Skip to main content
Top
Published in: Heart Failure Reviews 3/2015

01-05-2015

Evidence of clinical efficacy of counterpulsation therapy methods

Authors: M. Capoccia, C. T. Bowles, J. R. Pepper, N. R. Banner, A. R. Simon

Published in: Heart Failure Reviews | Issue 3/2015

Login to get access

Abstract

Although heart transplantation remains the ultimate treatment for end-stage heart failure, its epidemiological impact is limited by donor organ availability. Surgical and device-based approaches have been introduced with the aim of increasing systemic perfusion and in some circumstances promoting left ventricular recovery by inducing reverse remodelling. Innovative counterpulsation devices based on the established principle of the intra-aortic balloon pump have been developed, and of these, the CardioVad and the C-Pulse System have been introduced in clinical practice with convincing evidence of haemodynamic efficacy. The evolution from pulsatile to continuous-flow left ventricular assist devices has been associated with improved survival rates during the first 2 years of support with the potential of matching heart transplantation outcomes. However, blood contact with the device remains a significant challenge despite the highly sophisticated technology currently available. Innovative extra-vascular counterpulsation devices have been shown to overcome the limitations of the intra-aortic balloon pump and rend the device suitable for prolonged support. Monitoring of the performance of these novel devices is essential, and carotid Doppler ultrasonography is of utility in assessing the haemodynamic performance of the devices in a clinical setting. Computational modelling has played a role in the simulation of these devices and should continue to assist with their optimisation and implementation in clinical practice.
Literature
1.
go back to reference MacGowan GA, Parry G, Schueler S, Hasan A (2011) The decline in heart transplantation in the UK. BMJ 342:d2483PubMedCrossRef MacGowan GA, Parry G, Schueler S, Hasan A (2011) The decline in heart transplantation in the UK. BMJ 342:d2483PubMedCrossRef
2.
go back to reference Jones RH, Velazquez EJ, Michler RE, Sopko G, Oh JK, O’Connor CM, Hill JA, Menicanti L, Sadowski Z, Desvigne-Nickens P, Rouleau J-L, Lee KL, the STICH Hypothesis 2 Investigators (2009) Coronary bypass surgery with or without surgical ventricular reconstruction. N Engl J Med 360:1705–1717PubMedCentralPubMedCrossRef Jones RH, Velazquez EJ, Michler RE, Sopko G, Oh JK, O’Connor CM, Hill JA, Menicanti L, Sadowski Z, Desvigne-Nickens P, Rouleau J-L, Lee KL, the STICH Hypothesis 2 Investigators (2009) Coronary bypass surgery with or without surgical ventricular reconstruction. N Engl J Med 360:1705–1717PubMedCentralPubMedCrossRef
3.
go back to reference Dor V, Civaia F, Alexandrescu C, Sabatier M, Montiglio F (2011) Favourable effects of left ventricular reconstruction in patients excluded from the surgical treatments for ischemic heart failure (STICH) trial. J Thorac Cardiovasc Surg 141:905–916PubMedCrossRef Dor V, Civaia F, Alexandrescu C, Sabatier M, Montiglio F (2011) Favourable effects of left ventricular reconstruction in patients excluded from the surgical treatments for ischemic heart failure (STICH) trial. J Thorac Cardiovasc Surg 141:905–916PubMedCrossRef
4.
go back to reference Blom AS, Mukherjee R, Pilla JJ, Lowry AS, Yarbrough WM, Mingoia JT, Hendrick JW, Stroud RE, McLean JE, Affuso J, Gorman RC, Gorman JH 3rd, Acker MA, Spinale FG (2005) Cardiac support device modifies left ventricular geometry and myocardial structure after myocardial infarction. Circulation 112:1274–1283PubMedCrossRef Blom AS, Mukherjee R, Pilla JJ, Lowry AS, Yarbrough WM, Mingoia JT, Hendrick JW, Stroud RE, McLean JE, Affuso J, Gorman RC, Gorman JH 3rd, Acker MA, Spinale FG (2005) Cardiac support device modifies left ventricular geometry and myocardial structure after myocardial infarction. Circulation 112:1274–1283PubMedCrossRef
5.
go back to reference Pilla JJ, Blom AS, Brockman DJ, Bowen F, Yuan Q, Giammarco J, Ferrari VA, Gorman JH 3rd, Gorman RC, Acker MA (2002) Ventricular constraint using the acorn cardiac support device reduces myocardial akinetic area in an ovine model of acute infarction. Circulation 106:1207–1211 Pilla JJ, Blom AS, Brockman DJ, Bowen F, Yuan Q, Giammarco J, Ferrari VA, Gorman JH 3rd, Gorman RC, Acker MA (2002) Ventricular constraint using the acorn cardiac support device reduces myocardial akinetic area in an ovine model of acute infarction. Circulation 106:1207–1211
6.
go back to reference Magovern JA (2005) Experimental and clinical studies with the paracor cardiac restraint device. Semin Thorac Cardiovasc Surg 17:364–368PubMedCrossRef Magovern JA (2005) Experimental and clinical studies with the paracor cardiac restraint device. Semin Thorac Cardiovasc Surg 17:364–368PubMedCrossRef
7.
go back to reference Lazar RM, Shapiro PA, Jaski BE, Parides MK, Bourge RC, Watson JT, Damme L, Dembitsky W, Hosenpud JD, Gupta L, Tierney A, Kraus T, Naka Y (2004) Neurological events during long-term mechanical circulatory support for heart failure: the randomized evaluation of mechanical assistance for the treatment of congestive heart failure (REMATCH) experience. Circulation 109:2423–2427PubMedCrossRef Lazar RM, Shapiro PA, Jaski BE, Parides MK, Bourge RC, Watson JT, Damme L, Dembitsky W, Hosenpud JD, Gupta L, Tierney A, Kraus T, Naka Y (2004) Neurological events during long-term mechanical circulatory support for heart failure: the randomized evaluation of mechanical assistance for the treatment of congestive heart failure (REMATCH) experience. Circulation 109:2423–2427PubMedCrossRef
8.
go back to reference Jan KM (1985) Distribution of myocardial stress and its influence on coronary blood flow. J Biomech 18:815–820PubMedCrossRef Jan KM (1985) Distribution of myocardial stress and its influence on coronary blood flow. J Biomech 18:815–820PubMedCrossRef
9.
go back to reference Grossman W (1980) Cardiac hypertrophy: useful adaptation or pathologic process? Am J Med 69:576–584PubMedCrossRef Grossman W (1980) Cardiac hypertrophy: useful adaptation or pathologic process? Am J Med 69:576–584PubMedCrossRef
10.
go back to reference Huisman RM, Elzinga G, Westerhof N, Sipkeman P (1980) Measurement of left ventricular wall stress. Cardiovasc Res 14:142–153PubMedCrossRef Huisman RM, Elzinga G, Westerhof N, Sipkeman P (1980) Measurement of left ventricular wall stress. Cardiovasc Res 14:142–153PubMedCrossRef
12.
go back to reference Ratcliffe MB, Guy TS (2007) The effect of preoperative diastolic dysfunction on outcome after surgical ventricular remodelling. J Thorac Cardiovasc Surg 134:280–283PubMedCrossRef Ratcliffe MB, Guy TS (2007) The effect of preoperative diastolic dysfunction on outcome after surgical ventricular remodelling. J Thorac Cardiovasc Surg 134:280–283PubMedCrossRef
13.
