Abstract

Background

Dental implants emerge as a dependable and efficacious alternative for patients experiencing partial or complete tooth loss. The stability of these implants is influenced by surface topography and macro-level design. In cases where the height of the maxillary posterior region is diminished, employing short implants can prove advantageous. With the aim of examining the distribution of von Mises stress, strain, and micromovement in D4 bone quality surrounding platform-switched short implants, measuring 6 mm in length and featuring diameters ranging from 4 to 6 mm, as well as different thread designs, an in-depth finite element analysis was conducted under immediate loading conditions.

Methodology

A 3D finite element model was constructed to simulate maxillary molar crowns, incorporating an implant with a length of 6 mm and varying diameters and thread designs. The diameters utilized were 4/3.6 mm, 5/4 mm, and 6/4.8 mm, while the thread designs included buttress, square, and triangle patterns. Each model underwent analysis with a 100 N force applied in two directions: vertical and oblique, relative to the long axis of the implant. Stress, strain, and micromovement in the peri-implant region were recorded, employing the Ansys Workbench R v.18.1 software for modelling and analysis.

Results

When comparing all three diameters, the wide diameter (6 mm threads) exhibited the lowest values of peri-implant von Mises stresses (3.3 MPa and 35.1 MPa), strains (194 Ɛ and 484 Ɛ), and micromovements (0.7 μm and 1.3 Ɛ) subjected to axial and non-axial loading of a 100 N force. Notably, square microthreads yielded the most favorable stress parameters among the different thread shapes, manifesting the minimum values of stress, strains, and micromovements in their vicinity.

Conclusion

For the treatment of atrophic ridges or in scenarios necessitating extensive surgical preparation of the implant site, a combination of short implants, wide diameters, and platform switching can be employed. In situations with reduced bone height and the requirement for an implant-supported prosthesis to replace a missing permanent maxillary molar, the utilization of wide-diameter platform-switched short implants measuring 6 mm in length, featuring a square thread design, should be taken into consideration.
Literature
1.
go back to reference Sahin S, Cehreli MC, Yalcın E. The influence of functional forces on the biomechanics of implant-supported prostheses—a review. J Dent. 2002;30(7–8):271–82.PubMed Sahin S, Cehreli MC, Yalcın E. The influence of functional forces on the biomechanics of implant-supported prostheses—a review. J Dent. 2002;30(7–8):271–82.PubMed
2.
go back to reference Belser U, Buser D, Bernard JP. Implants in load carrying part of dentition. In: Lindhe J, Lang NP, Salvi G, editors. Textbook of Clinical Periodontology and Implant Dentistry. 5th ed. Copenhagen: Blackwell Munksgaard; 2008. p. 954–61. Belser U, Buser D, Bernard JP. Implants in load carrying part of dentition. In: Lindhe J, Lang NP, Salvi G, editors. Textbook of Clinical Periodontology and Implant Dentistry. 5th ed. Copenhagen: Blackwell Munksgaard; 2008. p. 954–61.
4.
go back to reference Lin C-L, Kuo Y-C, Lin T-S. Effects of dental implant length and bone quality on biomechanical responses in bone around implants: a 3-D non-linear finite element analysis. Biomed Eng Appl Basis Commum. 2005;17:44–9. Lin C-L, Kuo Y-C, Lin T-S. Effects of dental implant length and bone quality on biomechanical responses in bone around implants: a 3-D non-linear finite element analysis. Biomed Eng Appl Basis Commum. 2005;17:44–9.
5.
go back to reference Brunski JB. In vivo bone response to biomechanical loading at the bone/dental implant interface. Adv Dent Res. 1999;13:99–119.PubMed Brunski JB. In vivo bone response to biomechanical loading at the bone/dental implant interface. Adv Dent Res. 1999;13:99–119.PubMed
6.
go back to reference Kawahara H, Kawahara D, Hayakawa M, Tamai Y, Kuremoto T, Matsuda S. Osseointegration under immediate loading: biomechanical stress-strain and bone formation-resorption. Implant Dent. 2003;12:61–8.PubMed Kawahara H, Kawahara D, Hayakawa M, Tamai Y, Kuremoto T, Matsuda S. Osseointegration under immediate loading: biomechanical stress-strain and bone formation-resorption. Implant Dent. 2003;12:61–8.PubMed
7.
