Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 11/2017

01-11-2017 | Knee

Association between anteroposterior laxity in mid-range flexion and subjective healing of instability after total knee arthroplasty

Authors: Tomoharu Mochizuki, Osamu Tanifuji, Takashi Sato, Hiroki Hijikata, Hiroshi Koga, Satoshi Watanabe, Yukimasa Higano, Akihiro Ariumi, Takayuki Murayama, Hiroshi Yamagiwa, Naoto Endo

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 11/2017

Login to get access

Abstract

Purpose

Flexion instability following total knee arthroplasty (TKA) is a common indication of early revision. The association between the objective anteroposterior (AP) laxity direction in mid-range flexion and the subjective healing of instability remains unclear; thus, this study aimed to clarify this association.

Methods

In this study, 110 knees (74 females, 92 knees; 16 males, 18 knees) with medial pivot implants were examined with a median age of 79 (range 60–92) years for a median follow-up duration of 22 (range 6–125) months. AP laxity was measured using a KT-1000 arthrometer. Self-reported knee instability score was used for the subjective healing of instability.

Results

Eighty-seven knees did not feel unstable (Group 0), whereas 23 knees felt unstable (Group 1). There was a significant difference in AP displacement [Group 0: median 6 mm; range 2–15 mm and Group 1: median 8 mm; range 4–14; p < 0.0001]. The threshold value of 7 mm was determined using the area under receiver operating characteristic curve of 0.79 [95% confidence interval (CI) 0.69–0.88, p < 0.0001]. In multivariate analysis, AP displacement of ≥7 mm was an independent risk factor for feelings of instability (odds ratio 7.695; 95% CI 2.306–25.674; p = 0.001).

Conclusions

AP laxity of ≥7 mm represents a known cause of feelings of instability. By controlling AP laxity in TKAs, without stiffness in the knee, it is possible to prevent feelings of instability. The clinical relevance is that AP laxity of <7 mm is one of the target areas in TKA.