go back to reference Rose EA, Moskowitz AJ, Packer M, Sollano JA, Williams DL, Tierney AR, Heitjan DF, Meier P, Ascheim DD, Levitan RG, Weinberg AD, Stevenson LW, Shapiro PA, Lazar RM, Watson JT, Goldstein DJ, Gelijns AC, for the REMATCH Investigators (1999) The REMATCH trial: rationale, design, and end points. Ann Thorac Surg 67:723–730PubMedCrossRef Rose EA, Moskowitz AJ, Packer M, Sollano JA, Williams DL, Tierney AR, Heitjan DF, Meier P, Ascheim DD, Levitan RG, Weinberg AD, Stevenson LW, Shapiro PA, Lazar RM, Watson JT, Goldstein DJ, Gelijns AC, for the REMATCH Investigators (1999) The REMATCH trial: rationale, design, and end points. Ann Thorac Surg 67:723–730PubMedCrossRef
14.
go back to reference Rose EA, Gelijns AC, Moskowitz AJ, Heitjan DF, Stevenson LW, Dembitsky W, Long JW, Ascheim DD, Tierney AR, Levitan RG, Watson JT, Meier P, for the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group (2001) Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med 345(20):1435–1443PubMedCrossRef Rose EA, Gelijns AC, Moskowitz AJ, Heitjan DF, Stevenson LW, Dembitsky W, Long JW, Ascheim DD, Tierney AR, Levitan RG, Watson JT, Meier P, for the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group (2001) Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med 345(20):1435–1443PubMedCrossRef
15.
go back to reference Park SJ, Tector A, Piccioni W, Raines E, Gelijns A, Moskowitz A, Rose E, Holman W, Furukawa S, Frazier OH, Dembitsky W (2005) Left ventricular assist devices as destination therapy: a new look at survival. J Thorac Cardiovasc Surg 129:9–17PubMedCrossRef Park SJ, Tector A, Piccioni W, Raines E, Gelijns A, Moskowitz A, Rose E, Holman W, Furukawa S, Frazier OH, Dembitsky W (2005) Left ventricular assist devices as destination therapy: a new look at survival. J Thorac Cardiovasc Surg 129:9–17PubMedCrossRef
16.
go back to reference Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM III, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH, for the HeartMate II Investigators (2009) Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 361:2241–2251PubMedCrossRef Slaughter MS, Rogers JG, Milano CA, Russell SD, Conte JV, Feldman D, Sun B, Tatooles AJ, Delgado RM III, Long JW, Wozniak TC, Ghumman W, Farrar DJ, Frazier OH, for the HeartMate II Investigators (2009) Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 361:2241–2251PubMedCrossRef
17.
go back to reference Boyle AJ, Ascheim DD, Russo MJ, Kormos RL, John R, Naka Y, Gelijns AC, Hong KN, Teuteberg JJ (2011) Clinical outcomes for continuous flow left ventricular assist device patients stratified by pre-operative INTERMACS classification. J Heart Lung Transplant 30(4):402–407PubMedCrossRef Boyle AJ, Ascheim DD, Russo MJ, Kormos RL, John R, Naka Y, Gelijns AC, Hong KN, Teuteberg JJ (2011) Clinical outcomes for continuous flow left ventricular assist device patients stratified by pre-operative INTERMACS classification. J Heart Lung Transplant 30(4):402–407PubMedCrossRef
18.
go back to reference Kirklin JK, Naftel DC, Pagani FD, Kormos RL, Stevenson L, Miller M, Young JB (2012) Long-term mechanical circulatory support (destination therapy): on track to compete with heart transplantation? J Thorac Cardiovasc Surg 144:584–603PubMedCentralPubMedCrossRef Kirklin JK, Naftel DC, Pagani FD, Kormos RL, Stevenson L, Miller M, Young JB (2012) Long-term mechanical circulatory support (destination therapy): on track to compete with heart transplantation? J Thorac Cardiovasc Surg 144:584–603PubMedCentralPubMedCrossRef
19.
go back to reference Capoccia M, Bowles CT, Sabashnikov A, De Robertis F, Amrani M, Banner NR, Simon A A UK single centre retrospective analysis of the relationship between haemodynamic changes and outcome in patients undergoing prolonged left ventricular assist device support Ann Thorac Cardiovasc Surg (in press) Capoccia M, Bowles CT, Sabashnikov A, De Robertis F, Amrani M, Banner NR, Simon A A UK single centre retrospective analysis of the relationship between haemodynamic changes and outcome in patients undergoing prolonged left ventricular assist device support Ann Thorac Cardiovasc Surg (in press)
20.
go back to reference McCarthy PM, Wang N, Vargo R (1994) Preperitoneal insertion of the HeartMate 1000 IP implantable left ventricular assist device. Ann Thorac Surg 57:634–637PubMedCrossRef McCarthy PM, Wang N, Vargo R (1994) Preperitoneal insertion of the HeartMate 1000 IP implantable left ventricular assist device. Ann Thorac Surg 57:634–637PubMedCrossRef
21.
go back to reference Frazier OH, Myers TJ, Westaby S, Gregoric ID (2003) Use of the Jarvik 2000 left ventricular assist system as a bridge to heart transplantation or as destination therapy for patients with chronic heart failure. Ann Surg 237:631–636PubMedCentralPubMed Frazier OH, Myers TJ, Westaby S, Gregoric ID (2003) Use of the Jarvik 2000 left ventricular assist system as a bridge to heart transplantation or as destination therapy for patients with chronic heart failure. Ann Surg 237:631–636PubMedCentralPubMed
22.
go back to reference Farrar DJ (2000) The thoratec ventricular assist device: a paracorporeal pump for treating acute and chronic heart failure. Semin Thorac Cardiovasc Surg 12:243–250PubMedCrossRef Farrar DJ (2000) The thoratec ventricular assist device: a paracorporeal pump for treating acute and chronic heart failure. Semin Thorac Cardiovasc Surg 12:243–250PubMedCrossRef
23.
go back to reference Sharples L, Buxton M, Caine N, Cafferty F, Demeris N, Dyer M, Freeman C (2005) Evaluation of VAD programme in the UK (EVAD). Final Report to NHS R&D HTA Programme Sharples L, Buxton M, Caine N, Cafferty F, Demeris N, Dyer M, Freeman C (2005) Evaluation of VAD programme in the UK (EVAD). Final Report to NHS R&D HTA Programme
24.
go back to reference Frazier OH, Myers TJ (1999) Left ventricular assist system as a bridge to myocardial recovery. Ann Thorac Surg 68(2):734–741PubMedCrossRef Frazier OH, Myers TJ (1999) Left ventricular assist system as a bridge to myocardial recovery. Ann Thorac Surg 68(2):734–741PubMedCrossRef
25.
go back to reference Dandel M, Weng Y, Siniawski H, Potapov E, Lehmkuhl HB, Hetzer R (2005) Long-term results in patients with idiopathic dilated cardiomyopathy after weaning from left ventricular assist devices. Circulation 112(9 Suppl):I37–I45PubMed Dandel M, Weng Y, Siniawski H, Potapov E, Lehmkuhl HB, Hetzer R (2005) Long-term results in patients with idiopathic dilated cardiomyopathy after weaning from left ventricular assist devices. Circulation 112(9 Suppl):I37–I45PubMed
26.
