Skip to main content
Top
Published in: Clinical Research in Cardiology 10/2010

01-10-2010 | Original Paper

Serial changes of minimal stent malapposition not detected by intravascular ultrasound: follow-up optical coherence tomography study

Authors: Won Ho Kim, Byoung Kwon Lee, Sahng Lee, Jae-Min Shim, Jung-Sun Kim, Byoung-Keuk Kim, Young-Guk Ko, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong

Published in: Clinical Research in Cardiology | Issue 10/2010

Login to get access

Abstract

Morphologic changes of small-sized post-stent malapposition have not been sufficiently evaluated. We investigated serial changes of minimal post-stent malapposition with a follow-up optical coherence tomography (OCT) study. Post-stent OCT and intravascular ultrasound (IVUS) and follow-up OCT were performed in 26 patients with minimal post-stent malapposition. Serial changes of number and percent of malapposition struts, and mean extra-stent malapposition area were measured in OCT analysis. Zotarolimus-eluting stent (ZES), sirolimus-eluting stent (SES), and paclitaxel-eluting stent (PES) were deployed in 17, 7 and 2 patients, respectively. Mean durations of the follow-up OCT study were 5.7 ± 3.0 months. The minimal post-stent malapposition cannot be detected by the IVUS, but be visualized with an OCT examination. According to different drug-eluting stents, malapposed stent struts were defined as the struts with detachment from the vessel wall ≥160 μm for SES, ≥130 μm for PES, and ≥110 μm for ZES. The percent of malapposition struts significantly decreased from 12.2 ± 11.0% post-stent to 1.0 ± 2.2% follow-up (P < 0.001). There was a significant decrease in the mean extra-stent malapposition area from 0.35 ± 0.16 mm2 post-stent to 0.04 ± 0.11 mm2 follow-up (P < 0.001). Complete disappearance of stent malapposition was also observed in 22 (85%) patients. In conclusion, minimal stent malapposition which is not detectable by IVUS may disappear or decrease in follow-up OCT evaluation.
Literature
1.
go back to reference Dilcher CE, Chan RC, Pregowski J, Kalinczuk L, Mintz GS, Kotani J, Kruk M, Shah VM, Canos DA, Weissman NJ, Waksman R (2002) Dose volume histogram assessment of late stent malapposition after intravascular brachytherapy. Cardiovasc Radiat Med 3:190–192CrossRefPubMed Dilcher CE, Chan RC, Pregowski J, Kalinczuk L, Mintz GS, Kotani J, Kruk M, Shah VM, Canos DA, Weissman NJ, Waksman R (2002) Dose volume histogram assessment of late stent malapposition after intravascular brachytherapy. Cardiovasc Radiat Med 3:190–192CrossRefPubMed
2.
go back to reference Hong MK, Mintz GS, Lee CW, Kim YH, Lee SW, Song JM, Han KH, Kang DH, Song JK, Kim JJ, Park SW, Park SJ (2004) Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation 109:881–886CrossRefPubMed Hong MK, Mintz GS, Lee CW, Kim YH, Lee SW, Song JM, Han KH, Kang DH, Song JK, Kim JJ, Park SW, Park SJ (2004) Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation 109:881–886CrossRefPubMed
3.
go back to reference Hassan AK, Bergheanu SC, Stijnen T, van der Hoeven BL, Snoep JD, Plevier JW, Schalij MJ, Jukema JW (2010) Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J (in press) Hassan AK, Bergheanu SC, Stijnen T, van der Hoeven BL, Snoep JD, Plevier JW, Schalij MJ, Jukema JW (2010) Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J (in press)
4.
go back to reference Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Paredes OL, Hirata K, Yokoyama M (2007) Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J 28:918–919CrossRef Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Paredes OL, Hirata K, Yokoyama M (2007) Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J 28:918–919CrossRef
5.
go back to reference Tanigawa J, Barlis P, Di Mario C (2007) Intravascular optical coherence tomography: optimization of image acquisition and quantitative assessment of stent strut apposition. Eurointervention 3:128–136PubMed Tanigawa J, Barlis P, Di Mario C (2007) Intravascular optical coherence tomography: optimization of image acquisition and quantitative assessment of stent strut apposition. Eurointervention 3:128–136PubMed
