Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 10/2013

01-10-2013 | Knee

Patient-specific total knee arthroplasty: the importance of planning by the surgeon

Authors: M. Pietsch, O. Djahani, M. Hochegger, F. Plattner, S. Hofmann

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 10/2013

Login to get access

Abstract

Purpose

The purpose of the study was to evaluate the accuracy of the planning of the patient-specific pin guides in total knee arthroplasty (TKA). This planning was performed primarily by a technician of the company and offered to the surgeon. All parameters of the implantation can either be modified or accepted by the surgeon. The hypothesis was that the plan needs preoperative intervention by the surgeon.

Methods

A prospective study in 50 patients was carried out. All patients received the same posterior-stabilised implant with patient-specific instrumentation. All surgical parameters (coronal, sagittal, rotational alignment, femoral and tibial resection levels and implant sizes) were checked by the orthopaedic surgeon and changed if necessary.

Results

Preoperatively, the femoral size was changed in 8 patients (16 %), the femoral flexion in 23 patients (46 %), the femoral shift in 34 patients (68 %), the tibial size in 24 patients (48 %) and the tibial rotation in all patients. The epicondylar axis was accepted in 47 patients (94 %) in the technician plan. Mean planning time was 8 ± 4 min. Intraoperatively, the femoral anterior–posterior size was in 50 patients (100 %) the same as in the surgeon and in 42 patients (84 %) the same as in the technician plan (p = 0.003). The tibial component implanted was in 42 patients (84 %) the same as in the surgeon and in 19 patients (38 %) the same as in the technician plan (p < 0.0001). A femoral distal recut was necessary in 31 patients (62 %) and a change of the tibial proximal cut in 17 patients (34 %) during surgery. Intraoperatively, no changes of the femoral and tibial alignment, the femoral anterior–posterior size, the femoral flexion, the femoral shift, the femoral and tibial rotation were necessary. Postoperatively, the coronal mechanical overall axis was within ±3° in 47 patients (94 %) with a maximum deviation of 5.6°.

Conclusions

Significant changes of the technician plan were necessary to get an accurate preoperative plan. Intraoperative changes were significant less compared to the surgeon than to the technician plan. No major changes (alignment, femoral anterior–posterior size and rotation) of the surgeon plan were necessary. Surgeons using patient-specific pin guides in TKA may verify the default plan provided by the technician. A blind reply on the technician plan may be not recommended.

