This study aimed to compare the diagnostic effectiveness of computer-aided detection (CAD) software (OnGuard™ 5.2) in combination with hardware-based bone suppression (dual-energy subtraction radiography (DESR)), software-based bone suppression (SoftView™, version 2.4), and standard posteroanterior images with no bone suppression. A retrospective pilot study compared the diagnostic performance of two commercially available methods of bone suppression when used with commercially available CAD software. Chest images from 27 patients with computed tomography (CT) and pathology-proven malignant pulmonary nodules (8–34 mm) and 25 CT-negative patient controls were used for analysis. The Friedman, McNemar, and chi-square tests were used to compare diagnostic performance and the kappa statistic was used to evaluate method agreement. The average number of regions of interest and false-positives per image identified by CAD were not found to be significantly different regardless of the bone suppression methods evaluated. Similarly, the sensitivity, specificity, and test efficiency were not found to be significantly different. Agreement between the methods was between poor and excellent. The accuracy of CAD (OnGuard™, version 5.2) is not statistically different with either DESR or SoftView™ (version 2.4) bone suppression technology in digital chest images for pulmonary nodule identification. Low values for sensitivity (<80 %) and specificity (<50 %) may limit their utility for clinical radiology.
Literature
1.
go back to reference Kobayashi T, Xu XW, MacMahon H, Metz CE, Doi K: Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs. Radiology. 199(3):843–848, 1996PubMed Kobayashi T, Xu XW, MacMahon H, Metz CE, Doi K: Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs. Radiology. 199(3):843–848, 1996PubMed
2.
go back to reference Bley TA, Baumann T, Saueressig U, Pache G, Treier M, Schaefer O, et al: Comparison of radiologist and CAD performance in the detection of CT-confirmed subtle pulmonary nodules on digital chest radiographs. Invest Radiol. 43(6):343–348, 2008PubMedCrossRef Bley TA, Baumann T, Saueressig U, Pache G, Treier M, Schaefer O, et al: Comparison of radiologist and CAD performance in the detection of CT-confirmed subtle pulmonary nodules on digital chest radiographs. Invest Radiol. 43(6):343–348, 2008PubMedCrossRef
3.
go back to reference Kasai S, Li F, Shiraishi J, Doi K: Usefulness of computer-aided diagnosis schemes for vertebral fractures and lung nodules on chest radiographs. AJR Am J Roentgenol. 191(1):260–265, 2008PubMedCrossRef Kasai S, Li F, Shiraishi J, Doi K: Usefulness of computer-aided diagnosis schemes for vertebral fractures and lung nodules on chest radiographs. AJR Am J Roentgenol. 191(1):260–265, 2008PubMedCrossRef
4.
go back to reference Meziane M, Obuchowski NA, Lababede O, Lieber ML, Philips M, Mazzone P: A comparison of follow-up recommendations by chest radiologists, general radiologists, and pulmonologists using computer-aided detection to assess radiographs for actionable pulmonary nodules. AJR Am J Roentgenol. 196(5):W542–W549, 2011PubMedCrossRef Meziane M, Obuchowski NA, Lababede O, Lieber ML, Philips M, Mazzone P: A comparison of follow-up recommendations by chest radiologists, general radiologists, and pulmonologists using computer-aided detection to assess radiographs for actionable pulmonary nodules. AJR Am J Roentgenol. 196(5):W542–W549, 2011PubMedCrossRef
5.
go back to reference De Boo DW, Uffmann M, Weber M, Bipat S, Boorsma EF, Scheerder MJ, et al: Computer-aided detection of small pulmonary nodules in chest radiographs: an observer study. Acad Radiol 18(12):1507–1514, 2011. LID–10.1016/j.aPubMedCrossRef De Boo DW, Uffmann M, Weber M, Bipat S, Boorsma EF, Scheerder MJ, et al: Computer-aided detection of small pulmonary nodules in chest radiographs: an observer study. Acad Radiol 18(12):1507–1514, 2011. LID–10.1016/j.aPubMedCrossRef
6.