go back to reference Yacoub MH, Birks EJ, Tansley PD, Henien MY, Bowles C (2001) Bridge to recovery: the harefield approach. J Congest Heart Fail Circ Support 2(1):27–30CrossRef Yacoub MH, Birks EJ, Tansley PD, Henien MY, Bowles C (2001) Bridge to recovery: the harefield approach. J Congest Heart Fail Circ Support 2(1):27–30CrossRef
27.
go back to reference Birks EJ, Tansley PD, Hardy J, George RS, Bowles CT, Burke M, Banner NR, Khaghani A, Yacoub MH (2006) Left ventricular assist device and drug therapy for the reversal of heart failure. N Engl J Med 355(18):1873–1884PubMedCrossRef Birks EJ, Tansley PD, Hardy J, George RS, Bowles CT, Burke M, Banner NR, Khaghani A, Yacoub MH (2006) Left ventricular assist device and drug therapy for the reversal of heart failure. N Engl J Med 355(18):1873–1884PubMedCrossRef
28.
go back to reference Birks EJ, George RS, Hedger M, Bahrami T, Wilton P, Bowles CT, Webb C, Bougard R, Amrani M, Yacoub MH, Dreyfus G, Khaghani A (2011) Reversal of severe heart failure with a continuous-flow left ventricular assist device and pharmacological therapy: a prospective study. Circulation 123(4):381–390PubMedCrossRef Birks EJ, George RS, Hedger M, Bahrami T, Wilton P, Bowles CT, Webb C, Bougard R, Amrani M, Yacoub MH, Dreyfus G, Khaghani A (2011) Reversal of severe heart failure with a continuous-flow left ventricular assist device and pharmacological therapy: a prospective study. Circulation 123(4):381–390PubMedCrossRef
29.
go back to reference Aaronson KD, Pagani FD, Maybaum SW, Feldman DS, Bogaev RC, O’Connell JB, Boyce SW, McGee EW, Sun BC, Goldstein DJ, Frazier OH, Myles JD, Weatherwax KJ, Basobas L, McGowan L, Farrar DJ, Yacoub MH, Birks EJ, Miller LW (2011) Combination therapy with pulsatile left ventricular assist device, heart failure medication and clenbuterol in chronic heart failure: results from harps. J Heart Lung Transplant 30(4):S8–S9CrossRef Aaronson KD, Pagani FD, Maybaum SW, Feldman DS, Bogaev RC, O’Connell JB, Boyce SW, McGee EW, Sun BC, Goldstein DJ, Frazier OH, Myles JD, Weatherwax KJ, Basobas L, McGowan L, Farrar DJ, Yacoub MH, Birks EJ, Miller LW (2011) Combination therapy with pulsatile left ventricular assist device, heart failure medication and clenbuterol in chronic heart failure: results from harps. J Heart Lung Transplant 30(4):S8–S9CrossRef
30.
go back to reference Cardiac MaybaumS, Support RecoveryDuringContinuous-FlowLeftVentricularAssistDevice (2011) Some good news from across the Atlantic. Circulation 123:355–357CrossRef Cardiac MaybaumS, Support RecoveryDuringContinuous-FlowLeftVentricularAssistDevice (2011) Some good news from across the Atlantic. Circulation 123:355–357CrossRef
31.
go back to reference Drakos SG, Kfoury AG, Stehlik J, Selzman CH, Reid BB, Terrovitis JV, Nanas JN, Li DY (2012) Bridge to recovery. Understanding the disconnect between clinical and biological outcomes. Circulation 126:230–241PubMedCentralPubMedCrossRef Drakos SG, Kfoury AG, Stehlik J, Selzman CH, Reid BB, Terrovitis JV, Nanas JN, Li DY (2012) Bridge to recovery. Understanding the disconnect between clinical and biological outcomes. Circulation 126:230–241PubMedCentralPubMedCrossRef
32.
go back to reference Moulopoulos S, Topaz S, Kolff W (1962) Diastolic balloon pumping (with carbon dioxide) in the aorta. A mechanical assistance for the failing circulation. Am Heart J 63:699CrossRef Moulopoulos S, Topaz S, Kolff W (1962) Diastolic balloon pumping (with carbon dioxide) in the aorta. A mechanical assistance for the failing circulation. Am Heart J 63:699CrossRef
33.
go back to reference Kantrowitz A, Cardona RR, Freed PS (1993) Weaning from the intra-aortic balloon pump. In: Qaal SJ (ed) Comprehensive intra-aortic balloon counterpulsation, 2nd edn. Mosby, Saint Louis, pp 398–407 Kantrowitz A, Cardona RR, Freed PS (1993) Weaning from the intra-aortic balloon pump. In: Qaal SJ (ed) Comprehensive intra-aortic balloon counterpulsation, 2nd edn. Mosby, Saint Louis, pp 398–407
34.
go back to reference Kern MJ (1991) Intra-aortic balloon counterpulsation. Coron Artery Disease 2:649–660 Kern MJ (1991) Intra-aortic balloon counterpulsation. Coron Artery Disease 2:649–660
35.
go back to reference Scanlon PJ, O’Connell J, Johnson SA, Moran JM, Gunnar R, Pifarre R (1976) Balloon counterpulsation following surgery for ischemic heart disease. Circulation 54:90–93 Scanlon PJ, O’Connell J, Johnson SA, Moran JM, Gunnar R, Pifarre R (1976) Balloon counterpulsation following surgery for ischemic heart disease. Circulation 54:90–93
36.
go back to reference Weber KT, Janicki JS (1974) Intra-aortic balloon counterpulsation: a review of physiological principles, clinical results, and device safety. Ann Thorac Surg 17:602–636PubMedCrossRef Weber KT, Janicki JS (1974) Intra-aortic balloon counterpulsation: a review of physiological principles, clinical results, and device safety. Ann Thorac Surg 17:602–636PubMedCrossRef
37.
go back to reference Bolooki H (1998) Clinical application of the intra-aortic balloon pump, 3rd edn. Futura, New York, pp 1–20 Bolooki H (1998) Clinical application of the intra-aortic balloon pump, 3rd edn. Futura, New York, pp 1–20
38.
go back to reference Khir AW, Price S, Hale C, Young DA, Parker KH, Pepper JR (2005) Intra-aortic balloon pumping: does posture matter? Artif Organs 29(1):36–40PubMedCrossRef Khir AW, Price S, Hale C, Young DA, Parker KH, Pepper JR (2005) Intra-aortic balloon pumping: does posture matter? Artif Organs 29(1):36–40PubMedCrossRef
39.
go back to reference Biglino G, Whitehorne M, Pepper JR, Khir AW (2008) Pressure and flow volume distribution associated with intra-aortic balloon inflation: an in vitro study. Artif Organs 32(1):19–27PubMed Biglino G, Whitehorne M, Pepper JR, Khir AW (2008) Pressure and flow volume distribution associated with intra-aortic balloon inflation: an in vitro study. Artif Organs 32(1):19–27PubMed
40.
go back to reference Biglino G, Kolyva C, Whitehorne M, Pepper JR, Khir AW (2010) Variations in aortic pressure affect the mechanics of the intra-aortic balloon: an in vitro investigation. Artif Organs 34(7):546–553PubMedCrossRef Biglino G, Kolyva C, Whitehorne M, Pepper JR, Khir AW (2010) Variations in aortic pressure affect the mechanics of the intra-aortic balloon: an in vitro investigation. Artif Organs 34(7):546–553PubMedCrossRef
41.
