Abstract

Monitoring patients' imaging-related radiation is currently a hot topic, but there are many obstacles to accurate, patient-specific dose estimation. While some, such as easier access to dose data and parameters, have been overcome, the challenge remains as to how accurately these dose estimates reflect the actual dose received by the patient. The main parameter that is often not considered is patient size. There are many surrogates—weight, body mass index, effective diameter—but none of these truly reflect the three-dimensional “size” of an individual. In this work, we present and evaluate a novel approach to estimating patient volume using the Microsoft Kinect™, a combination RGB camera-infrared depth sensor device. The goal of using this device is to generate a three-dimensional estimate of patient size, in order to more effectively model the dimensions of the anatomy of interest and not only enable better normalization of dose estimates but also promote more patient-specific protocoling of future CT examinations. Preliminary testing and validation of this system reveals good correlation when individuals are standing upright with their arms by their sides, but demonstrates some variation with arm position. Further evaluation and testing is necessary with multiple patient positions and in both adult and pediatric patients. Correlation with other patient size metrics will also be helpful, as the ideal measure of patient “size” may in fact be a combination of existing metrics and newly developed techniques.
Literature
1.
go back to reference McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF: CT dose index and patient dose: they are not the same thing. Radiology 259(2):311–316, 2011PubMedCrossRef McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF: CT dose index and patient dose: they are not the same thing. Radiology 259(2):311–316, 2011PubMedCrossRef
2.
go back to reference Brenner DJ, McCollough C, Orton CG: Is it time to retire the CTDI for CT quality assurance and dose optimization? Med Phys 33:1189–1191, 2006PubMedCrossRef Brenner DJ, McCollough C, Orton CG: Is it time to retire the CTDI for CT quality assurance and dose optimization? Med Phys 33:1189–1191, 2006PubMedCrossRef
3.
go back to reference Hurwitz LM, Yoshizumi TT, Goodman PC, Frush DP, Nguyen G, Toncheva G, Lowry C: Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. J Comput Assist Tomogr 31(4):544–549, 2007PubMedCrossRef Hurwitz LM, Yoshizumi TT, Goodman PC, Frush DP, Nguyen G, Toncheva G, Lowry C: Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. J Comput Assist Tomogr 31(4):544–549, 2007PubMedCrossRef
4.
go back to reference Brenner DJ, Elliston CD, Hall EJ, Berdon WE: Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 176(2):289–296, 2001CrossRef Brenner DJ, Elliston CD, Hall EJ, Berdon WE: Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 176(2):289–296, 2001CrossRef
5.
go back to reference Goske MJ, Applegate KE, Boylan J, Butler PF, Callahan MJ, Coley BD, Farley S, Frush DP, Hernanz-Schulman M, Jaramillo D: The Image Gently campaign: increasing CT radiation dose awareness through a national education and awareness program. Pediatr Radiol 38(3):265–269, 2008PubMedCrossRef Goske MJ, Applegate KE, Boylan J, Butler PF, Callahan MJ, Coley BD, Farley S, Frush DP, Hernanz-Schulman M, Jaramillo D: The Image Gently campaign: increasing CT radiation dose awareness through a national education and awareness program. Pediatr Radiol 38(3):265–269, 2008PubMedCrossRef
6.
go back to reference American Association of Physicists in Medicine: Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations (Report #204), College Park, MD, 2011 American Association of Physicists in Medicine: Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations (Report #204), College Park, MD, 2011
7.
go back to reference Turner AC, Zankl M, DeMarco JJ, Cagnon CH, Zhang D, Angel E, Cody DD, Stevens DM, McCollough CH, McNitt-Gray MF: The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: using CTDIvol to account for differences between scanners. Med Phys 37(4):1816–1825, 2010PubMedCrossRef Turner AC, Zankl M, DeMarco JJ, Cagnon CH, Zhang D, Angel E, Cody DD, Stevens DM, McCollough CH, McNitt-Gray MF: The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: using CTDIvol to account for differences between scanners. Med Phys 37(4):1816–1825, 2010PubMedCrossRef
8.
go back to reference Huda W, Mettler FA: Volume CT dose index and dose-length product displayed…what good are they? Radiology 258:236–242, 2011PubMedCrossRef Huda W, Mettler FA: Volume CT dose index and dose-length product displayed…what good are they? Radiology 258:236–242, 2011PubMedCrossRef
9.
go back to reference Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Toncheva G, Yoshizumi TT, Frush DP: Patient-specific radiation dose and cancer risk estimation in CT: part II. Application to patients. Med Phys 38:408–419, 2011PubMedCrossRef Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Toncheva G, Yoshizumi TT, Frush DP: Patient-specific radiation dose and cancer risk estimation in CT: part II. Application to patients. Med Phys 38:408–419, 2011PubMedCrossRef
10.
go back to reference Li X, Segars WP, Samei E, Sturgeon GM, Colsher JG, Frush DP: Patient-specific dose estimation for pediatric chest CT. Med Phys 35:5821–5828, 2008PubMedCrossRef Li X, Segars WP, Samei E, Sturgeon GM, Colsher JG, Frush DP: Patient-specific dose estimation for pediatric chest CT. Med Phys 35:5821–5828, 2008PubMedCrossRef
Metadata
Title
Using the Microsoft Kinect for Patient Size Estimation and Radiation Dose Normalization: Proof of Concept and Initial Validation
Authors
Tessa S. Cook
Gregory Couch
Timothy J. Couch
Woojin Kim
William W. Boonn
Publication date
01-08-2013
Publisher
Springer US
Published in
Journal of Imaging Informatics in Medicine / Issue 4/2013
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-012-9567-2

Other articles of this Issue 4/2013

Journal of Digital Imaging 4/2013 Go to the issue