go back to reference Eadie LH, Taylor P, Gibson AP: A systematic review of computer-assisted diagnosis in diagnostic cancer imaging. Eur J Radiol. 81(1):e70–e76, 2012PubMedCrossRef Eadie LH, Taylor P, Gibson AP: A systematic review of computer-assisted diagnosis in diagnostic cancer imaging. Eur J Radiol. 81(1):e70–e76, 2012PubMedCrossRef
7.
go back to reference Shah PK, Austin JH, White CS, Patel P, Haramati LB, Pearson GD, et al: Missed non-small cell lung cancer: radiographic findings of potentially resectable lesions evident only in retrospect. Radiology. 226(1):235–241, 2003PubMedCrossRef Shah PK, Austin JH, White CS, Patel P, Haramati LB, Pearson GD, et al: Missed non-small cell lung cancer: radiographic findings of potentially resectable lesions evident only in retrospect. Radiology. 226(1):235–241, 2003PubMedCrossRef
8.
go back to reference Monnier-Cholley L, Carrat F, Cholley BP, Tubiana JM, Arrive L: Detection of lung cancer on radiographs: receiver operating characteristic analyses of radiologists', pulmonologists', and anesthesiologists' performance. Radiology. 233(3):799–805, 2004PubMedCrossRef Monnier-Cholley L, Carrat F, Cholley BP, Tubiana JM, Arrive L: Detection of lung cancer on radiographs: receiver operating characteristic analyses of radiologists', pulmonologists', and anesthesiologists' performance. Radiology. 233(3):799–805, 2004PubMedCrossRef
9.
go back to reference Oda S, Awai K, Funama Y, Utsunomiya D, Yanaga Y, Kawanaka K, et al: Effects of dual-energy subtraction chest radiography on detection of small pulmonary nodules with varying attenuation: receiver operating characteristic analysis using a phantom study. Jpn J Radiol. 28(3):214–219, 2010PubMedCrossRef Oda S, Awai K, Funama Y, Utsunomiya D, Yanaga Y, Kawanaka K, et al: Effects of dual-energy subtraction chest radiography on detection of small pulmonary nodules with varying attenuation: receiver operating characteristic analysis using a phantom study. Jpn J Radiol. 28(3):214–219, 2010PubMedCrossRef
10.
go back to reference Li F, Hara T, Shiraishi J, Engelmann R, MacMahon H, Doi K: Improved detection of subtle lung nodules by use of chest radiographs with bone suppression imaging: receiver operating characteristic analysis with and without localization. AJR Am J Roentgenol. 196(5):W535–W541, 2011PubMedCrossRef Li F, Hara T, Shiraishi J, Engelmann R, MacMahon H, Doi K: Improved detection of subtle lung nodules by use of chest radiographs with bone suppression imaging: receiver operating characteristic analysis with and without localization. AJR Am J Roentgenol. 196(5):W535–W541, 2011PubMedCrossRef
11.
go back to reference Balkman JD, Mehandru S, DuPont E, Novak RD, Gilkeson RC: Dual energy subtraction digital radiography improves performance of a next generation computer-aided detection program. J Thorac Imaging. 25(1):41–47, 2010PubMedCrossRef Balkman JD, Mehandru S, DuPont E, Novak RD, Gilkeson RC: Dual energy subtraction digital radiography improves performance of a next generation computer-aided detection program. J Thorac Imaging. 25(1):41–47, 2010PubMedCrossRef
12.
go back to reference Szucs-Farkas Z, Patak MA, Yuksel-Hatz S, Ruder T, Vock P: Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: comparison with human observers. Eur Radiol. 20(6):1289–1296, 2010PubMedCrossRef Szucs-Farkas Z, Patak MA, Yuksel-Hatz S, Ruder T, Vock P: Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: comparison with human observers. Eur Radiol. 20(6):1289–1296, 2010PubMedCrossRef
13.
