Skip to main content
Top
Published in: International Orthopaedics 12/2011

01-12-2011 | Original Paper

Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures

Authors: Richard Stern, Anne Lübbeke, Domizio Suva, Hermes Miozzari, Pierre Hoffmeyer

Published in: International Orthopaedics | Issue 12/2011

Login to get access

Abstract

Purpose

The purpose of this study was to compare femoral head placement, rates of reoperation and cephalic implant cut-out of a screw versus a blade for patients over age 60 with low energy trochanteric fractures (AO/OTA 31-A1, A2, and A3) treated either with sliding hip screw or cephalomedullary nail.

Methods

After surgeon selection of either hip screw or nail, hip screw patients were randomised to either a DHS (dynamic hip system screw) or DHS blade (dynamic hip system blade), while nail patients were randomised to either a Gamma3 Trochanteric Nail or a PFNA (proximal femoral nail antirotation). This resulted in a screw group (DHS and Gamma nail), and a blade group (DHS blade and PFNA). Outcome measures included tip-apex distance and zone location of the cephalic implant, as well as reoperation and implant cut-out within the first postoperative year.

Results

A total of 335 patients were randomised, 172 to a screw and 163 to a blade. There was no significant difference concerning mean tip-apex distance, percentage of patients with a tip-apex distance >25 mm, and patients with a centre–centre position of the cephalic implant. There were 137 patients in the screw group and 132 in the blade group available for follow-up. They did not differ regarding rates of reoperation or cut-out (screw group = 2.9%; blade group = 1.5%).

