Skip to main content
Top
Published in: Calcified Tissue International 2/2017

Open Access 01-08-2017 | Original Research

The Reliability of a Semi-automated Algorithm for Detection of Cortical Interruptions in Finger Joints on High Resolution CT Compared to MicroCT

Authors: M. Peters, A. Scharmga, A. van Tubergen, J. Arts, D. Loeffen, R. Weijers, B. van Rietbergen, P. Geusens, J. P. van den Bergh

Published in: Calcified Tissue International | Issue 2/2017

Login to get access

Abstract

We developed a semi-automated algorithm for the detection of cortical interruptions in finger joints using high-resolution peripheral quantitative computed tomography (HR-pQCT). Here, we tested its reliability compared to microCT (µCT) as gold standard. Nineteen joints of 10 female anatomic index fingers were imaged by HR-pQCT and µCT (82 and 18 µm isotropic voxel sizes, respectively). The algorithm was applied for detection of cortical interruptions of different minimum diameters (range >0.16 to >0.50 mm). Reliability was tested at the joint level with intra-class correlation coefficient (ICC) for the number of interruptions and interruption surface, and at the level of a single interruption for matching between HR-pQCT and µCT with a fixed interruption diameter (>0.10 mm) on µCT. The positive predictive value (PPV0.10mm) and sensitivity0.10mm were evaluated. The mean number of interruptions per joint depended on the diameter cut-off and ranged from 3.4 to 53.5 on HR-pQCT and from 1.8 to 45.1 on µCT for interruptions >0.50 to >0.16 mm, respectively. Reliability at the joint level was almost perfect (ICC ≥0.81) for both the number and surface of interruptions >0.16 and >0.33 mm. As expected, the PPV0.10mm increased with increasing interruption diameter from 84.9 to 100%, for interruptions >0.16 and >0.50 mm, respectively. However, the sensitivity0.10mm decreased with increasing interruption diameter from 62.4 to 4.7%. This semi-automated algorithm for HR-pQCT in finger joints performed best for the detection of cortical interruptions with a minimum diameter of >0.16 or >0.33 mm, showing almost perfect reliability at the joint level and interruptions matched with those on µCT.
Literature
2.
go back to reference Geusens P, van den Bergh J (2014) Bone erosions in rheumatoid arthritis. Rheumatology 53(1):4–5 PubMed PMID: 24196387.CrossRefPubMed Geusens P, van den Bergh J (2014) Bone erosions in rheumatoid arthritis. Rheumatology 53(1):4–5 PubMed PMID: 24196387.CrossRefPubMed
3.
go back to reference Baillet A, Gaujoux-Viala C, Mouterde G, Pham T, Tebib J, Saraux A et al (2011) Comparison of the efficacy of sonography, magnetic resonance imaging and conventional radiography for the detection of bone erosions in rheumatoid arthritis patients: a systematic review and meta-analysis. Rheumatology 50(6):1137–1147CrossRefPubMed Baillet A, Gaujoux-Viala C, Mouterde G, Pham T, Tebib J, Saraux A et al (2011) Comparison of the efficacy of sonography, magnetic resonance imaging and conventional radiography for the detection of bone erosions in rheumatoid arthritis patients: a systematic review and meta-analysis. Rheumatology 50(6):1137–1147CrossRefPubMed
4.
go back to reference Dohn UM, Ejbjerg BJ, Hasselquist M, Narvestad E, Moller J, Thomsen HS et al (2008) Detection of bone erosions in rheumatoid arthritis wrist joints with magnetic resonance imaging, computed tomography and radiography. Arthr Res Ther 10(1):R25CrossRef Dohn UM, Ejbjerg BJ, Hasselquist M, Narvestad E, Moller J, Thomsen HS et al (2008) Detection of bone erosions in rheumatoid arthritis wrist joints with magnetic resonance imaging, computed tomography and radiography. Arthr Res Ther 10(1):R25CrossRef
5.
go back to reference Geusens P, Chapurlat R, Schett G, Ghasem-Zadeh A, Seeman E, de Jong J et al (2014) High-resolution in vivo imaging of bone and joints: a window to microarchitecture. Nat Rev Rheumatol 10(5):304–313CrossRefPubMed Geusens P, Chapurlat R, Schett G, Ghasem-Zadeh A, Seeman E, de Jong J et al (2014) High-resolution in vivo imaging of bone and joints: a window to microarchitecture. Nat Rev Rheumatol 10(5):304–313CrossRefPubMed
6.