Level of evidence

IV.
Literature
1.
go back to reference Ariumi A, Sato T, Kobayashi K, Koga Y, Omori G, Minato I, Endo N (2010) Three-dimensional lower extremity alignment in the weight-bearing standing position in healthy elderly subjects. J Orthop Sci 15:64–70CrossRefPubMed Ariumi A, Sato T, Kobayashi K, Koga Y, Omori G, Minato I, Endo N (2010) Three-dimensional lower extremity alignment in the weight-bearing standing position in healthy elderly subjects. J Orthop Sci 15:64–70CrossRefPubMed
2.
go back to reference Bellemans J, Robijns F, Duerinckx J, Banks S, Vandenneucker H (2005) The influence of tibial slope of maximal flexion after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 13:193–196CrossRefPubMed Bellemans J, Robijns F, Duerinckx J, Banks S, Vandenneucker H (2005) The influence of tibial slope of maximal flexion after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 13:193–196CrossRefPubMed
3.
go back to reference Blaha JD (2004) The rationale for a total knee implant that confers anteroposterior stability throughout range of motion. J Arthroplasty 19:22–26CrossRefPubMed Blaha JD (2004) The rationale for a total knee implant that confers anteroposterior stability throughout range of motion. J Arthroplasty 19:22–26CrossRefPubMed
4.
5.
go back to reference Colizza WA, Insall JN, Scuderi GR (1995) The posterior-stabilized knee prosthesis: assessment of polyethylene damage and osteolysis after a ten-year minimum follow-up. J Bone Joint Surg Am 77:1713–1720CrossRefPubMed Colizza WA, Insall JN, Scuderi GR (1995) The posterior-stabilized knee prosthesis: assessment of polyethylene damage and osteolysis after a ten-year minimum follow-up. J Bone Joint Surg Am 77:1713–1720CrossRefPubMed
6.
go back to reference Dennis D, Komistek R, Mahfouz M (2003) In vivo fluoroscopic analysis of fixed-bearing total knee replacements. Clin Orthop Relat Res 410:114–130CrossRef Dennis D, Komistek R, Mahfouz M (2003) In vivo fluoroscopic analysis of fixed-bearing total knee replacements. Clin Orthop Relat Res 410:114–130CrossRef
7.
go back to reference Dejour D, Deschamps G, Garotta L, Dejour H (1999) Laxity in posterior cruciate sparing and posterior stabilized total knee prostheses. Clin Orthop Relat Res 364:182–193CrossRef Dejour D, Deschamps G, Garotta L, Dejour H (1999) Laxity in posterior cruciate sparing and posterior stabilized total knee prostheses. Clin Orthop Relat Res 364:182–193CrossRef
8.
go back to reference Emmerson KP, Moran CG, Pinder IM (1996) Survivorship analysis of the kinematic stabilizer total knee replacement: a 10–14 year follow-up. J Bone Joint Surg Br 78:441–445PubMed Emmerson KP, Moran CG, Pinder IM (1996) Survivorship analysis of the kinematic stabilizer total knee replacement: a 10–14 year follow-up. J Bone Joint Surg Br 78:441–445PubMed
9.
go back to reference Fehring TK, Valadie AL (1994) Knee instability after total knee arthroplasty. Clin Orthop Relat Res 299:157–162 Fehring TK, Valadie AL (1994) Knee instability after total knee arthroplasty. Clin Orthop Relat Res 299:157–162
10.
go back to reference Felson DT, Niu J, McClennan C, Sack B, Aliabadi P, Hunter DJ, Guermazi A, Englund M (2007) Knee buckling: prevalence, risk factors, and associated limitations in function. Ann Intern Med 147:534–540CrossRefPubMed Felson DT, Niu J, McClennan C, Sack B, Aliabadi P, Hunter DJ, Guermazi A, Englund M (2007) Knee buckling: prevalence, risk factors, and associated limitations in function. Ann Intern Med 147:534–540CrossRefPubMed
11.
go back to reference Fort-Rodriquez DE, Scuderi GR, Insall JN (1997) Survivorship of cemented total knee arthroplasty. Clin Orthop Relat Res 345:79–86 Fort-Rodriquez DE, Scuderi GR, Insall JN (1997) Survivorship of cemented total knee arthroplasty. Clin Orthop Relat Res 345:79–86
12.
go back to reference Irrgang JJ, Snyder-Mackler L, Wainner RS, Fu FH, Harner CD (1998) Development of a patient-reported measure of function of the knee. J Bone Joint Surg Am 80:1132–1145CrossRefPubMed Irrgang JJ, Snyder-Mackler L, Wainner RS, Fu FH, Harner CD (1998) Development of a patient-reported measure of function of the knee. J Bone Joint Surg Am 80:1132–1145CrossRefPubMed