Conclusions

Both a screw and a blade performed equally well in terms of implant placement in the femoral head and outcome.
Literature
1.
go back to reference Barton TM, Gleeson R, Topliss C, Greenwood R, Harries WJ, Chesser TJ (2010) A comparison of the long gamma nail with the sliding hip screw for the treatment of AO/OTA 31-A2 fractures of the proximal part of the femur: a prospective randomized trial. J Bone Joint Surg Am 92:792–798PubMedCrossRef Barton TM, Gleeson R, Topliss C, Greenwood R, Harries WJ, Chesser TJ (2010) A comparison of the long gamma nail with the sliding hip screw for the treatment of AO/OTA 31-A2 fractures of the proximal part of the femur: a prospective randomized trial. J Bone Joint Surg Am 92:792–798PubMedCrossRef
2.
go back to reference Baumgaertner MR, Solberg BD (1997) Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br 79:969–971PubMedCrossRef Baumgaertner MR, Solberg BD (1997) Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br 79:969–971PubMedCrossRef
3.
go back to reference Davis TR, Sher JL, Horsman A, Simpson M, Porter BB, Checketts RG (1990) Intertrochanteric femoral fractures. Mechanical failure after internal fixation. J Bone Joint Surg Br 72:26–31PubMed Davis TR, Sher JL, Horsman A, Simpson M, Porter BB, Checketts RG (1990) Intertrochanteric femoral fractures. Mechanical failure after internal fixation. J Bone Joint Surg Br 72:26–31PubMed
4.
go back to reference Geller JA, Saifi C, Morrison TA, Macaulay W (2010) Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures. Int Orthop 34:719–722PubMedCrossRef Geller JA, Saifi C, Morrison TA, Macaulay W (2010) Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures. Int Orthop 34:719–722PubMedCrossRef
5.
go back to reference Gundle R, Gargan MF, Simpson AH (1995) How to minimize failure of fixation of unstable intertrochanteric fractures. Injury 26:611–614PubMedCrossRef Gundle R, Gargan MF, Simpson AH (1995) How to minimize failure of fixation of unstable intertrochanteric fractures. Injury 26:611–614PubMedCrossRef
6.
go back to reference Hsueh KK, Fang CK, Chen CM, Su YP, Wu HF, Chiu FY (2010) Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients. Int Orthop 34:1273–1276PubMedCrossRef Hsueh KK, Fang CK, Chen CM, Su YP, Wu HF, Chiu FY (2010) Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients. Int Orthop 34:1273–1276PubMedCrossRef
7.
go back to reference Lobo-Escolar A, Joven E, Iglesias D, Herrera A (2010) Predictive factors for cutting-out in femoral intramedullary nailing. Injury 41:1312–1316PubMedCrossRef Lobo-Escolar A, Joven E, Iglesias D, Herrera A (2010) Predictive factors for cutting-out in femoral intramedullary nailing. Injury 41:1312–1316PubMedCrossRef
8.
go back to reference Kyle RF (1994) Fractures of the proximal part of the femur. J Bone Joint Surg Am 76:924–950 Kyle RF (1994) Fractures of the proximal part of the femur. J Bone Joint Surg Am 76:924–950
9.
go back to reference Parker MJ (1992) Cutting-out of the dynamic hip screw related to its position. J Bone Joint Surg Br 74:625PubMed Parker MJ (1992) Cutting-out of the dynamic hip screw related to its position. J Bone Joint Surg Br 74:625PubMed
10.
go back to reference Walton M, Barnett A, Jackson M (2008) Tip-apex distance as a predictor of failure following cephalo-medullary fixation for unstable fractures of the proximal femur. Eur J Trauma Emerg S 34:273–276CrossRef Walton M, Barnett A, Jackson M (2008) Tip-apex distance as a predictor of failure following cephalo-medullary fixation for unstable fractures of the proximal femur. Eur J Trauma Emerg S 34:273–276CrossRef
11.
go back to reference Pervez H, Parker MJ, Vowler S (2004) Prediction of fixation failure after sliding hip screw fixation. Injury 35:994–998PubMedCrossRef Pervez H, Parker MJ, Vowler S (2004) Prediction of fixation failure after sliding hip screw fixation. Injury 35:994–998PubMedCrossRef
12.
go back to reference Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77:1058–1064PubMed Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77:1058–1064PubMed
13.
go back to reference Bannister GC, Gibson AG, Ackroyd CE, Newman JH (1990) The fixation and prognosis of trochanteric fractures. A randomized prospective controlled trial. Clin Orthop Relat Res 254:242–246PubMed Bannister GC, Gibson AG, Ackroyd CE, Newman JH (1990) The fixation and prognosis of trochanteric fractures. A randomized prospective controlled trial. Clin Orthop Relat Res 254:242–246PubMed
14.
go back to reference Chirodian N, Arch B, Parker MJ (2005) Sliding hip screw fixation of trochanteric hip fractures: outcome of 1024 procedures. Injury 36:793–800PubMedCrossRef Chirodian N, Arch B, Parker MJ (2005) Sliding hip screw fixation of trochanteric hip fractures: outcome of 1024 procedures. Injury 36:793–800PubMedCrossRef
15.