go back to reference Ejbjerg B, Narvestad E, Rostrup E, Szkudlarek M, Jacobsen S, Thomsen HS et al (2004) Magnetic resonance imaging of wrist and finger joints in healthy subjects occasionally shows changes resembling erosions and synovitis as seen in rheumatoid arthritis. Arthr Rheum 50(4):1097–1106CrossRef Ejbjerg B, Narvestad E, Rostrup E, Szkudlarek M, Jacobsen S, Thomsen HS et al (2004) Magnetic resonance imaging of wrist and finger joints in healthy subjects occasionally shows changes resembling erosions and synovitis as seen in rheumatoid arthritis. Arthr Rheum 50(4):1097–1106CrossRef
7.
go back to reference Boutroy S, Bouxsein ML, Munoz F, Delmas PD (2005) In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography. J Clin Endocrinol Metab 90(12):6508–6515CrossRefPubMed Boutroy S, Bouxsein ML, Munoz F, Delmas PD (2005) In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography. J Clin Endocrinol Metab 90(12):6508–6515CrossRefPubMed
8.
go back to reference Stach CM, Bauerle M, Englbrecht M, Kronke G, Engelke K, Manger B et al (2010) Periarticular bone structure in rheumatoid arthritis patients and healthy individuals assessed by high-resolution computed tomography. Arthr Rheum 62(2):330–339 PubMed PMID: 20112404. Stach CM, Bauerle M, Englbrecht M, Kronke G, Engelke K, Manger B et al (2010) Periarticular bone structure in rheumatoid arthritis patients and healthy individuals assessed by high-resolution computed tomography. Arthr Rheum 62(2):330–339 PubMed PMID: 20112404.
9.
go back to reference Srikhum W, Virayavanich W, Burghardt AJ, Yu A, Link TM, Imboden JB et al (2013) Quantitative and semiquantitative bone erosion assessment on high-resolution peripheral quantitative computed tomography in rheumatoid arthritis. J Rheumatol 40(4):408–416CrossRefPubMed Srikhum W, Virayavanich W, Burghardt AJ, Yu A, Link TM, Imboden JB et al (2013) Quantitative and semiquantitative bone erosion assessment on high-resolution peripheral quantitative computed tomography in rheumatoid arthritis. J Rheumatol 40(4):408–416CrossRefPubMed
10.
go back to reference Albrecht A, Finzel S, Englbrecht M, Rech J, Hueber A, Schlechtweg P et al (2013) The structural basis of MRI bone erosions: an assessment by microCT. Ann Rheum Dis 72(8):1351–1357CrossRefPubMed Albrecht A, Finzel S, Englbrecht M, Rech J, Hueber A, Schlechtweg P et al (2013) The structural basis of MRI bone erosions: an assessment by microCT. Ann Rheum Dis 72(8):1351–1357CrossRefPubMed
11.
go back to reference Finzel S, Ohrndorf S, Englbrecht M, Stach C, Messerschmidt J, Schett G et al (2011) A detailed comparative study of high-resolution ultrasound and micro-computed tomography for detection of arthritic bone erosions. Arthr Rheum 63(5):1231–1236CrossRef Finzel S, Ohrndorf S, Englbrecht M, Stach C, Messerschmidt J, Schett G et al (2011) A detailed comparative study of high-resolution ultrasound and micro-computed tomography for detection of arthritic bone erosions. Arthr Rheum 63(5):1231–1236CrossRef
12.
go back to reference Scharmga A, Peters M, van Tubergen A, van den Bergh J, de Jong J, Loeffen D et al (2016) Visual detection of cortical breaks in hand joints: reliability and validity of high-resolution peripheral quantitative CT compared to microCT. BMC Musculoskelet Disord 17(1):271CrossRefPubMedPubMedCentral Scharmga A, Peters M, van Tubergen A, van den Bergh J, de Jong J, Loeffen D et al (2016) Visual detection of cortical breaks in hand joints: reliability and validity of high-resolution peripheral quantitative CT compared to microCT. BMC Musculoskelet Disord 17(1):271CrossRefPubMedPubMedCentral
13.
go back to reference Fouque-Aubert A, Boutroy S, Marotte H, Vilayphiou N, Bacchetta J, Miossec P et al (2010) Assessment of hand bone loss in rheumatoid arthritis by high-resolution peripheral quantitative CT. Ann Rheum Dis 69(9):1671–1676CrossRefPubMed Fouque-Aubert A, Boutroy S, Marotte H, Vilayphiou N, Bacchetta J, Miossec P et al (2010) Assessment of hand bone loss in rheumatoid arthritis by high-resolution peripheral quantitative CT. Ann Rheum Dis 69(9):1671–1676CrossRefPubMed
14.
go back to reference Krause M, Museyko O, Breer S, Wulff B, Duckstein C, Vettorazzi E et al (2014) Accuracy of trabecular structure by HR-pQCT compared to gold standard muCT in the radius and tibia of patients with osteoporosis and long-term bisphosphonate therapy. Osteoporos Int 25(5):1595–606CrossRefPubMed Krause M, Museyko O, Breer S, Wulff B, Duckstein C, Vettorazzi E et al (2014) Accuracy of trabecular structure by HR-pQCT compared to gold standard muCT in the radius and tibia of patients with osteoporosis and long-term bisphosphonate therapy. Osteoporos Int 25(5):1595–606CrossRefPubMed
