Skip to main content
Top
Published in: European Journal of Clinical Microbiology & Infectious Diseases 12/2018

01-12-2018 | Original Article

Impact of total laboratory automation on workflow and specimen processing time for culture of urine specimens

Authors: Melanie L. Yarbrough, William Lainhart, Allison R. McMullen, Neil W. Anderson, Carey-Ann D. Burnham

Published in: European Journal of Clinical Microbiology & Infectious Diseases | Issue 12/2018

Login to get access

Abstract

Total laboratory automation (TLA) has the potential to reduce specimen processing time, improve standardization of cultures, and decrease turnaround time (TAT). The objective of this study was to perform a detailed interrogation of the impact of TLA implementation in all aspects of the workflow for routine culture of urine specimens. Using a detailed motion capture study, the time required for major steps of processing and result reporting were prospectively assessed for urine samples prior to (n = 215) and after (n = 203) implementation of the BD Kiestra TLA system. Specimens were plated on all shifts, but cultures were read only during the day shift for both time periods. Significant increases were noted in the time from receipt to inoculation (23.0 min versus 32.0 min, p < 0.001) and total processing time (28.0 min versus 66.0 min, p < 0.0001) for urine specimens post-TLA. Rates of positive (18.6% versus 16.3%) and negative (71.2% versus 79.3%) urine cultures remained stable through the pre- and post-TLA time periods (p = 0.58). There were no changes in TAT for organism identification or susceptibility results. The time to final report was decreased from 43.8 h pre-TLA to 42.0 h post-TLA, which was attributed to significant decreases in TAT for negative cultures (42.0 h versus 37.5 h, p = 0.01). These findings demonstrate that changes in laboratory workflow are necessary to maximize efficiency of TLA and optimize TAT.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sautter RL, Thomson RB Jr (2015) Consolidated clinical microbiology laboratories. J Clin Microbiol 53(5):1467–1472CrossRef Sautter RL, Thomson RB Jr (2015) Consolidated clinical microbiology laboratories. J Clin Microbiol 53(5):1467–1472CrossRef
2.
go back to reference Garcia E, Ali AM, Soles RM, Lewis DG (2015) The American Society for Clinical Pathology’s 2014 vacancy survey of medical laboratories in the United States. Am J Clin Pathol 144(3):432–443CrossRef Garcia E, Ali AM, Soles RM, Lewis DG (2015) The American Society for Clinical Pathology’s 2014 vacancy survey of medical laboratories in the United States. Am J Clin Pathol 144(3):432–443CrossRef
3.
go back to reference Genzen JR, Burnham CD, Felder RA, Hawker CD, Lippi G, Peck Palmer OM (2018) Challenges and opportunities in implementing total laboratory automation. Clin Chem 64(2):259–264CrossRef Genzen JR, Burnham CD, Felder RA, Hawker CD, Lippi G, Peck Palmer OM (2018) Challenges and opportunities in implementing total laboratory automation. Clin Chem 64(2):259–264CrossRef
4.
go back to reference Bourbeau PP, Ledeboer NA (2013) Automation in clinical microbiology. J Clin Microbiol 51(6):1658–1665CrossRef Bourbeau PP, Ledeboer NA (2013) Automation in clinical microbiology. J Clin Microbiol 51(6):1658–1665CrossRef
5.
go back to reference Ledeboer NA, Dallas SD (2014) The automated clinical microbiology laboratory: fact or fantasy? J Clin Microbiol 52(9):3140–3146CrossRef Ledeboer NA, Dallas SD (2014) The automated clinical microbiology laboratory: fact or fantasy? J Clin Microbiol 52(9):3140–3146CrossRef
6.
go back to reference Croxatto A, Prod'hom G, Faverjon F, Rochais Y, Greub G (2016) Laboratory automation in clinical bacteriology: what system to choose?. Clin Microbiol Infect 22(3):217–235CrossRef Croxatto A, Prod'hom G, Faverjon F, Rochais Y, Greub G (2016) Laboratory automation in clinical bacteriology: what system to choose?. Clin Microbiol Infect 22(3):217–235CrossRef
7.
go back to reference Da Rin G, Zoppelletto M, Lippi G (2016) Integration of diagnostic microbiology in a model of total laboratory automation. Lab Med 47(1):73–82CrossRef Da Rin G, Zoppelletto M, Lippi G (2016) Integration of diagnostic microbiology in a model of total laboratory automation. Lab Med 47(1):73–82CrossRef
8.