go back to reference Brunski JB. Biomechanical considerations in dental implant design. Int J Oral Implantol. 1988;5:31–4.PubMed Brunski JB. Biomechanical considerations in dental implant design. Int J Oral Implantol. 1988;5:31–4.PubMed
8.
go back to reference Hansson S. The implant neck: smooth or provided with retention elements. A biomechanical approach. Clin Oral Implants Res. 1999;10:394–405.PubMed Hansson S. The implant neck: smooth or provided with retention elements. A biomechanical approach. Clin Oral Implants Res. 1999;10:394–405.PubMed
9.
go back to reference Stacchi C, Lamazza L, Rapani A, Troiano G, Messina M, Antonelli A, Giudice A, Lombardi T. Marginal bone changes around platform-switched conical connection implants placed 1 or 2 mm subcrestally: A multicenter crossover randomized controlled trial. Clin Implant Dent Relat Res. 2023. epub ahead of print. https://doi.org/10.1111/cid.13186. Stacchi C, Lamazza L, Rapani A, Troiano G, Messina M, Antonelli A, Giudice A, Lombardi T. Marginal bone changes around platform-switched conical connection implants placed 1 or 2 mm subcrestally: A multicenter crossover randomized controlled trial. Clin Implant Dent Relat Res. 2023. epub ahead of print. https://​doi.​org/​10.​1111/​cid.​13186.
10.
go back to reference Lee DW, Choi YS, Park KH, Kim CS, Moon IS. Effect of microthread on the maintenance of marginal bone level: a 3-year prospective study. Clin Oral Implants Res. 2007;18:465–70.PubMed Lee DW, Choi YS, Park KH, Kim CS, Moon IS. Effect of microthread on the maintenance of marginal bone level: a 3-year prospective study. Clin Oral Implants Res. 2007;18:465–70.PubMed
11.
go back to reference Abrahamsson I, Berglundh T. Tissue characteristics at microthreaded implants: an experimental study in dogs. Clin Implant Dent Relat Res. 2006;8:107–13.PubMed Abrahamsson I, Berglundh T. Tissue characteristics at microthreaded implants: an experimental study in dogs. Clin Implant Dent Relat Res. 2006;8:107–13.PubMed
12.
go back to reference Kong L, Liu B, Li D, Song Y, Zhang A, Dang F, Qin X, Yang J. Comparative study of 12 thread shapes of dental implant designs: a three-dimensional finite element analysis. World J Model Simul. 2006;2:134–40. Kong L, Liu B, Li D, Song Y, Zhang A, Dang F, Qin X, Yang J. Comparative study of 12 thread shapes of dental implant designs: a three-dimensional finite element analysis. World J Model Simul. 2006;2:134–40.
13.
go back to reference Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2003;18:357–68.PubMed Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2003;18:357–68.PubMed
14.
go back to reference Rungsiyakull P, Rungsiyakull C, Monstaporn M, Sae-lee D, Elsaka S. Effects of bone type and occlusal loading pattern on bone remodeling in implant-supported single crown: a finite element study. J Prosthodont. 2023;1–9. https://doi.org/10.1111/jopr.13679. Rungsiyakull P, Rungsiyakull C, Monstaporn M, Sae-lee D, Elsaka S. Effects of bone type and occlusal loading pattern on bone remodeling in implant-supported single crown: a finite element study. J Prosthodont. 2023;1–9. https://​doi.​org/​10.​1111/​jopr.​13679.
15.
go back to reference Sevimay M, Turhan F, Kilicarslan MA, Eskitascioglu G. Three dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant supported crown. J Prosthet Dent. 2005;93:227–34.PubMed Sevimay M, Turhan F, Kilicarslan MA, Eskitascioglu G. Three dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant supported crown. J Prosthet Dent. 2005;93:227–34.PubMed
16.
go back to reference Ichikawa T, Kanitani H, Wigianto R, Kawamoto N, Matsumoto N. Influence of bone quality on the stress distribution. An in vitro experiment. Clin Oral Implants Res. 1997;8:18–22.PubMed Ichikawa T, Kanitani H, Wigianto R, Kawamoto N, Matsumoto N. Influence of bone quality on the stress distribution. An in vitro experiment. Clin Oral Implants Res. 1997;8:18–22.PubMed
18.
