Abstract

Ensuring and maintaining adequate tissue oxygenation at the microcirculatory level might be considered the holy grail of optimal hemodynamic patient management. However, in clinical practice we usually focus on macro-hemodynamic variables such as blood pressure, heart rate, and sometimes cardiac output. Other macro-hemodynamic variables like pulse pressure or stroke volume variation are additionally used as markers of fluid responsiveness. In recent years, an increasing number of technological devices assessing tissue oxygenation or microcirculatory blood flow have been developed and validated, and some of them have already been incorporated into clinical practice. In this review, we will summarize recent research findings on this topic as published in the last 2 years in the Journal of Clinical Monitoring and Computing (JCMC). While some techniques are already currently used as routine monitoring (e.g. cerebral oxygenation using near-infrared spectroscopy (NIRS)), others still have to find their way into clinical practice. Therefore, further research is needed, particularly regarding outcome measures and cost-effectiveness, since introducing new technology is always expensive and should be balanced by downstream savings. The JCMC is glad to provide a platform for such research.
Literature
1.
go back to reference Pickard A, Karlen W, Ansermino JM. Capillary refill time: is it still a useful clinical sign? Anesth Analg. 2011;113(1):120–3.PubMedCrossRef Pickard A, Karlen W, Ansermino JM. Capillary refill time: is it still a useful clinical sign? Anesth Analg. 2011;113(1):120–3.PubMedCrossRef
2.
go back to reference Shinozaki K, et al. Evaluation of accuracy of capillary refill index with pneumatic fingertip compression. J Clin Monit Comput. 2021;35(1):135–45.PubMedCrossRef Shinozaki K, et al. Evaluation of accuracy of capillary refill index with pneumatic fingertip compression. J Clin Monit Comput. 2021;35(1):135–45.PubMedCrossRef
3.
go back to reference Heeman W, et al. Clinical applications of laser speckle contrast imaging: a review. J Biomed Opt. 2019;24(8):1–11.PubMedCrossRef Heeman W, et al. Clinical applications of laser speckle contrast imaging: a review. J Biomed Opt. 2019;24(8):1–11.PubMedCrossRef
4.
go back to reference Motoyama Y, et al. Ocular blood flow by laser speckle flowgraphy to detect cerebral ischemia during carotid endarterectomy. J Clin Monit Comput. 2021;35(2):327–36.PubMedCrossRef Motoyama Y, et al. Ocular blood flow by laser speckle flowgraphy to detect cerebral ischemia during carotid endarterectomy. J Clin Monit Comput. 2021;35(2):327–36.PubMedCrossRef
5.
go back to reference Niemann MJ, et al. Laser speckle contrast imaging of forehead cutaneous blood flow during carotid endarterectomy as a potential non-invasive method for surrogate monitoring of cerebral perfusion. J Clin Monit Comput. 2021;35(6):1263–8.PubMedCrossRef Niemann MJ, et al. Laser speckle contrast imaging of forehead cutaneous blood flow during carotid endarterectomy as a potential non-invasive method for surrogate monitoring of cerebral perfusion. J Clin Monit Comput. 2021;35(6):1263–8.PubMedCrossRef
6.
go back to reference Bruins AA, et al. The vascular occlusion test using multispectral imaging: a validation study : the VASOIMAGE study. J Clin Monit Comput. 2021;35(1):113–21.PubMedCrossRef Bruins AA, et al. The vascular occlusion test using multispectral imaging: a validation study : the VASOIMAGE study. J Clin Monit Comput. 2021;35(1):113–21.PubMedCrossRef
7.
go back to reference Coppel J, et al. A comparison of the quality of image acquisition between two different sidestream dark field video-microscopes. J Clin Monit Comput. 2021;35(3):577–83.PubMedCrossRef Coppel J, et al. A comparison of the quality of image acquisition between two different sidestream dark field video-microscopes. J Clin Monit Comput. 2021;35(3):577–83.PubMedCrossRef
8.
go back to reference Ince C, et al. Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2018;44(3):281–99.PubMedCrossRef Ince C, et al. Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2018;44(3):281–99.PubMedCrossRef
9.
go back to reference Massey MJ, et al. The microcirculation image quality score: development and preliminary evaluation of a proposed approach to grading quality of image acquisition for bedside videomicroscopy. J Crit Care. 2013;28(6):913–7.PubMedCrossRef Massey MJ, et al. The microcirculation image quality score: development and preliminary evaluation of a proposed approach to grading quality of image acquisition for bedside videomicroscopy. J Crit Care. 2013;28(6):913–7.PubMedCrossRef
10.