6.
go back to reference Guagliumi G, Sirbu V (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72:237–247CrossRefPubMed Guagliumi G, Sirbu V (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72:237–247CrossRefPubMed
7.
go back to reference Bouma BE, Tearney GJ, Yabushita H, Shishkov M, Kauffman CR, DeJoseph Gauthier D, MacNeill BD, Houser SL, Aretz HT, Halpern EF, Jang IK (2003) Evaluation of intracoronary stenting by intravascular optical coherence tomography. Heart 89:317–320CrossRefPubMed Bouma BE, Tearney GJ, Yabushita H, Shishkov M, Kauffman CR, DeJoseph Gauthier D, MacNeill BD, Houser SL, Aretz HT, Halpern EF, Jang IK (2003) Evaluation of intracoronary stenting by intravascular optical coherence tomography. Heart 89:317–320CrossRefPubMed
8.
go back to reference Kim JS, Jang IK, Kim JS, Kim TH, Takano M, Kume T, Hur NW, Ko YG, Choi D, Hong MK, Jang Y (2009) Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents. Heart 95:1907–1912CrossRefPubMed Kim JS, Jang IK, Kim JS, Kim TH, Takano M, Kume T, Hur NW, Ko YG, Choi D, Hong MK, Jang Y (2009) Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents. Heart 95:1907–1912CrossRefPubMed
9.
go back to reference Arnold JR, van Gaal WJ, Banning AP (2006) Thrombotic occlusion of a drug-eluting stent-is IVUS mandatory. J Invasive Cardiol 18:e238–e240PubMed Arnold JR, van Gaal WJ, Banning AP (2006) Thrombotic occlusion of a drug-eluting stent-is IVUS mandatory. J Invasive Cardiol 18:e238–e240PubMed
10.
go back to reference Shah VM, Mintz GS, Apple S, Weissman NJ (2002) Background incidence of late malapposition after bare-metal stent implantation. Circulation 106:1753–1755CrossRefPubMed Shah VM, Mintz GS, Apple S, Weissman NJ (2002) Background incidence of late malapposition after bare-metal stent implantation. Circulation 106:1753–1755CrossRefPubMed
11.
go back to reference Hong MK, Mintz GS, Lee CW, Park DW, Park KM, Lee BK, Kim YH, Song JM, Han KH, Kang DH, Cheong SS, Song JK, Kim JJ, Park SW, Park SJ (2006) Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up. Circulation 113:414–419CrossRefPubMed Hong MK, Mintz GS, Lee CW, Park DW, Park KM, Lee BK, Kim YH, Song JM, Han KH, Kang DH, Cheong SS, Song JK, Kim JJ, Park SW, Park SJ (2006) Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up. Circulation 113:414–419CrossRefPubMed
12.
go back to reference Tanabe K, Serruys PW, Degertekin M, Grube E, Guagliumi G, Urbaszek W, Bonnier J, Lablanche JM, Siminiak T, Nordrehaug J, Figulla H, Drzewiecki J, Banning A, Hauptmann K, Dudek D, Bruining N, Hamers R, Hoye A, Ligthart JM, Disco C, Koglin J, Russell ME, Colombo A, TAXUS II Study Group (2005) Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: insights from the randomized TAXUS II trial. Circulation 111:900–905CrossRefPubMed Tanabe K, Serruys PW, Degertekin M, Grube E, Guagliumi G, Urbaszek W, Bonnier J, Lablanche JM, Siminiak T, Nordrehaug J, Figulla H, Drzewiecki J, Banning A, Hauptmann K, Dudek D, Bruining N, Hamers R, Hoye A, Ligthart JM, Disco C, Koglin J, Russell ME, Colombo A, TAXUS II Study Group (2005) Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: insights from the randomized TAXUS II trial. Circulation 111:900–905CrossRefPubMed
13.
go back to reference Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T, Mihalcsik L, Tespili M, Valsecchi O, Kolodgie FD (2004) Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 109:701–705CrossRefPubMed Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T, Mihalcsik L, Tespili M, Valsecchi O, Kolodgie FD (2004) Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 109:701–705CrossRefPubMed
14.
go back to reference Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R (2006) Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48:193–202CrossRefPubMed Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R (2006) Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48:193–202CrossRefPubMed