go back to reference Lenich A, Mayr E, Ruter A, Mockl C, Fuchtmeier B (2006) First results with the trochanter fixation nail (TFN): a report on 120 cases. Arch Orthop Trauma Surg 126:706–712PubMedCrossRef Lenich A, Mayr E, Ruter A, Mockl C, Fuchtmeier B (2006) First results with the trochanter fixation nail (TFN): a report on 120 cases. Arch Orthop Trauma Surg 126:706–712PubMedCrossRef
16.
go back to reference Cleveland M, Bosworth DM, Thompson FR, Wilson HJ Jr, Ishizuka T (1959) A ten-year analysis of intertrochanteric fractures of the femur. J Bone Joint Surg Am 41:1399–1408PubMed Cleveland M, Bosworth DM, Thompson FR, Wilson HJ Jr, Ishizuka T (1959) A ten-year analysis of intertrochanteric fractures of the femur. J Bone Joint Surg Am 41:1399–1408PubMed
17.
go back to reference Sahni V, Sureen S, Shetty V (2001) Who is responsible for failure of a dynamic hip screw by cutout, the patient or the surgeon? In: Proceedings of the 68th annual meeting of the American Academy of Orthopaedic Surgeons, vol 2, p 385 Sahni V, Sureen S, Shetty V (2001) Who is responsible for failure of a dynamic hip screw by cutout, the patient or the surgeon? In: Proceedings of the 68th annual meeting of the American Academy of Orthopaedic Surgeons, vol 2, p 385
18.
go back to reference Stern R (2007) Are there advances in the treatment of extracapsular hip fractures in the elderly? Injury 38(Suppl 3):S77–S87PubMedCrossRef Stern R (2007) Are there advances in the treatment of extracapsular hip fractures in the elderly? Injury 38(Suppl 3):S77–S87PubMedCrossRef
19.
go back to reference Al-Munajjed AA, Hammer J, Mayr E, Nerlich M, Lenich A (2008) Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw. Stud Health Technol Inform 133:1–10PubMed Al-Munajjed AA, Hammer J, Mayr E, Nerlich M, Lenich A (2008) Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw. Stud Health Technol Inform 133:1–10PubMed
20.
go back to reference Sommers MB, Roth C, Hall H, Kam BC, Ehmke LW, Krieg JC et al (2004) A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation. J Orthop Trauma 18:361–368PubMedCrossRef Sommers MB, Roth C, Hall H, Kam BC, Ehmke LW, Krieg JC et al (2004) A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation. J Orthop Trauma 18:361–368PubMedCrossRef
21.
go back to reference Strauss E, Frank J, Lee J, Kummer FJ, Tejwani N (2006) Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation. Injury 37:984–989PubMedCrossRef Strauss E, Frank J, Lee J, Kummer FJ, Tejwani N (2006) Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation. Injury 37:984–989PubMedCrossRef
22.
go back to reference Windolf M, Braunstein V, Dutoit C, Schwieger K (2009) Is a helical shaped implant a superior alternative to the dynamic hip screw for unstable femoral neck fractures? A biomechanical investigation. Clin Biomech (Bristol, Avon) 24:59–64CrossRef Windolf M, Braunstein V, Dutoit C, Schwieger K (2009) Is a helical shaped implant a superior alternative to the dynamic hip screw for unstable femoral neck fractures? A biomechanical investigation. Clin Biomech (Bristol, Avon) 24:59–64CrossRef
23.
go back to reference Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA et al (2007) Fracture and dislocation classification compendium—2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21:S1–S133PubMedCrossRef Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA et al (2007) Fracture and dislocation classification compendium—2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21:S1–S133PubMedCrossRef
24.
go back to reference Anglen JO, Weinstein JN (2008) Nail or plate fixation of intertrochanteric hip fractures: changing pattern of practice. A review of the American Board of Orthopaedic Surgery Database. J Bone Joint Surg Am 90:700–707PubMedCrossRef Anglen JO, Weinstein JN (2008) Nail or plate fixation of intertrochanteric hip fractures: changing pattern of practice. A review of the American Board of Orthopaedic Surgery Database. J Bone Joint Surg Am 90:700–707PubMedCrossRef
25.
go back to reference Forte ML, Virnig BA, Eberly LE, Swiontkowski MF, Feldman R, Bhandari M et al (2010) Provider factors associated with intramedullary nail use for intertrochanteric hip fractures. J Bone Joint Surg Am 92:1105–1114PubMedCrossRef Forte ML, Virnig BA, Eberly LE, Swiontkowski MF, Feldman R, Bhandari M et al (2010) Provider factors associated with intramedullary nail use for intertrochanteric hip fractures. J Bone Joint Surg Am 92:1105–1114PubMedCrossRef
26.
go back to reference Parker MJ, Handoll HH (2008) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev 3:CD000093 Parker MJ, Handoll HH (2008) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev 3:CD000093
27.