Level of evidence

Therapeutic study, Level III.
Literature
1.
go back to reference Akagi M, Oh M, Nonaka T et al (2004) An anteroposterior axis of the tibia for total knee arthroplasty. Clin Orthop Relat Res 420:213–219PubMedCrossRef Akagi M, Oh M, Nonaka T et al (2004) An anteroposterior axis of the tibia for total knee arthroplasty. Clin Orthop Relat Res 420:213–219PubMedCrossRef
2.
go back to reference Bali K, Walker P, Bruce W (2012) Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplasty 27:1149–1154PubMedCrossRef Bali K, Walker P, Bruce W (2012) Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplasty 27:1149–1154PubMedCrossRef
3.
go back to reference Bathis H, Perlick L, Tingart M et al (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef Bathis H, Perlick L, Tingart M et al (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687PubMedCrossRef
4.
go back to reference Berger RA, Crossett LS, Jacobs JJ et al (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153PubMedCrossRef Berger RA, Crossett LS, Jacobs JJ et al (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153PubMedCrossRef
5.
go back to reference Chin PL, Yang KY, Yeo SJ et al (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618–626PubMedCrossRef Chin PL, Yang KY, Yeo SJ et al (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618–626PubMedCrossRef
6.
go back to reference Cobb JP, Dixon H, Dandachli W et al (2008) The anatomical tibial axis: reliable rotational orientation in knee replacement. J Bone Joint Surg Br 90:1032–1038PubMedCrossRef Cobb JP, Dixon H, Dandachli W et al (2008) The anatomical tibial axis: reliable rotational orientation in knee replacement. J Bone Joint Surg Br 90:1032–1038PubMedCrossRef
7.
go back to reference Dutton AQ, Yeo SJ, Yang KY et al (2008) Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Am 90:2–9PubMedCrossRef Dutton AQ, Yeo SJ, Yang KY et al (2008) Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Am 90:2–9PubMedCrossRef
9.
go back to reference Howell SM, Kuznik K, Hull ML et al (2008) Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 31:857–863PubMedCrossRef Howell SM, Kuznik K, Hull ML et al (2008) Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 31:857–863PubMedCrossRef
10.
go back to reference Incavo SJ, Coughlin KM, Pappas C et al (2003) Anatomic rotational relationships of the proximal tibia, distal femur, and patella: implications for rotational alignment in total knee arthroplasty. J Arthroplasty 18:643–648PubMedCrossRef Incavo SJ, Coughlin KM, Pappas C et al (2003) Anatomic rotational relationships of the proximal tibia, distal femur, and patella: implications for rotational alignment in total knee arthroplasty. J Arthroplasty 18:643–648PubMedCrossRef
11.
go back to reference Issa K, Rifai A, McGrath MS et al (2013) Reliability of templating with patient-specific instrumentation in total knee arthroplasty. J Knee Surg. doi:10.1055/s-0033-1343615 Issa K, Rifai A, McGrath MS et al (2013) Reliability of templating with patient-specific instrumentation in total knee arthroplasty. J Knee Surg. doi:10.​1055/​s-0033-1343615
12.
go back to reference Ng VY, Declaire JH, Berend KR et al (2011) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99–107CrossRef Ng VY, Declaire JH, Berend KR et al (2011) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99–107CrossRef
13.
go back to reference Noble JW Jr, Moore CA, Liu N (2012) The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty 27:153–155PubMedCrossRef Noble JW Jr, Moore CA, Liu N (2012) The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty 27:153–155PubMedCrossRef
14.
go back to reference Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 280:65–71PubMed Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 280:65–71PubMed
15.
go back to reference Pietsch M, Djahani O, Zweiger C et al (2012) Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-012-2284-z Pietsch M, Djahani O, Zweiger C et al (2012) Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-012-2284-z
16.
go back to reference Pietsch M, Hofmann S (2012) Early revision for isolated internal malrotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:1057–1063PubMedCrossRef Pietsch M, Hofmann S (2012) Early revision for isolated internal malrotation of the femoral component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:1057–1063PubMedCrossRef
17.
go back to reference Spencer BA, Mont MA, McGrath MS et al (2009) Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop 33:1571–1575PubMedCrossRef Spencer BA, Mont MA, McGrath MS et al (2009) Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop 33:1571–1575PubMedCrossRef
18.
go back to reference Stronach BM, Pelt CE, Erickson J et al (2013) Patient-specific total knee arthroplasty required frequent surgeon-directed changes. Clin Orthop Relat Res 471:169–174PubMedCrossRef Stronach BM, Pelt CE, Erickson J et al (2013) Patient-specific total knee arthroplasty required frequent surgeon-directed changes. Clin Orthop Relat Res 471:169–174PubMedCrossRef
19.
go back to reference Victor J, Dujardin J, Vandenneucker H et al (2013) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res. doi:10.1007/s11999-013-2997-4 Victor J, Dujardin J, Vandenneucker H et al (2013) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res. doi:10.​1007/​s11999-013-2997-4
20.
go back to reference Whiteside LA, Arima J (1995) The anteroposterior axis for femoral rotational alignment in valgus total knee arthroplasty. Clin Orthop Relat Res 321:168–172PubMed Whiteside LA, Arima J (1995) The anteroposterior axis for femoral rotational alignment in valgus total knee arthroplasty. Clin Orthop Relat Res 321:168–172PubMed
21.
go back to reference Yoo JH, Chang CB, Shin KS et al (2008) Anatomical references to assess the posterior tibial slope in total knee arthroplasty: a comparison of 5 anatomical axes. J Arthroplasty 23:586–592PubMedCrossRef Yoo JH, Chang CB, Shin KS et al (2008) Anatomical references to assess the posterior tibial slope in total knee arthroplasty: a comparison of 5 anatomical axes. J Arthroplasty 23:586–592PubMedCrossRef
Metadata
Title
Patient-specific total knee arthroplasty: the importance of planning by the surgeon
Authors
M. Pietsch
O. Djahani
M. Hochegger
F. Plattner
S. Hofmann
Publication date
01-10-2013
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 10/2013
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-013-2624-7

Other articles of this Issue 10/2013

Knee Surgery, Sports Traumatology, Arthroscopy 10/2013 Go to the issue