go back to reference Stacchi C, Troiano G, Montaruli G, Mozzati M, Lamazza L, Antonelli A, Giudice A, Lombardi T. Changes in implant stability using different site preparation techniques: osseodensification drills versus piezoelectric surgery. A multi-center prospective randomized controlled clinical trial. Clin Implant Dent Relat Res. 2023;25:133–40. https://doi.org/10.1111/cid.13140.CrossRefPubMed Stacchi C, Troiano G, Montaruli G, Mozzati M, Lamazza L, Antonelli A, Giudice A, Lombardi T. Changes in implant stability using different site preparation techniques: osseodensification drills versus piezoelectric surgery. A multi-center prospective randomized controlled clinical trial. Clin Implant Dent Relat Res. 2023;25:133–40. https://​doi.​org/​10.​1111/​cid.​13140.CrossRefPubMed
20.
go back to reference Udomsawat C, Rungsiyakull P, Rungsiyakull C, Khongkhuntian P. Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: a three-dimensional dynamic finite element study. Clin Experimental Dent Res. 2019;5:26–37. Udomsawat C, Rungsiyakull P, Rungsiyakull C, Khongkhuntian P. Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: a three-dimensional dynamic finite element study. Clin Experimental Dent Res. 2019;5:26–37.
21.
go back to reference Bell RB, Balkey GH, White RP, Hillebrand DG, Molina A. Staged reconstruction of the severely atrophic mandible with autogenous bone graft and endosteal implants. J Oral Maxillofac Surg. 2002;60:1135–41.PubMed Bell RB, Balkey GH, White RP, Hillebrand DG, Molina A. Staged reconstruction of the severely atrophic mandible with autogenous bone graft and endosteal implants. J Oral Maxillofac Surg. 2002;60:1135–41.PubMed
22.
go back to reference Wallace SS, Froum SJ. Effect of maxillary sinus augmentation on the survival of endosseous dental implants: a systematic review. Ann Periodontol. 2003;8:328–43.PubMed Wallace SS, Froum SJ. Effect of maxillary sinus augmentation on the survival of endosseous dental implants: a systematic review. Ann Periodontol. 2003;8:328–43.PubMed
24.
go back to reference Renouard F, Arnoux JP, Sarment DP. Five mm-diameter implants without a smooth surface collar: report on 98 consecutive placements. Int J Oral Maxillofac Implants. 1999;14:101–7.PubMed Renouard F, Arnoux JP, Sarment DP. Five mm-diameter implants without a smooth surface collar: report on 98 consecutive placements. Int J Oral Maxillofac Implants. 1999;14:101–7.PubMed
25.
go back to reference Lazzara RJ, Porter SS. Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent. 2006;26:9–17.PubMed Lazzara RJ, Porter SS. Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent. 2006;26:9–17.PubMed
26.
go back to reference Gardner DM. Platform switching as a means to achieving implant esthetics. N Y State Dent J. 2005;71:34–7.PubMed Gardner DM. Platform switching as a means to achieving implant esthetics. N Y State Dent J. 2005;71:34–7.PubMed
27.
go back to reference Vela-Nebot X, Rodriguez-Ciurana X, Rodado-Alonso C, Segala-Torres M. Benefits of an implant platform modification technique to reduce crestal bone resorption. Implant Dent. 2006;15:313–20.PubMed Vela-Nebot X, Rodriguez-Ciurana X, Rodado-Alonso C, Segala-Torres M. Benefits of an implant platform modification technique to reduce crestal bone resorption. Implant Dent. 2006;15:313–20.PubMed
28.
go back to reference Canullo L, Rasperini G. Preservation of peri-implant soft and hard tissues using platform switching of implants placed in immediate extraction sockets: a proof-of-concept study with 12- to 36-month follow-up. Int J Oral Maxillofac Implants. 2007;22:995–1000.PubMed Canullo L, Rasperini G. Preservation of peri-implant soft and hard tissues using platform switching of implants placed in immediate extraction sockets: a proof-of-concept study with 12- to 36-month follow-up. Int J Oral Maxillofac Implants. 2007;22:995–1000.PubMed
29.
