Skip to main content
Top
Published in: International Orthopaedics 5/2010

01-06-2010 | Original Paper

Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures

Authors: Jeffrey A. Geller, Comron Saifi, Todd A. Morrison, William Macaulay

Published in: International Orthopaedics | Issue 5/2010

Login to get access

Abstract

A tip-apex distance (TAD) of greater than 25 mm has been shown to be an accurate predictor of lag screw cut-out when sliding hip screws (SHS) are used to treat peritrochanteric (PT) hip fractures. The purpose of this study was to determine which factors, including TAD, correlated with successful clinical outcomes of PT hip fractures surgically treated with intramedullary (IM) devices. A total of 192 patients were included in this retrospective study. The TAD values of this cohort were radiographically analysed at a mean follow-up of 13 months. This was correlated with limited functional status and the rate of revision for implant failure or inability to achieve fracture union. Only 82 patients had adequate follow-up to fracture union or definitive failure. There were 46 intertrochanteric (IT) hip fractures and 36 subtrochanteric (ST) fractures. Overall, seven patients (8.5%) went on to experience lag screw cut-out. The average TAD of the patients who did not cut-out was 18 mm, compared to 38 mm for those who did (p = 0.012). All patients who cut-out had IT fractures (p = 0.017). The percentage of cut-outs correlated directly to both the severity of IT fractures and the TAD. Using a cutoff of 25 mm there was a statistically significant difference in the incidence of lag screw cut-out (p < 0.001). As in sliding hip screws, surgeons should strive for a TAD less than 25 mm when using IM devices in the treatment of PT hip fractures to help avoid lag screw cut-out.
Literature
1.
go back to reference Johnell O, Kanis JA (2004) An estimate of the worldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int 15(11):897–902CrossRefPubMed Johnell O, Kanis JA (2004) An estimate of the worldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int 15(11):897–902CrossRefPubMed
2.
go back to reference Hannan EL, Magaziner J, Wang JJ, Eastwood EA, Silberzweig SB, Gillbert M, Morrison RS, McLaughlin MA, Orosz GM, Siu AL (2001) Mortality and locomotion 6 months after hospitalization for hip fracture: risk factors and risk-adjusted hospital outcomes. JAMA 285(21):2736–2742CrossRefPubMed Hannan EL, Magaziner J, Wang JJ, Eastwood EA, Silberzweig SB, Gillbert M, Morrison RS, McLaughlin MA, Orosz GM, Siu AL (2001) Mortality and locomotion 6 months after hospitalization for hip fracture: risk factors and risk-adjusted hospital outcomes. JAMA 285(21):2736–2742CrossRefPubMed
3.
go back to reference van Balen, R, Steyerberg EW, Polder JJ, Ribbers TL, Habbema JD, Cools HG (2001) Hip fracture in elderly patients: outcomes for function, quality of life, and type of residence. Clin Orthop Relat Res (390):232–243 van Balen, R, Steyerberg EW, Polder JJ, Ribbers TL, Habbema JD, Cools HG (2001) Hip fracture in elderly patients: outcomes for function, quality of life, and type of residence. Clin Orthop Relat Res (390):232–243
4.
go back to reference Braithwaite RS, Col NF, Wong JB (2003) Estimating hip fracture morbidity, mortality and costs. J Am Geriatr Soc 51(3):364–370CrossRefPubMed Braithwaite RS, Col NF, Wong JB (2003) Estimating hip fracture morbidity, mortality and costs. J Am Geriatr Soc 51(3):364–370CrossRefPubMed
5.
go back to reference Burge R, Dawson-Hughes B, Solomon DH, Wong JB, King A, Tosteson A (2007) Incidence and economic burden of osteoporosis-related fractures in the United States, 2005–2025. J Bone Miner Res 22(3):465–475CrossRefPubMed Burge R, Dawson-Hughes B, Solomon DH, Wong JB, King A, Tosteson A (2007) Incidence and economic burden of osteoporosis-related fractures in the United States, 2005–2025. J Bone Miner Res 22(3):465–475CrossRefPubMed
7.
go back to reference Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop Relat Res (348):87–94 Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop Relat Res (348):87–94
8.