go back to reference Freedman MT, Lo SC, Seibel JC, Bromley CM: Lung nodules: improved detection with software that suppresses the rib and clavicle on chest radiographs. Radiology. 260(1):265–273, 2011PubMedCrossRef Freedman MT, Lo SC, Seibel JC, Bromley CM: Lung nodules: improved detection with software that suppresses the rib and clavicle on chest radiographs. Radiology. 260(1):265–273, 2011PubMedCrossRef
14.
go back to reference Meziane M, Mazzone P, Novak E, Lieber ML, Lababede O, Phillips M, et al: A comparison of four versions of a computer-aided detection system for pulmonary nodules on chest radiographs. J Thorac Imaging. 27(1):58–64, 2012PubMedCrossRef Meziane M, Mazzone P, Novak E, Lieber ML, Lababede O, Phillips M, et al: A comparison of four versions of a computer-aided detection system for pulmonary nodules on chest radiographs. J Thorac Imaging. 27(1):58–64, 2012PubMedCrossRef
16.
go back to reference Kuhlman JE, Collins J, Brooks GN, Yandow DR, Broderick LS: Dual-energy subtraction chest radiography: what to look for beyond calcified nodules. Radiographics. 26(1):79–92, 2006PubMedCrossRef Kuhlman JE, Collins J, Brooks GN, Yandow DR, Broderick LS: Dual-energy subtraction chest radiography: what to look for beyond calcified nodules. Radiographics. 26(1):79–92, 2006PubMedCrossRef
17.
go back to reference Gilkeson RC, Novak RD, Sachs P: Digital radiography with dual-energy subtraction: improved evaluation of cardiac calcification. AJR Am J Roentgenol. 183(5):1233–1238, 2004PubMedCrossRef Gilkeson RC, Novak RD, Sachs P: Digital radiography with dual-energy subtraction: improved evaluation of cardiac calcification. AJR Am J Roentgenol. 183(5):1233–1238, 2004PubMedCrossRef
18.
go back to reference Mafi JN, Fei B, Roble S, Dota A, Katrapati P, Bezerra HG, et al: Assessment of coronary artery calcium using dual-energy subtraction digital radiography. J Digit Imaging. 25(1):129–136, 2012PubMedCrossRef Mafi JN, Fei B, Roble S, Dota A, Katrapati P, Bezerra HG, et al: Assessment of coronary artery calcium using dual-energy subtraction digital radiography. J Digit Imaging. 25(1):129–136, 2012PubMedCrossRef
19.
go back to reference Zompatori M, Mascalchi M, Ciccarese F, Sverzellati N, Pastorino U: Screening for lung cancer using low-dose spiral CT: 10 years later, state of the art. Radiol Med. 2013, doi:10.1007/s10278-012-9565-4 Zompatori M, Mascalchi M, Ciccarese F, Sverzellati N, Pastorino U: Screening for lung cancer using low-dose spiral CT: 10 years later, state of the art. Radiol Med. 2013, doi:10.​1007/​s10278-012-9565-4
20.
go back to reference Greenberg AK, Lu F, Goldberg JD, Eylers E, Tsay JC, Yie TA, et al: CT scan screening for lung cancer: risk factors for nodules and malignancy in a high-risk urban cohort. PLoS One 7(7):e39403, 2012PubMedCrossRef Greenberg AK, Lu F, Goldberg JD, Eylers E, Tsay JC, Yie TA, et al: CT scan screening for lung cancer: risk factors for nodules and malignancy in a high-risk urban cohort. PLoS One 7(7):e39403, 2012PubMedCrossRef
Metadata
Title
A Comparison of Computer-Aided Detection (CAD) Effectiveness in Pulmonary Nodule Identification Using Different Methods of Bone Suppression in Chest Radiographs
Authors
Ronald D. Novak
Nicholas J. Novak
Robert Gilkeson
Bahar Mansoori
Gunhild E. Aandal
Publication date
01-08-2013
Publisher
Springer US
Published in
Journal of Imaging Informatics in Medicine / Issue 4/2013
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-012-9565-4

Other articles of this Issue 4/2013

Journal of Digital Imaging 4/2013 Go to the issue