go back to reference Hurzeler M, Fickl S, Zuhr O, Wachtel HC. Peri-implant bone level around implants with platform-switched abutments: preliminary data from a prospective study. J Oral Maxillofac Surg. 2007;65(Suppl 1):33–9.PubMed Hurzeler M, Fickl S, Zuhr O, Wachtel HC. Peri-implant bone level around implants with platform-switched abutments: preliminary data from a prospective study. J Oral Maxillofac Surg. 2007;65(Suppl 1):33–9.PubMed
30.
go back to reference Bidez MW, Misch CE. Clinical Biomechanics in Implant Dentistry. In: Misch CE, editor. Textbook on Dental Implant Prosthetics. 3rd ed. St. Louis: Mosby Publ.; 2005. p. 309–21. Bidez MW, Misch CE. Clinical Biomechanics in Implant Dentistry. In: Misch CE, editor. Textbook on Dental Implant Prosthetics. 3rd ed. St. Louis: Mosby Publ.; 2005. p. 309–21.
33.
go back to reference Rismanchian M, Birang R, Shahmoradi M, Talebi H, Zare RJ. Developing a new dental implant design and comparing its biomechanical features with four designs. Dent Res J. 2010;7:70–5. Rismanchian M, Birang R, Shahmoradi M, Talebi H, Zare RJ. Developing a new dental implant design and comparing its biomechanical features with four designs. Dent Res J. 2010;7:70–5.
35.
go back to reference Ammarullah MI, Santoso G, Sugiharto S, Supriyono T, Wibowo DB, Kurdi O, Tauviqirrahman M, Jamari J. Minimizing risk of failure from ceramic-on-ceramic total hip prosthesis by selecting ceramic materials based on Tresca stress. Sustainability. 2022;14:13413. https://doi.org/10.3390/su142013413.CrossRef Ammarullah MI, Santoso G, Sugiharto S, Supriyono T, Wibowo DB, Kurdi O, Tauviqirrahman M, Jamari J. Minimizing risk of failure from ceramic-on-ceramic total hip prosthesis by selecting ceramic materials based on Tresca stress. Sustainability. 2022;14:13413. https://​doi.​org/​10.​3390/​su142013413.CrossRef
36.
go back to reference Misch CE. Density of bone: Effect on treatment plans, surgical approach, healing, and progressive bone loading. Int J Oral Implantol. 1990;6:23–31.PubMed Misch CE. Density of bone: Effect on treatment plans, surgical approach, healing, and progressive bone loading. Int J Oral Implantol. 1990;6:23–31.PubMed
37.
go back to reference Kang N, Wu Y, Gong P, Yue L. A study of force distribution of loading stresses on implant bone interface on short implant length using 3-dimensional finite element analysis. J Oral Maxillofac Surg. 2008;118:519–23. Kang N, Wu Y, Gong P, Yue L. A study of force distribution of loading stresses on implant bone interface on short implant length using 3-dimensional finite element analysis. J Oral Maxillofac Surg. 2008;118:519–23.
38.
go back to reference Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent. 2001;85:585–98.PubMed Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent. 2001;85:585–98.PubMed
39.
go back to reference Paracchini L, Barbieri C, Redaelli M, Di Croce D, Vincenzi C, Guarnieri R. Finite element analysis of a New Dental Implant Design optimized for the desirable stress distribution in the surrounding bone region. Prosthesis. 2020;2:225–36. Paracchini L, Barbieri C, Redaelli M, Di Croce D, Vincenzi C, Guarnieri R. Finite element analysis of a New Dental Implant Design optimized for the desirable stress distribution in the surrounding bone region. Prosthesis. 2020;2:225–36.
40.
go back to reference Attanasio F, Antonelli A, Brancaccio Y, Averta F, Figliuzzi MM, Fortunato L, Giudice A. Primary Stability of three different osteotomy techniques in medullary bone: an in Vitro Study. Dent J. 2020;8:21. Attanasio F, Antonelli A, Brancaccio Y, Averta F, Figliuzzi MM, Fortunato L, Giudice A. Primary Stability of three different osteotomy techniques in medullary bone: an in Vitro Study. Dent J. 2020;8:21.
