The risk of notching the anterior femoral cortex with the use of navigation systems in total knee arthroplasty

Authors: Yukihide Minoda, Akio Kobayashi, Hiroyoshi Iwaki, Ikebuchi Mitsuhiko, Yoshinori Kadoya, Hirotsugu Ohashi, Kunio Takaoka, Hiroaki Nakamura

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 6/2010

Login to get access

Abstract

Use of navigation systems has recently been introduced in total knee arthroplasty (TKA) to achieve more reliable prosthetic alignment. In the sagittal plane, there are two important requirements for navigation systems: (1) perpendicular cut to the femoral mechanical axis and (2) prevention of notching of anterior femoral cortex. These two requirements, however, may conflict. The angles between the line of the anterior femoral cortex and four sagittal femoral mechanical axes for navigation systems using radiographs of the entire lower extremity, while standing were measured and compared. These four sagittal axes simulated on the radiographs in navigation systems were in extension relative to the line of the anterior femoral cortex in 40–85% of cases in male and 65–100% in elderly female. The present study showed that navigation systems have the potential risk for notching of anterior femoral cortex.
Literature
1.
go back to reference Bathis H, Perlick L, Tingart M et al (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687CrossRefPubMed Bathis H, Perlick L, Tingart M et al (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682–687CrossRefPubMed
2.
go back to reference Berger RA, Rubash HE, Seel MJ et al (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47PubMed Berger RA, Rubash HE, Seel MJ et al (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47PubMed
3.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310PubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310PubMed
4.
go back to reference Bolognesi M, Hofmann A (2005) Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res 440:162–169CrossRefPubMed Bolognesi M, Hofmann A (2005) Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res 440:162–169CrossRefPubMed
5.
go back to reference Bonutti PM, Dethmers DA, McGrath MS et al (2008) Navigation did not improve the precision of minimally invasive knee arthroplasty. Clin Orthop Relat Res 466:2730–2735CrossRefPubMed Bonutti PM, Dethmers DA, McGrath MS et al (2008) Navigation did not improve the precision of minimally invasive knee arthroplasty. Clin Orthop Relat Res 466:2730–2735CrossRefPubMed
6.
go back to reference Chauhan SK, Clark GW, Lloyd S et al (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol). J Bone Joint Surg Br 86:818–823CrossRefPubMed Chauhan SK, Clark GW, Lloyd S et al (2004) Computer-assisted total knee replacement. A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol). J Bone Joint Surg Br 86:818–823CrossRefPubMed
7.
go back to reference Clarke HD, Hentz JG (2008) Restoration of femoral anatomy in TKA with unisex and gender-specific components. Clin Orthop Relat Res 466:2711–2716CrossRefPubMed Clarke HD, Hentz JG (2008) Restoration of femoral anatomy in TKA with unisex and gender-specific components. Clin Orthop Relat Res 466:2711–2716CrossRefPubMed
8.
go back to reference Haaker RG, Stockheim M, Kamp M et al (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159CrossRefPubMed Haaker RG, Stockheim M, Kamp M et al (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159CrossRefPubMed
9.
go back to reference Hart R, Janecek M, Cizmár I et al (2006) Minimally invasive and navigated implantation for total knee arthroplasty: X-ray analysis and early clinical results. Orthopade 35:552–557CrossRefPubMed Hart R, Janecek M, Cizmár I et al (2006) Minimally invasive and navigated implantation for total knee arthroplasty: X-ray analysis and early clinical results. Orthopade 35:552–557CrossRefPubMed
10.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed
11.
go back to reference Jenny JY, Clemens U, Kohler S et al (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case–control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839CrossRefPubMed Jenny JY, Clemens U, Kohler S et al (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case–control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839CrossRefPubMed
12.
