Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 1/2019

01-06-2019

Double factor single shot to diminish complications in cryoballoon ablation procedures for atrial fibrillation

Authors: Ermengol Vallès, Begoña Benito, Jesús Jiménez, Sandra Cabrera, Oscar Alcalde, Carmen Altaba, Miguel Angel Guijo, Roger Fan, Julio Martí-Almor

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 1/2019

Login to get access

Abstract

Purpose

Cryoballoon ablation (CBA) has become a standard treatment for recurrent atrial fibrillation (AF). There is need for improved CBA protocols. We aimed to demonstrate that a new protocol including minimum temperature (minT) reached could reduce procedure times and complications.

Methods

A new double factor protocol (DFP), based on the performance of one single shot per vein with variable duration, and conditional bonus shot, determined by time-to-effect (TTE) and minT, was compared with the conventional protocol (CP), with at least two shots per vein. Procedure parameters, complications, and efficacy were compared.

Results

We prospectively included 88 consecutive patients treated with the DFP. These were compared to the previous consecutive 69 patients treated with CP. All procedures were performed with 28-mm second-generation balloon. Acute pulmonary vein (PV) isolation was similar (98.6% vs. 98.9% in CP vs. DFP, p = 0.687). Procedure and ablation times favored DFP over CP (120 vs. 134 min, p = 0.003; and 1051 vs. 1475 s, p < 0.001; respectively). A composite of major and minor complications was significantly reduced in the DFP compared to the CP (18.8% vs. 6.8%, p = 0.02; respectively). Within a follow-up of 18 months, freedom from AF was 79.7% in CP and 78.4% in DFP (Log-rank 0.501). Paroxysmal AF and absence of PV potentials predicted better arrhythmia outcomes (HR 2.14 for paroxysmal vs. persistent, p = 0.031; and HR 1.61 for absence vs. presence of PV potentials, p = 0.01).

