Abstract

Bone resorption in the proximal femur is commonly seen after total hip arthroplasty (THA). With dual energy X-ray absorptiometry (DXA), the amount of bone mass (BMD) after implantation of a total hip stem can be precisely determined. However, prospective evaluation of the change of bone mass around the stem is only available for selected stems and short-term follow-up (up to 36 months). We analyzed BMD in patients who had undergone uncemented THA by DXA. Only patients with good clinical outcome (Merle d’ Aubigné score > 12) were included to obtain normative data for regular bone response. Two separate studies were performed: a prospective longitudinal study over 84 months with baseline values acquired within the first postoperative week (group A) (n = 26 patients) and a separate cross-sectional study, median follow-up 156 (124-178) months (group B) (n = 35 patients). Regions of interest were defined according to Gruen (ROI 1-7) and as net average ROI (net avg) for the periprosthetic femoral bone. After the initial remodeling process (12 months), BMD was compared to the 84-month (longitudinal) and the 156-month (cross-sectional) follow-up values to determine long-term periprosthetic changes of bone mineral density. The longitudinal study (group A), after the initial bone remodeling, showed no relevant further bone loss for women and men with BMD values 1.19 ± 0.15 and 1.40 ± 0.19, respectively, 12 months (women 89.8%, men 93.6%), and 1.19 ± 0.13 and 1.36 ± 0.18, respectively, after 84 months (women 90.0%, men 91.3%) (P = 0.98, P = 0.08,) respectively. The distribution of the BMD around the stem changed during the first 12 months. The ROIs around the proximal stem (ROI 1 and 7) showed the lowest absolute values at the 12-month follow-up and BMD in ROI 7 decreased most during the further follow-up until 84 months. The cross-sectional study (group B) showed no significant difference in BMD (net avg) values at a median of 156 months follow-up compared to the 12-month values (group A) (women: P = 0.77, men: P = 0.44). Initial BMD, implant diameter, and body mass index did not influence BMD loss (net avg) in this study, whereas age showed a weak correlation with BMD loss. The results show that after the initial remodeling process, no relevant further bone loss (net avg) occurs up to 84 months postsurgery, and values after a median of 156 months are similar. Normative long-term changes in the periprosthetic bone can be demonstrated in defined ROIs after implantation of a tapered corundum-blasted titanium stem with a good clinical result.
Literature
1.
go back to reference Ang, KC, Das De, S, Goh, JC, Low, SL, Bose, K 1997Periprosthetic bone remodelling after cementless total hip replacement. A prospective comparison of two different implant designs.J Bone Joint Surg Br79675679CrossRefPubMed Ang, KC, Das De, S, Goh, JC, Low, SL, Bose, K 1997Periprosthetic bone remodelling after cementless total hip replacement. A prospective comparison of two different implant designs.J Bone Joint Surg Br79675679CrossRefPubMed
2.
go back to reference Kiratli, BJ, Heiner, JP, McBeath, AA, Wilson, MA 1992Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty.J Orthop Res10836844PubMed Kiratli, BJ, Heiner, JP, McBeath, AA, Wilson, MA 1992Determination of bone mineral density by dual x-ray absorptiometry in patients with uncemented total hip arthroplasty.J Orthop Res10836844PubMed
3.
go back to reference Kiratli, BJ, Checovich, MM, McBeath, AA, Wilson, MA, Heiner, JP 1996Measurement of bone mineral density by dual-energy x-ray absorptiometry in patients with the Wisconsin hip, an uncemented femoral stem.J Arthroplasty11184193PubMed Kiratli, BJ, Checovich, MM, McBeath, AA, Wilson, MA, Heiner, JP 1996Measurement of bone mineral density by dual-energy x-ray absorptiometry in patients with the Wisconsin hip, an uncemented femoral stem.J Arthroplasty11184193PubMed
4.
