Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 3/2013

01-03-2013 | Clinical Research

Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category?

Authors: Stephen M. Howell, MD, Stacey J. Howell, BS, Kyle T. Kuznik, BS, Joe Cohen, Maury L. Hull, PhD

Published in: Clinical Orthopaedics and Related Research® | Issue 3/2013

Login to get access

Abstract

Background

Kinematically aligned TKA restores function by aligning the femoral and tibial components to the normal or prearthritic joint lines of the knee. However, aligning the components to the joint lines of the normal knee also aligns the tibial component in varus, creating concern that varus alignment might result in poor function and early catastrophic failure.

Questions/Purposes

We therefore determined whether function and the incidence of catastrophic failure were different when the tibial component, knee, and limb alignment were in a specified normal range, varus outlier, or valgus outlier.

Methods

We prospectively followed all 198 patients (214 knees) who underwent TKAs between February and October 2008. We treated each knee in this cohort of patients with a kinematically aligned, cruciate-retaining prosthesis implanted using patient-specific guides. From a long-leg scanogram, we measured and categorized alignment of the tibial component as in range (≤ 0°) or a varus outlier (> 0°), alignment of the knee as in range (between −2.5° to −7.4° valgus) or a varus (> −2.5°) or valgus (< −7.4°) outlier, and alignment of the limb as in range (0° ± 3°) or a varus (> 3°) or valgus (< −3°) outlier. We assessed function using the Oxford Knee Score and WOMAC™ score, and reported catastrophic failure as the incidence of revision attributable to loosening, wear, and instability of the femoral or tibial components. The minimum followup was 31 months (mean, 38 months; range, 31–43 months).

Results

The mean Oxford Knee Score of 43 and WOMAC™ score of 92 were similar between the three alignment categories. The incidence of catastrophic failure in each alignment category was zero.

Conclusions

Kinematically aligned TKA restores function without catastrophic failure regardless of the alignment category. Because 75% of patients had their tibial component categorized as a varus outlier and also had high function and a zero incidence of catastrophic failure, the concern that kinematic alignment compromises function and places the components at a high risk for catastrophic failure is unfounded and should be of interest to surgeons committed to cutting the tibia perpendicular to the mechanical axis of the tibia.

