Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 3/2013

01-03-2013 | Original Paper

CT coronary angiography: impact of adapted statistical iterative reconstruction (ASIR) on coronary stenosis and plaque composition analysis

Authors: Tobias A. Fuchs, Michael Fiechter, Cathérine Gebhard, Julia Stehli, Jelena R. Ghadri, Egle Kazakauskaite, Bernhard A. Herzog, Lars Husmann, Oliver Gaemperli, Philipp A. Kaufmann

Published in: The International Journal of Cardiovascular Imaging | Issue 3/2013

Login to get access

Abstract

To assess the impact of adaptive statistical iterative reconstruction (ASIR) on coronary plaque volume and composition analysis as well as on stenosis quantification in high definition coronary computed tomography angiography (CCTA). We included 50 plaques in 29 consecutive patients who were referred for the assessment of known or suspected coronary artery disease (CAD) with contrast-enhanced CCTA on a 64-slice high definition CT scanner (Discovery HD 750, GE Healthcare). CCTA scans were reconstructed with standard filtered back projection (FBP) with no ASIR (0 %) or with increasing contributions of ASIR, i.e. 20, 40, 60, 80 and 100 % (no FBP). Plaque analysis (volume, components and stenosis degree) was performed using a previously validated automated software. Mean values for minimal diameter and minimal area as well as degree of stenosis did not change significantly using different ASIR reconstructions. There was virtually no impact of reconstruction algorithms on mean plaque volume or plaque composition (e.g. soft, intermediate and calcified component). However, with increasing ASIR contribution, the percentage of plaque volume component between 401 and 500 HU decreased significantly (p < 0.05). Modern image reconstruction algorithms such as ASIR, which has been developed for noise reduction in latest high resolution CCTA scans, can be used reliably without interfering with the plaque analysis and stenosis severity assessment.
Literature
1.
go back to reference Schroeder S, Achenbach S, Bengel F, Burgstahler C, Cademartiri F, de Feyter P, George R, Kaufmann P, Kopp AF, Knuuti J, Ropers D, Schuijf J, Tops LF, Bax JJ (2008) Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a writing group deployed by the working group nuclear cardiology and cardiac CT of the European society of cardiology and the european council of nuclear cardiology. Eur Heart J 29(4):531–556PubMedCrossRef Schroeder S, Achenbach S, Bengel F, Burgstahler C, Cademartiri F, de Feyter P, George R, Kaufmann P, Kopp AF, Knuuti J, Ropers D, Schuijf J, Tops LF, Bax JJ (2008) Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a writing group deployed by the working group nuclear cardiology and cardiac CT of the European society of cardiology and the european council of nuclear cardiology. Eur Heart J 29(4):531–556PubMedCrossRef
2.
go back to reference Pelliccia F, Pasceri V, Evangelista A, Pergolini A, Barilla F, Viceconte N, Tanzilli G, Schiariti M, Greco C, Gaudio C (2012) Diagnostic accuracy of 320-row computed tomography as compared with invasive coronary angiography in unselected, consecutive patients with suspected coronary artery disease. Int J Cardiovasc Imaging. doi:10.1007/s10554-012-0095-4 Pelliccia F, Pasceri V, Evangelista A, Pergolini A, Barilla F, Viceconte N, Tanzilli G, Schiariti M, Greco C, Gaudio C (2012) Diagnostic accuracy of 320-row computed tomography as compared with invasive coronary angiography in unselected, consecutive patients with suspected coronary artery disease. Int J Cardiovasc Imaging. doi:10.​1007/​s10554-012-0095-4
3.