15.
go back to reference Peters M, de Jong J, Scharmga A, van Tubergen A, Loeffen D, Weijers R et al (2016) The reproducibility of a semi-automatic algorithm in the detection of cortical breaks and adjacent trabecular bone loss in scan-rescan data from patients with early arthritis. Arthr Rheum 68(suppl 10) Peters M, de Jong J, Scharmga A, van Tubergen A, Loeffen D, Weijers R et al (2016) The reproducibility of a semi-automatic algorithm in the detection of cortical breaks and adjacent trabecular bone loss in scan-rescan data from patients with early arthritis. Arthr Rheum 68(suppl 10)
16.
go back to reference Burghardt AJ, Buie HR, Laib A, Majumdar S, Boyd SK (2010) Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCT. Bone 47(3):519–528CrossRefPubMedPubMedCentral Burghardt AJ, Buie HR, Laib A, Majumdar S, Boyd SK (2010) Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCT. Bone 47(3):519–528CrossRefPubMedPubMedCentral
17.
go back to reference Buie HR, Campbell GM, Klinck RJ, MacNeil JA, Boyd SK (2007) Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis. Bone 41(4):505–515CrossRefPubMed Buie HR, Campbell GM, Klinck RJ, MacNeil JA, Boyd SK (2007) Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis. Bone 41(4):505–515CrossRefPubMed
18.
go back to reference Laib A, Hauselmann HJ, Ruegsegger P (1998) In vivo high resolution 3D-QCT of the human forearm. Technol Health Care 6(5–6):329–337PubMed Laib A, Hauselmann HJ, Ruegsegger P (1998) In vivo high resolution 3D-QCT of the human forearm. Technol Health Care 6(5–6):329–337PubMed
19.
go back to reference Tjong W, Kazakia GJ, Burghardt AJ, Majumdar S (2012) The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure. Med Phys 39(4):1893–903CrossRefPubMedPubMedCentral Tjong W, Kazakia GJ, Burghardt AJ, Majumdar S (2012) The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure. Med Phys 39(4):1893–903CrossRefPubMedPubMedCentral
20.
go back to reference Tjong W, Nirody J, Burghardt AJ, Carballido-Gamio J, Kazakia GJ (2014) Structural analysis of cortical porosity applied to HR-pQCT data. Med Phys 41(1):013701CrossRefPubMed Tjong W, Nirody J, Burghardt AJ, Carballido-Gamio J, Kazakia GJ (2014) Structural analysis of cortical porosity applied to HR-pQCT data. Med Phys 41(1):013701CrossRefPubMed
21.
go back to reference Zebaze RM, Ghasem-Zadeh A, Bohte A, Iuliano-Burns S, Mirams M, Price RI et al (2010) Intracortical remodelling and porosity in the distal radius and post-mortem femurs of women: a cross-sectional study. Lancet 375(9727):1729–1736CrossRefPubMed Zebaze RM, Ghasem-Zadeh A, Bohte A, Iuliano-Burns S, Mirams M, Price RI et al (2010) Intracortical remodelling and porosity in the distal radius and post-mortem femurs of women: a cross-sectional study. Lancet 375(9727):1729–1736CrossRefPubMed
22.
go back to reference Finzel S, Rech J, Schmidt S, Engelke K, Englbrecht M, Schett G (2013) Interleukin-6 receptor blockade induces limited repair of bone erosions in rheumatoid arthritis: a micro CT study. Ann Rheum Dis 72(3):396–400CrossRefPubMed Finzel S, Rech J, Schmidt S, Engelke K, Englbrecht M, Schett G (2013) Interleukin-6 receptor blockade induces limited repair of bone erosions in rheumatoid arthritis: a micro CT study. Ann Rheum Dis 72(3):396–400CrossRefPubMed
23.
go back to reference Finzel S, Rech J, Schmidt S, Engelke K, Englbrecht M, Stach C et al (2011) Repair of bone erosions in rheumatoid arthritis treated with tumour necrosis factor inhibitors is based on bone apposition at the base of the erosion. Ann Rheum Dis 70(9):1587–1593CrossRefPubMed Finzel S, Rech J, Schmidt S, Engelke K, Englbrecht M, Stach C et al (2011) Repair of bone erosions in rheumatoid arthritis treated with tumour necrosis factor inhibitors is based on bone apposition at the base of the erosion. Ann Rheum Dis 70(9):1587–1593CrossRefPubMed
Metadata
Title
The Reliability of a Semi-automated Algorithm for Detection of Cortical Interruptions in Finger Joints on High Resolution CT Compared to MicroCT
Authors
M. Peters
A. Scharmga
A. van Tubergen
J. Arts
D. Loeffen
R. Weijers
B. van Rietbergen
P. Geusens
J. P. van den Bergh
Publication date
01-08-2017
Publisher
Springer US
Published in
Calcified Tissue International / Issue 2/2017
Print ISSN: 0171-967X
Electronic ISSN: 1432-0827
DOI
https://doi.org/10.1007/s00223-017-0264-5

Other articles of this Issue 2/2017

Calcified Tissue International 2/2017 Go to the issue