go back to reference Lesh ML, Schneider DJ, Deol G et al (2000) The consequences of anterior femoral notching in total knee arthroplasty. A biomechanical study. J Bone Joint Surg Am 82:1096–1101PubMed Lesh ML, Schneider DJ, Deol G et al (2000) The consequences of anterior femoral notching in total knee arthroplasty. A biomechanical study. J Bone Joint Surg Am 82:1096–1101PubMed
13.
go back to reference Lützner J, Krummenauer F, Wolf C et al (2008) Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br 90:1039–1044CrossRefPubMed Lützner J, Krummenauer F, Wolf C et al (2008) Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br 90:1039–1044CrossRefPubMed
14.
go back to reference Middleton FR, Palmer SH (2007) How accurate is Whiteside’s line as a reference axis in total knee arthroplasty? Knee 14:204–207CrossRefPubMed Middleton FR, Palmer SH (2007) How accurate is Whiteside’s line as a reference axis in total knee arthroplasty? Knee 14:204–207CrossRefPubMed
15.
go back to reference Minoda Y, Kobayashi A, Iwaki H et al (2008) Sagittal alignment of the lower extremity while standing in Japanese male. Arch Orthop Trauma Surg 128:435–442CrossRefPubMed Minoda Y, Kobayashi A, Iwaki H et al (2008) Sagittal alignment of the lower extremity while standing in Japanese male. Arch Orthop Trauma Surg 128:435–442CrossRefPubMed
16.
go back to reference Minoda Y, Kobayashi A, Iwaki H et al (2009) TKA sagittal alignment with navigation systems and conventional techniques vary only a few degrees. Clin Orthop Relat Res 467:1000–1006CrossRefPubMed Minoda Y, Kobayashi A, Iwaki H et al (2009) TKA sagittal alignment with navigation systems and conventional techniques vary only a few degrees. Clin Orthop Relat Res 467:1000–1006CrossRefPubMed
17.
go back to reference Mizu-uchi H, Matsuda S, Miura H et al (2008) The evaluation of post-operative alignment in total knee replacement using a CT-based navigation system. J Bone Joint Surg Br 90:1025–1031CrossRefPubMed Mizu-uchi H, Matsuda S, Miura H et al (2008) The evaluation of post-operative alignment in total knee replacement using a CT-based navigation system. J Bone Joint Surg Br 90:1025–1031CrossRefPubMed
18.
go back to reference Oswald MH, Jakob RP, Schneider E et al (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426CrossRefPubMed Oswald MH, Jakob RP, Schneider E et al (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426CrossRefPubMed
19.
go back to reference Sparmann M, Wolke B, Czupalla H et al (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed Sparmann M, Wolke B, Czupalla H et al (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed
20.
go back to reference Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop Relat Res 416:177–184CrossRefPubMed Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop Relat Res 416:177–184CrossRefPubMed
21.
go back to reference Tew M, Waugh W (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg Br 67:551–556PubMed Tew M, Waugh W (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg Br 67:551–556PubMed
22.
go back to reference Tria AJ Jr (2006) The evolving role of navigation in minimally invasive total knee arthroplasty. Am J Orthop 35(7 Suppl):18–22PubMed Tria AJ Jr (2006) The evolving role of navigation in minimally invasive total knee arthroplasty. Am J Orthop 35(7 Suppl):18–22PubMed
23.
go back to reference Wasielewski RC, Galante JO, Leighty RM et al (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43PubMed Wasielewski RC, Galante JO, Leighty RM et al (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43PubMed
24.
go back to reference Zalzal P, Backstein D, Gross AE et al (2006) Notching of the anterior femoral cortex during total knee arthroplasty characteristics that increase local stresses. J Arthroplasty 21:737–743CrossRefPubMed Zalzal P, Backstein D, Gross AE et al (2006) Notching of the anterior femoral cortex during total knee arthroplasty characteristics that increase local stresses. J Arthroplasty 21:737–743CrossRefPubMed
Metadata
Title
The risk of notching the anterior femoral cortex with the use of navigation systems in total knee arthroplasty
Authors
Yukihide Minoda
Akio Kobayashi
Hiroyoshi Iwaki
Ikebuchi Mitsuhiko
Yoshinori Kadoya
Hirotsugu Ohashi
Kunio Takaoka
Hiroaki Nakamura
Publication date
01-06-2010
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 6/2010
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-009-0927-5

Other articles of this Issue 6/2010

Knee Surgery, Sports Traumatology, Arthroscopy 6/2010 Go to the issue