A look ahead: PET/MR versus PET/CT

Authors: Gustav K. von Schulthess, Heinz-Peter W. Schlemmer

Published in: European Journal of Nuclear Medicine and Molecular Imaging | Special Issue 1/2009

Login to get access

Abstract

Introduction

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years.

Objectives

In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used.

Discussion

The authors conclude that combining PET/MR is an interesting research endeavor with uncertain outcome. They argue that, while completely simultaneous brain applications are of research interest immediately, clinical applications do not currently warrant the construction of fully integrated systems. Systems adjacent to each other, where imaging tables are linked with a patient “shuttle” thereby requiring only patient translation but no repositioning, may be a good start to assess the value of integrated PET/MR.
Literature
1.
go back to reference Seo Y, Mari C, Hasegawa BH. Technological development and advances in single-photon emission computed tomography/computed tomography. Semin Nucl Med. 2008;38(3):177–98. May.PubMedCrossRef Seo Y, Mari C, Hasegawa BH. Technological development and advances in single-photon emission computed tomography/computed tomography. Semin Nucl Med. 2008;38(3):177–98. May.PubMedCrossRef
2.
go back to reference Hasegawa BH, Gingold EL, Reilly SM, Liew SC, Cann CE. Description of a simultaneous emission-transmission CT system. Proc SPIE. 1990;1231:50–60.CrossRef Hasegawa BH, Gingold EL, Reilly SM, Liew SC, Cann CE. Description of a simultaneous emission-transmission CT system. Proc SPIE. 1990;1231:50–60.CrossRef
3.
go back to reference Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, et al. A combined PET/CT scanner for clinical oncology. J Nuc Med. 2000;41:1369–79. Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, et al. A combined PET/CT scanner for clinical oncology. J Nuc Med. 2000;41:1369–79.
4.
go back to reference Kinahan PE, et al. Attenuation correction for a combined 3D PET/CT scanner. Med Phys. 1998;25:2046–53.PubMedCrossRef Kinahan PE, et al. Attenuation correction for a combined 3D PET/CT scanner. Med Phys. 1998;25:2046–53.PubMedCrossRef
5.
go back to reference Burger C, Goerres GW, Schoenes S, Buck A, Lonn AHR, von Schulthess GK. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT- into PET 511 keV attenuation coefficients. Europ J Nucl Med. 2002;29(7):922–7.CrossRef Burger C, Goerres GW, Schoenes S, Buck A, Lonn AHR, von Schulthess GK. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT- into PET 511 keV attenuation coefficients. Europ J Nucl Med. 2002;29(7):922–7.CrossRef
6.
go back to reference Hany TF, Steinert HC, Goerres GW, Buck A, von Schulthess GK. PET diagnostic accuracy: improvement with in-line PET/CT System: initial results. Radiology. 2002;225:575–81.PubMedCrossRef Hany TF, Steinert HC, Goerres GW, Buck A, von Schulthess GK. PET diagnostic accuracy: improvement with in-line PET/CT System: initial results. Radiology. 2002;225:575–81.PubMedCrossRef
7.
go back to reference von Schulthess GK. Cost considerations regarding an integrated CT-PET system. Eur Radiol. 2000;Suppl 3:377–80. von Schulthess GK. Cost considerations regarding an integrated CT-PET system. Eur Radiol. 2000;Suppl 3:377–80.
8.
go back to reference Lardinois D, Weder W, Hany TF, Kamel EM, Korom S, Seifert B, et al. Integrated PET/CT imaging improves staging of non-small-cell lung cancer. N Engl J Med. 2003;348(25):2500–7.PubMedCrossRef Lardinois D, Weder W, Hany TF, Kamel EM, Korom S, Seifert B, et al. Integrated PET/CT imaging improves staging of non-small-cell lung cancer. N Engl J Med. 2003;348(25):2500–7.PubMedCrossRef
9.
go back to reference Czernin J, Allen-Auerbach M, Schelbert HR. Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006. J Nucl Med. 2007;48(Suppl 1):78S–88S. Jan.PubMed Czernin J, Allen-Auerbach M, Schelbert HR. Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006. J Nucl Med. 2007;48(Suppl 1):78S–88S. Jan.PubMed