Conclusions

The novel DFP results in reduced complication rates and procedure times, with similar success rates compared with a conventional strategy.
Literature
1.
go back to reference Camm AJ, Lip GY, De Caterina R, Savelieva I, Atar D, Hohnloser SH, et al. 2012 focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC Guidelines for the management of atrial fibrillation. Developed with the special contribution of the European Heart Rhythm Association. Eur Heart J. 2012;33(21):2719–47.CrossRefPubMed Camm AJ, Lip GY, De Caterina R, Savelieva I, Atar D, Hohnloser SH, et al. 2012 focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC Guidelines for the management of atrial fibrillation. Developed with the special contribution of the European Heart Rhythm Association. Eur Heart J. 2012;33(21):2719–47.CrossRefPubMed
2.
go back to reference Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, et al. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique. Circulation. 2005;111(2):127–35.CrossRefPubMed Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, et al. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique. Circulation. 2005;111(2):127–35.CrossRefPubMed
3.
go back to reference Cappato R, Negroni S, Pecora D, Bentivegna S, Lupo PP, Carolei A, et al. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation. 2003;108(13):1599–604.CrossRefPubMed Cappato R, Negroni S, Pecora D, Bentivegna S, Lupo PP, Carolei A, et al. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation. 2003;108(13):1599–604.CrossRefPubMed
4.
go back to reference Packer DL, Kowal RC, Wheelan KR, Irwin JM, Champagne J, Guerra PG, et al. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation first results of the North American Arctic Front (STOP AF) pivotal trial. J Am Coll Cardiol. 2013;61:1713–23.CrossRefPubMed Packer DL, Kowal RC, Wheelan KR, Irwin JM, Champagne J, Guerra PG, et al. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation first results of the North American Arctic Front (STOP AF) pivotal trial. J Am Coll Cardiol. 2013;61:1713–23.CrossRefPubMed
5.
go back to reference Di Giovanni G, Wauters K, Chierchia GB, Sieira J, Levinstein M, Conte G, et al. One-year follow-up after single procedure cryoballoon ablation: a comparison between the first and second generation balloon. J Cardiovasc Electrophysiol. 2014;25:834–9.CrossRefPubMed Di Giovanni G, Wauters K, Chierchia GB, Sieira J, Levinstein M, Conte G, et al. One-year follow-up after single procedure cryoballoon ablation: a comparison between the first and second generation balloon. J Cardiovasc Electrophysiol. 2014;25:834–9.CrossRefPubMed
6.
go back to reference Chierchia GB, Di Giovanni G, Ciconte G, de Asmundis C, Conte G, Sieira-Moret J, et al. Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace. 2014;16:639–44.CrossRefPubMed Chierchia GB, Di Giovanni G, Ciconte G, de Asmundis C, Conte G, Sieira-Moret J, et al. Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace. 2014;16:639–44.CrossRefPubMed
7.
go back to reference Schidt M, Dorwarh U, Andresen D, Brachmann J, Kuck KH, Kuniss M, et al. Cryoballoon versus RF ablation in paroxysmal atrial fibrillation: results from the German Ablation Registry. J Cardiovasc Electrophysiol. 2014;25:1–7.CrossRef Schidt M, Dorwarh U, Andresen D, Brachmann J, Kuck KH, Kuniss M, et al. Cryoballoon versus RF ablation in paroxysmal atrial fibrillation: results from the German Ablation Registry. J Cardiovasc Electrophysiol. 2014;25:1–7.CrossRef
8.
go back to reference Kuck KH, Fürnkranz A, Chun KR, Metzner A, Ouyang F, Schlüter M, et al. Cryoballoon or radiofrequency ablation for symptomatic paroxysmal atrial fibrillation: reintervention, rehospitalization, and quality-of-life outcomes in the FIRE AND ICE trial. Eur Heart J. 2016;37(38):2858–65.CrossRefPubMedCentralPubMed Kuck KH, Fürnkranz A, Chun KR, Metzner A, Ouyang F, Schlüter M, et al. Cryoballoon or radiofrequency ablation for symptomatic paroxysmal atrial fibrillation: reintervention, rehospitalization, and quality-of-life outcomes in the FIRE AND ICE trial. Eur Heart J. 2016;37(38):2858–65.CrossRefPubMedCentralPubMed
9.
