Skip to main content
Top
Published in: Emergency Radiology 2/2018

01-04-2018 | Original Article

Dose monitoring in pediatric and young adult head and cervical spine CT studies at two emergency duty departments

Authors: Hannele Niiniviita, Timo Kiljunen, Minna Huuskonen, Simo Teperi, Jarmo Kulmala

Published in: Emergency Radiology | Issue 2/2018

Login to get access

Abstract

Purpose

As the number of pediatric computed tomography (CT) imaging is increasing, there is a need for real-time radiation dose monitoring and evaluation of the imaging protocols. The aim of this study was to present the imaging data, patient doses, and observations of pediatric and young adult trauma—and routine head CT and cervical spine CT collected by a dose monitoring software.

Methods

Patient age, study date, imaging parameters, and patient dose as volume CT dose index (CTDIvol) and dose length product (DLP) were collected from two emergency departments’ CT scanners for 2-year period. The patients were divided into four age groups (0–5, 6–10, 11–15, and 16–20 years) for statistical analysis and effective dose determination. The 75th percentile doses were evaluated to be used as local diagnostic reference levels (DRLs).

Results

Six hundred fifteen trauma head, 318 routine head, and 592 trauma cervical spine CT studies were assessed. All mean CTDIvol values were statistically lower in hospital B (40.3 ± 12.3, 30.03 ± 11.1, and 6.9 ± 3.1 mGy, respectively) than in hospital A (53.0 ± 12.9, 43.2 ± 8.7, and 18.3 ± 7.3 mGy, respectively). Statistically significant differences were observed on scanning length between hospitals and between CTDIvol values when protocol was updated. The 75th percentiles of trauma cervical spine in hospital B can be used as local DRL. Non-optimized protocols were also revealed in hospital A.

Conclusion

Dose monitoring software offers a valuable tool for evaluating the imaging practices and finding non-optimized protocols.
Appendix
Available only for authorised users
Literature
3.
go back to reference Pearce MS, Salotti JA, Little MP, McHugh K, Lee C, Kim KP, Howe NL, Ronckers CM, Rajaraman P, Craft AW et al Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505. https://doi.org/10.1016/S0140-6736(12)60815-0 Pearce MS, Salotti JA, Little MP, McHugh K, Lee C, Kim KP, Howe NL, Ronckers CM, Rajaraman P, Craft AW et al Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505. https://​doi.​org/​10.​1016/​S0140-6736(12)60815-0
4.
go back to reference Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284CrossRefPubMed Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284CrossRefPubMed
5.
go back to reference UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) (2010) UNSCEAR 2008 Report: sources and effects of ionizing radiation. United Nations, New York UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) (2010) UNSCEAR 2008 Report: sources and effects of ionizing radiation. United Nations, New York
10.
go back to reference International Commission of Radiological Protection (ICRP) (1997) Protection from potential exposures - Application to selected radiation sources. ICRP Publication 76. Ann ICRP 27(2):1–61 International Commission of Radiological Protection (ICRP) (1997) Protection from potential exposures - Application to selected radiation sources. ICRP Publication 76. Ann ICRP 27(2):1–61
13.
14.
go back to reference Janbabanezhad Toori A, Shabestani-Monfared A, Deevband MR, Abdi R, Nabahati M (2015) Dose assessment in computed tomography examination and establishment of local diagnostic reference levels in Mazandaran, Iran. J Biomed Phys Eng 5(4):177–184PubMedPubMedCentral Janbabanezhad Toori A, Shabestani-Monfared A, Deevband MR, Abdi R, Nabahati M (2015) Dose assessment in computed tomography examination and establishment of local diagnostic reference levels in Mazandaran, Iran. J Biomed Phys Eng 5(4):177–184PubMedPubMedCentral
15.
go back to reference Boos J, Meineke A, Rubbert C, Heusch P, Lanzman RS, Aissa J, Antoch G, Kropil P (2016) Cloud-based CT dose monitoring using the DICOM-structured report: fully automated analysis in regard to National Diagnostic Reference Levels. Rofo 188(3):288–294. https://doi.org/10.1055/s-0041-108059 PubMed Boos J, Meineke A, Rubbert C, Heusch P, Lanzman RS, Aissa J, Antoch G, Kropil P (2016) Cloud-based CT dose monitoring using the DICOM-structured report: fully automated analysis in regard to National Diagnostic Reference Levels. Rofo 188(3):288–294. https://​doi.​org/​10.​1055/​s-0041-108059 PubMed
17.
go back to reference International Commission of Radiological Protection (ICRP) (2001) Radiation and your patient: a guide for medical practitioners. Ann ICRP 31:5–31 International Commission of Radiological Protection (ICRP) (2001) Radiation and your patient: a guide for medical practitioners. Ann ICRP 31:5–31
19.
go back to reference Davis PC, Expert Panel on Neurologic Imaging (2007) Head trauma. AJNR Am J Neuroradiol 28:1619–1621PubMed Davis PC, Expert Panel on Neurologic Imaging (2007) Head trauma. AJNR Am J Neuroradiol 28:1619–1621PubMed
20.
go back to reference Rahman SA, Chandrasala S (2014) When to suspect head injury or cervical spine injury in maxillofacial trauma? Dent Res J (Isfahan) 11(3):336–344 Rahman SA, Chandrasala S (2014) When to suspect head injury or cervical spine injury in maxillofacial trauma? Dent Res J (Isfahan) 11(3):336–344
21.
go back to reference Shrimpton PC (2004) Assessment of patient dose in CT. NRPB-PE/1/2004, EC Contract No.: FIGM-CT-2000-20078. Chilton, Oxon Shrimpton PC (2004) Assessment of patient dose in CT. NRPB-PE/1/2004, EC Contract No.: FIGM-CT-2000-20078. Chilton, Oxon
22.
go back to reference Jarvinen H, Seuri R, Kortesniemi M, Lajunen A, Hallinen E, Savikurki-Heikkila P, Laarne P, Perhomaa M, Tyrvainen E (2015) Indication-based national diagnostic reference levels for paediatric CT: a new approach with proposed values. Radiat Prot Dosim 165(1-4):86–90. https://doi.org/10.1093/rpd/ncv044 CrossRef Jarvinen H, Seuri R, Kortesniemi M, Lajunen A, Hallinen E, Savikurki-Heikkila P, Laarne P, Perhomaa M, Tyrvainen E (2015) Indication-based national diagnostic reference levels for paediatric CT: a new approach with proposed values. Radiat Prot Dosim 165(1-4):86–90. https://​doi.​org/​10.​1093/​rpd/​ncv044 CrossRef
29.
go back to reference Shrimpton PC, Hillier MC, Meeson S, Golding SJ (2014) Doses from computed tomography (CT) examinations in the UK—2011 review. PHE-CRCE-013. Chilton, Oxforshire Shrimpton PC, Hillier MC, Meeson S, Golding SJ (2014) Doses from computed tomography (CT) examinations in the UK—2011 review. PHE-CRCE-013. Chilton, Oxforshire
39.
go back to reference Johnston JH, Podberesky DJ, Yoshizumi TT, Angel E, Toncheva G, Larson DB, Egelhoff JC, Anderson-Evans C, Nguyen GB, Barelli A, Alsip C, Salisbury SR, Frush DP (2013) Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT. Pediatr Radiol 43(9):1117–1127. https://doi.org/10.1007/s00247-013-2690-5 CrossRefPubMed Johnston JH, Podberesky DJ, Yoshizumi TT, Angel E, Toncheva G, Larson DB, Egelhoff JC, Anderson-Evans C, Nguyen GB, Barelli A, Alsip C, Salisbury SR, Frush DP (2013) Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT. Pediatr Radiol 43(9):1117–1127. https://​doi.​org/​10.​1007/​s00247-013-2690-5 CrossRefPubMed
40.
go back to reference European Society of Radiology (ESR) (2015) The gentle way, the art of pediatric imaging. Vienna, The ESR – European Society of Radiology European Society of Radiology (ESR) (2015) The gentle way, the art of pediatric imaging. Vienna, The ESR – European Society of Radiology
Metadata
Title
Dose monitoring in pediatric and young adult head and cervical spine CT studies at two emergency duty departments
Authors
Hannele Niiniviita
Timo Kiljunen
Minna Huuskonen
Simo Teperi
Jarmo Kulmala
Publication date
01-04-2018
Publisher
Springer Berlin Heidelberg
Published in
Emergency Radiology / Issue 2/2018
Print ISSN: 1070-3004
Electronic ISSN: 1438-1435
DOI
https://doi.org/10.1007/s10140-017-1571-x

Other articles of this Issue 2/2018

Emergency Radiology 2/2018 Go to the issue