go back to reference Hilty MP, et al. MicroTools enables automated quantification of capillary density and red blood cell velocity in handheld vital microscopy. Commun Biol. 2019;2:217.PubMedPubMedCentralCrossRef Hilty MP, et al. MicroTools enables automated quantification of capillary density and red blood cell velocity in handheld vital microscopy. Commun Biol. 2019;2:217.PubMedPubMedCentralCrossRef
11.
go back to reference Xu L, et al. Transcutaneous oxygen pressure-related variables as noninvasive indicators of low lactate clearance in sepsis patients after resuscitation. J Clin Monit Comput. 2021;35(3):435–42.PubMedCrossRef Xu L, et al. Transcutaneous oxygen pressure-related variables as noninvasive indicators of low lactate clearance in sepsis patients after resuscitation. J Clin Monit Comput. 2021;35(3):435–42.PubMedCrossRef
13.
go back to reference Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007;28(3):R1-39.PubMedCrossRef Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007;28(3):R1-39.PubMedCrossRef
14.
go back to reference Kim SH, et al. Accuracy of continuous noninvasive hemoglobin monitoring: a systematic review and meta-analysis. Anesth Analg. 2014;119(2):332–46.PubMedCrossRef Kim SH, et al. Accuracy of continuous noninvasive hemoglobin monitoring: a systematic review and meta-analysis. Anesth Analg. 2014;119(2):332–46.PubMedCrossRef
15.
go back to reference Shabaninejad H, et al. Comparison of invasive and noninvasive blood hemoglobin measurement in the operating room: a systematic review and meta-analysis. J Anesth. 2019;33(3):441–53.PubMedCrossRef Shabaninejad H, et al. Comparison of invasive and noninvasive blood hemoglobin measurement in the operating room: a systematic review and meta-analysis. J Anesth. 2019;33(3):441–53.PubMedCrossRef
16.
go back to reference De Rosa RC, et al. Accuracy and trending ability of hemoglobin measurement by the pulse CO-oximeter during vascular surgery. J Clin Monit Comput. 2020;34(3):501–8.PubMedCrossRef De Rosa RC, et al. Accuracy and trending ability of hemoglobin measurement by the pulse CO-oximeter during vascular surgery. J Clin Monit Comput. 2020;34(3):501–8.PubMedCrossRef
17.
go back to reference Applegate Ii RL, et al. Correction to: multicenter comparison of three intraoperative hemoglobin trend monitoring methods. J Clin Monit Comput. 2021;35(3):677–8.PubMedCrossRef Applegate Ii RL, et al. Correction to: multicenter comparison of three intraoperative hemoglobin trend monitoring methods. J Clin Monit Comput. 2021;35(3):677–8.PubMedCrossRef
18.
go back to reference Cros J, et al. Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality. J Clin Monit Comput. 2020;34(4):683–91.PubMedCrossRef Cros J, et al. Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality. J Clin Monit Comput. 2020;34(4):683–91.PubMedCrossRef
19.
go back to reference Tusman G, Bohm SH, Suarez-Sipmann F. Advanced uses of pulse oximetry for monitoring mechanically ventilated patients. Anesth Analg. 2017;124(1):62–71.PubMedCrossRef Tusman G, Bohm SH, Suarez-Sipmann F. Advanced uses of pulse oximetry for monitoring mechanically ventilated patients. Anesth Analg. 2017;124(1):62–71.PubMedCrossRef
20.
go back to reference Klein AA, et al. Recommendations for standards of monitoring during anaesthesia and recovery 2021: guideline from the association of anaesthetists. Anaesthesia. 2021;76(9):1212–23.PubMedCrossRef Klein AA, et al. Recommendations for standards of monitoring during anaesthesia and recovery 2021: guideline from the association of anaesthetists. Anaesthesia. 2021;76(9):1212–23.PubMedCrossRef
21.
go back to reference Scheeren TWL, Belda FJ, Perel A. The oxygen reserve index (ORI): a new tool to monitor oxygen therapy. J Clin Monit Comput. 2018;32(3):379–89.PubMedCrossRef Scheeren TWL, Belda FJ, Perel A. The oxygen reserve index (ORI): a new tool to monitor oxygen therapy. J Clin Monit Comput. 2018;32(3):379–89.PubMedCrossRef
22.
