Abstract

DNA quantification is an important step in the molecular genetic analysis of a forensic sample, hopefully providing reliable data on DNA content for a subsequent generation of reproducible STR profiles for identification. For several years, this quantification has usually been done by real-time PCR protocols and meanwhile a variety of assays are commercially available from different companies. The newest one is the PowerQuantTM assay by Promega Inc. which is advertised with the promise that a determined DNA concentration of 0 ng/μl in a forensic sample guarantees the impossibility to achieve true STR results, thus allowing to exclude such samples from STR analysis to save time and money. Thus, the goal of this study was to thoroughly verify the quantification step with regard to its suitability as a screening method. We have evaluated the precision and reliability of four different real-time PCR quantification assays by systematically testing DNA dilutions and forensic samples with various DNA contents. Subsequently, each sample was subjected to the Powerplex® ESX 17 fast kit to determine a reliable cutoff level for exclusion of definitely negative samples from STR analysis. An accurate quantification of different cell line DNA dilutions was not possible with any kit. However, at least the PowerQuantTM assay provided suitable data analyzing forensic samples, whereas in other systems up to 46 % of negative samples still displayed reliable STR analysis results. All in all, the PowerQuantTM assay represents a big step forward, but the evaluation of real-time PCR quantification results has still to be done with great care.
Appendix
Available only for authorised users
Literature
1.
go back to reference Schwark T, Heinrich A, von Wurmb-Schwark N (2011) Genetic identification of highly putrefied bodies using DNA from soft tissues. Int J Legal Med 125:891–894CrossRef Schwark T, Heinrich A, von Wurmb-Schwark N (2011) Genetic identification of highly putrefied bodies using DNA from soft tissues. Int J Legal Med 125:891–894CrossRef
2.
go back to reference Biesecker LG, Bailey-Wilson JE, Ballantyne J, Baum H, Bieber FR, Brenner C, Budowle B, Butler JM, Carmody G, Conneally PM, Duceman B, Eisenberg A, Forman L, Kidd KK, Leclair B, Niezgoda S, Parsons TJ, Pugh E, Shaler R, Sherry ST, Sozer A, Walsh A (2005) Epidemiology. DNA identifications after the 9/11 World Trade Center attack. Science 310:1122–1123CrossRef Biesecker LG, Bailey-Wilson JE, Ballantyne J, Baum H, Bieber FR, Brenner C, Budowle B, Butler JM, Carmody G, Conneally PM, Duceman B, Eisenberg A, Forman L, Kidd KK, Leclair B, Niezgoda S, Parsons TJ, Pugh E, Shaler R, Sherry ST, Sozer A, Walsh A (2005) Epidemiology. DNA identifications after the 9/11 World Trade Center attack. Science 310:1122–1123CrossRef
3.
go back to reference Deng YJ, Li YZ, Yu XG, Li L, Wu DY, Zhou J, Man TY, Yang G, Yan JW, Cai DQ, Wang J, Yang HM, Li SB, Yu J (2005) Preliminary DNA identification for the tsunami victims in Thailand. Genomics Proteomics Bioinformatics 3:143–157CrossRef Deng YJ, Li YZ, Yu XG, Li L, Wu DY, Zhou J, Man TY, Yang G, Yan JW, Cai DQ, Wang J, Yang HM, Li SB, Yu J (2005) Preliminary DNA identification for the tsunami victims in Thailand. Genomics Proteomics Bioinformatics 3:143–157CrossRef
4.
go back to reference Alonso A, Andelinovic S, Martin P, Sutlovic D, Erceg I, Huffine E, de Simon LF, Albarran C, Definis-Gojanovic M, Fernandez-Rodriguez A, Garcia P, Drmic I, Rezic B, Kuret S, Sancho M, Primorac D (2001) DNA typing from skeletal remains: evaluation of multiplex and megaplex STR systems on DNA isolated from bone and teeth samples. Croat Med J 42:260–266PubMed Alonso A, Andelinovic S, Martin P, Sutlovic D, Erceg I, Huffine E, de Simon LF, Albarran C, Definis-Gojanovic M, Fernandez-Rodriguez A, Garcia P, Drmic I, Rezic B, Kuret S, Sancho M, Primorac D (2001) DNA typing from skeletal remains: evaluation of multiplex and megaplex STR systems on DNA isolated from bone and teeth samples. Croat Med J 42:260–266PubMed
5.