41.
go back to reference Alaqeely R, AlDosari M, Babay N, Abdulbari A, Ba Hadi A, Ben Yahia F, Abdulghani M. A 3D Finite Element Analysis Study of the Jawbones Response to Osseodensification and Conventional Drilling. In Proceedings of the ASME 2020 International Mechanical Engineering Congress and Exposition, Online, 16–19 November 2020. Volume 5: Biomedical and Biotechnology. https://doi.org/10.1115/IMECE2020-23669. Alaqeely R, AlDosari M, Babay N, Abdulbari A, Ba Hadi A, Ben Yahia F, Abdulghani M. A 3D Finite Element Analysis Study of the Jawbones Response to Osseodensification and Conventional Drilling. In Proceedings of the ASME 2020 International Mechanical Engineering Congress and Exposition, Online, 16–19 November 2020. Volume 5: Biomedical and Biotechnology. https://​doi.​org/​10.​1115/​IMECE2020-23669.
42.
go back to reference Raviv E, Turcotte A, Harel-Raviv M. Short dental implants in reduced alveolar bone height. Quintessence Int. 2010;41:575–9.PubMed Raviv E, Turcotte A, Harel-Raviv M. Short dental implants in reduced alveolar bone height. Quintessence Int. 2010;41:575–9.PubMed
43.
go back to reference Anitua E, Orive G, Aguirre JJ, Andía I. Five-year clinical evaluation of short dental implants placed in posterior areas: a retrospective study. J Periodontol. 2008;79:42–8.PubMed Anitua E, Orive G, Aguirre JJ, Andía I. Five-year clinical evaluation of short dental implants placed in posterior areas: a retrospective study. J Periodontol. 2008;79:42–8.PubMed
44.
go back to reference Comuzzi L, Tumedei M, Romasco T, Petrini M, Afrashtehfar KI, Inchingolo F, Piattelli A, Di Pietro N. Insertion torque, removal Torque, and resonance frequency analysis values of Ultrashort, Short, and Standard Dental Implants: an in Vitro Study on polyurethane foam sheets. J Funct Biomater. 2023;14:954–61. Comuzzi L, Tumedei M, Romasco T, Petrini M, Afrashtehfar KI, Inchingolo F, Piattelli A, Di Pietro N. Insertion torque, removal Torque, and resonance frequency analysis values of Ultrashort, Short, and Standard Dental Implants: an in Vitro Study on polyurethane foam sheets. J Funct Biomater. 2023;14:954–61.
45.
go back to reference Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. Success criteria and epidemiology. Eur J Oral Sci. 1998;106:527–51.PubMed Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. Success criteria and epidemiology. Eur J Oral Sci. 1998;106:527–51.PubMed
46.
go back to reference Okumura N, Stegaroiu R, Kitamura E, Kurokawa K, Nomura S. Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: a three-dimensional finite element analysis. J Prosthodont Res. 2010;54:133–42.PubMed Okumura N, Stegaroiu R, Kitamura E, Kurokawa K, Nomura S. Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: a three-dimensional finite element analysis. J Prosthodont Res. 2010;54:133–42.PubMed
47.
go back to reference Oliveira H, Brizuela Velasco A, Ríos-Santos J-V, Sánchez Lasheras F, Lemos BF, Gil FJ, Carvalho A, Herrero-Climent M. Effect of different Implant designs on strain and stress distribution under Non-Axial Loading: A three-dimensional finite element analysis. Int J Environ Res Public Health. 2020;17:4738.PubMedPubMedCentral Oliveira H, Brizuela Velasco A, Ríos-Santos J-V, Sánchez Lasheras F, Lemos BF, Gil FJ, Carvalho A, Herrero-Climent M. Effect of different Implant designs on strain and stress distribution under Non-Axial Loading: A three-dimensional finite element analysis. Int J Environ Res Public Health. 2020;17:4738.PubMedPubMedCentral
48.
go back to reference Buchs AU, Levine L, Moy P. Preliminary report of immediately loaded huinatural tooth replacement dental implants. Clin Implant Dent Relat Res. 2001;3:97–106.PubMed Buchs AU, Levine L, Moy P. Preliminary report of immediately loaded huinatural tooth replacement dental implants. Clin Implant Dent Relat Res. 2001;3:97–106.PubMed
49.