go back to reference Sadowski C, Lübbeke A, Saudan M, Riand N, Stern R, Hoffmeyer P (2002) Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am 84-A(3):372–381PubMed Sadowski C, Lübbeke A, Saudan M, Riand N, Stern R, Hoffmeyer P (2002) Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am 84-A(3):372–381PubMed
9.
go back to reference Park SR, Kang JS, Kim HS, Lee WH, Kim YH (1998) Treatment of intertrochanteric fracture with the gamma AP locking nail or by a compression hip screw-a randomised prospective trial. Int Orthop 22(3):157–160CrossRefPubMed Park SR, Kang JS, Kim HS, Lee WH, Kim YH (1998) Treatment of intertrochanteric fracture with the gamma AP locking nail or by a compression hip screw-a randomised prospective trial. Int Orthop 22(3):157–160CrossRefPubMed
10.
go back to reference Utrilla AL, Reig JS, Muñoz FM, Tufanisco CB (2005) Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma 19(4):229–233CrossRefPubMed Utrilla AL, Reig JS, Muñoz FM, Tufanisco CB (2005) Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma 19(4):229–233CrossRefPubMed
11.
go back to reference Mahomed N, Harrington I, Kellam J, Maistrelli G, Hearn T, Vroemen J (1994) Biomechanical analysis of the gamma nail and sliding hip screw. Clin Orthop Relat Res (304):280–288 Mahomed N, Harrington I, Kellam J, Maistrelli G, Hearn T, Vroemen J (1994) Biomechanical analysis of the gamma nail and sliding hip screw. Clin Orthop Relat Res (304):280–288
12.
go back to reference Liu M, Yang Z, Pei F, Huang F, Chen S, Xiang Z (2009) A meta-analysis of gamma nail and dynamic hip screw in treating peritrochanteric fractures. Int Orthop. doi:10.1007/s00264-009-0783-4 Liu M, Yang Z, Pei F, Huang F, Chen S, Xiang Z (2009) A meta-analysis of gamma nail and dynamic hip screw in treating peritrochanteric fractures. Int Orthop. doi:10.​1007/​s00264-009-0783-4
13.
go back to reference Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77(7):1058–1064PubMed Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77(7):1058–1064PubMed
14.
go back to reference Baumgaertner MR, Solberg BD (1997) Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br 79(6):969–971CrossRefPubMed Baumgaertner MR, Solberg BD (1997) Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br 79(6):969–971CrossRefPubMed
15.
go back to reference Kyle RF, Gustilo RB, Premer RF (1979) Analysis of six hundred and twenty-two intertrochanteric hip fractures. J Bone Joint Surg Am 61(2):216–221PubMed Kyle RF, Gustilo RB, Premer RF (1979) Analysis of six hundred and twenty-two intertrochanteric hip fractures. J Bone Joint Surg Am 61(2):216–221PubMed
16.
go back to reference Seinsheimer F (1978) Subtrochanteric fractures of the femur. J Bone Joint Surg Am 60(3):300–306PubMed Seinsheimer F (1978) Subtrochanteric fractures of the femur. J Bone Joint Surg Am 60(3):300–306PubMed
17.
go back to reference Shyam Kumar AJ, Parmar V, Bankart J, William C, Harper WM (2006) Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur. Int Orthop 30(5):320–324CrossRefPubMed Shyam Kumar AJ, Parmar V, Bankart J, William C, Harper WM (2006) Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur. Int Orthop 30(5):320–324CrossRefPubMed
18.
go back to reference Cummings SR, Rubin SM, Black D (1990) The future of hip fractures in the United States. Numbers, costs, and potential effects of postmenopausal estrogen. Clin Orthop Relat Res (252):163–166 Cummings SR, Rubin SM, Black D (1990) The future of hip fractures in the United States. Numbers, costs, and potential effects of postmenopausal estrogen. Clin Orthop Relat Res (252):163–166
19.
go back to reference US Congress (1994) Hip fracture outcomes in people age 50 and over. Background paper. Government Printing Office, Washington, DC, USA US Congress (1994) Hip fracture outcomes in people age 50 and over. Background paper. Government Printing Office, Washington, DC, USA
Metadata
Title
Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures
Authors
Jeffrey A. Geller
Comron Saifi
Todd A. Morrison
William Macaulay
Publication date
01-06-2010
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 5/2010
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-009-0837-7

Other articles of this Issue 5/2010

International Orthopaedics 5/2010 Go to the issue