Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 4/2012

01-04-2012 | Original Paper

Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation

Authors: Byeong-Keuk Kim, Jung-Sun Kim, Changmyung Oh, Young-Guk Ko, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong

Published in: The International Journal of Cardiovascular Imaging | Issue 4/2012

Login to get access

Abstract

There have been little data regarding major determinants for the uncovered stent struts after drug-eluting stent (DES) implantation on optical coherence tomography (OCT). We investigated the major determinants of incomplete neointimal coverage of DES struts on OCT after implantation in a large cohort of patients. A total of 261 patients with 279 lesions who were treated with various DESs were selected from the OCT registry database. The lesions were divided into two groups based on the ratio of uncovered struts to total struts in all OCT cross-sections; an uncovered group (highest quartile with % uncovered struts ≥5.4%, n = 70), and covered group (the remaining lower quartiles with % uncovered struts <5.4%, n = 209). The uncovered group was more likely to have complex lesions, smaller reference vessel and stent diameter, and longer stent, more use of sirolimus-eluting stents, and less use of zotarolimus-eluting stents compared with the covered group. Of these variables, the most significant determinant of uncovered stent struts was DES type (odds ratio [OR] = 2.75, 95% confidence interval [CI] = 1.94–3.89, P < 0.001). The use of sirolimus-eluting stents (OR = 2.44, 95% CI, 1.15–5.47, P = 0.023) and zotarolimus-eluting stents (OR = 0.02, 95% CI = 0.01–0.25, P = 0.002) were the only significant risk and protective factors for uncovered stent struts, respectively. This study demonstrated that DES type might be associated with the most important determinants of uncovered struts compared to any other clinical or angiographic factor.
Literature
1.
go back to reference Farb A, Burke AP, Kolodgie FD, Virmani R (2003) Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 108:1701–1706PubMedCrossRef Farb A, Burke AP, Kolodgie FD, Virmani R (2003) Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 108:1701–1706PubMedCrossRef
2.
go back to reference Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441PubMedCrossRef Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441PubMedCrossRef
3.
go back to reference Finn AV, Nakazawa G, Joner M, Kolodgie FD, Mont EK, Gold HK, Virmani R (2007) Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler Thromb Vasc Biol 27:1500–1510PubMedCrossRef Finn AV, Nakazawa G, Joner M, Kolodgie FD, Mont EK, Gold HK, Virmani R (2007) Vascular responses to drug eluting stents: importance of delayed healing. Arterioscler Thromb Vasc Biol 27:1500–1510PubMedCrossRef
4.
go back to reference Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, Ohba T, Mizuno K (2007) Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 99:1033–1038PubMedCrossRef Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, Ohba T, Mizuno K (2007) Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 99:1033–1038PubMedCrossRef
5.
go back to reference Guagliumi G, Sirbu V (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72:237–247PubMedCrossRef Guagliumi G, Sirbu V (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72:237–247PubMedCrossRef
6.
go back to reference Takano M, Yamamoto M, Inami S, Murakami D, Seimiya K, Ohba T, Seino Y, Mizuno K (2008) Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist? J Am Coll Cardiol 51:968–969PubMedCrossRef Takano M, Yamamoto M, Inami S, Murakami D, Seimiya K, Ohba T, Seino Y, Mizuno K (2008) Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist? J Am Coll Cardiol 51:968–969PubMedCrossRef
7.
go back to reference Kim JS, Jang IK, Kim JS, Kim TH, Takano M, Kume T, Hur NW, Ko YG, Choi D, Hong MK, Jang Y (2009) Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents. Heart 95:1907–1912PubMedCrossRef Kim JS, Jang IK, Kim JS, Kim TH, Takano M, Kume T, Hur NW, Ko YG, Choi D, Hong MK, Jang Y (2009) Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents. Heart 95:1907–1912PubMedCrossRef
8.
go back to reference Ishigami K, Uemura S, Morikawa Y, Soeda T, Okayama S, Nishida T, Takemoto Y, Onoue K, Somekawa S, Takeda Y, Kawata H, Horii M, Saito Y (2009) Long-term follow-up of neointimal coverage of sirolimus-eluting stents–evaluation with optical coherence tomography. Circ J 73:2300–2307PubMedCrossRef Ishigami K, Uemura S, Morikawa Y, Soeda T, Okayama S, Nishida T, Takemoto Y, Onoue K, Somekawa S, Takeda Y, Kawata H, Horii M, Saito Y (2009) Long-term follow-up of neointimal coverage of sirolimus-eluting stents–evaluation with optical coherence tomography. Circ J 73:2300–2307PubMedCrossRef