10.
go back to reference Hillner BE, Siegel BA, Liu D, Shields AF, Gareen IF, Hanna L, et al. Impact of positron emission tomography/computed tomography and positron emission tomography (PET) alone on expected management of patients with cancer: initial results from the National Oncologic PET Registry. Clin Oncol. 2008;26(13):2155–61. May 1.CrossRef Hillner BE, Siegel BA, Liu D, Shields AF, Gareen IF, Hanna L, et al. Impact of positron emission tomography/computed tomography and positron emission tomography (PET) alone on expected management of patients with cancer: initial results from the National Oncologic PET Registry. Clin Oncol. 2008;26(13):2155–61. May 1.CrossRef
11.
go back to reference Gambhir SS, Czernin J, Schwimmer J, Silverman DH, Coleman RE, Phelps ME. A tabulated summary of the FDG PET literature. J Nucl Med. 2001;42(5 Suppl):1S–93S. May.PubMed Gambhir SS, Czernin J, Schwimmer J, Silverman DH, Coleman RE, Phelps ME. A tabulated summary of the FDG PET literature. J Nucl Med. 2001;42(5 Suppl):1S–93S. May.PubMed
12.
go back to reference Brix G, Lechel U, Glatting G, Ziegler SI, Münzing W, Müller SP, et al. Radiation exposure of patients undergoing whole-body dual-modality 18F-FDG PET/CT examinations. J Nucl Med. 2005;46(4):608–13. Apr.PubMed Brix G, Lechel U, Glatting G, Ziegler SI, Münzing W, Müller SP, et al. Radiation exposure of patients undergoing whole-body dual-modality 18F-FDG PET/CT examinations. J Nucl Med. 2005;46(4):608–13. Apr.PubMed
13.
go back to reference Pichler BJ, Judenhofer MS, Catana C, Walton JH, Kneilling M, Nutt RE, et al. Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI. J Nucl Med. 2006;47(4):639–47.PubMed Pichler BJ, Judenhofer MS, Catana C, Walton JH, Kneilling M, Nutt RE, et al. Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI. J Nucl Med. 2006;47(4):639–47.PubMed
14.
go back to reference Schlemmer HP, Pichler B, Wienhard K, et al. Simultaneous MR/PET for Brain Imaging: first Patient Scans. J Nucl Med. 2007;48(Suppl):152. Schlemmer HP, Pichler B, Wienhard K, et al. Simultaneous MR/PET for Brain Imaging: first Patient Scans. J Nucl Med. 2007;48(Suppl):152.
15.
go back to reference Schlemmer HP, Pichler BJ, Schmand M, Burbar Z, Michel C, Ladebeck R, et al. Simultaneous MR/PET imaging of the human brain: a feasibility study. Radiology. 2008;248:1028–35.PubMedCrossRef Schlemmer HP, Pichler BJ, Schmand M, Burbar Z, Michel C, Ladebeck R, et al. Simultaneous MR/PET imaging of the human brain: a feasibility study. Radiology. 2008;248:1028–35.PubMedCrossRef
16.
go back to reference Judenhofer MS, Catana C, Swann BK, Siegel SB, Jung WI, Nutt RF, et al. PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet. Radiology. 2007;244(3):807–14.PubMedCrossRef Judenhofer MS, Catana C, Swann BK, Siegel SB, Jung WI, Nutt RF, et al. PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet. Radiology. 2007;244(3):807–14.PubMedCrossRef
17.
go back to reference Judenhofer MS, Wehrl HF, Newport DF, Catana C, Siegel SB, Becker M, et al. Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat Med. 2008;14(4):459–65. Apr.PubMedCrossRef Judenhofer MS, Wehrl HF, Newport DF, Catana C, Siegel SB, Becker M, et al. Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat Med. 2008;14(4):459–65. Apr.PubMedCrossRef
18.
go back to reference Beyer T, Weigert M, Quick HH, Pietrzyk U, Vogt F, Palm C, et al. MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data. Eur J Nucl Med Mol Imaging. 2008;35(6):1142–6.PubMedCrossRef Beyer T, Weigert M, Quick HH, Pietrzyk U, Vogt F, Palm C, et al. MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data. Eur J Nucl Med Mol Imaging. 2008;35(6):1142–6.PubMedCrossRef
19.
go back to reference Zaidi H, Montandon ML, Slosman DO. Attenuation compensation in cerebral 3D PET: effect of the attenuation map on absolute and relative quantitation. Eur J Nucl Med Mol Imaging. 2004;31(1):52–63.PubMedCrossRef Zaidi H, Montandon ML, Slosman DO. Attenuation compensation in cerebral 3D PET: effect of the attenuation map on absolute and relative quantitation. Eur J Nucl Med Mol Imaging. 2004;31(1):52–63.PubMedCrossRef
