Skip to main content
Top
Published in: BMC Oral Health 1/2023

Open Access 01-12-2023 | Research

Influence of a new abutment design concept on the biomechanics of peri-implant bone, implant components, and microgap formation: a finite element analysis

Authors: Huimin Nie, Yantai Tang, Yan Yang, Weijie Wu, Wenjuan Zhou, Zhonghao Liu

Published in: BMC Oral Health | Issue 1/2023

Login to get access

Abstract

Background

A new two-piece abutment design consisting of an upper prosthetic component and tissue-level base has been introduced; however, the biomechanical behavior of such a design has not been documented. This study aimed to investigate the effect of a two-piece abutment design on the stress in the implant components and surrounding bone, as well as its influence on microgap formation.

Methods

To simulate the implant models in the mandibular left first molar area, we established nine experimental groups that included three bone qualities (type II, III, and IV) and three implant–abutment designs (internal bone level, tissue level, and a two-piece design). After the screw was preloaded, the maximum occlusal (600 N) and masticatory (225 N) forces were established. Finite element analysis was performed to analyze the maximum and minimum principal stresses on the peri-implant bone; the von Mises stresses in the implants, abutments, bases, and screws, and the microgaps at the implant–abutment, implant–base, and base–abutment interfaces.

Results

For all three loading methods, the two-piece abutment design and bone-level connection exhibited similarities in the maximum and minimum principal stresses in the peri-implant bone. The von Mises stresses in both screws and bases were greater for the two-piece design than for the other connection types. The smallest microgap was detected in the tissue-level connection; the largest was observed at the implant–base interface in the two-piece design.