go back to reference Scheidt S, Wilner G, Mueller H, Summers D, Lesch M, Wolff G, Krakauer J, Rubenfire M, Fleming P, Noon G, Oldham N, Killip T, Kantrowitz A (1973) Intra-aortic balloon counterpulsation in cardiogenic shock. N Engl J Med 288:979–984PubMedCrossRef Scheidt S, Wilner G, Mueller H, Summers D, Lesch M, Wolff G, Krakauer J, Rubenfire M, Fleming P, Noon G, Oldham N, Killip T, Kantrowitz A (1973) Intra-aortic balloon counterpulsation in cardiogenic shock. N Engl J Med 288:979–984PubMedCrossRef
42.
go back to reference Dunkman WB, Leinbach RC, Buckley MJ, Mundth ED, Kantrowitz AR, Austen WG, Sanders CA (1972) Clinical and haemodynamic results of intra-aortic balloon pumping and surgery for cardiogenic shock. Circulation 47:465–477CrossRef Dunkman WB, Leinbach RC, Buckley MJ, Mundth ED, Kantrowitz AR, Austen WG, Sanders CA (1972) Clinical and haemodynamic results of intra-aortic balloon pumping and surgery for cardiogenic shock. Circulation 47:465–477CrossRef
43.
go back to reference Stefanadis C, Dernellis J, Tsiamis E, Stratos C, Kallikazaros I, Toutouzas P (1998) Aortyic function in patients during intra-aortic balloon pumping determined by the pressure-diameter relation. J Thorac Cardiovasc Surg 116:1052–1059PubMedCrossRef Stefanadis C, Dernellis J, Tsiamis E, Stratos C, Kallikazaros I, Toutouzas P (1998) Aortyic function in patients during intra-aortic balloon pumping determined by the pressure-diameter relation. J Thorac Cardiovasc Surg 116:1052–1059PubMedCrossRef
44.
go back to reference Khir AW, Price S, Henein MY, Parker KH, Pepper JR (2003) Intra-aortic balloon pumping: effects on left ventricular diastolic function. Eur J Cardiothorac Surg 24:277–282PubMedCrossRef Khir AW, Price S, Henein MY, Parker KH, Pepper JR (2003) Intra-aortic balloon pumping: effects on left ventricular diastolic function. Eur J Cardiothorac Surg 24:277–282PubMedCrossRef
45.
go back to reference Freedman RJ (1991) The intra-aortic balloon pump system: current roles and future directions. J Appl Cardiol 6:313 Freedman RJ (1991) The intra-aortic balloon pump system: current roles and future directions. J Appl Cardiol 6:313
46.
go back to reference Hilberman M (1981) Effect of the intra-aortic balloon pump on post-operative renal function in man. Crit Care Med 9:85PubMedCrossRef Hilberman M (1981) Effect of the intra-aortic balloon pump on post-operative renal function in man. Crit Care Med 9:85PubMedCrossRef
47.
go back to reference Urschel CW, Eber L, Forrester J, Matloff J, Carpenter R, Sonnenblick E (1970) Alteration of mechanical performance of the ventricle by intra-aortic balloon counterpulsation. Am J Cardiol 25:546–551PubMedCrossRef Urschel CW, Eber L, Forrester J, Matloff J, Carpenter R, Sonnenblick E (1970) Alteration of mechanical performance of the ventricle by intra-aortic balloon counterpulsation. Am J Cardiol 25:546–551PubMedCrossRef
48.
go back to reference Port SC, Patel S, Schmidt DH (1984) Effects of intra-aortic balloon counterpulsation on myocardial blood flow in patients with severe coronary artery disease. J Am Coll Cardiol 3:367–374CrossRef Port SC, Patel S, Schmidt DH (1984) Effects of intra-aortic balloon counterpulsation on myocardial blood flow in patients with severe coronary artery disease. J Am Coll Cardiol 3:367–374CrossRef
49.
go back to reference Leinbach RC, Buckley MJ, Austen WG, Petschek HE, Kantrowitz AR, Sanders CA (1971) Effects of intra-aortic balloon pumping on coronary flow and metabolism in man. Circulation 43:I-77–I-81CrossRef Leinbach RC, Buckley MJ, Austen WG, Petschek HE, Kantrowitz AR, Sanders CA (1971) Effects of intra-aortic balloon pumping on coronary flow and metabolism in man. Circulation 43:I-77–I-81CrossRef
50.
go back to reference Williams DO, Korr KS, Gewirtz H, Most AS (1982) The effect of intra-aortic balloon counterpulsation on regional myocardial blood flow and oxygen consumption in the presence of coronary artery stenosis in patients with unstable angina. Circulation 66:593–597PubMedCrossRef Williams DO, Korr KS, Gewirtz H, Most AS (1982) The effect of intra-aortic balloon counterpulsation on regional myocardial blood flow and oxygen consumption in the presence of coronary artery stenosis in patients with unstable angina. Circulation 66:593–597PubMedCrossRef
51.
go back to reference Bregman D, Parodi EN, Reemtsma K, Malm JR (1975) Advances in clinical intra-aortic balloon pumping. In: Norman IC, Lawrence EP, Cooper T (eds) Coronary artery medicine and surgery: concepts and controversies. Appleton-Century-Crofts, New York, p 413 Bregman D, Parodi EN, Reemtsma K, Malm JR (1975) Advances in clinical intra-aortic balloon pumping. In: Norman IC, Lawrence EP, Cooper T (eds) Coronary artery medicine and surgery: concepts and controversies. Appleton-Century-Crofts, New York, p 413
52.
go back to reference Whittle JL, Feldman RL, Pepine CJ, Nichols WW, Selby J, Kelly T, Conti TR (1980) Effects of intra-aortic balloon pumping on regional and total coronary flow in patients with coronary disease. Am J Cardiol 45:395–401CrossRef Whittle JL, Feldman RL, Pepine CJ, Nichols WW, Selby J, Kelly T, Conti TR (1980) Effects of intra-aortic balloon pumping on regional and total coronary flow in patients with coronary disease. Am J Cardiol 45:395–401CrossRef
53.
go back to reference Kolyva C, Pantalos GM, Pepper JR, Khir AW (2010) How much of the intra-aortic balloon volume is displaced toward the coronary circulation? J Thorac Cardiovasc Surg 140:110–116PubMedCentralPubMedCrossRef Kolyva C, Pantalos GM, Pepper JR, Khir AW (2010) How much of the intra-aortic balloon volume is displaced toward the coronary circulation? J Thorac Cardiovasc Surg 140:110–116PubMedCentralPubMedCrossRef
54.
go back to reference Kolyva C, Pantalos GM, Giridharan GA, Pepper JR, Khir AW (2009) Discerning aortic waves during intra-aortic balloon pumping and their relation to benefits of counterpulsation in humans. J Appl Physiol 107:1497–1503PubMedCentralPubMedCrossRef Kolyva C, Pantalos GM, Giridharan GA, Pepper JR, Khir AW (2009) Discerning aortic waves during intra-aortic balloon pumping and their relation to benefits of counterpulsation in humans. J Appl Physiol 107:1497–1503PubMedCentralPubMedCrossRef
55.
go back to reference Lu PJ, Yang CFJ, Wu MY, Hung CH, Chan MY, Hsu TC (2011) Wave energy patterns of counterpulsation: a novel approach with wave intensity analysis. J Thorac Cardiovasc Surg 142:1205–1213PubMedCrossRef Lu PJ, Yang CFJ, Wu MY, Hung CH, Chan MY, Hsu TC (2011) Wave energy patterns of counterpulsation: a novel approach with wave intensity analysis. J Thorac Cardiovasc Surg 142:1205–1213PubMedCrossRef
56.