go back to reference Lee JH, Chun EJ, Choi SI, Vembar M, Lim C, Park KH, Choi DJ (2011) Prospective versus retrospective ECG-gated 64-detector coronary CT angiography for evaluation of coronary artery bypass graft patency: comparison of image quality, radiation dose and diagnostic accuracy. Int J Cardiovasc Imaging 27(5):657–667PubMedCrossRef Lee JH, Chun EJ, Choi SI, Vembar M, Lim C, Park KH, Choi DJ (2011) Prospective versus retrospective ECG-gated 64-detector coronary CT angiography for evaluation of coronary artery bypass graft patency: comparison of image quality, radiation dose and diagnostic accuracy. Int J Cardiovasc Imaging 27(5):657–667PubMedCrossRef
4.
go back to reference Lim S, Choi HJ, Shin H, Khang AR, Kang SM, Yoon JW, Choi SH, Jeong IK, Cho SI, Park KS, Jang HC (2012) Subclinical atherosclerosis in a community-based elderly cohort: the Korean longitudinal study on health and aging. Int J Cardiol 155(1):126–133PubMedCrossRef Lim S, Choi HJ, Shin H, Khang AR, Kang SM, Yoon JW, Choi SH, Jeong IK, Cho SI, Park KS, Jang HC (2012) Subclinical atherosclerosis in a community-based elderly cohort: the Korean longitudinal study on health and aging. Int J Cardiol 155(1):126–133PubMedCrossRef
5.
go back to reference Ueda H, Harimoto K, Tomoyama S, Tamaru H, Miyawaki M, Mitsusada N, Yasuga Y, Hiraoka H (2011) Association between cardiovascular risk factors and the presence of coronary plaque in a zero or low coronary artery calcium score. Int J Cardiol 147(3):475–477PubMedCrossRef Ueda H, Harimoto K, Tomoyama S, Tamaru H, Miyawaki M, Mitsusada N, Yasuga Y, Hiraoka H (2011) Association between cardiovascular risk factors and the presence of coronary plaque in a zero or low coronary artery calcium score. Int J Cardiol 147(3):475–477PubMedCrossRef
6.
go back to reference Kristanto W, van Ooijen PM, Groen JM, Vliegenthart R, Oudkerk M (2012) Small calcified coronary atherosclerotic plaque simulation model: minimal size and attenuation detectable by 64-MDCT and MicroCT. Int J Cardiovasc Imaging 28(4):843–853PubMedCrossRef Kristanto W, van Ooijen PM, Groen JM, Vliegenthart R, Oudkerk M (2012) Small calcified coronary atherosclerotic plaque simulation model: minimal size and attenuation detectable by 64-MDCT and MicroCT. Int J Cardiovasc Imaging 28(4):843–853PubMedCrossRef
7.
go back to reference Ovrehus KA, Marwan M, Botker HE, Achenbach S, Norgaard BL (2012) Reproducibility of coronary plaque detection and characterization using low radiation dose coronary computed tomographic angiography in patients with intermediate likelihood of coronary artery disease (ReSCAN study). Int J Cardiovasc Imaging 28(4):889–899PubMedCrossRef Ovrehus KA, Marwan M, Botker HE, Achenbach S, Norgaard BL (2012) Reproducibility of coronary plaque detection and characterization using low radiation dose coronary computed tomographic angiography in patients with intermediate likelihood of coronary artery disease (ReSCAN study). Int J Cardiovasc Imaging 28(4):889–899PubMedCrossRef
8.
go back to reference Leber AW, Becker A, Knez A, von Ziegler F, Sirol M, Nikolaou K, Ohnesorge B, Fayad ZA, Becker CR, Reiser M, Steinbeck G, Boekstegers P (2006) Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. J Am Coll Cardiol 47(3):672–677PubMedCrossRef Leber AW, Becker A, Knez A, von Ziegler F, Sirol M, Nikolaou K, Ohnesorge B, Fayad ZA, Becker CR, Reiser M, Steinbeck G, Boekstegers P (2006) Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. J Am Coll Cardiol 47(3):672–677PubMedCrossRef
9.
go back to reference Motoyama S, Sarai M, Harigaya H, Anno H, Inoue K, Hara T, Naruse H, Ishii J, Hishida H, Wong ND, Virmani R, Kondo T, Ozaki Y, Narula J (2009) Computed tomographic angiography characteristics of atherosclerotic plaques subsequently resulting in acute coronary syndrome. J Am Coll Cardiol 54(1):49–57PubMedCrossRef Motoyama S, Sarai M, Harigaya H, Anno H, Inoue K, Hara T, Naruse H, Ishii J, Hishida H, Wong ND, Virmani R, Kondo T, Ozaki Y, Narula J (2009) Computed tomographic angiography characteristics of atherosclerotic plaques subsequently resulting in acute coronary syndrome. J Am Coll Cardiol 54(1):49–57PubMedCrossRef
10.
