Skip to main content
Top
Published in: Journal of Artificial Organs 1/2012

01-03-2012 | Original Article

Blood glucose control using an artificial pancreas reduces the workload of ICU nurses

Authors: Kiyo Mibu, Tomoaki Yatabe, Kazuhiro Hanazaki

Published in: Journal of Artificial Organs | Issue 1/2012

Login to get access

Abstract

Blood glucose management is one of the important therapies in the intensive care unit (ICU). However, blood glucose management using the sliding-scale method increases the workload of ICU nurses. An artificial pancreas, STG-22, has been developed to continuously monitor blood glucose levels and to maintain them at appropriate levels. In this study, we examined the hypothesis that compared to conventional methods, blood glucose management using the STG-22 reduces the workload of ICU nurses and has a positive impact on awareness regarding the management of blood glucose. This study included 45 patients who underwent elective surgery and were treated at the ICU postoperatively. The patients were separated into the following two groups: (1) blood glucose was maintained using the STG-22 (AP group) and (2) blood glucose was maintained using the sliding-scale method (SS group). In addition, a questionnaire was developed for an awareness survey of ICU nurses (N = 20). The frequency of blood sampling and number of double checks were significantly lower in the AP group (1.3 ± 1.4 vs. 8.9 ± 8.1 times/admission, P < 0.001; 1.0 ± 1.4 vs. 9.8 ± 8.5 times/admission, P < 0.001). The time needed for glucose management per admission was significantly shorter in the AP group (9 ± 13 vs. 27 ± 24 min/admission; P = 0.003). Use of STG-22 for glucose management in the ICU increased the degree of attention given by nurses to glucose management and contributed to an improved sense of security. In conclusion, using the STG-22 in the ICU reduces the workload of ICU nurses compared to using the sliding-scale method. It also contributed to the reduction of the ICU nurses’ anxiety related to the management of blood glucose.
Literature
1.
go back to reference Lipshutz AKM, Gropper MA. Perioperative glycemic control. Anesthesiology. 2009;110:408–21.PubMed Lipshutz AKM, Gropper MA. Perioperative glycemic control. Anesthesiology. 2009;110:408–21.PubMed
2.
go back to reference Hanazaki K, Maeda H, Okabayashi T. Tight perioperative glycemic control using an artificial endocrine pancreas. Surg Today. 2010;40:1–7.PubMedCrossRef Hanazaki K, Maeda H, Okabayashi T. Tight perioperative glycemic control using an artificial endocrine pancreas. Surg Today. 2010;40:1–7.PubMedCrossRef
3.
go back to reference van den Berghe G, Wouters P, Weekers F, Verwaest C, Bruyninckx F, Schetz M, Vlasselaers D, Ferdinande P, Lauwers P, Bouillon R. Intensive insulin therapy in the critical ill patients. N Engl J Med. 2001;345:1359–67.PubMedCrossRef van den Berghe G, Wouters P, Weekers F, Verwaest C, Bruyninckx F, Schetz M, Vlasselaers D, Ferdinande P, Lauwers P, Bouillon R. Intensive insulin therapy in the critical ill patients. N Engl J Med. 2001;345:1359–67.PubMedCrossRef
4.
go back to reference Brunkhorst FM, Engel C, Bloos F, Meier-Hellmann A, Ragaller M, Weiler N, Moerer O, Gruendling M, Oppert M, Grond S, Olthoff D, Jaschinski U, John S, Rossaint R, Welte T, Schaefer M, Kern P, Kuhnt E, Kiehntopf M, Hartog C, Natanson C, Loeffler M, Reinhart K. German Competence Network Sepsis (SepNet) Intensive insulin therapy and pentastarch resuscitation in severe sepsis. N Engl J Med. 2008;358:125–39.PubMedCrossRef Brunkhorst FM, Engel C, Bloos F, Meier-Hellmann A, Ragaller M, Weiler N, Moerer O, Gruendling M, Oppert M, Grond S, Olthoff D, Jaschinski U, John S, Rossaint R, Welte T, Schaefer M, Kern P, Kuhnt E, Kiehntopf M, Hartog C, Natanson C, Loeffler M, Reinhart K. German Competence Network Sepsis (SepNet) Intensive insulin therapy and pentastarch resuscitation in severe sepsis. N Engl J Med. 2008;358:125–39.PubMedCrossRef
5.
go back to reference NICE-SUGAR study investigators. Intensive versus conventional glucose control in critically ill patients. N Engl J Med. 2009;360:1283–97. NICE-SUGAR study investigators. Intensive versus conventional glucose control in critically ill patients. N Engl J Med. 2009;360:1283–97.
6.
go back to reference Bellomo R, Egi M. What is a NICE-SUGAR for patients in the intensive care unit? Mayo Clin Proc. 2009;84:400–2.PubMed Bellomo R, Egi M. What is a NICE-SUGAR for patients in the intensive care unit? Mayo Clin Proc. 2009;84:400–2.PubMed
7.
go back to reference Okabayashi T, Nishimori I, Maeda H, Yamashita K, Yatabe T, Hanazaki K. Effect of intensive insulin therapy using a closed-loop glycemic control system in hepatic resection patients: a prospective randomized clinical trial. Diabetes Care. 2009;32:1425–7.PubMedCrossRef Okabayashi T, Nishimori I, Maeda H, Yamashita K, Yatabe T, Hanazaki K. Effect of intensive insulin therapy using a closed-loop glycemic control system in hepatic resection patients: a prospective randomized clinical trial. Diabetes Care. 2009;32:1425–7.PubMedCrossRef
