Skip to main content
Top
Published in: Journal of Anesthesia 4/2021

01-08-2021 | Insulins | Clinical Report

Glucose control using an artificial pancreas in a severe COVID-19 patient on extracorporeal membrane oxygenation: a case report

Authors: Takuya Hinoue, Tomoaki Yatabe, Himuro Fujiwara, Osamu Nishida

Published in: Journal of Anesthesia | Issue 4/2021

Login to get access

Abstract

The usefulness and safety of continuous glucose monitoring (CGM) systems in adult patients with severe coronavirus disease (COVID-19) have been reported. Using CGM might reduce the exposure patients and healthcare workers to COVID-19 and limit the use of personal protective equipment during the pandemic. CGM devices measure glucose in the subcutaneous interstitial fluid, but the accuracy of this technique has not been established in critically ill patients. The artificial pancreas, STG-55 (Nikkiso, Tokyo), is a closed-loop device that conducts continuous blood glucose monitoring using a peripheral vein. We used the STG-55 for glucose control in a 60-year-old woman with severe COVID-19 admitted to the intensive care unit. Due to severe respiratory failure, the patient was intubated, and extracorporeal membrane oxygenation was introduced. Because she had hyperglycemia despite high-dose intravenous insulin therapy, we decided to use STG-55 for glucose control. The STG-55 safely titrated the insulin infusion and monitored glucose levels. Fifty-six hours after adopting the STG-55, it was removed because the blood sampling failed. No episodes of hypoglycemia were observed despite deep sedation during this period. In conclusion, this case demonstrates the potential utility of an artificial pancreas in patients with severe COVID-19.
Literature
1.
go back to reference Horby P, Lim WS, Emberson JR, Mafham M, Bell JL, Linsell L, Staplin N, Brightling C, Ustianowski A, Elamahi E, Prudon B, Green C, Felton T, Chadwick D, Rege K, Fegan C, Chappell LC, Faust SN, Jaki T, Jeffery K, Montgomery A, Rowan K, Juszczak E, Baillie K, Haynes R, Landray MJ. Dexamethasone in hospitalized patients with Covid-19. N Engl J Med. 2021;384:693–704.CrossRef Horby P, Lim WS, Emberson JR, Mafham M, Bell JL, Linsell L, Staplin N, Brightling C, Ustianowski A, Elamahi E, Prudon B, Green C, Felton T, Chadwick D, Rege K, Fegan C, Chappell LC, Faust SN, Jaki T, Jeffery K, Montgomery A, Rowan K, Juszczak E, Baillie K, Haynes R, Landray MJ. Dexamethasone in hospitalized patients with Covid-19. N Engl J Med. 2021;384:693–704.CrossRef
2.
go back to reference Zhu L, She ZG, Cheng X, Qin JJ, Zhang XJ, Cai J, Lei F, Wang H, Xie J, Wang W, Li H, Zhang P, Song X, Chen X, Xiang M, Zhang C, Bai L, Xiang D, Chen MM, Liu Y, Yan Y, Liu M, Mao W, Zou J, Liu L, Chen G, Luo P, Xiao B, Zhang C, Zhang Z, Lu Z, Wang J, Lu H, Xia X, Wang D, Liao X, Peng G, Ye P, Yang P, Yuan Y, Huang X, Guo J, Zhang BH, Li H. Association of Blood Glucose Control and Outcomes in Patients with COVID-19 and Pre-existing Type 2 Diabetes. Cell Metab. 2020;31:1068–77.CrossRef Zhu L, She ZG, Cheng X, Qin JJ, Zhang XJ, Cai J, Lei F, Wang H, Xie J, Wang W, Li H, Zhang P, Song X, Chen X, Xiang M, Zhang C, Bai L, Xiang D, Chen MM, Liu Y, Yan Y, Liu M, Mao W, Zou J, Liu L, Chen G, Luo P, Xiao B, Zhang C, Zhang Z, Lu Z, Wang J, Lu H, Xia X, Wang D, Liao X, Peng G, Ye P, Yang P, Yuan Y, Huang X, Guo J, Zhang BH, Li H. Association of Blood Glucose Control and Outcomes in Patients with COVID-19 and Pre-existing Type 2 Diabetes. Cell Metab. 2020;31:1068–77.CrossRef
3.
go back to reference Sadhu AR, Serrano IA, Xu J, T Nisar T, Lucier J, Pandya AR, Patham B. Continuous glucose monitoring in critically Ill patients with COVID-19: results of an emergent pilot study. J Diabetes Sci Technol. 2020;14:1065-73 Sadhu AR, Serrano IA, Xu J, T Nisar T, Lucier J, Pandya AR, Patham B. Continuous glucose monitoring in critically Ill patients with COVID-19: results of an emergent pilot study. J Diabetes Sci Technol. 2020;14:1065-73
4.
go back to reference Agarwal S, Mathew J, Davis GM, Shephardson A, Levine A, Louard R, Urrutia A, Perez-Guzman C, Umpierrez CE, Peng L, Pasquel FJ. Continuous glucose monitoring in the intensive care unit during the COVID-19 pandemic. Diabetes Care. 2021;44:847–9.CrossRef Agarwal S, Mathew J, Davis GM, Shephardson A, Levine A, Louard R, Urrutia A, Perez-Guzman C, Umpierrez CE, Peng L, Pasquel FJ. Continuous glucose monitoring in the intensive care unit during the COVID-19 pandemic. Diabetes Care. 2021;44:847–9.CrossRef
5.
go back to reference Davis GM, Faulds E, Walker T, Vigliotti D, Rabinovich M, Hester J, Peng L, McLean B, Hannon P, Poindexter N, Saunders P, Perez-Guzman C, Tekwani SS, Martin GS, Umpierrez G, Agarwal S, Dungan K, Pasquel FJ. Remote continuous glucose monitoring with a computerized insulin infusion protocol for critically Ill patients in a COVID-19 medical ICU: proof of concept. Diabetes Care. 2021;44:1055–8.CrossRef Davis GM, Faulds E, Walker T, Vigliotti D, Rabinovich M, Hester J, Peng L, McLean B, Hannon P, Poindexter N, Saunders P, Perez-Guzman C, Tekwani SS, Martin GS, Umpierrez G, Agarwal S, Dungan K, Pasquel FJ. Remote continuous glucose monitoring with a computerized insulin infusion protocol for critically Ill patients in a COVID-19 medical ICU: proof of concept. Diabetes Care. 2021;44:1055–8.CrossRef
6.
go back to reference Chow KW, Kelly DJ, Gupta R, Miller JD. Use of continuous glucose monitoring to assess parenteral nutrition-induced hyperglycemia in an adult patient with severe COVID-19. JPEN J Parenter Enteral Nutr. 2021;45:208–11.CrossRef Chow KW, Kelly DJ, Gupta R, Miller JD. Use of continuous glucose monitoring to assess parenteral nutrition-induced hyperglycemia in an adult patient with severe COVID-19. JPEN J Parenter Enteral Nutr. 2021;45:208–11.CrossRef
7.
go back to reference Ushigome E, Yamazaki M, Hamaguchi M, Ito T, Matsubara S, Tsuchido Y, Kasamatsu Y, Nakanishi M, Fujita N, Fukui M. Usefulness and safety of remote continuous glucose monitoring for a severe COVID-19 patient with diabetes. Diabetes Technol Ther. 2021;23:78–80.CrossRef Ushigome E, Yamazaki M, Hamaguchi M, Ito T, Matsubara S, Tsuchido Y, Kasamatsu Y, Nakanishi M, Fujita N, Fukui M. Usefulness and safety of remote continuous glucose monitoring for a severe COVID-19 patient with diabetes. Diabetes Technol Ther. 2021;23:78–80.CrossRef
8.
go back to reference Scrimgeour LA, Potz BA, Sellke FW, Abid MR. Continuous glucose monitoring in the cardiac ICU: current use and future directions. Clin Med Res (N Y). 2017;6:173–6.CrossRef Scrimgeour LA, Potz BA, Sellke FW, Abid MR. Continuous glucose monitoring in the cardiac ICU: current use and future directions. Clin Med Res (N Y). 2017;6:173–6.CrossRef
9.
go back to reference Tsukamoto Y, Kinoshita Y, Kitagawa H, Munekage M, Munekage E, Takezaki Y, Yatabe T, Yamashita K, Yamazaki R, Okabayashi T, Tarumi M, Kobayashi M, Mishina S, Hanazaki K. Evaluation of a novel artificial pancreas: closed loop glycemic control system with continuous blood glucose monitoring. Artif Organs. 2013;37:E67-73.CrossRef Tsukamoto Y, Kinoshita Y, Kitagawa H, Munekage M, Munekage E, Takezaki Y, Yatabe T, Yamashita K, Yamazaki R, Okabayashi T, Tarumi M, Kobayashi M, Mishina S, Hanazaki K. Evaluation of a novel artificial pancreas: closed loop glycemic control system with continuous blood glucose monitoring. Artif Organs. 2013;37:E67-73.CrossRef
10.
go back to reference U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health. Enforcement Policy for Non-Invasive Remote Monitoring Devices Used to Support Patient Monitoring During the Coronavirus Disease 2019 (COVID-19) Public Health Emergency (Revised) Guidance for Industry and Food and Drug Administration Staff. https://www.fda.gov/media/136290/download. Accessed June 14, 2021. U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health. Enforcement Policy for Non-Invasive Remote Monitoring Devices Used to Support Patient Monitoring During the Coronavirus Disease 2019 (COVID-19) Public Health Emergency (Revised) Guidance for Industry and Food and Drug Administration Staff. https://​www.​fda.​gov/​media/​136290/​download. Accessed June 14, 2021.
11.
go back to reference van Hooijdonk RT, Leopold JH, Winters T, Binnekade JM, Juffermans NP, Horn J, Fischer, van Dongen-Lases EC, Schultz MJ. Point accuracy and reliability of an interstitial continuous glucose-monitoring device in critically ill patients: a prospective study. Crit Care. 2015;19:34. van Hooijdonk RT, Leopold JH, Winters T, Binnekade JM, Juffermans NP, Horn J, Fischer, van Dongen-Lases EC, Schultz MJ. Point accuracy and reliability of an interstitial continuous glucose-monitoring device in critically ill patients: a prospective study. Crit Care. 2015;19:34.
12.
go back to reference Rhodes A, Evans LE, Alhazzani W, Levy MM, Antonelli M, Ferrer R, Kumar A, Sevransky JE, Sprung CL, Nunnally ME, Rochwerg B. Surviving sepsis campaign: international guidelines for management of sepsis and septic shock: 2016. Intensive Care Med. 2017;43:304–77.CrossRef Rhodes A, Evans LE, Alhazzani W, Levy MM, Antonelli M, Ferrer R, Kumar A, Sevransky JE, Sprung CL, Nunnally ME, Rochwerg B. Surviving sepsis campaign: international guidelines for management of sepsis and septic shock: 2016. Intensive Care Med. 2017;43:304–77.CrossRef
13.
go back to reference Nishida O, Ogura H, Egi M, Fujishima S, Hayashi Y, Iba T, Imaizumi H, Inoue S, Kakihana Y, Kotani J, Kushimoto S. The Japanese clinical practice guidelines for management of sepsis and septic shock 2016 (J-SSCG 2016). J Intensive Care. 2018;6:7.CrossRef Nishida O, Ogura H, Egi M, Fujishima S, Hayashi Y, Iba T, Imaizumi H, Inoue S, Kakihana Y, Kotani J, Kushimoto S. The Japanese clinical practice guidelines for management of sepsis and septic shock 2016 (J-SSCG 2016). J Intensive Care. 2018;6:7.CrossRef
14.
go back to reference Mibu K, Yatabe T, Yamasaki F, Kitagawa H, Munekage M, Namikawa T, Hanazaki K. Questionnaire survey on the use of a novel artificial pancreas by intensive care unit nurses. J Artif Organs. 2015;18:162–5.CrossRef Mibu K, Yatabe T, Yamasaki F, Kitagawa H, Munekage M, Namikawa T, Hanazaki K. Questionnaire survey on the use of a novel artificial pancreas by intensive care unit nurses. J Artif Organs. 2015;18:162–5.CrossRef
15.
go back to reference Aizawa K, Muraoka A, Kurumisawa S, Akutsu H, Sugaya A, Uesugi S, Kawahito K. Artificial endocrine pancreas with a closed-loop system effectively suppresses the accelerated hyperglycemic status after reperfusion during aortic surgery. Gen Thorac Cardiovasc Surg. 2021;69:14–8.CrossRef Aizawa K, Muraoka A, Kurumisawa S, Akutsu H, Sugaya A, Uesugi S, Kawahito K. Artificial endocrine pancreas with a closed-loop system effectively suppresses the accelerated hyperglycemic status after reperfusion during aortic surgery. Gen Thorac Cardiovasc Surg. 2021;69:14–8.CrossRef
16.
go back to reference Shin U, Naoko H, Michinori T, Yuya K, Yuka S, Yuki N, Motoharu K, Soichiro H, Mitsuo K, Yu Y, Tokito K, Satoru K, Kazuki D, Tetsuya O, Hirohisa M, Nobuhiko M, Takeshi O. Utility of bedside artificial pancreas for postoperative glycemic control in cardiac surgery. J Artif Organs. (in press) Shin U, Naoko H, Michinori T, Yuya K, Yuka S, Yuki N, Motoharu K, Soichiro H, Mitsuo K, Yu Y, Tokito K, Satoru K, Kazuki D, Tetsuya O, Hirohisa M, Nobuhiko M, Takeshi O. Utility of bedside artificial pancreas for postoperative glycemic control in cardiac surgery. J Artif Organs. (in press)
17.
go back to reference Mibu K, Yatabe T, Hanazaki K. Blood glucose control using an artificial pancreas reduces the workload of ICU nurses. J Artif Organs. 2012;15:71–6.CrossRef Mibu K, Yatabe T, Hanazaki K. Blood glucose control using an artificial pancreas reduces the workload of ICU nurses. J Artif Organs. 2012;15:71–6.CrossRef
18.
go back to reference Yatabe T, Yamazaki R, Kitagawa H, Okabayashi T, Yamashita K, Hanazaki K, Yokoyama M. The evaluation of the ability of closed-loop glycemic control device to maintain the blood glucose concentration in intensive care unit patients. Crit Care Med. 2011;39:575-8 Yatabe T, Yamazaki R, Kitagawa H, Okabayashi T, Yamashita K, Hanazaki K, Yokoyama M. The evaluation of the ability of closed-loop glycemic control device to maintain the blood glucose concentration in intensive care unit patients. Crit Care Med. 2011;39:575-8
Metadata
Title
Glucose control using an artificial pancreas in a severe COVID-19 patient on extracorporeal membrane oxygenation: a case report
Authors
Takuya Hinoue
Tomoaki Yatabe
Himuro Fujiwara
Osamu Nishida
Publication date
01-08-2021
Publisher
Springer Singapore
Published in
Journal of Anesthesia / Issue 4/2021
Print ISSN: 0913-8668
Electronic ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-021-02965-1

Other articles of this Issue 4/2021

Journal of Anesthesia 4/2021 Go to the issue