go back to reference Butler JM, Shen Y, McCord BR (2003) The development of reduced size STR amplicons as tools for analysis of degraded DNA. J Forensic Sci 48:1054–1964PubMed Butler JM, Shen Y, McCord BR (2003) The development of reduced size STR amplicons as tools for analysis of degraded DNA. J Forensic Sci 48:1054–1964PubMed
6.
go back to reference Grubwieser P, Mühlmann R, Berger B, Niederstätter H, Pavlic M, Parson W (2006) A new “miniSTR-multiplex” displaying reduced amplicon lengths for the analysis of degraded DNA. Int J Legal Med 120:115–120CrossRef Grubwieser P, Mühlmann R, Berger B, Niederstätter H, Pavlic M, Parson W (2006) A new “miniSTR-multiplex” displaying reduced amplicon lengths for the analysis of degraded DNA. Int J Legal Med 120:115–120CrossRef
7.
go back to reference von Wurmb-Schwark N, Preusse-Prange A, Heinrich A, Simeoni E, Bosch T, Schwark T (2009) A new multiplex-PCR comprising autosomal and y-specific STRs and mitochondrial DNA to analyze highly degraded material. Forensic Sci Int: Genetics 3:96–103CrossRef von Wurmb-Schwark N, Preusse-Prange A, Heinrich A, Simeoni E, Bosch T, Schwark T (2009) A new multiplex-PCR comprising autosomal and y-specific STRs and mitochondrial DNA to analyze highly degraded material. Forensic Sci Int: Genetics 3:96–103CrossRef
8.
go back to reference Poetsch M, Kamphausen T, Bajanowski T, Schwark T, von Wurmb-Schwark N (2011) Powerplex® ES versus Powerplex® S5—casework testing of the new screening kit. Forensic Sci Int Genetics 5:57–63CrossRef Poetsch M, Kamphausen T, Bajanowski T, Schwark T, von Wurmb-Schwark N (2011) Powerplex® ES versus Powerplex® S5—casework testing of the new screening kit. Forensic Sci Int Genetics 5:57–63CrossRef
9.
go back to reference Poetsch M, Bayer K, Ergin Z, Milbrath M, Schwark T, von Wurmb-Schwark N (2011) First experiences using the new Powerplex® ESX17 and ESI17 kits in casework analysis and allele frequencies from two different regions in Germany. Int J Legal Med 125:733–739CrossRef Poetsch M, Bayer K, Ergin Z, Milbrath M, Schwark T, von Wurmb-Schwark N (2011) First experiences using the new Powerplex® ESX17 and ESI17 kits in casework analysis and allele frequencies from two different regions in Germany. Int J Legal Med 125:733–739CrossRef
10.
go back to reference Poetsch M, Preusse-Prange A, Schwark T, von Wurmb-Schwark N (2013) The new guidelines for paternity analysis in Germany—how many STR loci are necessary when investigating duo cases? Int J Legal Med 127:731–734CrossRef Poetsch M, Preusse-Prange A, Schwark T, von Wurmb-Schwark N (2013) The new guidelines for paternity analysis in Germany—how many STR loci are necessary when investigating duo cases? Int J Legal Med 127:731–734CrossRef
11.
go back to reference Rerkamnuaychoke B, Chantratita W, Jomsawat U, Thanakitgosate J, Pattanasak N, Rojanasunan P (2000) Comparison of DNA extraction from blood stain and decomposed muscle in STR polymorphism analysis. J Med Assoc Thai 83(Suppl 1):82–88 Rerkamnuaychoke B, Chantratita W, Jomsawat U, Thanakitgosate J, Pattanasak N, Rojanasunan P (2000) Comparison of DNA extraction from blood stain and decomposed muscle in STR polymorphism analysis. J Med Assoc Thai 83(Suppl 1):82–88
12.
go back to reference Pepinski W, Soltyszewski I, Janica J, Skawronska M, Koc-Zorawska E (2002) Comparison of five commercial kits for DNA extraction from human blood, saliva and muscle samples. Rocz Akad Med Bialymst 47:270–275PubMed Pepinski W, Soltyszewski I, Janica J, Skawronska M, Koc-Zorawska E (2002) Comparison of five commercial kits for DNA extraction from human blood, saliva and muscle samples. Rocz Akad Med Bialymst 47:270–275PubMed
13.
go back to reference Köchl S, Niederstätter H, Parson W (2005) DNA extraction and quantitation of forensic samples using the phenol-chloroform method and real-time PCR. Methods Mol Biol 297:13–30PubMed Köchl S, Niederstätter H, Parson W (2005) DNA extraction and quantitation of forensic samples using the phenol-chloroform method and real-time PCR. Methods Mol Biol 297:13–30PubMed
14.
go back to reference Marshall PL, King JL, Budowle B (2015) Utility of amplification enhancers in low copy number DNA analysis. Int J Legal Med 129:43–52CrossRef Marshall PL, King JL, Budowle B (2015) Utility of amplification enhancers in low copy number DNA analysis. Int J Legal Med 129:43–52CrossRef
15.
go back to reference Budowle B, Eisenberg AJ, van Daal A (2009) Validity of low copy number typing and applications to forensic science. Croat Med J 50:207–217CrossRef Budowle B, Eisenberg AJ, van Daal A (2009) Validity of low copy number typing and applications to forensic science. Croat Med J 50:207–217CrossRef
16.
go back to reference McNevin D, Edson J, Robertson J, Austin JJ (2015) Reduced reaction volumes and increased Taq DNA polymerase concentration improve STR profiling outcomes from a real-world low template DNA source: telogen hairs. Forensic Sci Med Pathol 11:326–338CrossRef McNevin D, Edson J, Robertson J, Austin JJ (2015) Reduced reaction volumes and increased Taq DNA polymerase concentration improve STR profiling outcomes from a real-world low template DNA source: telogen hairs. Forensic Sci Med Pathol 11:326–338CrossRef
17.
go back to reference Kamphausen T, Fandel SB, Gutmann JS, Bajanowski T, Poetsch M (2015) Everything clean? Transfer of DNA traces between textiles in the washtub. Int J Legal Med 129:709–714CrossRef Kamphausen T, Fandel SB, Gutmann JS, Bajanowski T, Poetsch M (2015) Everything clean? Transfer of DNA traces between textiles in the washtub. Int J Legal Med 129:709–714CrossRef
18.
go back to reference Helmus J, Bajanowski T, Poetsch M (2015) DNA transfer—a never ending story. A study on scenarios involving a second person as carrier. Int J Legal Med. doi:10.1007/s00414-015-1284-1 Helmus J, Bajanowski T, Poetsch M (2015) DNA transfer—a never ending story. A study on scenarios involving a second person as carrier. Int J Legal Med. doi:10.​1007/​s00414-015-1284-1
19.
go back to reference Von Wurmb-Schwark N, Higuchi R, Fenech AP, Elfstroem C, Meissner C, Oehmichen M, Cortopassi GA (2002) Quantification of human mitochondrial DNA in a real time PCR. Forensic Sci Int 126:34–39CrossRef Von Wurmb-Schwark N, Higuchi R, Fenech AP, Elfstroem C, Meissner C, Oehmichen M, Cortopassi GA (2002) Quantification of human mitochondrial DNA in a real time PCR. Forensic Sci Int 126:34–39CrossRef
20.
go back to reference Alonso A, Martin P, Albarran C, Garcia P, Garcia O, de Simon LF, Carcia-Hirschfeld J, Sancho M, de la Rúa C, Fernández-Piqueras J (2004) Real-time to estimate nuclear and mitochondrial DNA copy number in forensic and ancient DNA studies. Forensic Sci Int 139:141–149CrossRef Alonso A, Martin P, Albarran C, Garcia P, Garcia O, de Simon LF, Carcia-Hirschfeld J, Sancho M, de la Rúa C, Fernández-Piqueras J (2004) Real-time to estimate nuclear and mitochondrial DNA copy number in forensic and ancient DNA studies. Forensic Sci Int 139:141–149CrossRef
21.
go back to reference Green RL, Roinestad IC, Boland C, Hennessy LK (2005) Developmental validation of the quantifiler real-time PCR kits for the quantification of human nuclear DNA samples. J Forensic Sci 50:809–825CrossRef Green RL, Roinestad IC, Boland C, Hennessy LK (2005) Developmental validation of the quantifiler real-time PCR kits for the quantification of human nuclear DNA samples. J Forensic Sci 50:809–825CrossRef
22.
go back to reference LaSalle HE, Duncan G, McCord B (2011) An analysis of single and multi-copy methods for DNA quantitation by real-time polymerase chain reaction. Forensic Sci Int Genet 5:185–193CrossRef LaSalle HE, Duncan G, McCord B (2011) An analysis of single and multi-copy methods for DNA quantitation by real-time polymerase chain reaction. Forensic Sci Int Genet 5:185–193CrossRef
23.
go back to reference Thomas JT, Berlin RM, Barker JM, Dawson Cruz T (2013) Qiagen’s InvestigatorTM Quantiplex kit as a predictor of STR amplification success from low-yield DNA samples. J Forensic Sci 58:1306–1309CrossRef Thomas JT, Berlin RM, Barker JM, Dawson Cruz T (2013) Qiagen’s InvestigatorTM Quantiplex kit as a predictor of STR amplification success from low-yield DNA samples. J Forensic Sci 58:1306–1309CrossRef
24.
go back to reference Cupples CM, Champagne JR, Lewis KE, Cruz TD (2009) STR profiles from DNA samples with “undetected” or low quantifiler results. J Forensic Sci 54:103–107CrossRef Cupples CM, Champagne JR, Lewis KE, Cruz TD (2009) STR profiles from DNA samples with “undetected” or low quantifiler results. J Forensic Sci 54:103–107CrossRef
25.
go back to reference Bulander N, Rolf B (2009) Comparison of the Plexor HY System, Quantifiler and Quantifiler Duo kits using the Roche LightCycler 480 System and the ABI 7900 real time PCR instrument. Forensic Sci Int Genet Suppl 2:104–105CrossRef Bulander N, Rolf B (2009) Comparison of the Plexor HY System, Quantifiler and Quantifiler Duo kits using the Roche LightCycler 480 System and the ABI 7900 real time PCR instrument. Forensic Sci Int Genet Suppl 2:104–105CrossRef
26.
go back to reference DeSalle R, Bonwich E (1996) DNA isolation, manipulation and characterization from old tissues. Genet Eng (N Y) 18:13–32CrossRef DeSalle R, Bonwich E (1996) DNA isolation, manipulation and characterization from old tissues. Genet Eng (N Y) 18:13–32CrossRef
Metadata
Title
Does zero really mean nothing?—first experiences with the new PowerQuantTM system in comparison to established real-time quantification kits
Authors
Micaela Poetsch
Helen Konrad
Janine Helmus
Thomas Bajanowski
Nicole von Wurmb-Schwark
Publication date
01-07-2016
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Legal Medicine / Issue 4/2016
Print ISSN: 0937-9827
Electronic ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-016-1352-1

Other articles of this Issue 4/2016

International Journal of Legal Medicine 4/2016 Go to the issue