go back to reference Parker KH, Jones CJH (1990) Forward and backward running waves in the arteries: analysis using the method of characteristics. J Biomed Eng 112:322–326 Parker KH, Jones CJH (1990) Forward and backward running waves in the arteries: analysis using the method of characteristics. J Biomed Eng 112:322–326
57.
go back to reference Bleasdale RA, Parker KH, Jones CJH (2003) Chasing the wave. Unfashionable but important new concepts in arterial wave travel. Am J Physiol Heart Circ Physiol 284:H1879–H1885PubMedCrossRef Bleasdale RA, Parker KH, Jones CJH (2003) Chasing the wave. Unfashionable but important new concepts in arterial wave travel. Am J Physiol Heart Circ Physiol 284:H1879–H1885PubMedCrossRef
58.
go back to reference Flewitt JA, Hobson TN, Wang J Jr, Johnston CR, Shrive NG, Belenkie I, Parker KH, Tyberg JV (2007) Wave intensity analysis of left ventricular filling: application of windkessel theory. Am J Physiol Heart Circ Physiol 292(6):H2817–H2823PubMedCrossRef Flewitt JA, Hobson TN, Wang J Jr, Johnston CR, Shrive NG, Belenkie I, Parker KH, Tyberg JV (2007) Wave intensity analysis of left ventricular filling: application of windkessel theory. Am J Physiol Heart Circ Physiol 292(6):H2817–H2823PubMedCrossRef
59.
go back to reference Feng J, Khir AW (2010) Determination of wave speed and wave separation in the arteries using diameter and velocity. J Biomech 43:455–462PubMedCrossRef Feng J, Khir AW (2010) Determination of wave speed and wave separation in the arteries using diameter and velocity. J Biomech 43:455–462PubMedCrossRef
60.
go back to reference Siniawski H, Lehmkuhl H, Dandel M, Unbehaun A, Kemper D, Weng Y, Hetzer R (2012) Prediction of true decompensation in chronic heart failure for optimal timing of mechanical circulatory support: non-invasive arterial-ventricular coupling. J Funct Biomater 3:100–113PubMedCentralPubMedCrossRef Siniawski H, Lehmkuhl H, Dandel M, Unbehaun A, Kemper D, Weng Y, Hetzer R (2012) Prediction of true decompensation in chronic heart failure for optimal timing of mechanical circulatory support: non-invasive arterial-ventricular coupling. J Funct Biomater 3:100–113PubMedCentralPubMedCrossRef
61.
go back to reference Freed PS, Wasfie T, Zado B, Kantrowitz A (1988) Intra-aortic balloon pumping for prolonged circulatory support. Am J Cardiol 61(8):554–557PubMedCrossRef Freed PS, Wasfie T, Zado B, Kantrowitz A (1988) Intra-aortic balloon pumping for prolonged circulatory support. Am J Cardiol 61(8):554–557PubMedCrossRef
62.
go back to reference Manord JD, Garrard CL, Mehra MR, Sternbergh WC 3rd, Ballinger B, Ventura HO, Stapleton DD, Smart FW, Bowen JC, Money SR (1997) Implications for the vascular surgeon with prolonged (3–89 days) intra-aortic balloon pump counterpulsation. J Vasc Surg 26(3):511–516PubMedCrossRef Manord JD, Garrard CL, Mehra MR, Sternbergh WC 3rd, Ballinger B, Ventura HO, Stapleton DD, Smart FW, Bowen JC, Money SR (1997) Implications for the vascular surgeon with prolonged (3–89 days) intra-aortic balloon pump counterpulsation. J Vasc Surg 26(3):511–516PubMedCrossRef
63.
go back to reference McBride LR, Miller LW, Nauheim KS, Pennington DG (1989) Axillary artery insertion of an intra-aortic balloon pump. Ann Thorac Surg 48:874–875PubMedCrossRef McBride LR, Miller LW, Nauheim KS, Pennington DG (1989) Axillary artery insertion of an intra-aortic balloon pump. Ann Thorac Surg 48:874–875PubMedCrossRef
64.
go back to reference Umakanthan R, Hoff SJ, Solenkova N, Wigger MA, Keebler ME, Lenneman A, Leacche M, DiSalvo TG, Ooi H, Naftilan AJ, Byrne JG, Ahmad RM (2012) Benefits of ambulatory axillary intra-aortic balloon pump for circulatory support as bridge to heart transplant. J Thorac Cardiovasc Surg 143:1193–1197PubMedCrossRef Umakanthan R, Hoff SJ, Solenkova N, Wigger MA, Keebler ME, Lenneman A, Leacche M, DiSalvo TG, Ooi H, Naftilan AJ, Byrne JG, Ahmad RM (2012) Benefits of ambulatory axillary intra-aortic balloon pump for circulatory support as bridge to heart transplant. J Thorac Cardiovasc Surg 143:1193–1197PubMedCrossRef
65.
go back to reference Jeevanandam V, Jayakar DV, Anderson AS, Martin S, Mueller S, Piccione W, Stephenson LW, Hsu J, Freed PS, Kantrowitz A (2001) A permanent implantable IABP to treat heart failure: initial human experience. J Heart Lung Transl 21(1):A105CrossRef Jeevanandam V, Jayakar DV, Anderson AS, Martin S, Mueller S, Piccione W, Stephenson LW, Hsu J, Freed PS, Kantrowitz A (2001) A permanent implantable IABP to treat heart failure: initial human experience. J Heart Lung Transl 21(1):A105CrossRef
66.
go back to reference Jeevanandam V, Jayakar D, Anderson AS, Martin S, Piccione W Jr, Heroux AL, Wynne J, Stephenson LW, Hsu J, Freed PS, Kantrowitz A (2002) circulatory assistance with a permanent implantable IABP: initial human experience. Circulation 106:I-183–I-188CrossRef Jeevanandam V, Jayakar D, Anderson AS, Martin S, Piccione W Jr, Heroux AL, Wynne J, Stephenson LW, Hsu J, Freed PS, Kantrowitz A (2002) circulatory assistance with a permanent implantable IABP: initial human experience. Circulation 106:I-183–I-188CrossRef
67.
go back to reference Jeevanandam V, Chen M, Myren M, Anderson A, Kantrowitz A, Raman J (2007) Permanent circulatory assist device Implantation using counterpulsation. International society of heart and lung tansplantation (poster presentation). 27th Annual meeting, San Francisco, 25–28 April 2007 Jeevanandam V, Chen M, Myren M, Anderson A, Kantrowitz A, Raman J (2007) Permanent circulatory assist device Implantation using counterpulsation. International society of heart and lung tansplantation (poster presentation). 27th Annual meeting, San Francisco, 25–28 April 2007
68.
go back to reference Legget ME, Peters WS, Milsom FP, Clark JS, West TM, French RL, Merry AF (2005) Extra-aortic balloon counterpulsation an intraoperative feasibility study. Circulation 112:I-26–I-31 Legget ME, Peters WS, Milsom FP, Clark JS, West TM, French RL, Merry AF (2005) Extra-aortic balloon counterpulsation an intraoperative feasibility study. Circulation 112:I-26–I-31
69.
