Intraarterial catheter diameter and dynamic response of arterial pressure monitoring system: a randomized controlled trial

Authors: Hyongmin Oh, Suk Hyung Choe, Yoon Jung Kim, Hyun-Kyu Yoon, Hyung-Chul Lee, Hee-Pyoung Park

Published in: Journal of Clinical Monitoring and Computing | Issue 2/2022

Login to get access

Abstract

The dynamic response (DR) of the arterial pressure monitoring system (APMS) may depend on the intraarterial catheter (IAC) diameter. We hypothesized that adequate DR would be more common when using a smaller IAC. We compared the DR of the AMPS (Auto Transducer™) between three IACs (BD Angiocath Plus™) with different diameters. 353 neurosurgical patients were randomized into three groups undergoing catheterization with a 20-, 22-, or 24-gauge IAC: 20G (n = 119), 22G (n = 117), and 24G (n = 117) groups, respectively. The DR, which depends on the natural frequency and damping coefficient, was divided into four types: adequate (primary outcome measure), underdamped, overdamped, and unacceptable. The frequency of intraoperative IAC malfunction was noted. Adequate DR was observed more frequently in the 22G and 24G groups than the 20G group (13.7% and 15.4% vs. 4.2%, P = 0.011 and 0.004, respectively). The frequency of underdamped DR was higher in the 20G group than the 24G group (86.6% vs. 69.2%, P = 0.001), whereas overdamped DR was more frequent in the 24G group than the 20G and 22G groups (6.0% vs. 0.0% and 0.0%, P = 0.007 and 0.014, respectively). IAC malfunctioned more frequently during surgery in the 24G group than the 20G and 22G groups (15.4% vs. 0.0% and 1.7%, P < 0.001 and P < 0.001, respectively). The frequency of adequate DR was low regardless of the IAC diameter. Nonetheless, in terms of DR and IAC malfunction, a 22-gauge BD Angiocath Plus™ was more suitable for invasive blood pressure monitoring with Auto Transducer™ than a 20- or 24-gauge BD Angiocath Plus™. Registration Registry: ClinicalTrials.gov. Registration number: NCT03642756. Date of Registration: July 27, 2018.
Appendix
Available only for authorised users
Literature
1.
go back to reference Romagnoli S, Romano SM, Bevilacqua S, Lazzeri C, Gensini GF, Pratesi C, Quattrone D, Dini D, De Gaudio AR. Dynamic response of liquid-filled catheter systems for measurement of blood pressure: precision of measurements and reliability of the Pressure Recording Analytical Method with different disposable systems. J Crit Care. 2011;26:415–22. https://doi.org/10.1016/j.jcrc.2010.08.010.CrossRefPubMed Romagnoli S, Romano SM, Bevilacqua S, Lazzeri C, Gensini GF, Pratesi C, Quattrone D, Dini D, De Gaudio AR. Dynamic response of liquid-filled catheter systems for measurement of blood pressure: precision of measurements and reliability of the Pressure Recording Analytical Method with different disposable systems. J Crit Care. 2011;26:415–22. https://​doi.​org/​10.​1016/​j.​jcrc.​2010.​08.​010.CrossRefPubMed
3.
go back to reference Cousins TR, O’Donnell JM. Arterial cannulation: a critical review. AANA J. 2004;72:267–71.PubMed Cousins TR, O’Donnell JM. Arterial cannulation: a critical review. AANA J. 2004;72:267–71.PubMed
6.
go back to reference Miller RD. Miller’s anesthesia. 8th ed. Philadelphia: Elsevier/Saunders; 2015. p. 1351–4. Miller RD. Miller’s anesthesia. 8th ed. Philadelphia: Elsevier/Saunders; 2015. p. 1351–4.
8.
go back to reference Mark JB. Atlas of cardiovascular monitoring. New York: Churchill Livingstone; 1998. p. 105–18. Mark JB. Atlas of cardiovascular monitoring. New York: Churchill Livingstone; 1998. p. 105–18.
14.
go back to reference Fujiwara SJL, Tachihara K, Mori S, Ouchi K, Itakura S, Yasuda M, Hitosugi T, Imaizumi U, Miki Y, Toyoguchi I, Yoshida KI, Yokoyama T. Influence of the marvelous three-way stopcock on the natural frequency and damping coefficient in blood pressure transducer kits. J Clin Monit Comput. 2018;32:63–72. https://doi.org/10.1007/s10877-017-9979-0.CrossRefPubMed Fujiwara SJL, Tachihara K, Mori S, Ouchi K, Itakura S, Yasuda M, Hitosugi T, Imaizumi U, Miki Y, Toyoguchi I, Yoshida KI, Yokoyama T. Influence of the marvelous three-way stopcock on the natural frequency and damping coefficient in blood pressure transducer kits. J Clin Monit Comput. 2018;32:63–72. https://​doi.​org/​10.​1007/​s10877-017-9979-0.CrossRefPubMed
20.
go back to reference Rook WH, Turner JD, Clutton-Brock TH. Analysis of damping characteristics of arterial catheter blood pressure monitoring in a large intensive care unit. S Afr J Crti Care. 2017;33:8–10. Rook WH, Turner JD, Clutton-Brock TH. Analysis of damping characteristics of arterial catheter blood pressure monitoring in a large intensive care unit. S Afr J Crti Care. 2017;33:8–10.
32.
go back to reference Burns ER, Yoshikawa N. Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists. Lab Med. 2002;33:378–80.CrossRef Burns ER, Yoshikawa N. Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists. Lab Med. 2002;33:378–80.CrossRef
Metadata
Title
Intraarterial catheter diameter and dynamic response of arterial pressure monitoring system: a randomized controlled trial
Authors
Hyongmin Oh
Suk Hyung Choe
Yoon Jung Kim
Hyun-Kyu Yoon
Hyung-Chul Lee
Hee-Pyoung Park
Publication date
01-02-2021
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2022
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-021-00663-7

Other articles of this Issue 2/2022

Journal of Clinical Monitoring and Computing 2/2022 Go to the issue