9.
go back to reference Kim JS, Fan C, Choi D, Jang IK, Lee JM, Kim TH, Park SM, Paik SI, Ko YG, Hong MK, Jang Y, Chung N (2011) Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study. Int J Cardiol 146:341–346PubMedCrossRef Kim JS, Fan C, Choi D, Jang IK, Lee JM, Kim TH, Park SM, Paik SI, Ko YG, Hong MK, Jang Y, Chung N (2011) Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study. Int J Cardiol 146:341–346PubMedCrossRef
10.
go back to reference Chen BX, Ma FY, Luo W, Ruan JH, Xie WL, Zhao XZ, Sun SH, Guo XM, Wang F, Tian T, Chu XW (2008) Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography. Heart 94:566–570PubMedCrossRef Chen BX, Ma FY, Luo W, Ruan JH, Xie WL, Zhao XZ, Sun SH, Guo XM, Wang F, Tian T, Chu XW (2008) Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography. Heart 94:566–570PubMedCrossRef
11.
go back to reference Kim U, Kim JS, Kim JS, Lee JM, Son JW, Kim J, Ko YG, Choi D, Jang Y (2010) The initial extent of malapposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography. Yonsei Med J 51:332–338PubMedCrossRef Kim U, Kim JS, Kim JS, Lee JM, Son JW, Kim J, Ko YG, Choi D, Jang Y (2010) The initial extent of malapposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography. Yonsei Med J 51:332–338PubMedCrossRef
12.
go back to reference Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang IK, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW (for the expert’s OCT review document) (2010) Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31:401–415 Prati F, Regar E, Mintz GS, Arbustini E, Di Mario C, Jang IK, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW (for the expert’s OCT review document) (2010) Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31:401–415
13.
go back to reference Barlis P, Dimopoulos K, Tanigawa J, Dzielicka E, Ferrante G, Del Furia F, Di Mario C (2010) Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage. Int J Cardiol 28:151–156CrossRef Barlis P, Dimopoulos K, Tanigawa J, Dzielicka E, Ferrante G, Del Furia F, Di Mario C (2010) Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage. Int J Cardiol 28:151–156CrossRef
14.
go back to reference Kim JS, Hong MK, Fan C, Kim TH, Shim JM, Park SM, Ko YG, Choi D, Jang Y (2010) Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study. Am Heart J 159:278–283PubMedCrossRef Kim JS, Hong MK, Fan C, Kim TH, Shim JM, Park SM, Ko YG, Choi D, Jang Y (2010) Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study. Am Heart J 159:278–283PubMedCrossRef
15.
go back to reference Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97:1713–1717PubMedCrossRef Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97:1713–1717PubMedCrossRef
16.
go back to reference Kubo T, Imanishi T, Kitabata H, Kuroi A, Ueno S, Yamano T, Tanimoto T, Matsuo Y, Masho T, Takarada S, Tanaka A, Nakamura N, Mizukoshi M, Tomobuchi Y, Akasaka T (2008) Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study. JACC Cardiovasc Imaging 1:475–484PubMedCrossRef Kubo T, Imanishi T, Kitabata H, Kuroi A, Ueno S, Yamano T, Tanimoto T, Matsuo Y, Masho T, Takarada S, Tanaka A, Nakamura N, Mizukoshi M, Tomobuchi Y, Akasaka T (2008) Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study. JACC Cardiovasc Imaging 1:475–484PubMedCrossRef
17.
go back to reference Gonzalo N, Barlis P, Serruys PW, Garcia-Garcia HM, Onuma Y, Ligthart J, Regar E (2009) Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: insights from optical coherence tomography. JACC Cardiovasc Interv 2:445–452PubMedCrossRef Gonzalo N, Barlis P, Serruys PW, Garcia-Garcia HM, Onuma Y, Ligthart J, Regar E (2009) Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: insights from optical coherence tomography. JACC Cardiovasc Interv 2:445–452PubMedCrossRef
18.
go back to reference Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A (2005) Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 293:2126–2130PubMedCrossRef Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A (2005) Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 293:2126–2130PubMedCrossRef
19.