go back to reference Hayward CS, Peters WS, Merry AF, Ruygrok PN, Jansz P, O’Driscoll G, Larbalestier RI, Smith JA, Ho B, Legget ME, Milsom FP (2010) Chronic extra-aortic balloon counterpulsation: first-in-human pilot study in end-stage heart failure. J Heart Lung Transplant 29:1427–1432PubMedCrossRef Hayward CS, Peters WS, Merry AF, Ruygrok PN, Jansz P, O’Driscoll G, Larbalestier RI, Smith JA, Ho B, Legget ME, Milsom FP (2010) Chronic extra-aortic balloon counterpulsation: first-in-human pilot study in end-stage heart failure. J Heart Lung Transplant 29:1427–1432PubMedCrossRef
70.
go back to reference Shea ML, Conti CR, Arora RR (2005) An update on enhanced external counterpulsation. Clin Cardiol 28:115–118PubMedCrossRef Shea ML, Conti CR, Arora RR (2005) An update on enhanced external counterpulsation. Clin Cardiol 28:115–118PubMedCrossRef
71.
go back to reference Arora RR, Chou TM, Jain D, Fleishman B, Crawford L, McKieran T, Nesto RW (1999) The multicenter study of enhanced external counterpulsation (MUST-EECP): effect of EECP onexercise-induced myocardial ischemia and anginal episodes. J Am Coll Cardiol 33:1833–1840PubMedCrossRef Arora RR, Chou TM, Jain D, Fleishman B, Crawford L, McKieran T, Nesto RW (1999) The multicenter study of enhanced external counterpulsation (MUST-EECP): effect of EECP onexercise-induced myocardial ischemia and anginal episodes. J Am Coll Cardiol 33:1833–1840PubMedCrossRef
72.
go back to reference Novo G, Bagger JP, Carta A, Koutroulis G, Hall R, Nihoyannopoulos P (2006) Enhanced external counterpulsation for treatment of refractory angina pectoris. J Cardiovasc Med 7:335–339CrossRef Novo G, Bagger JP, Carta A, Koutroulis G, Hall R, Nihoyannopoulos P (2006) Enhanced external counterpulsation for treatment of refractory angina pectoris. J Cardiovasc Med 7:335–339CrossRef
73.
go back to reference Pettersson T, Bondesson S, Cojocaru D, Ohlsson O, Wackenfors A, Edvinsson L (2006) One year follow-up of patients with refractory angina pectoris treated with enhanced external counterpulsation. BMC Cardiovasc Disord 6:28PubMedCentralPubMedCrossRef Pettersson T, Bondesson S, Cojocaru D, Ohlsson O, Wackenfors A, Edvinsson L (2006) One year follow-up of patients with refractory angina pectoris treated with enhanced external counterpulsation. BMC Cardiovasc Disord 6:28PubMedCentralPubMedCrossRef
74.
go back to reference Feldman AM, Silver MA, Francis GS et al (2006) Enhanced external counterpulsation improves exercise tolerance in patients with chronic heart failure. J Am Coll Cardiol 48:1198–1205PubMedCrossRef Feldman AM, Silver MA, Francis GS et al (2006) Enhanced external counterpulsation improves exercise tolerance in patients with chronic heart failure. J Am Coll Cardiol 48:1198–1205PubMedCrossRef
75.
go back to reference Abbottsmith CW, Chung ES, de Varricchione T, Lame PA, Silver MA, Francis GS, Feldman AM (2006) Enhanced external counterpulsation improves exercise duration and peak oxygen consumption in older patients with heart failure: a subgroup analysis of the PEECH trial. Congest Heart Fail 12:307–311PubMedCrossRef Abbottsmith CW, Chung ES, de Varricchione T, Lame PA, Silver MA, Francis GS, Feldman AM (2006) Enhanced external counterpulsation improves exercise duration and peak oxygen consumption in older patients with heart failure: a subgroup analysis of the PEECH trial. Congest Heart Fail 12:307–311PubMedCrossRef
76.
go back to reference Scholz D, Cai W, Schaper W (2001) Arteriogenesis, a new concept of vascular adaptation in occlusive disease. Angiogenesis 4:247–257PubMedCrossRef Scholz D, Cai W, Schaper W (2001) Arteriogenesis, a new concept of vascular adaptation in occlusive disease. Angiogenesis 4:247–257PubMedCrossRef
77.
go back to reference Niebauer J, Cook JP (1996) Cardiovascular effects of exercise: role of endothelial shear stress. J Am Coll Cardiol 28:1652–1660PubMedCrossRef Niebauer J, Cook JP (1996) Cardiovascular effects of exercise: role of endothelial shear stress. J Am Coll Cardiol 28:1652–1660PubMedCrossRef
78.
go back to reference Soran O, Kennard ED, Bart BA, Kelsey SF (2007) Impact of external counterpulsation treatment on emergency department visits and hospitalizations in refractory angina patients with left ventricular dysfunction. Congest Heart Fail 13:36–40PubMedCrossRef Soran O, Kennard ED, Bart BA, Kelsey SF (2007) Impact of external counterpulsation treatment on emergency department visits and hospitalizations in refractory angina patients with left ventricular dysfunction. Congest Heart Fail 13:36–40PubMedCrossRef
79.
go back to reference Soran O, Kennard ED, Kfoury AG, Kelsey SF, Investigators IEPR (2006) Two-year clinical outcomes after enhanced external counterpulsation (EECP) therapy in patients with refractory angina pectoris and left ventricular dysfunction (report from The International EECP Patient Registry). Am J Cardiol 97(1):17–20PubMedCrossRef Soran O, Kennard ED, Kfoury AG, Kelsey SF, Investigators IEPR (2006) Two-year clinical outcomes after enhanced external counterpulsation (EECP) therapy in patients with refractory angina pectoris and left ventricular dysfunction (report from The International EECP Patient Registry). Am J Cardiol 97(1):17–20PubMedCrossRef
80.
go back to reference Silver MA (2006) Mechanisms and evidence for the role of enhanced counterpulsation in heart failure management. Curr Heart Fail Rep 3:25–32PubMedCrossRef Silver MA (2006) Mechanisms and evidence for the role of enhanced counterpulsation in heart failure management. Curr Heart Fail Rep 3:25–32PubMedCrossRef
81.
go back to reference Koenig SC, Spence PA, Pantalos GM, Dowling RD, Litwak KN (2006) Development and early testing of a simple subcutaneous counterpulsation device. ASAIO J 52(4):362–367PubMedCentralPubMedCrossRef Koenig SC, Spence PA, Pantalos GM, Dowling RD, Litwak KN (2006) Development and early testing of a simple subcutaneous counterpulsation device. ASAIO J 52(4):362–367PubMedCentralPubMedCrossRef
82.
go back to reference Koenig SC, Litwak KN, Giridharan GA, Pantalos GM, Dowling RD, Prabhu SD, Slaughter MS, Sobieski MA, Spence PA (2008) Acute hemodynamic efficacy of a 32-ml subcutaneous counterpulsation device in a calf model of diminished cardiac function. ASAIO J 54(6):578–584PubMedCentralPubMedCrossRef Koenig SC, Litwak KN, Giridharan GA, Pantalos GM, Dowling RD, Prabhu SD, Slaughter MS, Sobieski MA, Spence PA (2008) Acute hemodynamic efficacy of a 32-ml subcutaneous counterpulsation device in a calf model of diminished cardiac function. ASAIO J 54(6):578–584PubMedCentralPubMedCrossRef
83.