go back to reference Saudan M, Lubbeke A, Sadowski C, Riand N, Stern R, Hoffmeyer P (2002) Pertrochanteric fractures: is there an advantage to an intramedullary nail?: a randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail. J Orthop Trauma 16:386–393PubMedCrossRef Saudan M, Lubbeke A, Sadowski C, Riand N, Stern R, Hoffmeyer P (2002) Pertrochanteric fractures: is there an advantage to an intramedullary nail?: a randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail. J Orthop Trauma 16:386–393PubMedCrossRef
28.
go back to reference Kuzyk PR, Lobo J, Whelan D, Zdero R, McKee MD, Schemitsch EH (2009) Biomechanical evaluation of extramedullary versus intramedullary fixation for reverse obliquity intertrochanteric fractures. J Orthop Trauma 23:31–38PubMedCrossRef Kuzyk PR, Lobo J, Whelan D, Zdero R, McKee MD, Schemitsch EH (2009) Biomechanical evaluation of extramedullary versus intramedullary fixation for reverse obliquity intertrochanteric fractures. J Orthop Trauma 23:31–38PubMedCrossRef
29.
go back to reference Park SY, Yang KH, Yoo JH, Yoon HK, Park HW (2008) The treatment of reverse obliquity intertrochanteric fractures with the intramedullary hip nail. J Trauma 65:852–857PubMedCrossRef Park SY, Yang KH, Yoo JH, Yoon HK, Park HW (2008) The treatment of reverse obliquity intertrochanteric fractures with the intramedullary hip nail. J Trauma 65:852–857PubMedCrossRef
30.
go back to reference Johnson LJ, Cope MR, Shahrokhi S, Tamblyn P (2008) Measuring tip-apex distance using a picture archiving and communication system (PACS). Injury 39:786–790PubMedCrossRef Johnson LJ, Cope MR, Shahrokhi S, Tamblyn P (2008) Measuring tip-apex distance using a picture archiving and communication system (PACS). Injury 39:786–790PubMedCrossRef
31.
go back to reference Zuckerman JD, Koval KJ, Aharonoff GB, Hiebert R, Skovron ML (2000) A functional recovery score for elderly hip fracture patients: I. Development. J Orthop Trauma 14:20–25PubMedCrossRef Zuckerman JD, Koval KJ, Aharonoff GB, Hiebert R, Skovron ML (2000) A functional recovery score for elderly hip fracture patients: I. Development. J Orthop Trauma 14:20–25PubMedCrossRef
32.
go back to reference Zuckerman JD, Koval KJ, Aharonoff GB, Skovron ML (2000) A functional recovery score for elderly hip fracture patients: II. Validity and reliability. J Orthop Trauma 14:26–30PubMedCrossRef Zuckerman JD, Koval KJ, Aharonoff GB, Skovron ML (2000) A functional recovery score for elderly hip fracture patients: II. Validity and reliability. J Orthop Trauma 14:26–30PubMedCrossRef
33.
go back to reference Lindsey RW, Ahmed S, Overturf S, Tan A, Gugala Z (2009) Accuracy of lag screw placement for the dynamic hip screw and the cephalomedullary nail. Orthopedics 32:488PubMedCrossRef Lindsey RW, Ahmed S, Overturf S, Tan A, Gugala Z (2009) Accuracy of lag screw placement for the dynamic hip screw and the cephalomedullary nail. Orthopedics 32:488PubMedCrossRef
34.
go back to reference Simmermacher RK, Ljungqvist J, Bail H, Hockertz T, Vochteloo AJ, Ochs U et al (2008) The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study. Injury 39:932–939PubMedCrossRef Simmermacher RK, Ljungqvist J, Bail H, Hockertz T, Vochteloo AJ, Ochs U et al (2008) The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study. Injury 39:932–939PubMedCrossRef
35.
go back to reference Lenich A, Vester H, Nerlich M, Mayr E, Stockle U, Fuchtmeier B (2010) Clinical comparison of the second and third generation of intramedullary devices for trochanteric fractures of the hip-blade vs screw. Injury 41:1292–1296PubMedCrossRef Lenich A, Vester H, Nerlich M, Mayr E, Stockle U, Fuchtmeier B (2010) Clinical comparison of the second and third generation of intramedullary devices for trochanteric fractures of the hip-blade vs screw. Injury 41:1292–1296PubMedCrossRef
36.
go back to reference Park JH, Lee YS, Park JW, Wang JH, Kim JG (2010) A comparative study of screw and helical proximal femoral nails for the treatment of intertrochanteric fractures. Orthopedics 33:81–85PubMedCrossRef Park JH, Lee YS, Park JW, Wang JH, Kim JG (2010) A comparative study of screw and helical proximal femoral nails for the treatment of intertrochanteric fractures. Orthopedics 33:81–85PubMedCrossRef
37.
go back to reference Yaozeng X, Dechun G, Huilin Y, Guangming Z, Xianbin W (2010) Comparative study of trochanteric fracture treated with the proximal femoral nail anti-rotation and the third generation of gamma nail. Injury 41:1234–1238PubMedCrossRef Yaozeng X, Dechun G, Huilin Y, Guangming Z, Xianbin W (2010) Comparative study of trochanteric fracture treated with the proximal femoral nail anti-rotation and the third generation of gamma nail. Injury 41:1234–1238PubMedCrossRef
Metadata
Title
Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures
Authors
Richard Stern
Anne Lübbeke
Domizio Suva
Hermes Miozzari
Pierre Hoffmeyer
Publication date
01-12-2011
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 12/2011
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-011-1232-8

Other articles of this Issue 12/2011

International Orthopaedics 12/2011 Go to the issue