13.
go back to reference Ishii Y, Matsuda Y, Ishii R, Sakata S, Omori G (2004) Sagittal laxity in vivo after total knee replacement. Arch Orthop Trauma Surg 125:249–253CrossRefPubMed Ishii Y, Matsuda Y, Ishii R, Sakata S, Omori G (2004) Sagittal laxity in vivo after total knee replacement. Arch Orthop Trauma Surg 125:249–253CrossRefPubMed
14.
go back to reference Knoop J, van der Leeden M, van der Esch M, Thorstensson CA, Gerritsen M, Voorneman RE, Lems WF, Roorda LD, Dekker J, Steultjens MP (2012) Association of lower muscle strength with self-reported knee instability in osteoarthritis of the knee: results from the Amsterdam Osteoarthritis cohort. Arthritis Care Res (Hoboken) 64:38–45CrossRef Knoop J, van der Leeden M, van der Esch M, Thorstensson CA, Gerritsen M, Voorneman RE, Lems WF, Roorda LD, Dekker J, Steultjens MP (2012) Association of lower muscle strength with self-reported knee instability in osteoarthritis of the knee: results from the Amsterdam Osteoarthritis cohort. Arthritis Care Res (Hoboken) 64:38–45CrossRef
15.
go back to reference Kobayashi K, Sakamoto M, Tanabe Y, Ariumi A, Sato T, Omori G, Omori G, Koga Y (2009) Automated image registration for assessing three-dimensional alignment of entire lower extremity and implant position using bi-plane radiography. J Biomech 42:2818–2822CrossRefPubMed Kobayashi K, Sakamoto M, Tanabe Y, Ariumi A, Sato T, Omori G, Omori G, Koga Y (2009) Automated image registration for assessing three-dimensional alignment of entire lower extremity and implant position using bi-plane radiography. J Biomech 42:2818–2822CrossRefPubMed
16.
go back to reference Kuster MS, Bitschanau B, Votruba T (2004) Influence of collateral ligament laxity on patient satisfaction after total knee arthroplasty: a comparative bilateral study. Arch Orthop Trauma Surg 124:415–417CrossRefPubMed Kuster MS, Bitschanau B, Votruba T (2004) Influence of collateral ligament laxity on patient satisfaction after total knee arthroplasty: a comparative bilateral study. Arch Orthop Trauma Surg 124:415–417CrossRefPubMed
17.
go back to reference Martin JW, Whiteside LA (1990) The influence of joint line position on knee stability after condylar knee arthroplasty. Clin Orthop Relat Res 259:146–156 Martin JW, Whiteside LA (1990) The influence of joint line position on knee stability after condylar knee arthroplasty. Clin Orthop Relat Res 259:146–156
18.
go back to reference Matsuda S, Miura H, Nagamine R, Urabe K, Matsunobu T, Iwamoto Y (1999) Knee stability in posterior cruciate ligament retaining total knee arthroplasty. Clin Orthop Relat Res 366:169–173CrossRef Matsuda S, Miura H, Nagamine R, Urabe K, Matsunobu T, Iwamoto Y (1999) Knee stability in posterior cruciate ligament retaining total knee arthroplasty. Clin Orthop Relat Res 366:169–173CrossRef
19.
go back to reference Mochizuki T, Sato T, Tanifuji O, Kobayashi K, Koga Y, Yamagiwa H, Omori G, Endo N (2013) In vivo pre- and postoperative three-dimensional knee kinematics in unicompartmental knee arthroplasty. J Orthop Sci 18:54–60CrossRefPubMed Mochizuki T, Sato T, Tanifuji O, Kobayashi K, Koga Y, Yamagiwa H, Omori G, Endo N (2013) In vivo pre- and postoperative three-dimensional knee kinematics in unicompartmental knee arthroplasty. J Orthop Sci 18:54–60CrossRefPubMed
20.
go back to reference Mochizuki T, Sato T, Blaha JD, Tanifuji O, Kobayashi K, Yamagiwa H, Watanabe S, Matsueda M, Koga Y, Omori G, Endo N (2014) Kinematics of the knee after unicompartmental arthroplasty is not the same as normal and is similar to the kinematics of the knee with osteoarthritis. Knee Surg Sports Traumatol Arthrosc 22:1911–1917CrossRefPubMed Mochizuki T, Sato T, Blaha JD, Tanifuji O, Kobayashi K, Yamagiwa H, Watanabe S, Matsueda M, Koga Y, Omori G, Endo N (2014) Kinematics of the knee after unicompartmental arthroplasty is not the same as normal and is similar to the kinematics of the knee with osteoarthritis. Knee Surg Sports Traumatol Arthrosc 22:1911–1917CrossRefPubMed
21.