go back to reference Daemen J, Wenaweser P, Tsuchida K, Abrecht L, Vaina S, Morger C, Kukreja N, Jüni P, Sianos G, Hellige G, van Domburg RT, Hess OM, Boersma E, Meier B, Windecker S, Serruys PW (2007) Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet 369:667–678PubMedCrossRef Daemen J, Wenaweser P, Tsuchida K, Abrecht L, Vaina S, Morger C, Kukreja N, Jüni P, Sianos G, Hellige G, van Domburg RT, Hess OM, Boersma E, Meier B, Windecker S, Serruys PW (2007) Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet 369:667–678PubMedCrossRef
20.
go back to reference Hoffmann R, Klinker H, Adamu U, Kelm M, Blindt R (2009) The risk of definitive stent thrombosis is increased after “off-label” stent implantation irrespective of drug-eluting stent or bare-metal stent use. Clin Res Cardiol 98:549–554PubMedCrossRef Hoffmann R, Klinker H, Adamu U, Kelm M, Blindt R (2009) The risk of definitive stent thrombosis is increased after “off-label” stent implantation irrespective of drug-eluting stent or bare-metal stent use. Clin Res Cardiol 98:549–554PubMedCrossRef
21.
go back to reference Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R (2006) Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48:193–202PubMedCrossRef Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R (2006) Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48:193–202PubMedCrossRef
22.
go back to reference Kim WH, Lee BK, Lee S, Shim JM, Kim JS, Kim BK, Ko YG, Choi D, Jang Y, Hong MK (2010) Serial changes of minimal stent malapposition not detected by intravascular ultrasound: follow-up optical coherence tomography study. Clin Res Cardiol 99:639–644PubMedCrossRef Kim WH, Lee BK, Lee S, Shim JM, Kim JS, Kim BK, Ko YG, Choi D, Jang Y, Hong MK (2010) Serial changes of minimal stent malapposition not detected by intravascular ultrasound: follow-up optical coherence tomography study. Clin Res Cardiol 99:639–644PubMedCrossRef
23.
go back to reference Levin AD, Vukmirovic N, Hwang CW, Edelman ER (2004) Specific binding to intracellular proteins determines arterial transport properties for rapamycin and paclitaxel. Proc Natl Acad Sci U S A 101:9463–9467PubMedCrossRef Levin AD, Vukmirovic N, Hwang CW, Edelman ER (2004) Specific binding to intracellular proteins determines arterial transport properties for rapamycin and paclitaxel. Proc Natl Acad Sci U S A 101:9463–9467PubMedCrossRef
24.
go back to reference Hwang CW, Levin AD, Jonas M, Li PH, Edelman ER (2005) Thrombosis modulates arterial drug distribution for drug-eluting stents. Circulation 111:1619–1626PubMedCrossRef Hwang CW, Levin AD, Jonas M, Li PH, Edelman ER (2005) Thrombosis modulates arterial drug distribution for drug-eluting stents. Circulation 111:1619–1626PubMedCrossRef
25.
go back to reference Varma S, Lal BK, Zheng R, Breslin JW, Saito S, Pappas PJ, Hobson RW 2nd, Durán WN (2005) Hyperglycemia alters PI3k and Akt signaling and leads to endothelial cell proliferative dysfunction. Am J Physiol Heart Circ Physiol 289:H1744–H1751PubMedCrossRef Varma S, Lal BK, Zheng R, Breslin JW, Saito S, Pappas PJ, Hobson RW 2nd, Durán WN (2005) Hyperglycemia alters PI3k and Akt signaling and leads to endothelial cell proliferative dysfunction. Am J Physiol Heart Circ Physiol 289:H1744–H1751PubMedCrossRef
26.
go back to reference Kubo T, Imanishi T, Takarada S, Kuroi A, Ueno S, Yamano T, Tanimoto T, Matsuo Y, Masho T, Kitabata H, Tsuda K, Tomobuchi Y, Akasaka T (2007) Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy. J Am Coll Cardiol 50:933–939PubMedCrossRef Kubo T, Imanishi T, Takarada S, Kuroi A, Ueno S, Yamano T, Tanimoto T, Matsuo Y, Masho T, Kitabata H, Tsuda K, Tomobuchi Y, Akasaka T (2007) Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy. J Am Coll Cardiol 50:933–939PubMedCrossRef
27.
go back to reference Klugherz BD, Llanos G, Lieuallen W, Kopia GA, Papandreou G, Narayan P, Sasseen B, Adelman SJ, Falotico R, Wilensky RL (2002) Twenty-eight-day efficacy and phamacokinetics of the sirolimus-eluting stent. Coron Artery Dis 13:183–188PubMedCrossRef Klugherz BD, Llanos G, Lieuallen W, Kopia GA, Papandreou G, Narayan P, Sasseen B, Adelman SJ, Falotico R, Wilensky RL (2002) Twenty-eight-day efficacy and phamacokinetics of the sirolimus-eluting stent. Coron Artery Dis 13:183–188PubMedCrossRef
Metadata
Title
Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation
Authors
Byeong-Keuk Kim
Jung-Sun Kim
Changmyung Oh
Young-Guk Ko
Donghoon Choi
Yangsoo Jang
Myeong-Ki Hong
Publication date
01-04-2012
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 4/2012
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9896-0

Other articles of this Issue 4/2012

The International Journal of Cardiovascular Imaging 4/2012 Go to the issue