go back to reference Tsymbal E, et al. Study of early warning for desaturation provided by Oxygen Reserve Index in obese patients. J Clin Monit Comput. 2021;35(4):749–56.PubMedCrossRef Tsymbal E, et al. Study of early warning for desaturation provided by Oxygen Reserve Index in obese patients. J Clin Monit Comput. 2021;35(4):749–56.PubMedCrossRef
23.
go back to reference Szmuk P, et al. Oxygen Reserve Index: a novel noninvasive measure of oxygen reserve—a pilot study. Anesthesiology. 2016;124(4):779–84.PubMedCrossRef Szmuk P, et al. Oxygen Reserve Index: a novel noninvasive measure of oxygen reserve—a pilot study. Anesthesiology. 2016;124(4):779–84.PubMedCrossRef
24.
go back to reference Barends CRM, et al. Moderate-to-deep sedation using target-controlled infusions of propofol and remifentanil: adverse events and risk factors: a retrospective cohort study of 2937 procedures. Anesth Analg. 2020;131(4):1173–83.PubMedCrossRef Barends CRM, et al. Moderate-to-deep sedation using target-controlled infusions of propofol and remifentanil: adverse events and risk factors: a retrospective cohort study of 2937 procedures. Anesth Analg. 2020;131(4):1173–83.PubMedCrossRef
25.
go back to reference Yoshida K, et al. Adjustment of oxygen reserve index (ORi) to avoid excessive hyperoxia during general anesthesia. J Clin Monit Comput. 2020;34(3):509–14.PubMedCrossRef Yoshida K, et al. Adjustment of oxygen reserve index (ORi) to avoid excessive hyperoxia during general anesthesia. J Clin Monit Comput. 2020;34(3):509–14.PubMedCrossRef
26.
go back to reference Coutrot M, et al. Perfusion index: Physical principles, physiological meanings and clinical implications in anaesthesia and critical care. Anaesth Crit Care Pain Med. 2021;40(6):100964.PubMedCrossRef Coutrot M, et al. Perfusion index: Physical principles, physiological meanings and clinical implications in anaesthesia and critical care. Anaesth Crit Care Pain Med. 2021;40(6):100964.PubMedCrossRef
27.
go back to reference Abdelhamid B, et al. The ability of perfusion index to detect segmental ulnar nerve sparing after supraclavicular nerve block. J Clin Monit Comput. 2020;34(6):1185–91.PubMedCrossRef Abdelhamid B, et al. The ability of perfusion index to detect segmental ulnar nerve sparing after supraclavicular nerve block. J Clin Monit Comput. 2020;34(6):1185–91.PubMedCrossRef
28.
go back to reference Depret F, et al. Monitoring tissue perfusion: a pilot clinical feasibility and safety study of a urethral photoplethysmography-derived perfusion device in high-risk patients. J Clin Monit Comput. 2020;34(5):961–9.PubMedCrossRef Depret F, et al. Monitoring tissue perfusion: a pilot clinical feasibility and safety study of a urethral photoplethysmography-derived perfusion device in high-risk patients. J Clin Monit Comput. 2020;34(5):961–9.PubMedCrossRef
29.
go back to reference Cardinali M, et al. A new photoplethysmographic device for continuous assessment of urethral mucosa perfusion: evaluation in a porcine model. J Clin Monit Comput. 2021;35(3):585–98.PubMedCrossRef Cardinali M, et al. A new photoplethysmographic device for continuous assessment of urethral mucosa perfusion: evaluation in a porcine model. J Clin Monit Comput. 2021;35(3):585–98.PubMedCrossRef
30.
go back to reference De Backer D, Ortiz JA, Salgado D. Coupling microcirculation to systemic hemodynamics. Curr Opin Crit Care. 2010;16(3):250–4.PubMedCrossRef De Backer D, Ortiz JA, Salgado D. Coupling microcirculation to systemic hemodynamics. Curr Opin Crit Care. 2010;16(3):250–4.PubMedCrossRef
31.
go back to reference Filho RR, et al. Assessment of the peripheral microcirculation in patients with and without shock: a pilot study on different methods. J Clin Monit Comput. 2020;34(6):1167–76.PubMedCrossRef Filho RR, et al. Assessment of the peripheral microcirculation in patients with and without shock: a pilot study on different methods. J Clin Monit Comput. 2020;34(6):1167–76.PubMedCrossRef
32.