go back to reference Bartoli CR, Wilson GC, Giridharan GA, Slaughter MS, Sherwood LC, Spence PA, Prabhu SD, Koenig SC (2010) A novel subcutaneous counterpulsation device: acute hemodynamic efficacy during pharmacologically induced hypertension, hypotension, and heart failure. Artif Organs 34(7):537–545PubMedCrossRef Bartoli CR, Wilson GC, Giridharan GA, Slaughter MS, Sherwood LC, Spence PA, Prabhu SD, Koenig SC (2010) A novel subcutaneous counterpulsation device: acute hemodynamic efficacy during pharmacologically induced hypertension, hypotension, and heart failure. Artif Organs 34(7):537–545PubMedCrossRef
84.
go back to reference Giridharan GA, Lederer C, Berthe A, Goubergritis L, Hutzenlaub J, Slaughter MS, Dowling RD, Spence PA, Koenig SC (2011) Flow dynamics of a novel counterpulsation device characterized by CFD and PIV modelling. Med Eng Phys 33(10):1193–1202PubMedCrossRef Giridharan GA, Lederer C, Berthe A, Goubergritis L, Hutzenlaub J, Slaughter MS, Dowling RD, Spence PA, Koenig SC (2011) Flow dynamics of a novel counterpulsation device characterized by CFD and PIV modelling. Med Eng Phys 33(10):1193–1202PubMedCrossRef
85.
go back to reference Giridharan GA, Bartoli CR, Spence PA, Dowling RD, Koenig SC (2012) Counterpulsation with symphony prevents retrograde carotid, aortic, and coronary flows observed with intra-aortic balloon pump support. Artif Organs 36(7):600–606PubMedCrossRef Giridharan GA, Bartoli CR, Spence PA, Dowling RD, Koenig SC (2012) Counterpulsation with symphony prevents retrograde carotid, aortic, and coronary flows observed with intra-aortic balloon pump support. Artif Organs 36(7):600–606PubMedCrossRef
86.
go back to reference Nanas JN, Lolas CT, Charitos CE, Nanas SN, Margari ZJ, Agapitos EV, Moulopoulos SD (1996) A valveless high stroke volume counterpulsation device restores hemodynamics in patients with congestive heart failure and intractable cardiogenic shock awaiting heart transplantation. J Thorac Cardiovasc Surg 111:55–61PubMedCrossRef Nanas JN, Lolas CT, Charitos CE, Nanas SN, Margari ZJ, Agapitos EV, Moulopoulos SD (1996) A valveless high stroke volume counterpulsation device restores hemodynamics in patients with congestive heart failure and intractable cardiogenic shock awaiting heart transplantation. J Thorac Cardiovasc Surg 111:55–61PubMedCrossRef
87.
go back to reference Lu P-J, Yang C-FJ, Wu M-Y, Hung C-H, Chan M-Y, Hsu T-C (2012) Wave intensity analysis of para-aortic counterpulsation. Am J Physiol Heart Circ Physiol 302:H1481–H1491PubMedCrossRef Lu P-J, Yang C-FJ, Wu M-Y, Hung C-H, Chan M-Y, Hsu T-C (2012) Wave intensity analysis of para-aortic counterpulsation. Am J Physiol Heart Circ Physiol 302:H1481–H1491PubMedCrossRef
88.
go back to reference Verkerke B, de Muinck ED, Rakhorst G, Blanksma PK (1993) The PUCA-pump, a left ventricular assist device. Artif Organs 17(5):365–368PubMedCrossRef Verkerke B, de Muinck ED, Rakhorst G, Blanksma PK (1993) The PUCA-pump, a left ventricular assist device. Artif Organs 17(5):365–368PubMedCrossRef
89.
go back to reference Morsink P, Verkerke GJ, Grootenboer HJ, Mihaylov D, Rakhorst G (1997) Numerical modelling of the blood flow behaviour in the valved catheter of the PUCA pump. Int J Artif Organs 20(5):277–284PubMed Morsink P, Verkerke GJ, Grootenboer HJ, Mihaylov D, Rakhorst G (1997) Numerical modelling of the blood flow behaviour in the valved catheter of the PUCA pump. Int J Artif Organs 20(5):277–284PubMed
90.
go back to reference Verkerke GJ, Mihaylov D, Geertsema AAJ, Rakhorst G (1999) Numerical simulation of the pulsating catheter pump: a left ventricular assist device. Artif Organs 23(10):924–931PubMedCrossRef Verkerke GJ, Mihaylov D, Geertsema AAJ, Rakhorst G (1999) Numerical simulation of the pulsating catheter pump: a left ventricular assist device. Artif Organs 23(10):924–931PubMedCrossRef
91.
go back to reference Verkerke GJ, Geertsema AA, Mihaylov D, Blanksma PK, Rakhorst G (2000) Numerical simulation of a left ventricular assist device on the cardiovascular system. Int J Artif Organs 23(11):765–773PubMed Verkerke GJ, Geertsema AA, Mihaylov D, Blanksma PK, Rakhorst G (2000) Numerical simulation of a left ventricular assist device on the cardiovascular system. Int J Artif Organs 23(11):765–773PubMed
92.
go back to reference Rakhorst G, van der Meer J, Kik Ch, Mihaylov D, Havlik P, Trinkl J, Monties JR (1996) Biological evaluation of mechanical circulatory support systems in calves. Int J Artif Organs 19(8):472–476PubMed Rakhorst G, van der Meer J, Kik Ch, Mihaylov D, Havlik P, Trinkl J, Monties JR (1996) Biological evaluation of mechanical circulatory support systems in calves. Int J Artif Organs 19(8):472–476PubMed
93.
go back to reference Mihaylov D, Verkerke GJ, Blanksma PK, Elstrodt J, de Jong ED, Rakhorst G (1999) Evaluation of the optimal driving mode during left ventricular assist with a pulsatile catheter pump in calves. Artif Organs 23(12):1117–1122PubMedCrossRef Mihaylov D, Verkerke GJ, Blanksma PK, Elstrodt J, de Jong ED, Rakhorst G (1999) Evaluation of the optimal driving mode during left ventricular assist with a pulsatile catheter pump in calves. Artif Organs 23(12):1117–1122PubMedCrossRef
94.
go back to reference Mihaylov D, Rakhorst G, van der Plaats A, van Loon JP, Hummel MM, Elstrodt J, Verkerke GJ (2000) In vivo and in vitro experience with the PUCA-II, a single valved pulsatile catheter pump. Int J Artif Organs 23(10):697–702PubMed Mihaylov D, Rakhorst G, van der Plaats A, van Loon JP, Hummel MM, Elstrodt J, Verkerke GJ (2000) In vivo and in vitro experience with the PUCA-II, a single valved pulsatile catheter pump. Int J Artif Organs 23(10):697–702PubMed
95.
go back to reference Mariani MA, Diephuis JC, Kuipers MJH, Gianoli M, Grandjean JG (2007) Off-pump coronary artery bypass graft surgery with a pulsatile catheter pump for left ventricular dysfunction. Ann Thorac Surg 84:690–692PubMedCrossRef Mariani MA, Diephuis JC, Kuipers MJH, Gianoli M, Grandjean JG (2007) Off-pump coronary artery bypass graft surgery with a pulsatile catheter pump for left ventricular dysfunction. Ann Thorac Surg 84:690–692PubMedCrossRef
96.
