Skip to main content
Top
Published in: Skeletal Radiology 5/2021

01-05-2021 | Magnetic Resonance Imaging | Case Report

Multimodal imaging of composite carbon fiber–based implants for orthopedic spinal fixation

Authors: Francis T Delaney, Hazel Denton, Michael Dodds, Eoin C Kavanagh

Published in: Skeletal Radiology | Issue 5/2021

Login to get access

Abstract

Objective

As cancer treatments continue to improve, the incidence of spinal metastases and the need for surgical management of these with fixation procedures are growing rapidly. Traditionally metallic implants, composed of titanium alloy, have been used in surgical fixation of unstable or symptomatic vertebral metastases or traumatic injuries. Metallic implants, however, cause significant artifact on post-operative imaging, degrading image quality and limiting interpretation, and can also impair the planning and delivery of radiotherapy. Composite carbon fiber–based materials, such as carbon fiber–reinforced polyetheretherketone (PEEK), have been developed to overcome these issues and are now available for spinal fixation procedures. We aimed to review the multimodal imaging features of these new implants.

Materials and methods

Current literature and a case example from our institution were used to describe the multimodal imaging characteristics and considerations of new carbon fiber-based spinal fixation implants.

Results

New carbon fiber-based spinal implants allow far greater visualization of surrounding structures on post-operative cross-sectional imaging, significantly improving diagnostic accuracy and precision of radiotherapy planning, and do not significantly absorb or scatter X-ray photons during radiotherapy delivery. There are, however, important surgical and radiologic considerations associated with the use of carbon fiber-based implants which radiologists must be aware of, such as implications for surgical planning and intra-operative fluoroscopic and post-operative plain radiographic imaging.

Conclusion

The use of carbon fiber-based implants, rather than traditional metallic implants, for spinal fixation offers significant advantages for post-operative diagnostic imaging and radiotherapy planning and delivery.
Literature
Metadata
Title
Multimodal imaging of composite carbon fiber–based implants for orthopedic spinal fixation
Authors
Francis T Delaney
Hazel Denton
Michael Dodds
Eoin C Kavanagh
Publication date
01-05-2021
Publisher
Springer Berlin Heidelberg
Published in
Skeletal Radiology / Issue 5/2021
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-020-03622-6

Other articles of this Issue 5/2021

Skeletal Radiology 5/2021 Go to the issue