go back to reference Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY, Taylor C, Dunning A, Earls JP (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol 195(3):649–654PubMedCrossRef Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY, Taylor C, Dunning A, Earls JP (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol 195(3):649–654PubMedCrossRef
11.
go back to reference Gebhard C, Fiechter M, Fuchs TA, Ghadri JR, Herzog BA, Kuhn F, Stehli J, Muller E, Kazakauskaite E, Gaemperli O, Kaufmann PA (2012) Coronary artery calcium scoring: Influence of adaptive statistical iterative reconstruction using 64-MDCT. Int J Cardiol. doi:10.1016/j.ijcard.2012.08.003 Gebhard C, Fiechter M, Fuchs TA, Ghadri JR, Herzog BA, Kuhn F, Stehli J, Muller E, Kazakauskaite E, Gaemperli O, Kaufmann PA (2012) Coronary artery calcium scoring: Influence of adaptive statistical iterative reconstruction using 64-MDCT. Int J Cardiol. doi:10.​1016/​j.​ijcard.​2012.​08.​003
12.
go back to reference Prakash P, Kalra MK, Ackman JB, Digumarthy SR, Hsieh J, Do S, Shepard JA, Gilman MD (2010) Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique. Radiology 256(1):261–269PubMedCrossRef Prakash P, Kalra MK, Ackman JB, Digumarthy SR, Hsieh J, Do S, Shepard JA, Gilman MD (2010) Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique. Radiology 256(1):261–269PubMedCrossRef
13.
go back to reference Marin D, Nelson RC, Schindera ST, Richard S, Youngblood RS, Yoshizumi TT, Samei E (2010) Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm–initial clinical experience. Radiology 254(1):145–153PubMedCrossRef Marin D, Nelson RC, Schindera ST, Richard S, Youngblood RS, Yoshizumi TT, Samei E (2010) Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm–initial clinical experience. Radiology 254(1):145–153PubMedCrossRef
14.
go back to reference Pedrazzini GB, D’Angeli I, Vassalli G, Faletra FF, Klersy C, Pasotti E, Corbacelli C, Moccetti T, Auricchio A (2011) Assessment of coronary stenosis, plaque burden and remodeling by multidetector computed tomography in patients referred for suspected coronary artery disease. J Cardiovasc Med (Hagerstown) 12(2):122–130CrossRef Pedrazzini GB, D’Angeli I, Vassalli G, Faletra FF, Klersy C, Pasotti E, Corbacelli C, Moccetti T, Auricchio A (2011) Assessment of coronary stenosis, plaque burden and remodeling by multidetector computed tomography in patients referred for suspected coronary artery disease. J Cardiovasc Med (Hagerstown) 12(2):122–130CrossRef
15.
go back to reference Husmann L, Schepis T, Scheffel H, Gaemperli O, Leschka S, Valenta I, Koepfli P, Desbiolles L, Stolzmann P, Marincek B, Alkadhi H, Kaufmann PA (2008) Comparison of diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low, intermediate, and high cardiovascular risk. Acad Radiol 15(4):452–461PubMedCrossRef Husmann L, Schepis T, Scheffel H, Gaemperli O, Leschka S, Valenta I, Koepfli P, Desbiolles L, Stolzmann P, Marincek B, Alkadhi H, Kaufmann PA (2008) Comparison of diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low, intermediate, and high cardiovascular risk. Acad Radiol 15(4):452–461PubMedCrossRef
16.
go back to reference Pazhenkottil AP, Husmann L, Buechel RR, Herzog BA, Nkoulou R, Burger IA, Vetterli A, Valenta I, Ghadri JR, von Schulthess P, Kaufmann PA (2010) Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggering. Int J Cardiovasc Imaging 26(5):591–597PubMedCrossRef Pazhenkottil AP, Husmann L, Buechel RR, Herzog BA, Nkoulou R, Burger IA, Vetterli A, Valenta I, Ghadri JR, von Schulthess P, Kaufmann PA (2010) Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggering. Int J Cardiovasc Imaging 26(5):591–597PubMedCrossRef
17.
go back to reference Tatsugami F, Husmann L, Herzog BA, Burkhard N, Valenta I, Gaemperli O, Kaufmann PA (2009) Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggering. AJR Am J Roentgenol 192(3):635–638PubMedCrossRef Tatsugami F, Husmann L, Herzog BA, Burkhard N, Valenta I, Gaemperli O, Kaufmann PA (2009) Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggering. AJR Am J Roentgenol 192(3):635–638PubMedCrossRef
18.
go back to reference Ghadri JR, Kuest SM, Goetti R, Fiechter M, Pazhenkottil AP, Nkoulou RN, Kuhn FP, Pietsch C, von Schulthess P, Gaemperli O, Templin C, Kaufmann PA (2012) Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition. Int J Cardiovasc Imaging 28:1217–1225 Ghadri JR, Kuest SM, Goetti R, Fiechter M, Pazhenkottil AP, Nkoulou RN, Kuhn FP, Pietsch C, von Schulthess P, Gaemperli O, Templin C, Kaufmann PA (2012) Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition. Int J Cardiovasc Imaging 28:1217–1225
19.
go back to reference Akutagawa O, Kijima Y, Kume K, Sakai T, Okura A, Ide K, Iwasaki S, Hata T (2011) Feasibility and limitation of coronary plaque volumetry by contrast-enhanced 64-row multi-detector computed tomography. Int J Cardiol 150(1):118–120PubMedCrossRef Akutagawa O, Kijima Y, Kume K, Sakai T, Okura A, Ide K, Iwasaki S, Hata T (2011) Feasibility and limitation of coronary plaque volumetry by contrast-enhanced 64-row multi-detector computed tomography. Int J Cardiol 150(1):118–120PubMedCrossRef
20.
go back to reference Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY, Taylor C, Dunning A, Earls JP (2010) Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. AJR Am J Roentgenol 195(3):655–660PubMedCrossRef Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY, Taylor C, Dunning A, Earls JP (2010) Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. AJR Am J Roentgenol 195(3):655–660PubMedCrossRef
21.
go back to reference Scheffel H, Stolzmann P, Schlett CL, Engel LC, Major GP, Karolyi M, Do S, Maurovich-Horvat P, Hoffmann U (2012) Coronary artery plaques: Cardiac CT with model-based and adaptive-statistical iterative reconstruction technique. Eur J Radiol 81(3):e363–e369PubMedCrossRef Scheffel H, Stolzmann P, Schlett CL, Engel LC, Major GP, Karolyi M, Do S, Maurovich-Horvat P, Hoffmann U (2012) Coronary artery plaques: Cardiac CT with model-based and adaptive-statistical iterative reconstruction technique. Eur J Radiol 81(3):e363–e369PubMedCrossRef
22.
go back to reference Fiechter M, Frey K, Fugmann T, Kaufmann PA, Neri D (2011) Comparative in vivo analysis of the atherosclerotic plaque targeting properties of eight human monoclonal antibodies. Atherosclerosis 214(2):325–330PubMedCrossRef Fiechter M, Frey K, Fugmann T, Kaufmann PA, Neri D (2011) Comparative in vivo analysis of the atherosclerotic plaque targeting properties of eight human monoclonal antibodies. Atherosclerosis 214(2):325–330PubMedCrossRef
23.
go back to reference Herzog BA, Husmann L, Buechel RR, Pazhenkottil AP, Burger IA, Valenta I, Altorfer U, Wolfrum M, Nkoulou RN, Ghadri JR, Wyss CA, Kaufmann PA (2011) Rapid cardiac hybrid imaging with minimized radiation dose for accurate non-invasive assessment of ischemic coronary artery disease. Int J Cardiol 153(1):10–13PubMedCrossRef Herzog BA, Husmann L, Buechel RR, Pazhenkottil AP, Burger IA, Valenta I, Altorfer U, Wolfrum M, Nkoulou RN, Ghadri JR, Wyss CA, Kaufmann PA (2011) Rapid cardiac hybrid imaging with minimized radiation dose for accurate non-invasive assessment of ischemic coronary artery disease. Int J Cardiol 153(1):10–13PubMedCrossRef
Metadata
Title
CT coronary angiography: impact of adapted statistical iterative reconstruction (ASIR) on coronary stenosis and plaque composition analysis
Authors
Tobias A. Fuchs
Michael Fiechter
Cathérine Gebhard
Julia Stehli
Jelena R. Ghadri
Egle Kazakauskaite
Bernhard A. Herzog
Lars Husmann
Oliver Gaemperli
Philipp A. Kaufmann
Publication date
01-03-2013
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 3/2013
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0134-1

Other articles of this Issue 3/2013

The International Journal of Cardiovascular Imaging 3/2013 Go to the issue