go back to reference Dubuc M, Roy D, Thibault B, Ducharme A, Tardif JC, Villemaire C, et al. Transvenous catheter ice mapping and cryoablation of the atrioventricular node in dogs. Pacing Clin Electrophysiol. 1999;22(10):1488–98.CrossRefPubMed Dubuc M, Roy D, Thibault B, Ducharme A, Tardif JC, Villemaire C, et al. Transvenous catheter ice mapping and cryoablation of the atrioventricular node in dogs. Pacing Clin Electrophysiol. 1999;22(10):1488–98.CrossRefPubMed
10.
go back to reference Ferrero-de Loma-Osorio A, Izquierdo-de Francisco M, Martínez-Brotons A, Sánchez-Gómez JM, Mascarell-Gregori B, Ruiz-Ros V, et al. Medium-term results of cryoballoon ablation of the pulmonary veins in patients with paroxysmal and persistent atrial fibrillation. First experience of a Spanish center. J Interv Card Electrophysiol. 2013;37(2):189–96.CrossRefPubMed Ferrero-de Loma-Osorio A, Izquierdo-de Francisco M, Martínez-Brotons A, Sánchez-Gómez JM, Mascarell-Gregori B, Ruiz-Ros V, et al. Medium-term results of cryoballoon ablation of the pulmonary veins in patients with paroxysmal and persistent atrial fibrillation. First experience of a Spanish center. J Interv Card Electrophysiol. 2013;37(2):189–96.CrossRefPubMed
11.
go back to reference Aryana A, Kenigsberg DN, Kowalski M, Koo CH, Lim HW, O'Neill PG, et al. Verification of a novel atrial fibrillation cryoablation dosing algorithm guided by time-to-pulmonary vein isolation: results from the Cryo-DOSING study (Cryoballoon-ablation DOSINGBased on the assessment of time-to-effect and pulmonary vein isolation guidance). Heart Rhythm. 2017;14(9):1319–25.CrossRefPubMed Aryana A, Kenigsberg DN, Kowalski M, Koo CH, Lim HW, O'Neill PG, et al. Verification of a novel atrial fibrillation cryoablation dosing algorithm guided by time-to-pulmonary vein isolation: results from the Cryo-DOSING study (Cryoballoon-ablation DOSINGBased on the assessment of time-to-effect and pulmonary vein isolation guidance). Heart Rhythm. 2017;14(9):1319–25.CrossRefPubMed
12.
go back to reference Chun KR, Stich M, Fürnkranz A, Bordignon S, Perrotta L, Dugo D, et al. Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-T trial. Heart Rhythm. 2017;14(4):495–500.CrossRefPubMed Chun KR, Stich M, Fürnkranz A, Bordignon S, Perrotta L, Dugo D, et al. Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-T trial. Heart Rhythm. 2017;14(4):495–500.CrossRefPubMed
13.
go back to reference Ferrero-de-Loma-Osorio Á, García-Fernández A, Castillo-Castillo J, Izquierdo-de-Francisco M, Ibáñez-Críado A, Moreno-Arribas J, et al. Time-to-effect-based dosing strategy for cryoballoon ablation in patients with paroxysmal atrial fibrillation: results of the plusONE multicenter randomized controlled noninferiority trial. Circ Arrhythm Electrophysiol. 2017;10(12). Ferrero-de-Loma-Osorio Á, García-Fernández A, Castillo-Castillo J, Izquierdo-de-Francisco M, Ibáñez-Críado A, Moreno-Arribas J, et al. Time-to-effect-based dosing strategy for cryoballoon ablation in patients with paroxysmal atrial fibrillation: results of the plusONE multicenter randomized controlled noninferiority trial. Circ Arrhythm Electrophysiol. 2017;10(12).
14.
go back to reference Su W, Kowal R, Kowalski M, Metzner A, Svinarich JT, Wheelan K, et al. Best practice guide for cryoballoon ablation in atrial fibrillation: the compilation experience of more than 3000 procedures. Heart Rhythm. 2015;12:1658–66.CrossRefPubMed Su W, Kowal R, Kowalski M, Metzner A, Svinarich JT, Wheelan K, et al. Best practice guide for cryoballoon ablation in atrial fibrillation: the compilation experience of more than 3000 procedures. Heart Rhythm. 2015;12:1658–66.CrossRefPubMed
15.
go back to reference Marti-Almor J, Bazan V, Vallès E, Benito B, Jauregui-Abularach ME, Bruguera-Cortada J. Long-term outcome on cryoballoon ablation of atrial fibrillation in a low-volume center. Rev Esp Cardiol. 67:577–8. Marti-Almor J, Bazan V, Vallès E, Benito B, Jauregui-Abularach ME, Bruguera-Cortada J. Long-term outcome on cryoballoon ablation of atrial fibrillation in a low-volume center. Rev Esp Cardiol. 67:577–8.
16.
go back to reference Martí-Almor J, Jauregui-Abularach ME, Benito B, Vallès E, Bazan V, Sánchez-Font A, et al. Pulmonary hemorrhage after cryoballoon ablation for pulmonary vein isolation in the treatment of atrial fibrillation. Chest. 2014;145:156–7.CrossRefPubMed Martí-Almor J, Jauregui-Abularach ME, Benito B, Vallès E, Bazan V, Sánchez-Font A, et al. Pulmonary hemorrhage after cryoballoon ablation for pulmonary vein isolation in the treatment of atrial fibrillation. Chest. 2014;145:156–7.CrossRefPubMed