20.
go back to reference Hofmann M, Steinke F, Scheel V, Charpiat G, Farquhar J, Aschoff P, et al. MR-based attenuation correction for PET/MR: a novel approach combining pattern recognition and atlas registration. J Nucl Med. 2008; (in press). Hofmann M, Steinke F, Scheel V, Charpiat G, Farquhar J, Aschoff P, et al. MR-based attenuation correction for PET/MR: a novel approach combining pattern recognition and atlas registration. J Nucl Med. 2008; (in press).
21.
go back to reference Carroll TJ, Teneggi V, Jobin M, Squassante L, Treyer V, Hany TF, et al. Absolute quantification of cerebral blood flow with magnetic resonance, reproducibility of the method, and comparison with H2(15)O positron emission tomography. J Cereb Blood Flow Metab. 2002;22(9):1149–56. Sep.PubMedCrossRef Carroll TJ, Teneggi V, Jobin M, Squassante L, Treyer V, Hany TF, et al. Absolute quantification of cerebral blood flow with magnetic resonance, reproducibility of the method, and comparison with H2(15)O positron emission tomography. J Cereb Blood Flow Metab. 2002;22(9):1149–56. Sep.PubMedCrossRef
22.
go back to reference Antoch G, Vogt FM, Freudenberg LS, Nazaradeh F, Goehde SC, Barkhausen J, et al. Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology. JAMA. 2003;290(24):3199–206. Dec 24.PubMedCrossRef Antoch G, Vogt FM, Freudenberg LS, Nazaradeh F, Goehde SC, Barkhausen J, et al. Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology. JAMA. 2003;290(24):3199–206. Dec 24.PubMedCrossRef
23.
go back to reference Muller-Horvat C, Radny P, Eigentler TK, Schafer J, Pfannenberg C, Horger M, et al. Prospective comparison of the impact on treatment decisions of whole-body magnetic resonance imaging and computed tomography in patients with metastatic malignant melanoma. Eur J Cancer. 2006;42(3):342–50.PubMedCrossRef Muller-Horvat C, Radny P, Eigentler TK, Schafer J, Pfannenberg C, Horger M, et al. Prospective comparison of the impact on treatment decisions of whole-body magnetic resonance imaging and computed tomography in patients with metastatic malignant melanoma. Eur J Cancer. 2006;42(3):342–50.PubMedCrossRef
24.
go back to reference Pfannenberg AC, Aschoff P, Eschmann SM, Plathow C, Eigentler TK, Garbe C, et al. Prospective comparison of 18F-fluorodeoxyglucose positron emission tomography/computed tomography and whole-body magnetic resonance imaging in staging of advanced malignant melanoma. Eur J Cancer. 2007;43(3):557–64.PubMedCrossRef Pfannenberg AC, Aschoff P, Eschmann SM, Plathow C, Eigentler TK, Garbe C, et al. Prospective comparison of 18F-fluorodeoxyglucose positron emission tomography/computed tomography and whole-body magnetic resonance imaging in staging of advanced malignant melanoma. Eur J Cancer. 2007;43(3):557–64.PubMedCrossRef
25.
go back to reference Bischof Delaloye A, Carrió I, Cuocolo A, Knapp W, Gourtsoyiannis N, McCall I, et al. White paper of the European Association of Nuclear Medicine (EANM) and the European Society of Radiology (ESR) on multimodality imaging. Eur J Nucl Med Mol Imaging. 2007;34(8):1147–51. Aug.PubMedCrossRef Bischof Delaloye A, Carrió I, Cuocolo A, Knapp W, Gourtsoyiannis N, McCall I, et al. White paper of the European Association of Nuclear Medicine (EANM) and the European Society of Radiology (ESR) on multimodality imaging. Eur J Nucl Med Mol Imaging. 2007;34(8):1147–51. Aug.PubMedCrossRef
Metadata
Title
A look ahead: PET/MR versus PET/CT
Authors
Gustav K. von Schulthess
Heinz-Peter W. Schlemmer
Publication date
01-03-2009
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue Special Issue 1/2009
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-008-0940-9

Other articles of this Special Issue 1/2009

European Journal of Nuclear Medicine and Molecular Imaging 1/2009 Go to the issue