go back to reference Kamata M, et al. Changes in cerebral and renal oxygenation during laparoscopic pyloromyotomy. J Clin Monit Comput. 2020;34(4):699–703.PubMedCrossRef Kamata M, et al. Changes in cerebral and renal oxygenation during laparoscopic pyloromyotomy. J Clin Monit Comput. 2020;34(4):699–703.PubMedCrossRef
33.
go back to reference Zdravkovic M, Podbregar M, Kamenik M. Near-infrared spectroscopy for assessing microcirculation during laparoscopic gynaecological surgery under combined spinal-general anaesthesia or general anaesthesia alone: a randomised controlled trial. J Clin Monit Comput. 2020;34(5):943–53.PubMedCrossRef Zdravkovic M, Podbregar M, Kamenik M. Near-infrared spectroscopy for assessing microcirculation during laparoscopic gynaecological surgery under combined spinal-general anaesthesia or general anaesthesia alone: a randomised controlled trial. J Clin Monit Comput. 2020;34(5):943–53.PubMedCrossRef
34.
go back to reference Fan X, et al. Do cerebral and somatic tissue oxygen saturation measurements correlate with each other during surgery? J Clin Monit Comput. 2020;34(3):483–90.PubMedCrossRef Fan X, et al. Do cerebral and somatic tissue oxygen saturation measurements correlate with each other during surgery? J Clin Monit Comput. 2020;34(3):483–90.PubMedCrossRef
35.
go back to reference Beck S, et al. Comparing the effect of positioning on cerebral autoregulation during radical prostatectomy: a prospective observational study. J Clin Monit Comput. 2021;35(4):891–901.PubMedCrossRef Beck S, et al. Comparing the effect of positioning on cerebral autoregulation during radical prostatectomy: a prospective observational study. J Clin Monit Comput. 2021;35(4):891–901.PubMedCrossRef
36.
go back to reference Giustiniano E, et al. May near infra-red spectroscopy and rapid perfusion pressure recovering be enough to rule out post-operative spinal cord injury? Two compared case-reports. J Clin Monit Comput. 2020;34(5):955–9.PubMedCrossRef Giustiniano E, et al. May near infra-red spectroscopy and rapid perfusion pressure recovering be enough to rule out post-operative spinal cord injury? Two compared case-reports. J Clin Monit Comput. 2020;34(5):955–9.PubMedCrossRef
37.
go back to reference Vanpeteghem CM, et al. Ephedrine and phenylephrine induce opposite changes in cerebral and paraspinal tissue oxygen saturation, measured with near-infrared spectroscopy: a randomized controlled trial. J Clin Monit Comput. 2020;34(2):253–9.PubMedCrossRef Vanpeteghem CM, et al. Ephedrine and phenylephrine induce opposite changes in cerebral and paraspinal tissue oxygen saturation, measured with near-infrared spectroscopy: a randomized controlled trial. J Clin Monit Comput. 2020;34(2):253–9.PubMedCrossRef
38.
go back to reference Nissen P, et al. Phenylephrine but not ephedrine reduces frontal lobe oxygenation following anesthesia-induced hypotension. Neurocrit Care. 2010;12(1):17–23.PubMedCrossRef Nissen P, et al. Phenylephrine but not ephedrine reduces frontal lobe oxygenation following anesthesia-induced hypotension. Neurocrit Care. 2010;12(1):17–23.PubMedCrossRef
39.
go back to reference Meng L, et al. Effect of phenylephrine and ephedrine bolus treatment on cerebral oxygenation in anaesthetized patients. Br J Anaesth. 2011;107(2):209–17.PubMedPubMedCentralCrossRef Meng L, et al. Effect of phenylephrine and ephedrine bolus treatment on cerebral oxygenation in anaesthetized patients. Br J Anaesth. 2011;107(2):209–17.PubMedPubMedCentralCrossRef
40.
go back to reference Stannard B, et al. Regional cerebral oximetry is consistent across self-reported racial groups and predicts 30-day mortality in cardiac surgery: a retrospective analysis. J Clin Monit Comput. 2021;35(2):413–21.PubMedCrossRef Stannard B, et al. Regional cerebral oximetry is consistent across self-reported racial groups and predicts 30-day mortality in cardiac surgery: a retrospective analysis. J Clin Monit Comput. 2021;35(2):413–21.PubMedCrossRef
41.