go back to reference Sabo, D, Reiter, A, Simank, HG, Thomsen, M, Lukoschek, M, Ewerbeck, V 1998Periprosthetic mineralization around cementless total hip endoprosthesis: longitudinal study and cross-sectional study on titanium-threaded acetabular cup and cementless Spotorno stem with DEXA.Calcif Tissue Int62177182CrossRefPubMed Sabo, D, Reiter, A, Simank, HG, Thomsen, M, Lukoschek, M, Ewerbeck, V 1998Periprosthetic mineralization around cementless total hip endoprosthesis: longitudinal study and cross-sectional study on titanium-threaded acetabular cup and cementless Spotorno stem with DEXA.Calcif Tissue Int62177182CrossRefPubMed
5.
go back to reference Trevisan, C, Bigoni, M, Randelli, G, Marinoni, EC, Peretti, G, Ortolani, S 1997Periprosthetic bone density around fully hydroxyapatite coated femoral stem.Clin Orthop340109117 Trevisan, C, Bigoni, M, Randelli, G, Marinoni, EC, Peretti, G, Ortolani, S 1997Periprosthetic bone density around fully hydroxyapatite coated femoral stem.Clin Orthop340109117
6.
go back to reference Venesmaa, PK, Kroger, HP, Miettinen, HJ, Jurvelin, JS, Suomalainen, OT, Alhava, EM 2001Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual-energy X-ray absorptiometry — a 3-year follow-up study.J Bone Miner Res1610561061PubMed Venesmaa, PK, Kroger, HP, Miettinen, HJ, Jurvelin, JS, Suomalainen, OT, Alhava, EM 2001Monitoring of periprosthetic BMD after uncemented total hip arthroplasty with dual-energy X-ray absorptiometry — a 3-year follow-up study.J Bone Miner Res1610561061PubMed
7.
go back to reference Yamaguchi, K, Masuhara, K, Ohzono, K, Sugano, N, Nishii, T, Ochi, T 2000Evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. The influence of the extent of porous coating.J Bone Joint Surg Am82-A14261431PubMed Yamaguchi, K, Masuhara, K, Ohzono, K, Sugano, N, Nishii, T, Ochi, T 2000Evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. The influence of the extent of porous coating.J Bone Joint Surg Am82-A14261431PubMed
8.
9.
go back to reference West, JD, Mayor, MB, Collier, JP 1987Potential errors inherent in quantitative densitometric analysis of orthopaedic radiographs. A study after total hip arthroplasty.J Bone Joint Surg Am695864PubMed West, JD, Mayor, MB, Collier, JP 1987Potential errors inherent in quantitative densitometric analysis of orthopaedic radiographs. A study after total hip arthroplasty.J Bone Joint Surg Am695864PubMed
10.
go back to reference Cohen, B, Rushton, N 1995Accuracy of DEXA measurement of bone mineral density after total hip arthroplasty.J Bone Joint Surg Br77479483PubMed Cohen, B, Rushton, N 1995Accuracy of DEXA measurement of bone mineral density after total hip arthroplasty.J Bone Joint Surg Br77479483PubMed
11.
go back to reference Kroger, H, Miettinen, H, Arnala, I, Koski, E, Rushton, N, Suomalainen, O 1996Evaluation of periprosthetic bone using dual-energy x-ray absorptiometry: precision of the method and effect of operation on bone mineral density.J Bone Miner Res1115261530PubMed Kroger, H, Miettinen, H, Arnala, I, Koski, E, Rushton, N, Suomalainen, O 1996Evaluation of periprosthetic bone using dual-energy x-ray absorptiometry: precision of the method and effect of operation on bone mineral density.J Bone Miner Res1115261530PubMed
12.
go back to reference Kalender, WA 1992Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography.Osteoporos Int28287PubMed Kalender, WA 1992Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography.Osteoporos Int28287PubMed
13.
go back to reference Cattermole, HC, Cunningham, JL 1995Influence of metallic implants adjacent to the measurement site on DEXA measurements: a phantom study.Phys Med Biol4018851896CrossRefPubMed Cattermole, HC, Cunningham, JL 1995Influence of metallic implants adjacent to the measurement site on DEXA measurements: a phantom study.Phys Med Biol4018851896CrossRefPubMed
14.
go back to reference Callaghan, JJ, Dysart, SH, Savory, CF, Hopkinson, WJ 1990Assessing the results of hip replacement. A comparison of five different rating systems.J Bone Joint Surg Br7210081009PubMed Callaghan, JJ, Dysart, SH, Savory, CF, Hopkinson, WJ 1990Assessing the results of hip replacement. A comparison of five different rating systems.J Bone Joint Surg Br7210081009PubMed
15.
go back to reference Spotorno, L, Romagnoli, S, Ivaldo, N, Grappiolo, G, Bibbiani, E, Blaha, DJ, Guen, TA 1993The CLS system. Theoretical concept and results.Acta Orthop Belg59144148PubMed Spotorno, L, Romagnoli, S, Ivaldo, N, Grappiolo, G, Bibbiani, E, Blaha, DJ, Guen, TA 1993The CLS system. Theoretical concept and results.Acta Orthop Belg59144148PubMed
16.
go back to reference Mortimer, ES, Rosenthall, L, Paterson, I, Bobyn, JD 1996Effect of rotation on periprosthetic bone mineral measurements in a hip phantom.Clin Orthop324269274PubMed Mortimer, ES, Rosenthall, L, Paterson, I, Bobyn, JD 1996Effect of rotation on periprosthetic bone mineral measurements in a hip phantom.Clin Orthop324269274PubMed
17.
go back to reference Gruen, TA, McNeice, GM, Amstutz, HC 1979“Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening.Clin Orthop1411727PubMed Gruen, TA, McNeice, GM, Amstutz, HC 1979“Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening.Clin Orthop1411727PubMed
18.
go back to reference Engh, CA, Bobyn, JD 1988The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty.Clin Orthop231728 Engh, CA, Bobyn, JD 1988The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty.Clin Orthop231728
19.
go back to reference Simank, HG, Brocai, DR, Reiser, D, Thomsen, M, Sabo, D, Lukoschek, M 1997Middle-term results of threaded acetabular cups. High failure rates five years after surgery.J Bone Joint Surg Br79366370CrossRefPubMed Simank, HG, Brocai, DR, Reiser, D, Thomsen, M, Sabo, D, Lukoschek, M 1997Middle-term results of threaded acetabular cups. High failure rates five years after surgery.J Bone Joint Surg Br79366370CrossRefPubMed
20.
go back to reference Kroger, H, Vanninen, E, Overmyer, M, Miettinen, H, Rushton, N, Suomalainen, O 1997Periprosthetic bone loss and regional bone turnover in uncemented total hip arthroplasty: a prospective study using high resolution single photon emission tomography and dual-energy X-ray absorptiometry.J Bone Miner Res12487492PubMed Kroger, H, Vanninen, E, Overmyer, M, Miettinen, H, Rushton, N, Suomalainen, O 1997Periprosthetic bone loss and regional bone turnover in uncemented total hip arthroplasty: a prospective study using high resolution single photon emission tomography and dual-energy X-ray absorptiometry.J Bone Miner Res12487492PubMed
21.
go back to reference Siebold, R, Scheller, G, Schreiner, U, Jani, L 2001Long-term results with the cement-free Spotorno CLS shaft.Orthopade30317322CrossRefPubMed Siebold, R, Scheller, G, Schreiner, U, Jani, L 2001Long-term results with the cement-free Spotorno CLS shaft.Orthopade30317322CrossRefPubMed
22.
go back to reference Aldinger, PR, Breusch, SJ, Lukoschek, M, Mau, H, Ewerbeck, V, Thomsen, M 200310-15 year follow-up of the cementless Spotorno stem.J Bone Joint Surg Br85 Bin press Aldinger, PR, Breusch, SJ, Lukoschek, M, Mau, H, Ewerbeck, V, Thomsen, M 200310-15 year follow-up of the cementless Spotorno stem.J Bone Joint Surg Br85 Bin press
23.
go back to reference Lofman, O, Larsson, L, Ross, I, Toss, G, Berglund, K 1997Bone mineral density in normal Swedish women.Bone20167174PubMed Lofman, O, Larsson, L, Ross, I, Toss, G, Berglund, K 1997Bone mineral density in normal Swedish women.Bone20167174PubMed
24.
