Abstract

Objective

Dopamine transporter single-photon emission computed tomography (DAT SPECT) has been widely used to diagnose Parkinson syndrome. Using the standardized uptake value (SUV) of DAT SPECT, we propose “functional dopamine transporter volume (f-DTV)” as a new quantitative index to evaluate the three-dimensional volume of functional dopamine transporters and assess its diagnostic ability in differentiating dopaminergic neurodegenerative diseases (dNDD) from non-dNDD.

Methods

Seventy-nine patients were enrolled (42 dNDD, 37 non-dNDD; 38 men; age 24–88 years). We analyzed seven quantitative indices. The specific binding ratio (SBR) was calculated using a program specialized for DAT SPECT (SBR_Bolt). The SUVmax, SUVpeak, and SUVmean were calculated using a quantification program for bone SPECT. SBR_SUV was calculated by dividing striatal SUVmean by the average of background SUVmean. The cutoff value of the active dopamine transporter level was examined using three methods (threshold of 40% of SUVmax, SUV 2, and SUV 3) to calculate the active dopamine transporter volume (ADV). The f-DTV was calculated by multiplying ADV and SUVmean. We assessed the correlations between SBR_Bolt and SBR_SUV, and compared the mean value of each index between the dNDD and non-dNDD groups. The abilities of SBR_Bolt, SBR_SUV, SUVmax, SUVpeak, SUVmean, ADV, and f-DTV in differentiating dNDD from non-dNDD were determined by the area under the receiver operating curve (AUC) generated by the receiver operating characteristics analysis.

Results

The SBR_Bolt and SBR_SUV highly correlated with each other (r = 0.71). The cutoff value of the active dopamine transporter level was determined as SUV 3. All seven quantitative indices showed lower values in the dNDD group than in the non-dNDD group, and the difference between the two groups was statistically significant (p < 0.05). Sensitivity, specificity, and AUC of f-DTV were slightly lower than those of SBR_Bolt (71%, 79%, and 0.81, respectively, for f-DTV, and 81%, 84%, 0.88, respectively, for SBR_Bolt). The difference in AUC between f-DTV and SBR_Bolt was not statistically significant.

Conclusions

This study demonstrates the utility of f-DTV as a novel quantitative index for evaluating the three-dimensional volume of functional dopamine transporters, and that f-DTV has almost the same diagnostic ability to differentiate dNDD from non-dNDD using DAT SPECT.
Literature
4.
go back to reference JSNM (Japanese Society of Nuclear Medicine). Clinical practice guideline for dopamine transporter imaging with 123I-ioflupane SPECT ver.2 JSNM 2017 JSNM (Japanese Society of Nuclear Medicine). Clinical practice guideline for dopamine transporter imaging with 123I-ioflupane SPECT ver.2 JSNM 2017
6.
go back to reference Davidsson A, Georgiopoulos C, Dizdar N, Granerus G, Zachrisson H. Comparison between visual assessment of dopaminergic degeneration pattern and semi-quantitative ratio calculations in patients with Parkinson’s disease and atypical Parkinsonian syndromes using DaTSCAN® SPECT. Ann Nucl Med. 2014;28:851–9. https://doi.org/10.1007/s12149-014-0878-x.CrossRefPubMed Davidsson A, Georgiopoulos C, Dizdar N, Granerus G, Zachrisson H. Comparison between visual assessment of dopaminergic degeneration pattern and semi-quantitative ratio calculations in patients with Parkinson’s disease and atypical Parkinsonian syndromes using DaTSCAN® SPECT. Ann Nucl Med. 2014;28:851–9. https://​doi.​org/​10.​1007/​s12149-014-0878-x.CrossRefPubMed
11.
go back to reference Wei H, Weihao Z, Jiadong X, Hacker M, Bertling J, Lewis R, et al. Standardized uptake values of 99mTc-MDP SPECT bone scans - a novel method for absolute SPECT/CT quantification. J Nucl Med 2015;56(Suppl 3):1790 Wei H, Weihao Z, Jiadong X, Hacker M, Bertling J, Lewis R, et al. Standardized uptake values of 99mTc-MDP SPECT bone scans - a novel method for absolute SPECT/CT quantification. J Nucl Med 2015;56(Suppl 3):1790
17.
go back to reference Bieńkiewicz M, Górska-Chrzastek M, Siennicki J, Gajos A, Bogucki A, Mochecka-Thoelke A, et al. Impact of CT based attenuation correction on quantitative assessment of DaTSCAN ((123)I-Ioflupane) imaging in diagnosis of extrapyramidal diseases. Nucl Med Rev Cent East Eur. 2008;11:53–8.PubMed Bieńkiewicz M, Górska-Chrzastek M, Siennicki J, Gajos A, Bogucki A, Mochecka-Thoelke A, et al. Impact of CT based attenuation correction on quantitative assessment of DaTSCAN ((123)I-Ioflupane) imaging in diagnosis of extrapyramidal diseases. Nucl Med Rev Cent East Eur. 2008;11:53–8.PubMed
25.
Metadata
Title
A new quantitative index in the diagnosis of Parkinson syndrome by dopamine transporter single-photon emission computed tomography
Authors
Ryota Bando
Hideki Otsuka
Tamaki Otani
Noritake Matsuda
Shota Azane
Yamato Kunikane
Yoichi Otomi
Wataru Sako
Yuishin Izumi
Masafumi Harada
Publication date
01-04-2021
Publisher
Springer Singapore
Published in
Annals of Nuclear Medicine / Issue 4/2021
Print ISSN: 0914-7187
Electronic ISSN: 1864-6433
DOI
https://doi.org/10.1007/s12149-021-01592-w

Other articles of this Issue 4/2021

Annals of Nuclear Medicine 4/2021 Go to the issue