Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 5/2019

01-05-2019 | Knee

No correlation between rotation of femoral components in the transverse plane and clinical outcome after total knee arthroplasty

Authors: Roland Becker, Katharina Bäker, Hagen Hommel, Manfred Bernard, Sebastian Kopf

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 5/2019

Login to get access

Abstract

Purpose

It was hypothesized that malrotation of femoral component in total knee arthroplasty (TKA) will significantly impact clinical outcome.

Methods

Eighty-eight consecutive patients with primary osteoarthritis of the knee were prospectively evaluated. They received a cemented posterior stabilized TKA (NexGen, Zimmer/Biomet® Inc., Warsaw, IN, USA). The femoral component was placed in 3° of external rotation referenced to the posterior condylar line. Postoperatively, a CT scan was performed to evaluate rotation of femoral component in the transverse plane. SF-36, KSS, and WOMAC, as well as their range of motion was assessed prior to surgery, after 6 and 24 months. Data are presented as mean and standard deviation (SD), as well as range if applicable. Correlation analysis was performed between the placement of the femoral component in the transverse plane and the clinical outcome.

Results

Femoral component placement was on average 0.1° [SD 2.5°, range − 6.5° to + 6.5°] referenced to the surgical transepicondylar line showing a wide range between the two landmarks after surgery. After 6 months, WOMAC category ‘physical function’ correlated significantly with femoral component rotation (r = − 0.28, p = 0.007). After 24 months, WOMAC categories ‘physical function’ and ‘pain’ correlated significantly with femoral rotation (r = − 0.41, p < 0.001; and r = − 0.33, p = 0.001). No significant correlations were found between femoral component rotation and range of motion (r = 0.04), WOMAC category “stiffness”, KSS, as well as SF-36 questionnaires. These reported formally significant correlations were without any clinical relevance.

Discussion

The study showed that there is a significant patients specific femoral component placement in the transverse plane. Internal or external malrotation of the femoral component does not correlate automatically with poor knee function. The lack of correlation between femoral component position and clinical as well as functional outcome underlines complexity and significant individuality of each patient. The surgeon should be aware of the finding and attention should be paid during surgery when significant divergency is seen between the two landmarks. Soft tissue balancing might be very crucial in these specific patients, which needs to be studied in depth in the future.

Level of evidence

II.
Literature
1.
go back to reference Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, Nakamura T (1999) Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 366:155–163CrossRef Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, Nakamura T (1999) Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res 366:155–163CrossRef
2.
go back to reference Akagi M, Oh M, Nonaka T, Tsujimoto H, Asano T, Hamanishi C (2004) An anteroposterior axis of the tibia for total knee arthroplasty. Clin Orthop Relat Res 420:213–219CrossRef Akagi M, Oh M, Nonaka T, Tsujimoto H, Asano T, Hamanishi C (2004) An anteroposterior axis of the tibia for total knee arthroplasty. Clin Orthop Relat Res 420:213–219CrossRef
3.
go back to reference Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed
4.
go back to reference Bell SW, Young P, Drury C, Smith J, Anthony I, Jones B, Blyth M, McLean A (2014) Component rotational alignment in unexplained painful primary total knee arthroplasty. Knee 21:272–277CrossRefPubMed Bell SW, Young P, Drury C, Smith J, Anthony I, Jones B, Blyth M, McLean A (2014) Component rotational alignment in unexplained painful primary total knee arthroplasty. Knee 21:272–277CrossRefPubMed
5.
go back to reference Bhattee G, Moonot P, Govindaswamy R, Pope A, Fiddian N, Harvey A (2014) Does malrotation of components correlate with patient dissatisfaction following secondary patellar resurfacing? Knee 21:247–251CrossRefPubMed Bhattee G, Moonot P, Govindaswamy R, Pope A, Fiddian N, Harvey A (2014) Does malrotation of components correlate with patient dissatisfaction following secondary patellar resurfacing? Knee 21:247–251CrossRefPubMed
6.
go back to reference Boldt JG, Stiehl JB, Hodler J, Zanetti M, Munzinger U (2006) Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty. Int Orthop 30:420–425CrossRefPubMedPubMedCentral Boldt JG, Stiehl JB, Hodler J, Zanetti M, Munzinger U (2006) Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty. Int Orthop 30:420–425CrossRefPubMedPubMedCentral
7.
go back to reference Castelli CC, Falvo DA, Iapicca ML, Gotti V (2016) Rotational alignment of the femoral component in total knee arthroplasty. Ann Transl Med 4:4PubMedPubMedCentral Castelli CC, Falvo DA, Iapicca ML, Gotti V (2016) Rotational alignment of the femoral component in total knee arthroplasty. Ann Transl Med 4:4PubMedPubMedCentral
8.
go back to reference Chen Z, Wang L, Liu Y, He J, Lian Q, Li D, Jin Z (2015) Effect of component mal-rotation on knee loading in total knee arthroplasty using multi-body dynamics modeling under a simulated walking gait. J Orthop Res 33:1287–1296CrossRefPubMed Chen Z, Wang L, Liu Y, He J, Lian Q, Li D, Jin Z (2015) Effect of component mal-rotation on knee loading in total knee arthroplasty using multi-body dynamics modeling under a simulated walking gait. J Orthop Res 33:1287–1296CrossRefPubMed
9.
go back to reference Dalury DF, Pomeroy DL, Gorab RS, Adams MJ (2013) Why are total knee arthroplasties being revised? J Arthroplast 28:120–121CrossRef Dalury DF, Pomeroy DL, Gorab RS, Adams MJ (2013) Why are total knee arthroplasties being revised? J Arthroplast 28:120–121CrossRef
10.
go back to reference Davidson D, Yen YM, Jette AM, Olarsch S, Kim YJ (2011) Responsiveness of the SF-36 and WOMAC following periacetabular osteotomy for acetabular dysplasia. J Bone Joint Surg Am 93:2214–2218CrossRefPubMed Davidson D, Yen YM, Jette AM, Olarsch S, Kim YJ (2011) Responsiveness of the SF-36 and WOMAC following periacetabular osteotomy for acetabular dysplasia. J Bone Joint Surg Am 93:2214–2218CrossRefPubMed
11.
go back to reference Dye SF, Vaupel GL, Dye CC (1998) Conscious neurosensory mapping of the internal structures of the human knee without intraarticular anesthesia. Am J Sports Med 26:773–777CrossRefPubMed Dye SF, Vaupel GL, Dye CC (1998) Conscious neurosensory mapping of the internal structures of the human knee without intraarticular anesthesia. Am J Sports Med 26:773–777CrossRefPubMed
12.
go back to reference Eckhoff D, Hogan C, DiMatteo L, Robinson M, Bach J (2007) Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res 461:238–244PubMed Eckhoff D, Hogan C, DiMatteo L, Robinson M, Bach J (2007) Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res 461:238–244PubMed
13.
go back to reference Feczko PZ, Fokkenrood HJP, van Assen T, Deckers P, Emans PJ, Arts JJ (2017) Accuracy of the precision saw versus the sagittal saw during total knee arthroplasty: a randomised clinical trial. Knee 24:1213–1220CrossRefPubMed Feczko PZ, Fokkenrood HJP, van Assen T, Deckers P, Emans PJ, Arts JJ (2017) Accuracy of the precision saw versus the sagittal saw during total knee arthroplasty: a randomised clinical trial. Knee 24:1213–1220CrossRefPubMed
14.
go back to reference Fehring TK (2000) Rotational malalignment of the femoral component in total knee arthroplasty. Clin Orthop Relat Res 380:72–79CrossRef Fehring TK (2000) Rotational malalignment of the femoral component in total knee arthroplasty. Clin Orthop Relat Res 380:72–79CrossRef
15.
go back to reference Franceschini V, Nodzo SR, Gonzalez Della Valle A (2016) Femoral component rotation in total knee arthroplasty: a comparison between transepicondylar axis and posterior condylar line referencing. J Arthroplast 31:2917–2921CrossRef Franceschini V, Nodzo SR, Gonzalez Della Valle A (2016) Femoral component rotation in total knee arthroplasty: a comparison between transepicondylar axis and posterior condylar line referencing. J Arthroplast 31:2917–2921CrossRef
16.
go back to reference Ghosh KM, Merican AM, Iranpour F, Deehan DJ, Amis AA (2010) The effect of femoral component rotation on the extensor retinaculum of the knee. J Orthop Res 28:1136–1141CrossRefPubMed Ghosh KM, Merican AM, Iranpour F, Deehan DJ, Amis AA (2010) The effect of femoral component rotation on the extensor retinaculum of the knee. J Orthop Res 28:1136–1141CrossRefPubMed
17.
go back to reference Heesterbeek PJ, Jacobs WC, Wymenga AB (2009) Effects of the balanced gap technique on femoral component rotation in TKA. Clin Orthop Relat Res 467:1015–1022CrossRefPubMed Heesterbeek PJ, Jacobs WC, Wymenga AB (2009) Effects of the balanced gap technique on femoral component rotation in TKA. Clin Orthop Relat Res 467:1015–1022CrossRefPubMed
18.
go back to reference Hernandez-Vaquero D, Noriega-Fernandez A, Fernandez-Carreira JM, Fernandez-Simon JM, De Los Rios JL (2014) Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:3127–3134CrossRefPubMed Hernandez-Vaquero D, Noriega-Fernandez A, Fernandez-Carreira JM, Fernandez-Simon JM, De Los Rios JL (2014) Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:3127–3134CrossRefPubMed
19.
go back to reference Hohmann E, Tetsworth K (2016) Do manual cutting guides for total knee arthroplasty introduce systematic error? Int Orthop 40:277–2784CrossRefPubMed Hohmann E, Tetsworth K (2016) Do manual cutting guides for total knee arthroplasty introduce systematic error? Int Orthop 40:277–2784CrossRefPubMed
20.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop 248:13–14 Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop 248:13–14
21.
go back to reference Kessler O, Patil S, Colwell CW, D’Lima DD (2008) The effect of femoral component malrotation on patellar biomechanics. J Biomech 41:3332–3339CrossRefPubMed Kessler O, Patil S, Colwell CW, D’Lima DD (2008) The effect of femoral component malrotation on patellar biomechanics. J Biomech 41:3332–3339CrossRefPubMed
22.
go back to reference Lee JK, Lee S, Chun SH, Kim KT, Lee MC (2017) Rotational alignment of femoral component with different methods in total knee arthroplasty: a randomized, controlled trial. BMC Musculoskelet Disord 18:217CrossRefPubMedPubMedCentral Lee JK, Lee S, Chun SH, Kim KT, Lee MC (2017) Rotational alignment of femoral component with different methods in total knee arthroplasty: a randomized, controlled trial. BMC Musculoskelet Disord 18:217CrossRefPubMedPubMedCentral
23.
go back to reference Lustig S, Lavoie F, Selmi TA, Servien E, Neyret P (2008) Relationship between the surgical epicondylar axis and the articular surface of the distal femur: an anatomic study. Knee Surg Sports Traumatol Arthrosc 16:674–682CrossRefPubMed Lustig S, Lavoie F, Selmi TA, Servien E, Neyret P (2008) Relationship between the surgical epicondylar axis and the articular surface of the distal femur: an anatomic study. Knee Surg Sports Traumatol Arthrosc 16:674–682CrossRefPubMed
24.
go back to reference Merican AM, Ghosh KM, Iranpour F, Deehan DJ, Amis AA (2011) The effect of femoral component rotation on the kinematics of the tibiofemoral and patellofemoral joints after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:1479–1487CrossRefPubMed Merican AM, Ghosh KM, Iranpour F, Deehan DJ, Amis AA (2011) The effect of femoral component rotation on the kinematics of the tibiofemoral and patellofemoral joints after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:1479–1487CrossRefPubMed
25.
go back to reference Meric G, Gracitelli GC, Aram LJ, Swank ML, Bugbee WD (2015) Variability in distal femoral anatomy in patients undergoing total knee arthroplasty: measurements on 13,546 computed tomography scans. J Arthroplast 30:1835–1838CrossRef Meric G, Gracitelli GC, Aram LJ, Swank ML, Bugbee WD (2015) Variability in distal femoral anatomy in patients undergoing total knee arthroplasty: measurements on 13,546 computed tomography scans. J Arthroplast 30:1835–1838CrossRef
26.
go back to reference Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99–107CrossRefPubMed Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99–107CrossRefPubMed
27.
go back to reference Nicoll D, Rowley DI (2010) Internal rotational error of the tibial component is a major cause of pain after total knee replacement. J Bone Joint Surg Br 92:1238–1244CrossRefPubMed Nicoll D, Rowley DI (2010) Internal rotational error of the tibial component is a major cause of pain after total knee replacement. J Bone Joint Surg Br 92:1238–1244CrossRefPubMed
28.
go back to reference Okamoto S, Mizu-uchi H, Okazaki K, Hamai S, Tashiro Y, Nakahara H, Iwamoto Y (2016) Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24:229–235CrossRefPubMed Okamoto S, Mizu-uchi H, Okazaki K, Hamai S, Tashiro Y, Nakahara H, Iwamoto Y (2016) Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24:229–235CrossRefPubMed
29.
go back to reference Pfitzner T, Abdel MP, von Roth P, Perka C, Hommel H (2014) Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial. Clin Orthop Relat Res 472:2913–2922CrossRefPubMedPubMedCentral Pfitzner T, Abdel MP, von Roth P, Perka C, Hommel H (2014) Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial. Clin Orthop Relat Res 472:2913–2922CrossRefPubMedPubMedCentral
30.
go back to reference Pietsch M, Hofmann S (2012) Early revision for isolated internal malrotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:1057–1063CrossRefPubMed Pietsch M, Hofmann S (2012) Early revision for isolated internal malrotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:1057–1063CrossRefPubMed
31.
go back to reference Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. JArthroplast 17:698–705CrossRef Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. JArthroplast 17:698–705CrossRef
32.
go back to reference Rienmüller A, Guggi T, Gruber G, Preiss S, Drobny T (2012) The effect of femoral component rotation on the five-year outcome of cemented mobile bearing total knee arthroplasty. Int Orthop 36:2067–2072CrossRefPubMedPubMedCentral Rienmüller A, Guggi T, Gruber G, Preiss S, Drobny T (2012) The effect of femoral component rotation on the five-year outcome of cemented mobile bearing total knee arthroplasty. Int Orthop 36:2067–2072CrossRefPubMedPubMedCentral
33.
go back to reference Sanchis-Alfonso V, Roselló-Sastre E (2003) Hypothesis: anterior knee pain in the young patient-what causes the pain?” Neural model”. Acta Orthop Scand 74:697–703CrossRefPubMed Sanchis-Alfonso V, Roselló-Sastre E (2003) Hypothesis: anterior knee pain in the young patient-what causes the pain?” Neural model”. Acta Orthop Scand 74:697–703CrossRefPubMed
35.
go back to reference Silva A, Pinto E, Sampaio R (2016) Rotational alignment in patient-specific instrumentation in TKA: MRI or CT? Knee Surg Sports Traumatol Arthrosc 24:3648–3652CrossRefPubMed Silva A, Pinto E, Sampaio R (2016) Rotational alignment in patient-specific instrumentation in TKA: MRI or CT? Knee Surg Sports Traumatol Arthrosc 24:3648–3652CrossRefPubMed
36.
go back to reference Siston RA, Cromie MJ, Gold GE, Goodman SB, Delp SL, Maloney WJ, Giori NJ (2008) Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty. J Bone Joint Surg Am 90:2098–20104CrossRefPubMed Siston RA, Cromie MJ, Gold GE, Goodman SB, Delp SL, Maloney WJ, Giori NJ (2008) Averaging different alignment axes improves femoral rotational alignment in computer-navigated total knee arthroplasty. J Bone Joint Surg Am 90:2098–20104CrossRefPubMed
37.
go back to reference Stoeckl B, Nogler M, Krismer M, Beimel C, de la Barrera JL, Kessler O (2006) Reliability of the transepicondylar axis as an anatomical landmark in total knee arthroplasty. J Arthroplast 21:878–882CrossRef Stoeckl B, Nogler M, Krismer M, Beimel C, de la Barrera JL, Kessler O (2006) Reliability of the transepicondylar axis as an anatomical landmark in total knee arthroplasty. J Arthroplast 21:878–882CrossRef
38.
go back to reference Terashima T, Onodera T, Sawaguchi N, Kasahara Y, Majima T (2015) External rotation of the femoral component decreases patellofemoral contact stress in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23:3266–3272CrossRefPubMed Terashima T, Onodera T, Sawaguchi N, Kasahara Y, Majima T (2015) External rotation of the femoral component decreases patellofemoral contact stress in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23:3266–3272CrossRefPubMed
39.
go back to reference Thienpont E, Schwab PE, Paternostre F, Koch P (2014) Rotational alignment of the distal femur: anthropometric measurements with CT-based patient-specific instruments planning show high variability of the posterior condylar angle. Knee Surg Sports Traumatol Arthrosc 22:2995–3002CrossRefPubMed Thienpont E, Schwab PE, Paternostre F, Koch P (2014) Rotational alignment of the distal femur: anthropometric measurements with CT-based patient-specific instruments planning show high variability of the posterior condylar angle. Knee Surg Sports Traumatol Arthrosc 22:2995–3002CrossRefPubMed
40.
go back to reference Vanbiervliet J, Bellemans J, Verlinden C, Luyckx JP, Labey L, Innocenti B, Vandenneucker H (2011) The influence of malrotation and femoral component material on patellofemoral wear during gait. J Bone Joint Surg Br 93:1348–1354CrossRefPubMed Vanbiervliet J, Bellemans J, Verlinden C, Luyckx JP, Labey L, Innocenti B, Vandenneucker H (2011) The influence of malrotation and femoral component material on patellofemoral wear during gait. J Bone Joint Surg Br 93:1348–1354CrossRefPubMed
41.
go back to reference Verlinden C, Uvin P, Labey L, Luyckx JP, Bellemans J, Vandenneucker H (2010) The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait: an in vitro biomechanical study. J Bone Joint Surg Br 92:737–742CrossRefPubMed Verlinden C, Uvin P, Labey L, Luyckx JP, Bellemans J, Vandenneucker H (2010) The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait: an in vitro biomechanical study. J Bone Joint Surg Br 92:737–742CrossRefPubMed
42.
go back to reference Victor J, Van Doninck D, Labey L, Van Glabbeek F, Parizel P, Bellemans J (2009) A common reference frame for describing rotation of the distal femur: a CT-based kinematic study using cadavers. J Bone Joint Surg Br 91:683–690CrossRefPubMed Victor J, Van Doninck D, Labey L, Van Glabbeek F, Parizel P, Bellemans J (2009) A common reference frame for describing rotation of the distal femur: a CT-based kinematic study using cadavers. J Bone Joint Surg Br 91:683–690CrossRefPubMed
43.
go back to reference Walde TA, Bussert J, Sehmisch S, Balcarek P, Stürmer KM, Walde HJ, Frosch KH (2010) Optimized functional femoral rotation in navigated total knee arthroplasty considering ligament tension. Knee 17:381–386CrossRefPubMed Walde TA, Bussert J, Sehmisch S, Balcarek P, Stürmer KM, Walde HJ, Frosch KH (2010) Optimized functional femoral rotation in navigated total knee arthroplasty considering ligament tension. Knee 17:381–386CrossRefPubMed
44.
go back to reference Ware JE, Gandek B (1998) Overview of the SF-36 Health Survey and the International Quality of Life Assessment (IQOLA) Project. J Clin Epidemiol 51:903–912CrossRefPubMed Ware JE, Gandek B (1998) Overview of the SF-36 Health Survey and the International Quality of Life Assessment (IQOLA) Project. J Clin Epidemiol 51:903–912CrossRefPubMed
45.
go back to reference Witonski D, Wagrowska-Danielewicz M (1999) Distribution of substance-P nerve fibers in the knee joint in patients with anterior knee pain syndrome. Knee Surg Sports Traumatol Arthrosc 7:177–183CrossRefPubMed Witonski D, Wagrowska-Danielewicz M (1999) Distribution of substance-P nerve fibers in the knee joint in patients with anterior knee pain syndrome. Knee Surg Sports Traumatol Arthrosc 7:177–183CrossRefPubMed
Metadata
Title
No correlation between rotation of femoral components in the transverse plane and clinical outcome after total knee arthroplasty
Authors
Roland Becker
Katharina Bäker
Hagen Hommel
Manfred Bernard
Sebastian Kopf
Publication date
01-05-2019
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 5/2019
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-018-4981-8

Other articles of this Issue 5/2019

Knee Surgery, Sports Traumatology, Arthroscopy 5/2019 Go to the issue