Implementation of Continuous Video-Electroencephalography at a Community Hospital Enhances Care and Reduces Costs

Authors: Brad J. Kolls, Brian E. Mace, Keith E. Dombrowski

Published in: Neurocritical Care | Issue 2/2018

Login to get access

Abstract

Background

Despite data indicating the importance of continuous video-electroencephalography (cvEEG) monitoring, adoption has been slow outside major academic centers. Barriers to adoption include the need for technologists, equipment, and cvEEG readers. Advancements in lower-cost lead placement templates and commercial systems with remote review may reduce barriers to allow community centers to implement cvEEG. Here, we report our experience, lessons learned, and financial impact of implementing a community hospital cvEEG-monitoring program.

Methods

We implemented an adult cvEEG service at Duke Regional Hospital (DRH), a community hospital affiliate, in June of 2012. Lead placement templates were used in the implementation to reduce the impact on technologists by using other bedside providers for EEG initiation. Utilization of the service, study quality, and patient outcomes were tracked over a 3-year period following initiation of service.

Results

Service was implemented at essentially no cost. Utilization varied from a number of factors: intensive care unit (ICU) attending awareness, limited willingness of bedside providers to perform lead placement, and variation in practice of the consulting neurologists. A total of 92 studies were performed on 88 patients in the first 3 years of the program, 24 in year one, 27 in year two, and 38 in year three, showing progressive adoption. Seizures were seen in 25 patients (27%), 19 were in status, of which 18 were successfully treated. Transfers to the main hospital, Duke University Medical Center, were prevented for 53 patients, producing an estimated cost savings of $145,750. The retained patients produced a direct contribution margin of about $75,000, and the margin was just over $100,000 for the entire monitored cohort.

Conclusion

ICU cvEEG service is feasible and practical to implement at the community hospital level. Service was initiated at little to no cost and clearly enhanced care, increased breadth of care, increased ICU census, and reduced transfers. The system allowed for successful management of ICU patients with underlying seizures and eliminated interfacility transfers, producing a savings of $145,750. The savings combined with the retained patient revenue produced a total revenue of over $250,000 with additional revenue in professional services as well. These results suggest expansion of cvEEG monitoring to community ICUs is practical, financially sustainable, improves the level and quality of care, and reduces costs.
Literature
1.
go back to reference Le Roux P, Menon DK, Citerio G, Vespa P, Bader MK, Brophy GM, et al. Consensus summary statement of the international multidisciplinary consensus conference on multimodality monitoring in neurocritical care: a statement for healthcare professionals from the neurocritical care society and the European society of intensive care medicine. Intensive Care Med. 2014;40(9):1189–209.CrossRefPubMed Le Roux P, Menon DK, Citerio G, Vespa P, Bader MK, Brophy GM, et al. Consensus summary statement of the international multidisciplinary consensus conference on multimodality monitoring in neurocritical care: a statement for healthcare professionals from the neurocritical care society and the European society of intensive care medicine. Intensive Care Med. 2014;40(9):1189–209.CrossRefPubMed
2.
go back to reference Gavvala J, Abend N, LaRoche S, Hahn C, Herman ST, Claassen J, et al. Continuous EEG monitoring: a survey of neurophysiologists and neurointensivists. Epilepsia. 2014;55(11):1864–71.CrossRefPubMed Gavvala J, Abend N, LaRoche S, Hahn C, Herman ST, Claassen J, et al. Continuous EEG monitoring: a survey of neurophysiologists and neurointensivists. Epilepsia. 2014;55(11):1864–71.CrossRefPubMed
3.
go back to reference Claassen J, Vespa P. Electrophysiologic monitoring in acute brain injury. Neurocrit Care. 2014;21(Suppl 2):S129–47.CrossRefPubMed Claassen J, Vespa P. Electrophysiologic monitoring in acute brain injury. Neurocrit Care. 2014;21(Suppl 2):S129–47.CrossRefPubMed
4.
go back to reference Claassen J, Taccone FS, Horn P, Holtkamp M, Stocchetti N, Oddo M. Recommendations on the use of EEG monitoring in critically ill patients: consensus statement from the neurointensive care section of the ESICM. Intensive Care Med. 2013;39(8):1337–51.CrossRefPubMed Claassen J, Taccone FS, Horn P, Holtkamp M, Stocchetti N, Oddo M. Recommendations on the use of EEG monitoring in critically ill patients: consensus statement from the neurointensive care section of the ESICM. Intensive Care Med. 2013;39(8):1337–51.CrossRefPubMed
5.
go back to reference Kolls BJ, Olson DM, Gallentine WB, Skeen MB, Skidmore CT, Sinha SR. Electroencephalography leads placed by nontechnologists using a template system produce signals equal in quality to technologist-applied, collodion disk leads. J Clin Neurophysiol. 2012;29(1):42–9.CrossRefPubMed Kolls BJ, Olson DM, Gallentine WB, Skeen MB, Skidmore CT, Sinha SR. Electroencephalography leads placed by nontechnologists using a template system produce signals equal in quality to technologist-applied, collodion disk leads. J Clin Neurophysiol. 2012;29(1):42–9.CrossRefPubMed
6.
go back to reference Kolls BJ, Husain AM. Assessment of hairline EEG as a screening tool for nonconvulsive status epilepticus. Epilepsia. 2007;48(5):959–65.CrossRefPubMed Kolls BJ, Husain AM. Assessment of hairline EEG as a screening tool for nonconvulsive status epilepticus. Epilepsia. 2007;48(5):959–65.CrossRefPubMed
7.
go back to reference Hirsch LJ, LaRoche SM, Gaspard N, Gerard E, Svoronos A, Herman ST, et al. American clinical neurophysiology society’s standardized critical care EEG terminology: 2012 version. J Clin Neurophysiol. 2013;30(1):1–27.CrossRefPubMed Hirsch LJ, LaRoche SM, Gaspard N, Gerard E, Svoronos A, Herman ST, et al. American clinical neurophysiology society’s standardized critical care EEG terminology: 2012 version. J Clin Neurophysiol. 2013;30(1):1–27.CrossRefPubMed
8.
go back to reference Sondag L, Ruijter BJ, Tjepkema-Cloostermans MC, Beishuizen A, Bosch FH, van Til JA, et al. Early EEG for outcome prediction of postanoxic coma: prospective cohort study with cost-minimization analysis. Crit Care. 2017;21(1):111.CrossRefPubMedPubMedCentral Sondag L, Ruijter BJ, Tjepkema-Cloostermans MC, Beishuizen A, Bosch FH, van Til JA, et al. Early EEG for outcome prediction of postanoxic coma: prospective cohort study with cost-minimization analysis. Crit Care. 2017;21(1):111.CrossRefPubMedPubMedCentral
9.
go back to reference Hofmeijer J, Beernink TM, Bosch FH, Beishuizen A, Tjepkema-Cloostermans MC, van Putten MJ. Early EEG contributes to multimodal outcome prediction of postanoxic coma. Neurology. 2015;85(2):137–43.CrossRefPubMedPubMedCentral Hofmeijer J, Beernink TM, Bosch FH, Beishuizen A, Tjepkema-Cloostermans MC, van Putten MJ. Early EEG contributes to multimodal outcome prediction of postanoxic coma. Neurology. 2015;85(2):137–43.CrossRefPubMedPubMedCentral
10.
go back to reference Milani P, Malissin I, Tran-Dinh YR, Deye N, Baud F, Levy BI, et al. Prognostic EEG patterns in patients resuscitated from cardiac arrest with particular focus on generalized periodic epileptiform discharges (GPEDs). Neurophysiol Clin Clin Neurophysiol. 2014;44(2):153–64.CrossRef Milani P, Malissin I, Tran-Dinh YR, Deye N, Baud F, Levy BI, et al. Prognostic EEG patterns in patients resuscitated from cardiac arrest with particular focus on generalized periodic epileptiform discharges (GPEDs). Neurophysiol Clin Clin Neurophysiol. 2014;44(2):153–64.CrossRef
11.
go back to reference Cloostermans MC, van Meulen FB, Eertman CJ, Hom HW, van Putten MJ. Continuous electroencephalography monitoring for early prediction of neurological outcome in postanoxic patients after cardiac arrest: a prospective cohort study. Crit Care Med. 2012;40(10):2867–75.CrossRefPubMed Cloostermans MC, van Meulen FB, Eertman CJ, Hom HW, van Putten MJ. Continuous electroencephalography monitoring for early prediction of neurological outcome in postanoxic patients after cardiac arrest: a prospective cohort study. Crit Care Med. 2012;40(10):2867–75.CrossRefPubMed
12.
go back to reference Kolls BJ, Lai AH, Srinivas AA, Reid RR. Integration of EEG lead placement templates into traditional technologist-based staffing models reduces costs in continuous video-EEG monitoring service. J Clin Neurophysiol. 2014;31(3):187–93.CrossRefPubMed Kolls BJ, Lai AH, Srinivas AA, Reid RR. Integration of EEG lead placement templates into traditional technologist-based staffing models reduces costs in continuous video-EEG monitoring service. J Clin Neurophysiol. 2014;31(3):187–93.CrossRefPubMed
Metadata
Title
Implementation of Continuous Video-Electroencephalography at a Community Hospital Enhances Care and Reduces Costs
Authors
Brad J. Kolls
Brian E. Mace
Keith E. Dombrowski
Publication date
01-04-2018
Publisher
Springer US
Published in
Neurocritical Care / Issue 2/2018
Print ISSN: 1541-6933
Electronic ISSN: 1556-0961
DOI
https://doi.org/10.1007/s12028-017-0468-6

Other articles of this Issue 2/2018

Neurocritical Care 2/2018 Go to the issue