go back to reference Kilgus, DJ, Shimaoka, EE, Tipton, JS, Eberle, RW 1993Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary results.J Bone Joint Surg Br75279287PubMed Kilgus, DJ, Shimaoka, EE, Tipton, JS, Eberle, RW 1993Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary results.J Bone Joint Surg Br75279287PubMed
25.
go back to reference McCarthy, CK, Steinberg, GG, Agren, M, Leahey, D, Wyman, E, Baran, DT 1991Quantifying bone loss from the proximal femur after total hip arthroplasty.J Bone Joint Surg Br73774778PubMed McCarthy, CK, Steinberg, GG, Agren, M, Leahey, D, Wyman, E, Baran, DT 1991Quantifying bone loss from the proximal femur after total hip arthroplasty.J Bone Joint Surg Br73774778PubMed
26.
go back to reference Carlsson, AS, Gentz, CF, Linder, L 1983Localized bone resorption in the femur in mechanical failure of cemented total hip arthroplasties.Acta Orthop Scand54396402PubMed Carlsson, AS, Gentz, CF, Linder, L 1983Localized bone resorption in the femur in mechanical failure of cemented total hip arthroplasties.Acta Orthop Scand54396402PubMed
27.
go back to reference Nevitt, MC, Lane, NE, Scott, JC, Hochberg, MC, Pressman, AR, Genant, HK, Cummings, SR 1995Radiographic osteoarthritis of the hip and bone mineral density. The Study of Osteoporotic Fractures Research Group.Arthritis Rheum38907916PubMed Nevitt, MC, Lane, NE, Scott, JC, Hochberg, MC, Pressman, AR, Genant, HK, Cummings, SR 1995Radiographic osteoarthritis of the hip and bone mineral density. The Study of Osteoporotic Fractures Research Group.Arthritis Rheum38907916PubMed
28.
go back to reference Doblare, M, Garcia, JM 2001Application of an anisotropic bone-remodelling model based on a damage-repair theory to the analysis of the proximal femur before and after total hip replacement.J Biomech3411571170CrossRefPubMed Doblare, M, Garcia, JM 2001Application of an anisotropic bone-remodelling model based on a damage-repair theory to the analysis of the proximal femur before and after total hip replacement.J Biomech3411571170CrossRefPubMed
29.
go back to reference Huiskes, R 1990The various stress patterns of press-fit, ingrown, and cemented femoral stems.Clin Orthop2612738PubMed Huiskes, R 1990The various stress patterns of press-fit, ingrown, and cemented femoral stems.Clin Orthop2612738PubMed
30.
go back to reference Huiskes, R, Weinans, H, Grootenboer, HJ, Dalstra, M, Fudala, B, Slooff, TJ 1987Adaptive bone-remodeling theory applied to prosthetic-design analysis.J Biomech2011351150PubMed Huiskes, R, Weinans, H, Grootenboer, HJ, Dalstra, M, Fudala, B, Slooff, TJ 1987Adaptive bone-remodeling theory applied to prosthetic-design analysis.J Biomech2011351150PubMed
31.
go back to reference Kerner, J, Huiskes, R, van Lenthe, GH, Weinans, H, van Rietbergen, B, Engh, CA, Amis, AA 1999Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling.J Biomech32695703CrossRefPubMed Kerner, J, Huiskes, R, van Lenthe, GH, Weinans, H, van Rietbergen, B, Engh, CA, Amis, AA 1999Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling.J Biomech32695703CrossRefPubMed
Metadata
Title
Pattern of Periprosthetic Bone Remodeling Around Stable Uncemented Tapered Hip Stems: A prospective 84-month follow-up study and a Median 156-month Cross-Sectional Study with DXA
Authors
P. R. Aldinger
D. Sabo
M. Pritsch
M. Thomsen
H. Mau
V. Ewerbeck
S. J. Breusch
Publication date
01-08-2003
Publisher
Springer-Verlag
Published in
Calcified Tissue International / Issue 2/2003
Print ISSN: 0171-967X
Electronic ISSN: 1432-0827
DOI
https://doi.org/10.1007/s00223-002-2036-z

Other articles of this Issue 2/2003

Calcified Tissue International 2/2003 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.