17.
go back to reference Fürnkranz A, Bordignon S, Schmidt B, Gunawardene M, Schulte-Hahn B, Urban V, et al. Improved procedural efficacy of pulmonary vein isolation using the novel second-generation cryoballoon. J Cardiovasc Electrophysiol. 2013;24(5):492–7.CrossRefPubMed Fürnkranz A, Bordignon S, Schmidt B, Gunawardene M, Schulte-Hahn B, Urban V, et al. Improved procedural efficacy of pulmonary vein isolation using the novel second-generation cryoballoon. J Cardiovasc Electrophysiol. 2013;24(5):492–7.CrossRefPubMed
18.
go back to reference Metzner A, Heeger CH, Wohlmuth P, Reismann B, Rillig A, Tilz RR, et al. Two-year outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon: lessons from the bonus freeze protocol. Clin Res Cardiol. 2016;105(1):72–8.CrossRefPubMed Metzner A, Heeger CH, Wohlmuth P, Reismann B, Rillig A, Tilz RR, et al. Two-year outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon: lessons from the bonus freeze protocol. Clin Res Cardiol. 2016;105(1):72–8.CrossRefPubMed
19.
go back to reference Reddy VY, Sediva L, Petru J, Skoda J, Chovanec M, Chiltovova Z, et al. Durability of pulmonary vein isolation with cryoballoon ablation: results from the sustained PV isolation with Arctic front advance (SUSPIR) study. J Cardiovasc Electrophysiol. 2015;26(5):493–500.CrossRefPubMed Reddy VY, Sediva L, Petru J, Skoda J, Chovanec M, Chiltovova Z, et al. Durability of pulmonary vein isolation with cryoballoon ablation: results from the sustained PV isolation with Arctic front advance (SUSPIR) study. J Cardiovasc Electrophysiol. 2015;26(5):493–500.CrossRefPubMed
20.
go back to reference Andrade JG, Dubuc M, Guerra PG, Landry E, Coulombe N, Leduc H, et al. Pulmonary vein isolation using a second-generation cryoballoon catheter: a randomized comparison of ablation duration and method of deflation. J Cardiovasc Electrophysiol. 2013;24(6):692–8.CrossRefPubMed Andrade JG, Dubuc M, Guerra PG, Landry E, Coulombe N, Leduc H, et al. Pulmonary vein isolation using a second-generation cryoballoon catheter: a randomized comparison of ablation duration and method of deflation. J Cardiovasc Electrophysiol. 2013;24(6):692–8.CrossRefPubMed
21.
go back to reference Takami M, Lehmann HI, Misiri J, Parker KD, Sarmiento RI, Johnson SB, et al. Impact of freezing time and balloon size on the thermodynamics and isolation efficacy during pulmonary vein isolation using the second generation cryoballoon. Circ Arrhythm Electrophysiol. 2015;8(4):836–45.CrossRefPubMed Takami M, Lehmann HI, Misiri J, Parker KD, Sarmiento RI, Johnson SB, et al. Impact of freezing time and balloon size on the thermodynamics and isolation efficacy during pulmonary vein isolation using the second generation cryoballoon. Circ Arrhythm Electrophysiol. 2015;8(4):836–45.CrossRefPubMed
22.
go back to reference Chierchia GB, Di Giovanni G, Sieira-Moret J, de Asmundis C, Conte G, Rodriguez-Mañero M, et al. Initial experience of three-minute freeze cycles using the second-generation cryoballoon ablation: acute and short-term procedural outcomes. J Interv Card Electrophysiol. 2014;39(2):145–51.CrossRefPubMed Chierchia GB, Di Giovanni G, Sieira-Moret J, de Asmundis C, Conte G, Rodriguez-Mañero M, et al. Initial experience of three-minute freeze cycles using the second-generation cryoballoon ablation: acute and short-term procedural outcomes. J Interv Card Electrophysiol. 2014;39(2):145–51.CrossRefPubMed
23.
go back to reference Ciconte G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Mugnai G, et al. Single 3-minute freeze for second-generation cryoballoon ablation: one-year follow-up after pulmonary vein isolation. Heart Rhythm. 2015;12(4):673–80.CrossRefPubMed Ciconte G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Mugnai G, et al. Single 3-minute freeze for second-generation cryoballoon ablation: one-year follow-up after pulmonary vein isolation. Heart Rhythm. 2015;12(4):673–80.CrossRefPubMed
24.