go back to reference Chow J, Hui E, Liu J, Li D, Wat P, Li W, Yau YK, Law H. The Hong Kong Bridge protocol. Immediate loading of mandibular Branemark fixtures using a fixed provisional prosthesis: preliminary results. Clin Implant Dent Relat Res. 2001;3:166–74.PubMed Chow J, Hui E, Liu J, Li D, Wat P, Li W, Yau YK, Law H. The Hong Kong Bridge protocol. Immediate loading of mandibular Branemark fixtures using a fixed provisional prosthesis: preliminary results. Clin Implant Dent Relat Res. 2001;3:166–74.PubMed
50.
go back to reference Grant JA, Bishop NE, Gotzen N, Sprecher C, Honl M, Morlock MM. Artificial composite bone as a model of human trabecular bone: the implant-bone interface. J Biomech. 2007;40:1158–64.PubMed Grant JA, Bishop NE, Gotzen N, Sprecher C, Honl M, Morlock MM. Artificial composite bone as a model of human trabecular bone: the implant-bone interface. J Biomech. 2007;40:1158–64.PubMed
51.
go back to reference Romeo E, Chisolfi M, Rozza R, Chiapasco M, Lops D. Short (8 mm) dental implants in the rehabilitation of partial and complete edentulism: a 3–14 year longitudinal study. Int J Prosthod. 2006;19:586–92. Romeo E, Chisolfi M, Rozza R, Chiapasco M, Lops D. Short (8 mm) dental implants in the rehabilitation of partial and complete edentulism: a 3–14 year longitudinal study. Int J Prosthod. 2006;19:586–92.
52.
go back to reference Maló P, Nobre MA, Rangert B. Short implants placed one-stage in maxillae and mandibles: a retrospective clinical study with 1 to 9 years of follow-up. Clin Oral Implants Res. 2007;9:15–21. Maló P, Nobre MA, Rangert B. Short implants placed one-stage in maxillae and mandibles: a retrospective clinical study with 1 to 9 years of follow-up. Clin Oral Implants Res. 2007;9:15–21.
53.
go back to reference Bruggenkate CM, Asikainen P, Foitzik C, Krekeler G, Sutter F. Short (6 mm) nonsubmerged dental implants: results of a multicenter clinical trial of 1 to 7 years. Int J Oral Maxillofac Implants. 1998;13:791–8.PubMed Bruggenkate CM, Asikainen P, Foitzik C, Krekeler G, Sutter F. Short (6 mm) nonsubmerged dental implants: results of a multicenter clinical trial of 1 to 7 years. Int J Oral Maxillofac Implants. 1998;13:791–8.PubMed
54.
go back to reference Deporter D, Ogiso B, Sohn D, Ruljancich K, Pharoahi M. Ultrashort Sintered PorousSurfaced Dental Implants used to replace posterior teeth. J Periodontol. 2008;79:1280–6.PubMed Deporter D, Ogiso B, Sohn D, Ruljancich K, Pharoahi M. Ultrashort Sintered PorousSurfaced Dental Implants used to replace posterior teeth. J Periodontol. 2008;79:1280–6.PubMed
55.
go back to reference Petrie CS, Williams JL. Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite element analysis. Clin Oral Implants Res. 2005;16:486–94.PubMed Petrie CS, Williams JL. Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite element analysis. Clin Oral Implants Res. 2005;16:486–94.PubMed
56.
go back to reference Himmlova L, Dostalova T, Kacovsky A, Konvickova S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent. 2004;91:20–5.PubMed Himmlova L, Dostalova T, Kacovsky A, Konvickova S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent. 2004;91:20–5.PubMed
57.
go back to reference Ding X, Liao SH, Zhu XH, Zhang XH, Zhang L. Effect of diameter and length on stress distribution of the alveolar crest around Immediate Loading Implants. Clin Implant Dent Relat Res. 2009;11:279–87.PubMed Ding X, Liao SH, Zhu XH, Zhang XH, Zhang L. Effect of diameter and length on stress distribution of the alveolar crest around Immediate Loading Implants. Clin Implant Dent Relat Res. 2009;11:279–87.PubMed
58.
go back to reference Kitamura E, Stegaroiu R, Nomura S, Miyakawa O. Biomechanical aspects of marginal bone resorption around osseointegrated implants considerations based on a three dimensional finite element analysis. Clin Oral Implants Res. 2004;15:401–12.PubMed Kitamura E, Stegaroiu R, Nomura S, Miyakawa O. Biomechanical aspects of marginal bone resorption around osseointegrated implants considerations based on a three dimensional finite element analysis. Clin Oral Implants Res. 2004;15:401–12.PubMed
59.
go back to reference Laney WR. Glossary of oral and maxillofacial implants, German Edition. Berlin, Germany: Quintessenz Verlags GmbH; 2008. p. 116. Laney WR. Glossary of oral and maxillofacial implants, German Edition. Berlin, Germany: Quintessenz Verlags GmbH; 2008. p. 116.