Conclusions

The present study found no evidence that the abutment design exerts a significant effect on peri-implant bone stress. However, the mechanical effects associated with the base and screws should be noted when using a two-piece abutment design. The two-piece abutment design also had no advantage in eliminating the microgap.
Literature
1.
go back to reference Vetromilla BM, Brondani LP, Pereira-Cenci T, Bergoli CD. Influence of different implant-abutment connection designs on the mechanical and biological behavior of single-tooth implants in the maxillary esthetic zone: a systematic review. J Prosthet Dent. 2019;121(3):398-403.e3.CrossRefPubMed Vetromilla BM, Brondani LP, Pereira-Cenci T, Bergoli CD. Influence of different implant-abutment connection designs on the mechanical and biological behavior of single-tooth implants in the maxillary esthetic zone: a systematic review. J Prosthet Dent. 2019;121(3):398-403.e3.CrossRefPubMed
2.
go back to reference Koutouzis T. Implant-abutment connection as contributing factor to peri-implant diseases. Periodontol 2000. 2019;81(1):152–66.CrossRefPubMed Koutouzis T. Implant-abutment connection as contributing factor to peri-implant diseases. Periodontol 2000. 2019;81(1):152–66.CrossRefPubMed
3.
go back to reference Lemos CAA, Verri FR, Bonfante EA, Santiago Júnior JF, Pellizzer EP. Comparison of external and internal implant-abutment connections for implant supported prostheses. a systematic review and meta-analysis. J Dent. 2018;70:14–22.CrossRefPubMed Lemos CAA, Verri FR, Bonfante EA, Santiago Júnior JF, Pellizzer EP. Comparison of external and internal implant-abutment connections for implant supported prostheses. a systematic review and meta-analysis. J Dent. 2018;70:14–22.CrossRefPubMed
4.
go back to reference Lee H, Jo M, Noh G. Biomechanical effects of dental implant diameter, connection type, and bone density on microgap formation and fatigue failure: a finite element analysis. Comput Methods Programs Biomed. 2021;200: 105863.CrossRefPubMed Lee H, Jo M, Noh G. Biomechanical effects of dental implant diameter, connection type, and bone density on microgap formation and fatigue failure: a finite element analysis. Comput Methods Programs Biomed. 2021;200: 105863.CrossRefPubMed
5.
go back to reference Lee H, Park S, Noh G. Biomechanical analysis of 4 types of short dental implants in a resorbed mandible. J Prosthet Dent. 2019;121(4):659–70.CrossRefPubMed Lee H, Park S, Noh G. Biomechanical analysis of 4 types of short dental implants in a resorbed mandible. J Prosthet Dent. 2019;121(4):659–70.CrossRefPubMed
6.
go back to reference Lee H, Jo M, Sailer I, Noh G. Effects of implant diameter, implant-abutment connection type, and bone density on the biomechanical stability of implant components and bone: a finite element analysis study. J Prosthet Dent. 2022;128(4):716–28.CrossRefPubMed Lee H, Jo M, Sailer I, Noh G. Effects of implant diameter, implant-abutment connection type, and bone density on the biomechanical stability of implant components and bone: a finite element analysis study. J Prosthet Dent. 2022;128(4):716–28.CrossRefPubMed
7.
go back to reference Kim JH, Noh G, Hong SJ, Lee H. Biomechanical stress and microgap analysis of bone-level and tissue-level implant abutment structure according to the five different directions of occlusal loads. J Adv Prosthodont. 2020;12(5):316–21.CrossRefPubMedPubMedCentral Kim JH, Noh G, Hong SJ, Lee H. Biomechanical stress and microgap analysis of bone-level and tissue-level implant abutment structure according to the five different directions of occlusal loads. J Adv Prosthodont. 2020;12(5):316–21.CrossRefPubMedPubMedCentral
8.
go back to reference Qian J, Wennerberg A, Albrektsson T. Reasons for marginal bone loss around oral implants. Clin Implant Dent Relat Res. 2012;14(6):792–807.CrossRefPubMed Qian J, Wennerberg A, Albrektsson T. Reasons for marginal bone loss around oral implants. Clin Implant Dent Relat Res. 2012;14(6):792–807.CrossRefPubMed
9.
go back to reference Broggini N, McManus LM, Hermann JS, Medina R, Schenk RK, Buser D, Cochran DL. Peri-implant inflammation defined by the implant-abutment interface. J Dent Res. 2006;85(5):473–8.CrossRefPubMed Broggini N, McManus LM, Hermann JS, Medina R, Schenk RK, Buser D, Cochran DL. Peri-implant inflammation defined by the implant-abutment interface. J Dent Res. 2006;85(5):473–8.CrossRefPubMed
10.
go back to reference Pellizzer EP, Lemos CAA, Almeida DAF, de Souza Batista VE, Santiago Júnior JF, Verri FR. Biomechanical analysis of different implant-abutments interfaces in different bone types: an in silico analysis. Mater Sci Eng C Mater Biol Appl. 2018;90:645–50.CrossRefPubMed Pellizzer EP, Lemos CAA, Almeida DAF, de Souza Batista VE, Santiago Júnior JF, Verri FR. Biomechanical analysis of different implant-abutments interfaces in different bone types: an in silico analysis. Mater Sci Eng C Mater Biol Appl. 2018;90:645–50.CrossRefPubMed
11.
go back to reference Lemos CAA, Verri FR, Noritomi PY, Kemmoku DT, Souza Batista VE, Cruz RS, de Luna Gomes JM, Pellizzer EP. Effect of bone quality and bone loss level around internal and external connection implants: a finite element analysis study. J Prosthet Dent. 2021;125(1):137.e1-137.e10.CrossRefPubMed Lemos CAA, Verri FR, Noritomi PY, Kemmoku DT, Souza Batista VE, Cruz RS, de Luna Gomes JM, Pellizzer EP. Effect of bone quality and bone loss level around internal and external connection implants: a finite element analysis study. J Prosthet Dent. 2021;125(1):137.e1-137.e10.CrossRefPubMed
12.
go back to reference Santiago Junior JF, Verri FR, Almeida DA, de Souza Batista VE, Lemos CA, Pellizzer EP. Finite element analysis on influence of implant surface treatments, connection and bone types. Mater Sci Eng C Mater Biol Appl. 2016;63:292–300.CrossRefPubMed Santiago Junior JF, Verri FR, Almeida DA, de Souza Batista VE, Lemos CA, Pellizzer EP. Finite element analysis on influence of implant surface treatments, connection and bone types. Mater Sci Eng C Mater Biol Appl. 2016;63:292–300.CrossRefPubMed
13.
go back to reference Araki H, Nakano T, Ono S, Yatani H. Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials. Int J Implant Dent. 2020;6(1):5.CrossRefPubMedPubMedCentral Araki H, Nakano T, Ono S, Yatani H. Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials. Int J Implant Dent. 2020;6(1):5.CrossRefPubMedPubMedCentral
14.
go back to reference Avağ C, Akkocaoğlu M. The evaluation of stress on bone level and tissue level short implants: a finite element analysis (FEA) study. J Stomatol Oral Maxillofac Surg. 2023;124(1S): 101298.CrossRefPubMed Avağ C, Akkocaoğlu M. The evaluation of stress on bone level and tissue level short implants: a finite element analysis (FEA) study. J Stomatol Oral Maxillofac Surg. 2023;124(1S): 101298.CrossRefPubMed
15.
go back to reference Matsuoka T, Nakano T, Yamaguchi S, Ono S, Watanabe S, Sato T, Yatani H. Effects of implant-abutment connection type and inter-implant distance on inter-implant bone stress and microgap: three-dimensional finite element analysis. Materials (Basel). 2021;14(9):2421.CrossRefPubMed Matsuoka T, Nakano T, Yamaguchi S, Ono S, Watanabe S, Sato T, Yatani H. Effects of implant-abutment connection type and inter-implant distance on inter-implant bone stress and microgap: three-dimensional finite element analysis. Materials (Basel). 2021;14(9):2421.CrossRefPubMed
16.
go back to reference Pessoa RS, Muraru L, Júnior EM, Vaz LG, Sloten JV, Duyck J, Jaecques SV. Influence of implant connection type on the biomechanical environment of immediately placed implants - CT-based nonlinear, three-dimensional finite element analysis. Clin Implant Dent Relat Res. 2010;12(3):219–34.PubMed Pessoa RS, Muraru L, Júnior EM, Vaz LG, Sloten JV, Duyck J, Jaecques SV. Influence of implant connection type on the biomechanical environment of immediately placed implants - CT-based nonlinear, three-dimensional finite element analysis. Clin Implant Dent Relat Res. 2010;12(3):219–34.PubMed
17.
go back to reference Siebert C, Rieder D, Eggert J, Wichmann MG, Heckmann SM. Long-term esthetic outcome of tissue-level and bone-level implants in the anterior maxilla. Int J Oral Maxillofac Implants. 2018;33(4):905–12.CrossRefPubMed Siebert C, Rieder D, Eggert J, Wichmann MG, Heckmann SM. Long-term esthetic outcome of tissue-level and bone-level implants in the anterior maxilla. Int J Oral Maxillofac Implants. 2018;33(4):905–12.CrossRefPubMed
18.
go back to reference Studenikin R. Prosthodontics using removable platform switching technologies (Multiunit, On1) as exemplified by conical connection implant systems for early and immediate loading. Int J Dent. 2021;2021:6633804.CrossRefPubMedPubMedCentral Studenikin R. Prosthodontics using removable platform switching technologies (Multiunit, On1) as exemplified by conical connection implant systems for early and immediate loading. Int J Dent. 2021;2021:6633804.CrossRefPubMedPubMedCentral
19.
go back to reference Rompen E, Fabbri G, Staas T, Valantiejiene V, Linkevicius T. Clinical investigation of the On1 two-piece abutment concept preliminary results. Clin Oral Implants Res. 2008;29(Suppl. 17):319–319. Rompen E, Fabbri G, Staas T, Valantiejiene V, Linkevicius T. Clinical investigation of the On1 two-piece abutment concept preliminary results. Clin Oral Implants Res. 2008;29(Suppl. 17):319–319.
20.
go back to reference Fabbri G, Staas T, Linkevicius T, Valantiejiene V, González-Martin O, Rompen E. Clinical performance of a Novel two-piece abutment concept: results from a prospective study with a 1-year follow-up. J Clin Med. 2021;10(8):1594.CrossRefPubMedPubMedCentral Fabbri G, Staas T, Linkevicius T, Valantiejiene V, González-Martin O, Rompen E. Clinical performance of a Novel two-piece abutment concept: results from a prospective study with a 1-year follow-up. J Clin Med. 2021;10(8):1594.CrossRefPubMedPubMedCentral
21.
go back to reference Lambrechts T, Doornewaard R, De Bruyckere T, Matthijs L, Deschepper E, Cosyn J. A multicenter cohort study on the association of the one-abutment one-time concept with marginal bone loss around bone level implants. Clin Oral Implants Res. 2021;32(2):192–202.CrossRefPubMed Lambrechts T, Doornewaard R, De Bruyckere T, Matthijs L, Deschepper E, Cosyn J. A multicenter cohort study on the association of the one-abutment one-time concept with marginal bone loss around bone level implants. Clin Oral Implants Res. 2021;32(2):192–202.CrossRefPubMed
22.
go back to reference Staedt H, Rossa M, Lehmann KM, Al-Nawas B, Kämmerer PW, Heimes D. Potential risk factors for early and late dental implant failure: a retrospective clinical study on 9080 implants. Int J Implant Dent. 2020;6(1):81.CrossRefPubMedPubMedCentral Staedt H, Rossa M, Lehmann KM, Al-Nawas B, Kämmerer PW, Heimes D. Potential risk factors for early and late dental implant failure: a retrospective clinical study on 9080 implants. Int J Implant Dent. 2020;6(1):81.CrossRefPubMedPubMedCentral
23.
go back to reference Liu C, Xing Y, Li Y, Lin Y, Xu J, Wu D. Bone quality effect on short implants in the edentulous mandible: a finite element study. BMC Oral Health. 2022;22(1):139.CrossRefPubMedPubMedCentral Liu C, Xing Y, Li Y, Lin Y, Xu J, Wu D. Bone quality effect on short implants in the edentulous mandible: a finite element study. BMC Oral Health. 2022;22(1):139.CrossRefPubMedPubMedCentral
24.
go back to reference Kitagawa T, Tanimoto Y, Odaki M, Nemoto K, Aida M. Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system. J Biomed Mater Res B Appl Biomater. 2005;75(2):457–63.CrossRefPubMed Kitagawa T, Tanimoto Y, Odaki M, Nemoto K, Aida M. Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system. J Biomed Mater Res B Appl Biomater. 2005;75(2):457–63.CrossRefPubMed
25.
go back to reference Tang CB, Liul SY, Zhou GX, Yu JH, Zhang GD, Bao YD, Wang QJ. Nonlinear finite element analysis of three implant- abutment interface designs. Int J Oral Sci. 2012;4(2):101–8.CrossRefPubMedPubMedCentral Tang CB, Liul SY, Zhou GX, Yu JH, Zhang GD, Bao YD, Wang QJ. Nonlinear finite element analysis of three implant- abutment interface designs. Int J Oral Sci. 2012;4(2):101–8.CrossRefPubMedPubMedCentral
26.
go back to reference Wu T, Fan H, Ma R, Chen H, Li Z, Yu H. Effect of lubricant on the reliability of dental implant abutment screw joint: an in vitro laboratory and three-dimension finite element analysis. Mater Sci Eng C Mater Biol Appl. 2017;75:297–304.CrossRefPubMed Wu T, Fan H, Ma R, Chen H, Li Z, Yu H. Effect of lubricant on the reliability of dental implant abutment screw joint: an in vitro laboratory and three-dimension finite element analysis. Mater Sci Eng C Mater Biol Appl. 2017;75:297–304.CrossRefPubMed
27.
go back to reference Liu Y, Gao S, Han Y, Yang Q, Arola D, Zhang D. Bearing capacity of ceramic crowns before and after cyclic loading: an in vitro study. J Mech Behav Biomed Mater. 2018;87:197–204.CrossRefPubMed Liu Y, Gao S, Han Y, Yang Q, Arola D, Zhang D. Bearing capacity of ceramic crowns before and after cyclic loading: an in vitro study. J Mech Behav Biomed Mater. 2018;87:197–204.CrossRefPubMed
28.
go back to reference Barbier L, Vander Sloten J, Krzesinski G, Schepers E, Van der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil. 1998;25(11):847–58.CrossRefPubMed Barbier L, Vander Sloten J, Krzesinski G, Schepers E, Van der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil. 1998;25(11):847–58.CrossRefPubMed
29.
go back to reference Faverani LP, Barão VA, Ramalho-Ferreira G, Delben JA, Ferreira MB, Garcia Júnior IR, Assunção WG. The influence of bone quality on the biomechanical behavior of full-arch implant-supported fixed prostheses. Mater Sci Eng C Mater Biol Appl. 2014;37:164–70.CrossRefPubMed Faverani LP, Barão VA, Ramalho-Ferreira G, Delben JA, Ferreira MB, Garcia Júnior IR, Assunção WG. The influence of bone quality on the biomechanical behavior of full-arch implant-supported fixed prostheses. Mater Sci Eng C Mater Biol Appl. 2014;37:164–70.CrossRefPubMed
30.
go back to reference Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2003;18(3):357–68.PubMed Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2003;18(3):357–68.PubMed
31.
go back to reference D’Souza KM, Aras MA. Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials. J Indian Prosthodont Soc. 2017;17(1):53–60. D’Souza KM, Aras MA. Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials. J Indian Prosthodont Soc. 2017;17(1):53–60.
32.
go back to reference Pumnil S, Rungsiyakull P, Rungsiyakull C, Elsaka S. Effect of different customized abutment types on stress distribution in implant-supported single crown: a 3D finite element analysis. J Prosthodont. 2022;31(5):e2–11.CrossRefPubMed Pumnil S, Rungsiyakull P, Rungsiyakull C, Elsaka S. Effect of different customized abutment types on stress distribution in implant-supported single crown: a 3D finite element analysis. J Prosthodont. 2022;31(5):e2–11.CrossRefPubMed
33.
go back to reference Zipprich H, Weigl P, Ratka C, Lange B, Lauer HC. The micromechanical behavior of implant-abutment connections under a dynamic load protocol. Clin Implant Dent Relat Res. 2018;20(5):814–23.CrossRefPubMed Zipprich H, Weigl P, Ratka C, Lange B, Lauer HC. The micromechanical behavior of implant-abutment connections under a dynamic load protocol. Clin Implant Dent Relat Res. 2018;20(5):814–23.CrossRefPubMed
34.
go back to reference Rack A, Rack T, Stiller M, Riesemeier H, Zabler S, Nelson K. In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants. J Synchrotron Radiat. 2010;17(2):289–94.CrossRefPubMedPubMedCentral Rack A, Rack T, Stiller M, Riesemeier H, Zabler S, Nelson K. In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants. J Synchrotron Radiat. 2010;17(2):289–94.CrossRefPubMedPubMedCentral
35.
go back to reference Sammour SR, Maamoun El-Sheikh M, Aly E-G. Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: in-vitro study. Dent Mater. 2019;35(11):e265–71.CrossRefPubMed Sammour SR, Maamoun El-Sheikh M, Aly E-G. Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: in-vitro study. Dent Mater. 2019;35(11):e265–71.CrossRefPubMed
36.
go back to reference Eskitascioglu G, Usumez A, Sevimay M, Soykan E, Unsal E. The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: a three-dimensional finite element study. J Prosthet Dent. 2004;91(2):144–50.CrossRefPubMed Eskitascioglu G, Usumez A, Sevimay M, Soykan E, Unsal E. The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: a three-dimensional finite element study. J Prosthet Dent. 2004;91(2):144–50.CrossRefPubMed
37.
go back to reference Lundgren D, Laurell L. Occlusal force pattern during chewing and biting in dentitions restored with fixed bridges of cross-arch extension. II. Unilateral posterior two-unit cantilevers. J Oral Rehabil. 1986;13(2):191–203.CrossRefPubMed Lundgren D, Laurell L. Occlusal force pattern during chewing and biting in dentitions restored with fixed bridges of cross-arch extension. II. Unilateral posterior two-unit cantilevers. J Oral Rehabil. 1986;13(2):191–203.CrossRefPubMed
38.
go back to reference Steinemann SG. Titanium–the material of choice? Periodontol. 2000;1998(17):7–21. Steinemann SG. Titanium–the material of choice? Periodontol. 2000;1998(17):7–21.
39.
go back to reference Xiao S, Kong X, Yao J, Liu J, Li L, Jiang T, et al. Differences in root stress and strain distribution in buccal and lingual orthodontics: a finite element analysis study. Medicine in Novel Technology and Devices. 2022;14: 100119.CrossRef Xiao S, Kong X, Yao J, Liu J, Li L, Jiang T, et al. Differences in root stress and strain distribution in buccal and lingual orthodontics: a finite element analysis study. Medicine in Novel Technology and Devices. 2022;14: 100119.CrossRef
40.
go back to reference Kul E, Korkmaz İH. Effect of different design of abutment and implant on stress distribution in 2 implants and peripheral bone: a finite element analysis study. J Prosthet Dent. 2021;126(5):664.e1-664.e9.CrossRefPubMed Kul E, Korkmaz İH. Effect of different design of abutment and implant on stress distribution in 2 implants and peripheral bone: a finite element analysis study. J Prosthet Dent. 2021;126(5):664.e1-664.e9.CrossRefPubMed
Metadata
Title
Influence of a new abutment design concept on the biomechanics of peri-implant bone, implant components, and microgap formation: a finite element analysis
Authors
Huimin Nie
Yantai Tang
Yan Yang
Weijie Wu
Wenjuan Zhou
Zhonghao Liu
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-02989-x

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue