ± 3.64 mSv for diagnostic procedures. The FT correlated significantly with both the DAP (r = 0.718; P < 0.001) and the CD (r = 0.701; P < 0.001). Other correlations were reported. An increasing number of therapeutic catheterization procedures are being performed for children. The justification for these procedures is evident because they avoid complicated surgery. However, the complexity of these procedures results in higher radiation exposures.
Literature
1.
go back to reference Ait-Ali L, Andreassi MG, Foffa I (2010) Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease. Heart 96:269–274PubMedCrossRef Ait-Ali L, Andreassi MG, Foffa I (2010) Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease. Heart 96:269–274PubMedCrossRef
2.
go back to reference Allen HD, Driscoll DJ, Fricker FJ et al (1991) Guidelines for pediatric therapeutic cardiac catheterization: a statement for health professionals from the Committee on Congenital Cardiac Defects of the Council on Cardiovascular Disease in the Young, the American Heart Association. Circulation 84:2248–2258PubMed Allen HD, Driscoll DJ, Fricker FJ et al (1991) Guidelines for pediatric therapeutic cardiac catheterization: a statement for health professionals from the Committee on Congenital Cardiac Defects of the Council on Cardiovascular Disease in the Young, the American Heart Association. Circulation 84:2248–2258PubMed
3.
go back to reference Bacher K, Bogaert E, Lapere R et al (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89PubMedCrossRef Bacher K, Bogaert E, Lapere R et al (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89PubMedCrossRef
4.
go back to reference Baldazzi G, Corazza I, Rossi PL et al (2002) In vivo effectiveness of gadolinium filter for paediatric cardiac angiography in terms of image quality and radiation exposure. Phys Med 18:109–113 Baldazzi G, Corazza I, Rossi PL et al (2002) In vivo effectiveness of gadolinium filter for paediatric cardiac angiography in terms of image quality and radiation exposure. Phys Med 18:109–113
5.
6.
go back to reference Boothroyd A, McDonald E, Moores BM et al (1997) Radiation exposure to children during cardiac catheterization. Br J Radiol 70:180–185PubMed Boothroyd A, McDonald E, Moores BM et al (1997) Radiation exposure to children during cardiac catheterization. Br J Radiol 70:180–185PubMed
7.
go back to reference Chida K, Saito H, Otani H et al (2006) Relationship between fluoroscopic time, dose–area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. AJR Am J Roentgenol 186:774–778PubMedCrossRef Chida K, Saito H, Otani H et al (2006) Relationship between fluoroscopic time, dose–area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. AJR Am J Roentgenol 186:774–778PubMedCrossRef
8.
go back to reference Chida K, Ohno T, Kakizaki S et al (2010) Radiation dose to the pediatric cardiac catheterization and intervention patient. AJR Am J Roentgenol 195:1175–1179PubMedCrossRef Chida K, Ohno T, Kakizaki S et al (2010) Radiation dose to the pediatric cardiac catheterization and intervention patient. AJR Am J Roentgenol 195:1175–1179PubMedCrossRef
9.
go back to reference Guibelalde E, Vano E, Gonzalez L et al (2003) Practical aspects for the evaluation of skin doses in interventional cardiology using a new slow film. Br J Radiol 76:332–336PubMedCrossRef Guibelalde E, Vano E, Gonzalez L et al (2003) Practical aspects for the evaluation of skin doses in interventional cardiology using a new slow film. Br J Radiol 76:332–336PubMedCrossRef
10.
go back to reference Justino H (2006) The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dose. Pediatr Radiol 36(Suppl 2):146–153PubMedCrossRef Justino H (2006) The ALARA concept in pediatric cardiac catheterization: techniques and tactics for managing radiation dose. Pediatr Radiol 36(Suppl 2):146–153PubMedCrossRef
11.
go back to reference Kuon E, Dahm J, Empen K et al (2004) Identification of less-irradiating tube angulations in invasive cardiology. J Am Coll Cardiol 44:1420–1428PubMedCrossRef Kuon E, Dahm J, Empen K et al (2004) Identification of less-irradiating tube angulations in invasive cardiology. J Am Coll Cardiol 44:1420–1428PubMedCrossRef
12.
go back to reference Larrazet F, Dibie A, Philippe F et al (2003) Factors influencing fluoroscopy time and dose–area product values during ad hoc one-vessel percutaneous coronary angioplasty. Br J Radiol 76:473–477PubMedCrossRef Larrazet F, Dibie A, Philippe F et al (2003) Factors influencing fluoroscopy time and dose–area product values during ad hoc one-vessel percutaneous coronary angioplasty. Br J Radiol 76:473–477PubMedCrossRef
13.
14.
go back to reference Li LB, Kai M, Kusama T (2001) Radiation exposure to patients during paediatric cardiac catheterization. Radiat Prot Dosimetry 94:323–327PubMed Li LB, Kai M, Kusama T (2001) Radiation exposure to patients during paediatric cardiac catheterization. Radiat Prot Dosimetry 94:323–327PubMed
15.
go back to reference Mesbahi A, Aslanabadi N (2008) A study on patients’ radiation doses from interventional cardiac procedures in Tabriz, Iran. Radiat Protect Dosimetry 132:375–380CrossRef Mesbahi A, Aslanabadi N (2008) A study on patients’ radiation doses from interventional cardiac procedures in Tabriz, Iran. Radiat Protect Dosimetry 132:375–380CrossRef
16.
go back to reference Miller DL, Balter S, Patricia E et al (2003) Radiation doses in interventional radiology procedures: The RAD-IR Study Part I: overall measures of dose. JVIR 14:711–727PubMedCrossRef Miller DL, Balter S, Patricia E et al (2003) Radiation doses in interventional radiology procedures: The RAD-IR Study Part I: overall measures of dose. JVIR 14:711–727PubMedCrossRef
17.
go back to reference Onnasch DGW, Schroder FK, Fischer G et al (2007) Diagnostic reference levels and effective dose in paediatric cardiac catheterization. Br J Radiol 80:177–183PubMedCrossRef Onnasch DGW, Schroder FK, Fischer G et al (2007) Diagnostic reference levels and effective dose in paediatric cardiac catheterization. Br J Radiol 80:177–183PubMedCrossRef
18.
go back to reference Rassow J, Schmaltz AA, Hentrich F et al (2000) Effective doses to patients from paediatric cardiac catheterization. Br J Radiol 73:172–183PubMed Rassow J, Schmaltz AA, Hentrich F et al (2000) Effective doses to patients from paediatric cardiac catheterization. Br J Radiol 73:172–183PubMed
19.
go back to reference Ross RD, Joshi V, Carravallah DJ et al (1997) Reduced radiation during cardiac catheterization of infants using acquisition zoom technology. Am J Cardiol 79:691–693PubMedCrossRef Ross RD, Joshi V, Carravallah DJ et al (1997) Reduced radiation during cardiac catheterization of infants using acquisition zoom technology. Am J Cardiol 79:691–693PubMedCrossRef
20.
go back to reference ICRP (1991) Recommendations of the International Commission on Radiological Protection. Publication 60. Pergamon Press, Oxford ICRP (1991) Recommendations of the International Commission on Radiological Protection. Publication 60. Pergamon Press, Oxford
21.
go back to reference Schueler BA, Julsrud PR, Gray JE et al (1994) Radiation exposure and efficacy of exposure-reduction techniques during cardiac catheterization in children. Am J Roentgenol 162:173–177 Schueler BA, Julsrud PR, Gray JE et al (1994) Radiation exposure and efficacy of exposure-reduction techniques during cardiac catheterization in children. Am J Roentgenol 162:173–177
22.
go back to reference Stratis A, Anthopoulos P, Gavaliatsis I et al (2009) Patient dose in cardiac radiology. Hellenic J Cardiol 50:17–25PubMed Stratis A, Anthopoulos P, Gavaliatsis I et al (2009) Patient dose in cardiac radiology. Hellenic J Cardiol 50:17–25PubMed
23.
go back to reference Tsapaki V, Kottou S, Vano E et al (2003) Patient dose values in a dedicated Greek cardiac centre. Br J Radiol 76:726–730PubMedCrossRef Tsapaki V, Kottou S, Vano E et al (2003) Patient dose values in a dedicated Greek cardiac centre. Br J Radiol 76:726–730PubMedCrossRef
24.
go back to reference Verghese GR, McElhinney DB, Bergersen L (2010) Characterization of high levels of radiation exposure in a large volume pediatric cardiac catheterization lab. J Am Coll Cardiol 55:A211. E1998. doi:10.1016/S0735-1097(10)61999-7 Verghese GR, McElhinney DB, Bergersen L (2010) Characterization of high levels of radiation exposure in a large volume pediatric cardiac catheterization lab. J Am Coll Cardiol 55:A211. E1998. doi:10.​1016/​S0735-1097(10)61999-7
25.
26.
go back to reference Žontar D, Kuhelj D, Škrk D et al (2010) Patient peak skin doses from cardiac interventional procedures. Radiat Prot Dosimetry 139:262–265PubMedCrossRef Žontar D, Kuhelj D, Škrk D et al (2010) Patient peak skin doses from cardiac interventional procedures. Radiat Prot Dosimetry 139:262–265PubMedCrossRef
Metadata
Title
Radiation Exposure in Children During the Current Era of Pediatric Cardiac Intervention
Authors
Maiy Hamdy El Sayed
Alaa Mahmoud Roushdy
Hala El Farghaly
Ahmad El Sherbini
Publication date
01-01-2012
Publisher
Springer-Verlag
Published in
Pediatric Cardiology / Issue 1/2012
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-011-0064-z

Other articles of this Issue 1/2012

Pediatric Cardiology 1/2012 Go to the issue