go back to reference Wissner E, Heeger CH, Grahn H, Reissmann B, Wohlmuth P, Lemes C, et al. One-year clinical success of a “no-bonus” freeze protocol using the second-generation 28 mm Cryoballoon for pulmonary vein isolation. Europace. 2015;17(8):1236–40.CrossRefPubMed Wissner E, Heeger CH, Grahn H, Reissmann B, Wohlmuth P, Lemes C, et al. One-year clinical success of a “no-bonus” freeze protocol using the second-generation 28 mm Cryoballoon for pulmonary vein isolation. Europace. 2015;17(8):1236–40.CrossRefPubMed
25.
go back to reference Miyazaki S, Hachiya H, Nakamura H, Taniguchi H, Takagi T, Hirao K, et al. Pulmonary vein isolation using a second-generation cryoballoon in patients with paroxysmal atrial fibrillation: one-year outcome using a single big-balloon 3-minute freeze technique. J Cardiovasc Electrophysiol. 2016;27(12):1375–80.CrossRefPubMed Miyazaki S, Hachiya H, Nakamura H, Taniguchi H, Takagi T, Hirao K, et al. Pulmonary vein isolation using a second-generation cryoballoon in patients with paroxysmal atrial fibrillation: one-year outcome using a single big-balloon 3-minute freeze technique. J Cardiovasc Electrophysiol. 2016;27(12):1375–80.CrossRefPubMed
26.
go back to reference Tebbenjohanns J, Höfer C, Bergmann L, Dedroogh M, Gaudin D, von Werder A, et al. Shortening of freezing cycles provides equal outcome to standard ablation procedure using second-generation 28 mm cryoballoon after 15-month follow-up. Europace. 2016;18(2):206–10.CrossRefPubMed Tebbenjohanns J, Höfer C, Bergmann L, Dedroogh M, Gaudin D, von Werder A, et al. Shortening of freezing cycles provides equal outcome to standard ablation procedure using second-generation 28 mm cryoballoon after 15-month follow-up. Europace. 2016;18(2):206–10.CrossRefPubMed
27.
go back to reference Ciconte G, Sieira-Moret J, Hacioglu E, Mugnai G, Di Giovanni G, Velagic V, et al. Single 3-minute versus double 4-minute freeze strategy for second-generation cryoballoon ablation: a single-center experience. J Cardiovasc Electrophysiol. 2016;27(7):796–803.CrossRefPubMed Ciconte G, Sieira-Moret J, Hacioglu E, Mugnai G, Di Giovanni G, Velagic V, et al. Single 3-minute versus double 4-minute freeze strategy for second-generation cryoballoon ablation: a single-center experience. J Cardiovasc Electrophysiol. 2016;27(7):796–803.CrossRefPubMed
28.
go back to reference Vallès E, Cabrera S, Alcalde O, Benito B, Jiménez J, Poveda P, et al. Adapted single shot for cryoballoon procedures optimization in atrial fibrillation. Roma: Abstract in Congress of the European Society of Cardiology; 2016. Vallès E, Cabrera S, Alcalde O, Benito B, Jiménez J, Poveda P, et al. Adapted single shot for cryoballoon procedures optimization in atrial fibrillation. Roma: Abstract in Congress of the European Society of Cardiology; 2016.
29.
go back to reference Boveda S, Providência R, Albenque JP, Combes N, Combes S, Hireche H, et al. Real-time assessment of pulmonary veins disconnection during cryoablation of atrial fibrillation: can it be “achieved” in almost all cases? Europace. 2014;16(6):826–33.CrossRefPubMed Boveda S, Providência R, Albenque JP, Combes N, Combes S, Hireche H, et al. Real-time assessment of pulmonary veins disconnection during cryoablation of atrial fibrillation: can it be “achieved” in almost all cases? Europace. 2014;16(6):826–33.CrossRefPubMed
30.
go back to reference Stabile G, Tondo C, Curnis A, Lunati M, Manfrin M, Molon G, et al. Efficacy of cryoballoon ablation in patients with paroxysmal atrial fibrillation without time to pulmonary vein isolation assessment. Int J Cardiol. 2018;18:32170–3 In press. Stabile G, Tondo C, Curnis A, Lunati M, Manfrin M, Molon G, et al. Efficacy of cryoballoon ablation in patients with paroxysmal atrial fibrillation without time to pulmonary vein isolation assessment. Int J Cardiol. 2018;18:32170–3 In press.
Metadata
Title
Double factor single shot to diminish complications in cryoballoon ablation procedures for atrial fibrillation
Authors
Ermengol Vallès
Begoña Benito
Jesús Jiménez
Sandra Cabrera
Oscar Alcalde
Carmen Altaba
Miguel Angel Guijo
Roger Fan
Julio Martí-Almor
Publication date
01-06-2019
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 1/2019
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-018-0483-3

Other articles of this Issue 1/2019

Journal of Interventional Cardiac Electrophysiology 1/2019 Go to the issue