go back to reference Sun X, et al. Skin pigmentation interferes with the clinical measurement of regional cerebral oxygen saturation. Br J Anaesth. 2015;114(2):276–80.PubMedCrossRef Sun X, et al. Skin pigmentation interferes with the clinical measurement of regional cerebral oxygen saturation. Br J Anaesth. 2015;114(2):276–80.PubMedCrossRef
42.
go back to reference Genbrugge C, et al. Increase in regional cerebral saturation after elective electrical cardioversion of atrial fibrillation is only transient and without beneficial effects on neuropsychological functioning: cerebral saturation during electrical cardioversion. J Clin Monit Comput. 2021;35(1):165–73.PubMedCrossRef Genbrugge C, et al. Increase in regional cerebral saturation after elective electrical cardioversion of atrial fibrillation is only transient and without beneficial effects on neuropsychological functioning: cerebral saturation during electrical cardioversion. J Clin Monit Comput. 2021;35(1):165–73.PubMedCrossRef
43.
go back to reference Knecht S, et al. Atrial fibrillation in stroke-free patients is associated with memory impairment and hippocampal atrophy. Eur Heart J. 2008;29(17):2125–32.PubMedCrossRef Knecht S, et al. Atrial fibrillation in stroke-free patients is associated with memory impairment and hippocampal atrophy. Eur Heart J. 2008;29(17):2125–32.PubMedCrossRef
44.
go back to reference Soh S, et al. Preoperative transcranial Doppler and cerebral oximetry as predictors of delirium following valvular heart surgery: a case-control study. J Clin Monit Comput. 2020;34(4):715–23.PubMedCrossRef Soh S, et al. Preoperative transcranial Doppler and cerebral oximetry as predictors of delirium following valvular heart surgery: a case-control study. J Clin Monit Comput. 2020;34(4):715–23.PubMedCrossRef
45.
go back to reference Cho YJ, et al. Microcirculation measured by vascular occlusion test during desflurane-remifentanil anesthesia is superior to that in propofol-remifentanil anesthesia in patients undergoing thoracic surgery: subgroup analysis of a prospective randomized study. J Clin Monit Comput. 2017;31(5):989–97.PubMedCrossRef Cho YJ, et al. Microcirculation measured by vascular occlusion test during desflurane-remifentanil anesthesia is superior to that in propofol-remifentanil anesthesia in patients undergoing thoracic surgery: subgroup analysis of a prospective randomized study. J Clin Monit Comput. 2017;31(5):989–97.PubMedCrossRef
46.
go back to reference Cho YJ, Yoo SJ, Nam K, Bae JY, Lee SH, Jeon Y. Effects of anesthetics on microvascular reactivity measured by vascular occlusion tests during off-pump coronary artery bypass surgery: a randomized controlled trial. J Clin Monit Comput 2021;35:1219–28. Cho YJ, Yoo SJ, Nam K, Bae JY, Lee SH, Jeon Y. Effects of anesthetics on microvascular reactivity measured by vascular occlusion tests during off-pump coronary artery bypass surgery: a randomized controlled trial. J Clin Monit Comput 2021;35:1219–28.
47.
go back to reference Holmgaard F, et al. The response of a standardized fluid challenge during cardiac surgery on cerebral oxygen saturation measured with near-infrared spectroscopy. J Clin Monit Comput. 2020;34(2):245–51.PubMedCrossRef Holmgaard F, et al. The response of a standardized fluid challenge during cardiac surgery on cerebral oxygen saturation measured with near-infrared spectroscopy. J Clin Monit Comput. 2020;34(2):245–51.PubMedCrossRef
48.
go back to reference Vistisen ST, et al. Using extra systoles and the micro-fluid challenge to predict fluid responsiveness during cardiac surgery. J Clin Monit Comput. 2019;33(5):777–86.PubMedCrossRef Vistisen ST, et al. Using extra systoles and the micro-fluid challenge to predict fluid responsiveness during cardiac surgery. J Clin Monit Comput. 2019;33(5):777–86.PubMedCrossRef
Metadata
Title
What is new in microcirculation and tissue oxygenation monitoring?
Authors
Ilonka N. de Keijzer
Dario Massari
Marko Sahinovic
Moritz Flick
Jaap Jan Vos
Thomas W. L. Scheeren
Publication date
11-03-2022
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2022
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-022-00837-x

Other articles of this Issue 2/2022

Journal of Clinical Monitoring and Computing 2/2022 Go to the issue