go back to reference Amico A, Brigiani MS, Vallabini A, Ferrante B, Marzovillo A, Loizzi D, Carbone C (2008) PulseCath, a new short-term ventricular assist device: our experience in off-pump coronary artery bypass graft surgery. J Cardiovasc Med 9:423–426CrossRef Amico A, Brigiani MS, Vallabini A, Ferrante B, Marzovillo A, Loizzi D, Carbone C (2008) PulseCath, a new short-term ventricular assist device: our experience in off-pump coronary artery bypass graft surgery. J Cardiovasc Med 9:423–426CrossRef
97.
go back to reference Arrigoni SC, Kuijpers M, Mecozzi G, Mariani MA (2011) PulseCath® as a right ventricular assist device. Interact CardioVasc Thorac Surg 12:891–894PubMedCrossRef Arrigoni SC, Kuijpers M, Mecozzi G, Mariani MA (2011) PulseCath® as a right ventricular assist device. Interact CardioVasc Thorac Surg 12:891–894PubMedCrossRef
98.
go back to reference Bowles CT, Shah SS, Nishimura K, Clark C, Cumming DVE, Pattison CW, Pepper JR, Jacob MH (1991) Development of mock circulation models for the assessment of counterpulsation systems. Cardiovasc Res 25:901–908PubMedCrossRef Bowles CT, Shah SS, Nishimura K, Clark C, Cumming DVE, Pattison CW, Pepper JR, Jacob MH (1991) Development of mock circulation models for the assessment of counterpulsation systems. Cardiovasc Res 25:901–908PubMedCrossRef
99.
go back to reference Hartnett TM, Gaffney T (1993) Intra-aortic balloon size selection. In: Qaal SJ (ed) Comprehensive intra aortic balloon counterpulsation, 2nd edn. Mosby, Saint Louis, pp 207–214 Hartnett TM, Gaffney T (1993) Intra-aortic balloon size selection. In: Qaal SJ (ed) Comprehensive intra aortic balloon counterpulsation, 2nd edn. Mosby, Saint Louis, pp 207–214
100.
go back to reference Busse R, Bauer RD, Schabert A, Summa Y, Wetterer E (1979) An improved method for the determination of the pulse transmission characteristics of arteries in vivo. Circ Res 44(5):630–636PubMedCrossRef Busse R, Bauer RD, Schabert A, Summa Y, Wetterer E (1979) An improved method for the determination of the pulse transmission characteristics of arteries in vivo. Circ Res 44(5):630–636PubMedCrossRef
101.
go back to reference Bleasdale RA, Parker KH, Jones CJH (2003) Chasing the wave. unfashionable but important new concepts in arterial wave travel. Am J Physiol Heart Circ Physiol 284(6):H1879–H1885PubMedCrossRef Bleasdale RA, Parker KH, Jones CJH (2003) Chasing the wave. unfashionable but important new concepts in arterial wave travel. Am J Physiol Heart Circ Physiol 284(6):H1879–H1885PubMedCrossRef
102.
go back to reference Jones CJH, Parker KH, Hughes R, Sheridan DJ (1992) Nonlinearity of human arterial pulse wave transmission. J Biomech Eng 114(1):10–14PubMedCrossRef Jones CJH, Parker KH, Hughes R, Sheridan DJ (1992) Nonlinearity of human arterial pulse wave transmission. J Biomech Eng 114(1):10–14PubMedCrossRef
103.
go back to reference Hollander EH, Wang JJ, Dobson GM, Parker KH, Tyberg JV (2001) Negative wave reflections in pulmonary arteries. Am J Physiol Heart Circ Physiol 281(2):H895–H902PubMed Hollander EH, Wang JJ, Dobson GM, Parker KH, Tyberg JV (2001) Negative wave reflections in pulmonary arteries. Am J Physiol Heart Circ Physiol 281(2):H895–H902PubMed
104.
go back to reference Sun YH, Anderson TJ, Parker KH, Tyberg JV (2000) Wave-intensity analysis: a new approach to coronary hemodynamics. J Appl Physiol 89(4):1636–1644PubMed Sun YH, Anderson TJ, Parker KH, Tyberg JV (2000) Wave-intensity analysis: a new approach to coronary hemodynamics. J Appl Physiol 89(4):1636–1644PubMed
105.
go back to reference Khir AW, O’Brien A, Gibbs JS, Parker KH (2001) Determination of wave speed and wave separation in the arteries. J Biomech 34(9):1145–1155PubMedCrossRef Khir AW, O’Brien A, Gibbs JS, Parker KH (2001) Determination of wave speed and wave separation in the arteries. J Biomech 34(9):1145–1155PubMedCrossRef
106.
go back to reference Koh TW, Pepper JR, DeSouza AC, Parker KH (1998) Analysis of wave reflections in the arterial system using wave intensity: a novel method for predicting the timing and amplitude of reflected waves. Heart Vessels 13(3):103–113PubMedCrossRef Koh TW, Pepper JR, DeSouza AC, Parker KH (1998) Analysis of wave reflections in the arterial system using wave intensity: a novel method for predicting the timing and amplitude of reflected waves. Heart Vessels 13(3):103–113PubMedCrossRef
107.
go back to reference Niki K, Sugawara M, Chang D, Harada A, Okada T, Sakai R, Uchida K, Tanaka R, Mumford CE (2002) A new noninvasive measurement system for wave intensity: evaluation of carotid arterial wave intensity and reproducibility. Heart Vessels 17:12–21PubMedCrossRef Niki K, Sugawara M, Chang D, Harada A, Okada T, Sakai R, Uchida K, Tanaka R, Mumford CE (2002) A new noninvasive measurement system for wave intensity: evaluation of carotid arterial wave intensity and reproducibility. Heart Vessels 17:12–21PubMedCrossRef
108.
go back to reference Ohte N, Narita H, Sugawara M, Niki K, Okada T, Harada A, Hayano J, Kimura G (2003) Clinical usefulness of carotid arterial wave intensity in assessing left ventricular systolic and early diastolic performance. Heart Vessels 18:107–111PubMedCrossRef Ohte N, Narita H, Sugawara M, Niki K, Okada T, Harada A, Hayano J, Kimura G (2003) Clinical usefulness of carotid arterial wave intensity in assessing left ventricular systolic and early diastolic performance. Heart Vessels 18:107–111PubMedCrossRef
109.
go back to reference Kawaguchi M, Hay I, Fetics B, Kass DA (2003) Combined ventricular systolic and arterial stiffening in patients with heart failure and preserved ejection fraction: implications for systolic and diastolic reserve limitations. Circulation 107:714–720PubMedCrossRef Kawaguchi M, Hay I, Fetics B, Kass DA (2003) Combined ventricular systolic and arterial stiffening in patients with heart failure and preserved ejection fraction: implications for systolic and diastolic reserve limitations. Circulation 107:714–720PubMedCrossRef
110.
go back to reference Friedrich EB, Böhm M (2000) Management of end-stage heart failure. Heart 93:626–631CrossRef Friedrich EB, Böhm M (2000) Management of end-stage heart failure. Heart 93:626–631CrossRef
Metadata
Title
Evidence of clinical efficacy of counterpulsation therapy methods
Authors
M. Capoccia
C. T. Bowles
J. R. Pepper
N. R. Banner
A. R. Simon
Publication date
01-05-2015
Publisher
Springer US
Published in
Heart Failure Reviews / Issue 3/2015
Print ISSN: 1382-4147
Electronic ISSN: 1573-7322
DOI
https://doi.org/10.1007/s10741-014-9468-1

Other articles of this Issue 3/2015

Heart Failure Reviews 3/2015 Go to the issue