go back to reference Faron ML, Buchan BW, Coon C, Liebregts T, van Bree A, Jansz AR, Soucy G, Korver J, Ledeboer NA (2016) Automatic digital analysis of chromogenic media for vancomycin-resistant-enterococcus screens using Copan WASPLab. J Clin Microbiol 54(10):2464–2469CrossRef Faron ML, Buchan BW, Coon C, Liebregts T, van Bree A, Jansz AR, Soucy G, Korver J, Ledeboer NA (2016) Automatic digital analysis of chromogenic media for vancomycin-resistant-enterococcus screens using Copan WASPLab. J Clin Microbiol 54(10):2464–2469CrossRef
9.
go back to reference Faron ML, Buchan BW, Vismara C, Lacchini C, Bielli A, Gesu G, Liebregts T, van Bree A, Jansz A, Soucy G, Korver J, Ledeboer NA (2016) Automated scoring of chromogenic media for detection of methicillin-resistant staphylococcus aureus by use of WASPLab image analysis software. J Clin Microbiol 54(3):620–624CrossRef Faron ML, Buchan BW, Vismara C, Lacchini C, Bielli A, Gesu G, Liebregts T, van Bree A, Jansz A, Soucy G, Korver J, Ledeboer NA (2016) Automated scoring of chromogenic media for detection of methicillin-resistant staphylococcus aureus by use of WASPLab image analysis software. J Clin Microbiol 54(3):620–624CrossRef
10.
go back to reference Kirn TJ (2016) Automatic digital plate reading for surveillance cultures. J Clin Microbiol 54(10):2424–2426CrossRef Kirn TJ (2016) Automatic digital plate reading for surveillance cultures. J Clin Microbiol 54(10):2424–2426CrossRef
11.
go back to reference McAdam AJ (2018) Total laboratory automation in clinical microbiology: a micro-comic strip. J Clin Microbiol 56 (4) McAdam AJ (2018) Total laboratory automation in clinical microbiology: a micro-comic strip. J Clin Microbiol 56 (4)
12.
go back to reference Burckhardt I, Panitz J, Burckhardt F, Zimmermann S (2017) Identification of Streptococcus pneumoniae: development of a standardized protocol for optochin susceptibility testing using total lab automation. Biomed Res Int 2017:4174168CrossRef Burckhardt I, Panitz J, Burckhardt F, Zimmermann S (2017) Identification of Streptococcus pneumoniae: development of a standardized protocol for optochin susceptibility testing using total lab automation. Biomed Res Int 2017:4174168CrossRef
13.
go back to reference Hombach M, Jetter M, Blochliger N, Kolesnik-Goldmann N, Bottger EC (2017) Fully automated disc diffusion for rapid antibiotic susceptibility test results: a proof-of-principle study. J Antimicrob Chemother 72(6):1659–1668CrossRef Hombach M, Jetter M, Blochliger N, Kolesnik-Goldmann N, Bottger EC (2017) Fully automated disc diffusion for rapid antibiotic susceptibility test results: a proof-of-principle study. J Antimicrob Chemother 72(6):1659–1668CrossRef
14.
go back to reference Bailey A, Ledeboer N, Burnham CA (2018) Clinical microbiology is growing up: the total laboratory automation revolution. Clin Chem in press Bailey A, Ledeboer N, Burnham CA (2018) Clinical microbiology is growing up: the total laboratory automation revolution. Clin Chem in press
15.
go back to reference Dauwalder O, Landrieve L, Laurent F, de Montclos M, Vandenesch F, Lina G (2016) Does bacteriology laboratory automation reduce time to results and increase quality management?. Clin Microbiol Infect 22(3):236–243CrossRef Dauwalder O, Landrieve L, Laurent F, de Montclos M, Vandenesch F, Lina G (2016) Does bacteriology laboratory automation reduce time to results and increase quality management?. Clin Microbiol Infect 22(3):236–243CrossRef
16.
go back to reference Croxatto A, Dijkstra K, Prod’hom G, Greub G (2015) Comparison of inoculation with the InoqulA and WASP automated systems with manual inoculation. J Clin Microbiol 53(7):2298–2307CrossRef Croxatto A, Dijkstra K, Prod’hom G, Greub G (2015) Comparison of inoculation with the InoqulA and WASP automated systems with manual inoculation. J Clin Microbiol 53(7):2298–2307CrossRef
17.
go back to reference Froment P, Marchandin H, Vande Perre P, Lamy B (2014) Automated versus manual sample inoculations in routine clinical microbiology: a performance evaluation of the fully automated InoqulA instrument. J Clin Microbiol 52(3):796–802CrossRef Froment P, Marchandin H, Vande Perre P, Lamy B (2014) Automated versus manual sample inoculations in routine clinical microbiology: a performance evaluation of the fully automated InoqulA instrument. J Clin Microbiol 52(3):796–802CrossRef
18.
go back to reference Graham M, Tilson L, Streitberg R, Hamblin J, Korman TM (2016) Improved standardization and potential for shortened time to results with BD Kiestra total laboratory automation of early urine cultures: a prospective comparison with manual processing. Diagn Microbiol Infect Dis 86(1):1–4CrossRef Graham M, Tilson L, Streitberg R, Hamblin J, Korman TM (2016) Improved standardization and potential for shortened time to results with BD Kiestra total laboratory automation of early urine cultures: a prospective comparison with manual processing. Diagn Microbiol Infect Dis 86(1):1–4CrossRef
19.
go back to reference Mutters NT, Hodiamont CJ, de Jong MD, Overmeijer HP, van den Boogaard M, Visser CE (2014) Performance of Kiestra total laboratory automation combined with MS in clinical microbiology practice. Ann Lab Med 34(2):111–117CrossRef Mutters NT, Hodiamont CJ, de Jong MD, Overmeijer HP, van den Boogaard M, Visser CE (2014) Performance of Kiestra total laboratory automation combined with MS in clinical microbiology practice. Ann Lab Med 34(2):111–117CrossRef
20.
go back to reference Theparee T, Das S, Thomson RB, Jr. (2018) Total laboratory automation and matrix-assisted laser desorption ionization-time of flight mass spectrometry improve turnaround times in the clinical microbiology laboratory: a retrospective analysis. J Clin Microbiol 56 (1) Theparee T, Das S, Thomson RB, Jr. (2018) Total laboratory automation and matrix-assisted laser desorption ionization-time of flight mass spectrometry improve turnaround times in the clinical microbiology laboratory: a retrospective analysis. J Clin Microbiol 56 (1)
21.
go back to reference Buchan BW, Olson WJ, Mackey TL, Ledeboer NA (2014) Clinical evaluation of the walk-away specimen processor and ESwab for recovery of Streptococcus agalactiae isolates in prenatal screening specimens. J Clin Microbiol 52(6):2166–2168CrossRef Buchan BW, Olson WJ, Mackey TL, Ledeboer NA (2014) Clinical evaluation of the walk-away specimen processor and ESwab for recovery of Streptococcus agalactiae isolates in prenatal screening specimens. J Clin Microbiol 52(6):2166–2168CrossRef
22.
go back to reference Strauss S, Bourbeau PP (2015) Impact of introduction of the BD Kiestra InoqulA on urine culture results in a hospital clinical microbiology laboratory. J Clin Microbiol 53(5):1736–1740CrossRef Strauss S, Bourbeau PP (2015) Impact of introduction of the BD Kiestra InoqulA on urine culture results in a hospital clinical microbiology laboratory. J Clin Microbiol 53(5):1736–1740CrossRef
23.
go back to reference Klein S, Nurjadi D, Horner S, Heeg K, Zimmermann S, Burckhardt I (2018) Significant increase in cultivation of Gardnerella vaginalis, Alloscardovia omnicolens, Actinotignum schaalii, and Actinomyces spp. in urine samples with total laboratory automation. Eur J Clin Microbiol Infect Dis 37(7):1305–1311CrossRef Klein S, Nurjadi D, Horner S, Heeg K, Zimmermann S, Burckhardt I (2018) Significant increase in cultivation of Gardnerella vaginalis, Alloscardovia omnicolens, Actinotignum schaalii, and Actinomyces spp. in urine samples with total laboratory automation. Eur J Clin Microbiol Infect Dis 37(7):1305–1311CrossRef
24.
go back to reference Lainhart W, Burnham CA (2018) Enhanced recovery of fastidious organisms from urine culture in the setting of total laboratory automation. J Clin Microbiol 56 (8) Lainhart W, Burnham CA (2018) Enhanced recovery of fastidious organisms from urine culture in the setting of total laboratory automation. J Clin Microbiol 56 (8)
25.
go back to reference Dauwalder O, Vandenesch F (2014) Clinical microbiology laboratory: from the Pasteur model to the 24/7 clinical chemistry concept. Clin Microbiol Infect 20(10):O593–O594CrossRef Dauwalder O, Vandenesch F (2014) Clinical microbiology laboratory: from the Pasteur model to the 24/7 clinical chemistry concept. Clin Microbiol Infect 20(10):O593–O594CrossRef
Metadata
Title
Impact of total laboratory automation on workflow and specimen processing time for culture of urine specimens
Authors
Melanie L. Yarbrough
William Lainhart
Allison R. McMullen
Neil W. Anderson
Carey-Ann D. Burnham
Publication date
01-12-2018
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Clinical Microbiology & Infectious Diseases / Issue 12/2018
Print ISSN: 0934-9723
Electronic ISSN: 1435-4373
DOI
https://doi.org/10.1007/s10096-018-3391-7

Other articles of this Issue 12/2018

European Journal of Clinical Microbiology & Infectious Diseases 12/2018 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.