8.
go back to reference Garrouste-Orgeas M, Timsit JF, Vesin A, Schwebel C, Arnodo P, Lefrant JY, Souweine B, Tabah A, Charpentier J, Gontier O, Fieux F, Mourvillier B, Troché G, Reignier J, Dumay MF, Azoulay E, Reignier B, Carlet J, Soufir L, OUTCOMEREA Study Group. Selected medical errors in the intensive care unit: results of the IATROREF study: parts I and II. Am J Respir Crit Care Med. 2010;181:134–42.PubMedCrossRef Garrouste-Orgeas M, Timsit JF, Vesin A, Schwebel C, Arnodo P, Lefrant JY, Souweine B, Tabah A, Charpentier J, Gontier O, Fieux F, Mourvillier B, Troché G, Reignier J, Dumay MF, Azoulay E, Reignier B, Carlet J, Soufir L, OUTCOMEREA Study Group. Selected medical errors in the intensive care unit: results of the IATROREF study: parts I and II. Am J Respir Crit Care Med. 2010;181:134–42.PubMedCrossRef
9.
go back to reference Yatabe T, Yamazaki R, Kitagawa H, Okabayashi T, Yamashita K, Hanazaki K, Yokoyama M. The evaluation of the ability of closed loop glycemic control device to maintain the blood glucose concentration in ICU patients. Crit Care Med. 2011;39:575–8.PubMedCrossRef Yatabe T, Yamazaki R, Kitagawa H, Okabayashi T, Yamashita K, Hanazaki K, Yokoyama M. The evaluation of the ability of closed loop glycemic control device to maintain the blood glucose concentration in ICU patients. Crit Care Med. 2011;39:575–8.PubMedCrossRef
10.
go back to reference Yamashita K, Okabayashi T, Yokoyama T, Yatabe T, Maeda H, Manabe M, Hanazaki K. The accuracy of a continuous blood glucose monitor during surgery. Anesth Analg. 2008;106:160–3.PubMedCrossRef Yamashita K, Okabayashi T, Yokoyama T, Yatabe T, Maeda H, Manabe M, Hanazaki K. The accuracy of a continuous blood glucose monitor during surgery. Anesth Analg. 2008;106:160–3.PubMedCrossRef
11.
go back to reference Okabayashi T, Hanazaki K, Nishimori I, Sugimoto T, Maeda H, Yatabe T, Dabanaka K, Kobayashi M, Yamashita K. Continuous post-operative blood glucose monitoring and control using a closed-loop system in patients undergoing hepatic resection. Dig Dis Sci. 2007;53:1405–10.PubMedCrossRef Okabayashi T, Hanazaki K, Nishimori I, Sugimoto T, Maeda H, Yatabe T, Dabanaka K, Kobayashi M, Yamashita K. Continuous post-operative blood glucose monitoring and control using a closed-loop system in patients undergoing hepatic resection. Dig Dis Sci. 2007;53:1405–10.PubMedCrossRef
12.
go back to reference Dellinger RP, Levy MM, Carlet JM, Bion J, Parker MM, Jaeschke R, Reinhart K, Angus DC, Brun-Buisson C, Beale R, Calandra T, Dhainaut JF, Gerlach H, Harvey M, Marini JJ, Marshall J, Ranieri M, Ramsay G, Sevransky J, Thompson BT, Townsend S, Vender JS, Zimmerman JL, Vincent JL. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock. Crit Care Med. 2008;36:296–327.PubMedCrossRef Dellinger RP, Levy MM, Carlet JM, Bion J, Parker MM, Jaeschke R, Reinhart K, Angus DC, Brun-Buisson C, Beale R, Calandra T, Dhainaut JF, Gerlach H, Harvey M, Marini JJ, Marshall J, Ranieri M, Ramsay G, Sevransky J, Thompson BT, Townsend S, Vender JS, Zimmerman JL, Vincent JL. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock. Crit Care Med. 2008;36:296–327.PubMedCrossRef
13.
go back to reference Lee A, Faddoul B, Sowan A, Johnson KL, Silver KD, Vaidya V. Computerisation of a paper-based intravenous insulin protocol reduces errors in a prospective crossover simulated tight glycaemic control study. Intensive Crit Care Nurs. 2010;26:161–8.PubMedCrossRef Lee A, Faddoul B, Sowan A, Johnson KL, Silver KD, Vaidya V. Computerisation of a paper-based intravenous insulin protocol reduces errors in a prospective crossover simulated tight glycaemic control study. Intensive Crit Care Nurs. 2010;26:161–8.PubMedCrossRef
14.
go back to reference Valentin A, Capuzzo M, Guidet B, Moreno R, Metnitz B, Bauer P, Metnitz P; Research Group on Quality Improvement of the European Society of Intensive Care Medicine (ESICM); Sentinel Events Evaluation (SEE) Study Investigators. Errors in administration of parenteral drugs in intensive care units. multinational prospective study. BMJ. 2009;338:b814. Valentin A, Capuzzo M, Guidet B, Moreno R, Metnitz B, Bauer P, Metnitz P; Research Group on Quality Improvement of the European Society of Intensive Care Medicine (ESICM); Sentinel Events Evaluation (SEE) Study Investigators. Errors in administration of parenteral drugs in intensive care units. multinational prospective study. BMJ. 2009;338:b814.
Metadata
Title
Blood glucose control using an artificial pancreas reduces the workload of ICU nurses
Authors
Kiyo Mibu
Tomoaki Yatabe
Kazuhiro Hanazaki
Publication date
01-03-2012
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 1/2012
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-011-0611-7

Other articles of this Issue 1/2012

Journal of Artificial Organs 1/2012 Go to the issue