go back to reference Mochizuki T, Sato T, Blaha JD, Tanifuji O, Kobayashi K, Yamagiwa H, Watanabe S, Koga Y, Omori G, Endo N (2014) The clinical epicondylar axis is not the functional flexion axis of the human knee. J Orthop Sci 19:451–456CrossRefPubMed Mochizuki T, Sato T, Blaha JD, Tanifuji O, Kobayashi K, Yamagiwa H, Watanabe S, Koga Y, Omori G, Endo N (2014) The clinical epicondylar axis is not the functional flexion axis of the human knee. J Orthop Sci 19:451–456CrossRefPubMed
22.
go back to reference Mochizuki T, Sato T, Tanifuji O, Kobayashi K, Yamagiwa H, Watanabe S, Koga Y, Omori G, Endo N (2015) Unicompartmental knee arthroplasty cannot restore the functional flexion axis of a living knee to normal. Knee Surg Sports Traumatol Arthrosc 23:3736–3742CrossRefPubMed Mochizuki T, Sato T, Tanifuji O, Kobayashi K, Yamagiwa H, Watanabe S, Koga Y, Omori G, Endo N (2015) Unicompartmental knee arthroplasty cannot restore the functional flexion axis of a living knee to normal. Knee Surg Sports Traumatol Arthrosc 23:3736–3742CrossRefPubMed
23.
go back to reference Mochizuki T, Tanifuji O, Koga Y, Sato T, Kobayashi K, Nishino K, Watanabe S, Ariumi A, Fujii T, Yamagiwa H, Omori G, Endo N (2016) Sex differences in femoral deformity determined using three-dimensional assessment for osteoarthritic knees. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-016-4166-2 Mochizuki T, Tanifuji O, Koga Y, Sato T, Kobayashi K, Nishino K, Watanabe S, Ariumi A, Fujii T, Yamagiwa H, Omori G, Endo N (2016) Sex differences in femoral deformity determined using three-dimensional assessment for osteoarthritic knees. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-016-4166-2
24.
go back to reference Mueller JK, Wentorf FA, Moore RE (2014) Femoral and tibial insert downsizing increases the laxity envelope in TKA. Knee Surg Sports Traumatol Arthrosc 22:3003–3011CrossRefPubMedPubMedCentral Mueller JK, Wentorf FA, Moore RE (2014) Femoral and tibial insert downsizing increases the laxity envelope in TKA. Knee Surg Sports Traumatol Arthrosc 22:3003–3011CrossRefPubMedPubMedCentral
25.
go back to reference Murayama T, Sato T, Watanabe S, Kobayashi K, Tanifuji O, Mochizuki T, Yamagiwa H, Koga Y, Omori G, Endo N (2016) Three-dimensional in vivo dynamic motion analysis of anterior cruciate ligament-deficient knees during squatting using geometric center axis of the femur. J Orthop Sci 21:159–165CrossRefPubMed Murayama T, Sato T, Watanabe S, Kobayashi K, Tanifuji O, Mochizuki T, Yamagiwa H, Koga Y, Omori G, Endo N (2016) Three-dimensional in vivo dynamic motion analysis of anterior cruciate ligament-deficient knees during squatting using geometric center axis of the femur. J Orthop Sci 21:159–165CrossRefPubMed
26.
go back to reference Pagnano MW, Hanssen AD, Lewallen DG, Stuart MJ (1998) Flexion instability after primary posterior cruciate retaining total knee arthroplasty. Clin Orthop Relat Res 356:39–46CrossRef Pagnano MW, Hanssen AD, Lewallen DG, Stuart MJ (1998) Flexion instability after primary posterior cruciate retaining total knee arthroplasty. Clin Orthop Relat Res 356:39–46CrossRef
27.
go back to reference Seon JK, Park SJ, Yoon TR, Lee KB, Moon ES, Song EK (2010) The effect of anteroposterior laxity on the range of movement and knee function following a cruciate-retaining total knee replacement. J Bone Joint Surg [Br] 92-B:1090–1095CrossRef Seon JK, Park SJ, Yoon TR, Lee KB, Moon ES, Song EK (2010) The effect of anteroposterior laxity on the range of movement and knee function following a cruciate-retaining total knee replacement. J Bone Joint Surg [Br] 92-B:1090–1095CrossRef
28.
go back to reference Sato T, Koga Y, Omori G (2004) Three-dimensional lower extremity alignment assessment system: application to evaluation of component position after total knee arthroplasty. J Arthroplasty 19:620–628CrossRefPubMed Sato T, Koga Y, Omori G (2004) Three-dimensional lower extremity alignment assessment system: application to evaluation of component position after total knee arthroplasty. J Arthroplasty 19:620–628CrossRefPubMed
29.
