Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 1/2015

01-01-2015 | Images in CV Applications

First report of image integration of cine-angiography with 3D electro-anatomical mapping of the right ventricle in postoperative Tetralogy of Fallot

Authors: Mario Salvatore Russo, Daniela Righi, Corrado Di Mambro, Valentina Ruoppolo, Massimo Stefano Silvetti, Fabrizio Drago

Published in: The International Journal of Cardiovascular Imaging | Issue 1/2015

Login to get access

Abstract

Ventricular tachycardia and, more rarely, sudden cardiac death are potential complications affecting the long-term outcome after Tetralogy of Fallot (ToF) repair. Intraventricular septal scar, fibro-fatty substitution around infundibular resection and patchy myocardial fibrosis may provide anatomical substrates of abnormal depolarization and repolarization causing reentrant ventricular arrhythmias. Recently, three-dimensional electro-anatomical mapping (3D EAM) has allowed to investigate the electro-anatomical status of the right ventricle. Radiation exposure during cardiac electrophysiological procedures is still a major concern. We report the first case of 3D mapping of the right ventricle in a postoperative ToF patient performed with a new module of the CARTO® 3 System—the CARTOUnivu™ Module—that combines, simultaneously, fluoroscopic images or cine-angiographic sequences with 3D cardiac mapping to allow real-time visualization of the electrocatheter during the 3D EAM reconstruction. The same volume, previously evaluated with cardiac MRI, was mapped. A perfect match of the diastolic edges of the RV obtained either by cine-loop acquisition during contrast fluoroscopy and by the 3D EAM, was observed. The fluoroscopy time for 3D EAM was 10 s. In conclusion, CARTOUnivu™ Module can integrate, in real time, fluoroscopic images/cine-angiography in virtual biplane view and the 3D EAM allowing a contextual visualization of position and movement of all electrocatheters. This can further increase the accuracy of the 3D EAM in very complex-operated congenital heart diseases, even decreasing radiation exposure.
Literature
1.
go back to reference Gatzoulis MA, Balaji S, Webber SA, Siu SC, Hokanson JS, Poile C, Rosenthal M, Nakazawa M, Moller JH, Gillette PC, Webb GD, Redington AN (2000) Risk factors for arrhythmia and sudden cardiac death late after repair of tetralogy of Fallot: a multicentre study. Lancet 356:975–981PubMedCrossRef Gatzoulis MA, Balaji S, Webber SA, Siu SC, Hokanson JS, Poile C, Rosenthal M, Nakazawa M, Moller JH, Gillette PC, Webb GD, Redington AN (2000) Risk factors for arrhythmia and sudden cardiac death late after repair of tetralogy of Fallot: a multicentre study. Lancet 356:975–981PubMedCrossRef
2.
go back to reference Hsia HH, Marchlinski FE (2002) Characterization of the electroanatomic substrate for monomorphic ventricular tachycardia in patients with nonischemic cardiomyopathy. Pacing Clin Electrophysiol 25:1114–1127PubMedCrossRef Hsia HH, Marchlinski FE (2002) Characterization of the electroanatomic substrate for monomorphic ventricular tachycardia in patients with nonischemic cardiomyopathy. Pacing Clin Electrophysiol 25:1114–1127PubMedCrossRef
Metadata
Title
First report of image integration of cine-angiography with 3D electro-anatomical mapping of the right ventricle in postoperative Tetralogy of Fallot
Authors
Mario Salvatore Russo
Daniela Righi
Corrado Di Mambro
Valentina Ruoppolo
Massimo Stefano Silvetti
Fabrizio Drago
Publication date
01-01-2015
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 1/2015
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-014-0512-y

Other articles of this Issue 1/2015

The International Journal of Cardiovascular Imaging 1/2015 Go to the issue