15.
go back to reference Lüscher TF, Steffel J, Eberli FR, Joner M, Nakazawa G, Tanner FC, Virmani R (2007) Drug-eluting stent and coronary thrombosis: biological mechanisms and clinical implications. Circulation 115:1051–1058CrossRefPubMed Lüscher TF, Steffel J, Eberli FR, Joner M, Nakazawa G, Tanner FC, Virmani R (2007) Drug-eluting stent and coronary thrombosis: biological mechanisms and clinical implications. Circulation 115:1051–1058CrossRefPubMed
16.
go back to reference Capodanno D, Capranzano P, Bucalo R, Sanfilippo A, Ruperto C, Caggegi A, Ussia G, Galassi AR, Tamburino C (2009) A novel approach to define risk of stent thrombosis after percutaneous coronary intervention with drug-eluting stents: the DERIVATION score. Clin Res Cardiol 98:240–248CrossRefPubMed Capodanno D, Capranzano P, Bucalo R, Sanfilippo A, Ruperto C, Caggegi A, Ussia G, Galassi AR, Tamburino C (2009) A novel approach to define risk of stent thrombosis after percutaneous coronary intervention with drug-eluting stents: the DERIVATION score. Clin Res Cardiol 98:240–248CrossRefPubMed
17.
go back to reference Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441CrossRefPubMed Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441CrossRefPubMed
18.
go back to reference Cook S, Wenaweser P, Togni M, Billinger M, Morger C, Seiler C, Vogel R, Hess O, Meier B, Windecker S (2007) Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 115:2426–2434CrossRefPubMed Cook S, Wenaweser P, Togni M, Billinger M, Morger C, Seiler C, Vogel R, Hess O, Meier B, Windecker S (2007) Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 115:2426–2434CrossRefPubMed
19.
go back to reference Hoffmann R, Klinker H, Adamu U, Kelm M, Blindt R (2009) The risk of definitive stent thrombosis is increased after ‘‘off-label’’ stent implantation irrespective of drug-eluting stent or bare-metal stent use. Clin Res Cardiol 98:549–554CrossRefPubMed Hoffmann R, Klinker H, Adamu U, Kelm M, Blindt R (2009) The risk of definitive stent thrombosis is increased after ‘‘off-label’’ stent implantation irrespective of drug-eluting stent or bare-metal stent use. Clin Res Cardiol 98:549–554CrossRefPubMed
20.
go back to reference Jang IK, Bouma BE, Kang DH, Park SJ, Park SW, Seong KB, Choi KB, Shishkov M, Schlendorf K, Pomerantsev E, Houser SL, Aretz T, Tearney GJ (2002) Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. J Am Coll Cardiol 39:604–609CrossRefPubMed Jang IK, Bouma BE, Kang DH, Park SJ, Park SW, Seong KB, Choi KB, Shishkov M, Schlendorf K, Pomerantsev E, Houser SL, Aretz T, Tearney GJ (2002) Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. J Am Coll Cardiol 39:604–609CrossRefPubMed
21.
go back to reference Kume T, Akasaka T, Kawamoto T, Watanabe N, Toyota E, Sukmawan R, Sadahira Y, Yoshida K (2005) Visualization of neointima formation by optical coherence tomography. Int Heart J 46:1133–1136CrossRefPubMed Kume T, Akasaka T, Kawamoto T, Watanabe N, Toyota E, Sukmawan R, Sadahira Y, Yoshida K (2005) Visualization of neointima formation by optical coherence tomography. Int Heart J 46:1133–1136CrossRefPubMed
22.
go back to reference Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C (2010) The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol (in press) Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C (2010) The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol (in press)
Metadata
Title
Serial changes of minimal stent malapposition not detected by intravascular ultrasound: follow-up optical coherence tomography study
Authors
Won Ho Kim
Byoung Kwon Lee
Sahng Lee
Jae-Min Shim
Jung-Sun Kim
Byoung-Keuk Kim
Young-Guk Ko
Donghoon Choi
Yangsoo Jang
Myeong-Ki Hong
Publication date
01-10-2010
Publisher
Springer-Verlag
Published in
Clinical Research in Cardiology / Issue 10/2010
Print ISSN: 1861-0684
Electronic ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-010-0163-5

Other articles of this Issue 10/2010

Clinical Research in Cardiology 10/2010 Go to the issue