60.
go back to reference Anitua E, Tapia R, Luzuriaga F, Orive G. Influence of implant length, Diameter, & geometry on the stress distribution: a finite element analysis. Int J Period Rest Dent. 2010;30:89–95. Anitua E, Tapia R, Luzuriaga F, Orive G. Influence of implant length, Diameter, & geometry on the stress distribution: a finite element analysis. Int J Period Rest Dent. 2010;30:89–95.
61.
go back to reference Mosavar A, Ziaei A, Kadkhodaei M. The Effect of Implant Thread design on stress distribution in anisotropic bone with different osseointegration conditions: a finite element analysis. Int J Oral Maxillofac Implants. 2015;30:1317–26.PubMed Mosavar A, Ziaei A, Kadkhodaei M. The Effect of Implant Thread design on stress distribution in anisotropic bone with different osseointegration conditions: a finite element analysis. Int J Oral Maxillofac Implants. 2015;30:1317–26.PubMed
62.
go back to reference Chang PK, Chen YC, Huang CC, Lu WH, Chen YC, Tsai HH. Distribution of micromotion in implants and alveolar bone with different thread profiles in immediate loading: a finite element study. Int J Oral Maxillofac Implants. 2012;27:e96–e101.PubMed Chang PK, Chen YC, Huang CC, Lu WH, Chen YC, Tsai HH. Distribution of micromotion in implants and alveolar bone with different thread profiles in immediate loading: a finite element study. Int J Oral Maxillofac Implants. 2012;27:e96–e101.PubMed
63.
go back to reference Misch CE, Degidi M. Five-year prospective study of immediate/early loading of fixed prostheses in completely edentulous jaws with a bone quality-based implant system. Clin Implant Dent Relat Res. 2003;5:17–27.PubMed Misch CE, Degidi M. Five-year prospective study of immediate/early loading of fixed prostheses in completely edentulous jaws with a bone quality-based implant system. Clin Implant Dent Relat Res. 2003;5:17–27.PubMed
64.
go back to reference Sennerby L. Dental implants: matters of course and controversies. Periodontology. 2000;47:9–14. Sennerby L. Dental implants: matters of course and controversies. Periodontology. 2000;47:9–14.
65.
go back to reference Heboyan A, Lo Giudice R, Kalman L, Zafar MS, Tribst JPM. Stress distribution pattern in zygomatic implants supporting different superstructure materials. Materials. 2022;15:4953.PubMedPubMedCentral Heboyan A, Lo Giudice R, Kalman L, Zafar MS, Tribst JPM. Stress distribution pattern in zygomatic implants supporting different superstructure materials. Materials. 2022;15:4953.PubMedPubMedCentral
66.
go back to reference Kim WH, Lee J-C, Lim D, Heo Y-K, Song E-S, Lim Y-J, Kim B. Optimized Dental Implant Fixture Design for the desirable stress distribution in the surrounding bone region: a biomechanical analysis. Materials. 2019;12:2749.PubMedPubMedCentral Kim WH, Lee J-C, Lim D, Heo Y-K, Song E-S, Lim Y-J, Kim B. Optimized Dental Implant Fixture Design for the desirable stress distribution in the surrounding bone region: a biomechanical analysis. Materials. 2019;12:2749.PubMedPubMedCentral
Metadata
Title
Investigating the impact of diameters and thread designs on the Biomechanics of short implants placed in D4 bone: a 3D finite element analysis
Authors
Ali Robaian Alqahtani
Shrikar R. Desai
Jignesh R. Patel
Nasser Raqe Alqhtani
Abdullah Saad Alqahtani
Artak Heboyan
Gustavo V. O. Fernandes
Mohammed Mustafa
Mohamed Isaqali Karobari
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-03370-8

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue