Skip to main content
Top
Published in: Pediatric Cardiology 6/2021

01-08-2021 | Heart Failure | Original Article

Left Ventricular Torsion Obtained Using Equilibrated Warping in Patients with Repaired Tetralogy of Fallot

Authors: Daniel Alexander Castellanos, Kateřina Škardová, Abhijit Bhattaru, Ezgi Berberoglu, Gerald Greil, Animesh Tandon, Jeanne Dillenbeck, Barbara Burkhardt, Tarique Hussain, Martin Genet, Radomir Chabiniok

Published in: Pediatric Cardiology | Issue 6/2021

Login to get access

Abstract

Patients after surgical repair of Tetralogy of Fallot (rTOF) may suffer a decrease in left ventricular (LV) function. The aim of our study is to evaluate a novel method of assessing LV torsion in patients with rTOF, as an early indicator of systolic LV dysfunction. Motion tracking based on image registration regularized by the equilibrium gap principle, known as equilibrated warping, was employed to assess LV torsion. Seventy-six cases of rTOF and ten normal controls were included. The group of controls was assessed for reproducibility using both equilibrated warping and standard clinical tissue tracking software (CVI42, version 5.10.1, Calgary, Canada). Patients were dichotomized into two groups: normal vs. loss of torsion. Torsion by equilibrated warping was successfully obtained in 68 of 76 (89%) patients and 9 of 10 (90%) controls. For equilibrated warping, the intra- and interobserver coefficients of variation were 0.095 and 0.117, respectively, compared to 0.260 and 0.831 for tissue tracking by standard clinical software. The intra- and inter-observer intraclass correlation coefficients for equilibrated warping were 0.862 and 0.831, respectively, compared to 0.992 and 0.648 for tissue tracking. Loss of torsion was noted in 32 of the 68 (47%) patients with rTOF. There was no difference in LV or RV volumes or ejection fraction between these groups. The assessment of LV torsion by equilibrated warping is feasible and shows good reliability. Loss of torsion is common in patients with rTOF and its robust assessment might contribute into uncovering heart failure in an earlier stage.
Literature
7.
go back to reference Davlouros PA, Kilner PJ, Hornung TS et al (2002) Right ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imaging: detrimental role of right ventricular outflow aneurysms or akinesia and adverse right-to-left ventricular interaction. J Am Coll Cardiol 40:2044–2052. https://doi.org/10.1016/s0735-1097(02)02566-4CrossRefPubMed Davlouros PA, Kilner PJ, Hornung TS et al (2002) Right ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imaging: detrimental role of right ventricular outflow aneurysms or akinesia and adverse right-to-left ventricular interaction. J Am Coll Cardiol 40:2044–2052. https://​doi.​org/​10.​1016/​s0735-1097(02)02566-4CrossRefPubMed
19.
go back to reference Lee LC, Genet M (2019) Validation of equilibrated warping—image registration with mechanical regularization—On 3D ultrasound images. In: Coudière Y, Ozenne V, Vigmond E, Zemzemi N (eds) Functional imaging and modeling of the heart: FIMH 2019. Springer, Cham, pp 334–341CrossRef Lee LC, Genet M (2019) Validation of equilibrated warping—image registration with mechanical regularization—On 3D ultrasound images. In: Coudière Y, Ozenne V, Vigmond E, Zemzemi N (eds) Functional imaging and modeling of the heart: FIMH 2019. Springer, Cham, pp 334–341CrossRef
22.
go back to reference Geuzaine C, Remacle J-F (2009) Gmsh: a three-dimensional finite element mesh generator with built-in pre- and post-processing facilities. Int J Numer Methods Eng 79:1309–1331CrossRef Geuzaine C, Remacle J-F (2009) Gmsh: a three-dimensional finite element mesh generator with built-in pre- and post-processing facilities. Int J Numer Methods Eng 79:1309–1331CrossRef
24.
go back to reference Škardová K, Rambausek M, Chabiniok R, Genet M (2019) Mechanical and imaging models-based image registration. In: Tavares JMRS, Natal Jorge RM (eds) VipIMAGE 2019. Springer, Cham, pp 77–85CrossRef Škardová K, Rambausek M, Chabiniok R, Genet M (2019) Mechanical and imaging models-based image registration. In: Tavares JMRS, Natal Jorge RM (eds) VipIMAGE 2019. Springer, Cham, pp 77–85CrossRef
Metadata
Title
Left Ventricular Torsion Obtained Using Equilibrated Warping in Patients with Repaired Tetralogy of Fallot
Authors
Daniel Alexander Castellanos
Kateřina Škardová
Abhijit Bhattaru
Ezgi Berberoglu
Gerald Greil
Animesh Tandon
Jeanne Dillenbeck
Barbara Burkhardt
Tarique Hussain
Martin Genet
Radomir Chabiniok
Publication date
01-08-2021
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 6/2021
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-021-02608-y

Other articles of this Issue 6/2021

Pediatric Cardiology 6/2021 Go to the issue