go back to reference Sato T, Koga Y, Sobue T, Omori G, Tanabe Y, Sakamoto M (2007) Quantitative 3-dimensional analysis of preoperative and postoperative joint lines in total kneearthroplasty: a new concept for evaluation of component alignment. J Arthroplasty 22:560–568CrossRefPubMed Sato T, Koga Y, Sobue T, Omori G, Tanabe Y, Sakamoto M (2007) Quantitative 3-dimensional analysis of preoperative and postoperative joint lines in total kneearthroplasty: a new concept for evaluation of component alignment. J Arthroplasty 22:560–568CrossRefPubMed
30.
go back to reference Scuderi GR, Insall JN, Windsor RE, Moran MC (1989) Survivorship of cemented knee replacements. J Bone Joint Surg Br 71:798–803CrossRefPubMed Scuderi GR, Insall JN, Windsor RE, Moran MC (1989) Survivorship of cemented knee replacements. J Bone Joint Surg Br 71:798–803CrossRefPubMed
31.
go back to reference Tanifuji O, Sato T, Kobayashi K, Mochizuki T, Koga Y, Yamagiwa H, Omori G, Endo N (2011) Three-dimensional in vivo motion analysis of normal knees using single-plane fluoroscopy. J Orthop Sci 16:710–718CrossRefPubMed Tanifuji O, Sato T, Kobayashi K, Mochizuki T, Koga Y, Yamagiwa H, Omori G, Endo N (2011) Three-dimensional in vivo motion analysis of normal knees using single-plane fluoroscopy. J Orthop Sci 16:710–718CrossRefPubMed
32.
go back to reference Tanifuji O, Sato T, Kobayashi K, Mochizuki T, Koga Y, Yamagiwa H, Omori G, Endo N (2013) Three-dimensional in vivo motion analysis of normal knees employing transepicondylar axis as an evaluation parameter. Knee Surg Sports Traumatol Arthrosc 21:2301–2308CrossRefPubMed Tanifuji O, Sato T, Kobayashi K, Mochizuki T, Koga Y, Yamagiwa H, Omori G, Endo N (2013) Three-dimensional in vivo motion analysis of normal knees employing transepicondylar axis as an evaluation parameter. Knee Surg Sports Traumatol Arthrosc 21:2301–2308CrossRefPubMed
34.
go back to reference Vince K (2016) Mid-flexion instability after total knee arthroplasty: woolly thinking or a real concern? Bone Joint J 98-B:84–88CrossRefPubMed Vince K (2016) Mid-flexion instability after total knee arthroplasty: woolly thinking or a real concern? Bone Joint J 98-B:84–88CrossRefPubMed
35.
go back to reference Warren PJ, Olanlokun TK, Walker PS, Walker PS, Iverson BF (1994) Laxity and function in knee replacements. Clin Orthop Relat Res 305:200–208CrossRef Warren PJ, Olanlokun TK, Walker PS, Walker PS, Iverson BF (1994) Laxity and function in knee replacements. Clin Orthop Relat Res 305:200–208CrossRef
36.
go back to reference Watanabe S, Sato T, Omori G, Koga Y, Endo N (2014) Change in tibiofemoral rotational alignment during total knee arthroplasty. J Orthop Sci 19:571–578CrossRefPubMed Watanabe S, Sato T, Omori G, Koga Y, Endo N (2014) Change in tibiofemoral rotational alignment during total knee arthroplasty. J Orthop Sci 19:571–578CrossRefPubMed
37.
go back to reference Yoon JR, Jeong HI, Oh KJ, Yang JH (2013) In vivo gap analysis in various knee flexion angles during navigation-assisted total knee arthroplasty. J Arthroplasty 28:1796–1800CrossRefPubMed Yoon JR, Jeong HI, Oh KJ, Yang JH (2013) In vivo gap analysis in various knee flexion angles during navigation-assisted total knee arthroplasty. J Arthroplasty 28:1796–1800CrossRefPubMed
38.
go back to reference Zaffagnini S, Bignozzi S, Saffarini M, Colle F, Sharma B, Kinov PS, Marcacci M, Dejour D (2014) Comparison of stability and kinematics of the natural knee versus a PS TKA with a ‘third condyle’. Knee Surg Sports Traumatol Arthrosc 22:1778–1785CrossRefPubMed Zaffagnini S, Bignozzi S, Saffarini M, Colle F, Sharma B, Kinov PS, Marcacci M, Dejour D (2014) Comparison of stability and kinematics of the natural knee versus a PS TKA with a ‘third condyle’. Knee Surg Sports Traumatol Arthrosc 22:1778–1785CrossRefPubMed
Metadata
Title
Association between anteroposterior laxity in mid-range flexion and subjective healing of instability after total knee arthroplasty
Authors
Tomoharu Mochizuki
Osamu Tanifuji
Takashi Sato
Hiroki Hijikata
Hiroshi Koga
Satoshi Watanabe
Yukimasa Higano
Akihiro Ariumi
Takayuki Murayama
Hiroshi Yamagiwa
Naoto Endo
Publication date
01-11-2017
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 11/2017
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-016-4375-8

Other articles of this Issue 11/2017

Knee Surgery, Sports Traumatology, Arthroscopy 11/2017 Go to the issue