Level of Evidence

Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Baker PN, van der Meulen JH, Lewsey J, Gregg PJ. The role of pain and function in determining patient satisfaction after total knee replacement: data from the National Joint Registry for England and Wales. J Bone Joint Surg Br. 2007;89:893–900.PubMedCrossRef Baker PN, van der Meulen JH, Lewsey J, Gregg PJ. The role of pain and function in determining patient satisfaction after total knee replacement: data from the National Joint Registry for England and Wales. J Bone Joint Surg Br. 2007;89:893–900.PubMedCrossRef
2.
go back to reference Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat Award: Is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res. 2012;470:45–53.PubMedCrossRef Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat Award: Is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res. 2012;470:45–53.PubMedCrossRef
3.
go back to reference Bonner TJ, Eardley WG, Patterson P, Gregg PJ. The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Joint Surg Br. 2011;93:1217–1222.PubMedCrossRef Bonner TJ, Eardley WG, Patterson P, Gregg PJ. The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Joint Surg Br. 2011;93:1217–1222.PubMedCrossRef
4.
go back to reference Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res. 2010;468:57–63.PubMedCrossRef Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res. 2010;468:57–63.PubMedCrossRef
5.
go back to reference Dossett HG, Swartz GJ, Estrada NA, Lefevre GW, Kwasman BG. Kinematically versus mechanically aligned total knee arthroplasty. Orthopedics. 2012;35:e160–169.PubMed Dossett HG, Swartz GJ, Estrada NA, Lefevre GW, Kwasman BG. Kinematically versus mechanically aligned total knee arthroplasty. Orthopedics. 2012;35:e160–169.PubMed
6.
go back to reference Eckhoff D, Hogan C, DiMatteo L, Robinson M, Bach J. Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res. 2007;461:238–244.PubMed Eckhoff D, Hogan C, DiMatteo L, Robinson M, Bach J. Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res. 2007;461:238–244.PubMed
7.
go back to reference Eckhoff DG, Bach JM, Spitzer VM, Reinig KD, Bagur MM, Baldini TH, Flannery NM. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am. 2005;87(suppl 2):71–80.PubMedCrossRef Eckhoff DG, Bach JM, Spitzer VM, Reinig KD, Bagur MM, Baldini TH, Flannery NM. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am. 2005;87(suppl 2):71–80.PubMedCrossRef
9.
go back to reference Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG. The axes of rotation of the knee. Clin Orthop Relat Res. 1993;290:259–268.PubMed Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG. The axes of rotation of the knee. Clin Orthop Relat Res. 1993;290:259–268.PubMed
10.
go back to reference Howell SM, Howell SJ, Hull ML. Assessment of the radii of the medial and lateral femoral condyles in varus and valgus knees with osteoarthritis. J Bone Joint Surg Am. 2010;92:98–104.PubMedCrossRef Howell SM, Howell SJ, Hull ML. Assessment of the radii of the medial and lateral femoral condyles in varus and valgus knees with osteoarthritis. J Bone Joint Surg Am. 2010;92:98–104.PubMedCrossRef
11.
go back to reference Howell SM, Hull ML. Kinematic alignment in TKA: definition, surgical technique, and challenging cases. Orthopedic Knowledge Online. 2012;10, Number 7. Howell SM, Hull ML. Kinematic alignment in TKA: definition, surgical technique, and challenging cases. Orthopedic Knowledge Online. 2012;10, Number 7.
12.
go back to reference Howell SM, Hull ML. Kinematically aligned TKA with MRI-based cutting guides. In: Thienpont E, ed. Improving Accuracy in Knee Arthroplasty. New Delhi, India: Jaypee Brothers Medical Publishers (P) Ltd; 2012:207–232. Howell SM, Hull ML. Kinematically aligned TKA with MRI-based cutting guides. In: Thienpont E, ed. Improving Accuracy in Knee Arthroplasty. New Delhi, India: Jaypee Brothers Medical Publishers (P) Ltd; 2012:207–232.
13.
go back to reference Howell SM, Hull ML. Kinematic alignment in total knee arthroplasty. In: Scott WN, ed. Insall and Scott Surgery of the Knee. Philadelphia, PA: Elsevier; 2012:1255–1268.CrossRef Howell SM, Hull ML. Kinematic alignment in total knee arthroplasty. In: Scott WN, ed. Insall and Scott Surgery of the Knee. Philadelphia, PA: Elsevier; 2012:1255–1268.CrossRef
14.
go back to reference Howell SM, Kuznik K, Hull ML, Siston RA. Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics. 2008;31:857–863.PubMedCrossRef Howell SM, Kuznik K, Hull ML, Siston RA. Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics. 2008;31:857–863.PubMedCrossRef
15.
go back to reference Howell SM, Kuznik K, Hull ML, Siston RA. Longitudinal shapes of the tibia and femur are unrelated and variable. Clin Orthop Relat Res. 2010;468:1142–1148.PubMedCrossRef Howell SM, Kuznik K, Hull ML, Siston RA. Longitudinal shapes of the tibia and femur are unrelated and variable. Clin Orthop Relat Res. 2010;468:1142–1148.PubMedCrossRef
16.
go back to reference Howell SM, Rogers SL. Method for quantifying patient expectations and early recovery after total knee arthroplasty. Orthopedics. 2009;32:884–890.PubMedCrossRef Howell SM, Rogers SL. Method for quantifying patient expectations and early recovery after total knee arthroplasty. Orthopedics. 2009;32:884–890.PubMedCrossRef
17.
go back to reference Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE. Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop. 2009;33:1567–1570.PubMedCrossRef Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE. Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop. 2009;33:1567–1570.PubMedCrossRef
18.
go back to reference Klatt BA, Goyal N, Austin MS, Hozack WJ. Custom-Fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty. 2008;23:26–29.PubMedCrossRef Klatt BA, Goyal N, Austin MS, Hozack WJ. Custom-Fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty. 2008;23:26–29.PubMedCrossRef
19.
go back to reference Labek G, Neumann D, Agreiter M, Schuh R, Böhler N. Impact of implant developers on published outcome and reproducibility of cohort-based clinical studies in arthroplasty. J Bone Joint Surg Am. 2011;93(suppl 3):55–61.PubMedCrossRef Labek G, Neumann D, Agreiter M, Schuh R, Böhler N. Impact of implant developers on published outcome and reproducibility of cohort-based clinical studies in arthroplasty. J Bone Joint Surg Am. 2011;93(suppl 3):55–61.PubMedCrossRef
20.
go back to reference Malkani AL, Rand JA, Bryan RS, Wallrichs SL. Total knee arthroplasty with the kinematic condylar prosthesis: a ten-year follow-up study. J Bone Joint Surg Am. 1995;77:423–431.PubMed Malkani AL, Rand JA, Bryan RS, Wallrichs SL. Total knee arthroplasty with the kinematic condylar prosthesis: a ten-year follow-up study. J Bone Joint Surg Am. 1995;77:423–431.PubMed
21.
go back to reference Noble PC, Conditt MA, Cook KF, Mathis KB. The John Insall Award: Patient expectations affect satisfaction with total knee arthroplasty. Clin Orthop Relat Res. 2006;452:35–43.PubMedCrossRef Noble PC, Conditt MA, Cook KF, Mathis KB. The John Insall Award: Patient expectations affect satisfaction with total knee arthroplasty. Clin Orthop Relat Res. 2006;452:35–43.PubMedCrossRef
22.
go back to reference Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL. Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res. 2012;470:895–902.PubMedCrossRef Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL. Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res. 2012;470:895–902.PubMedCrossRef
23.
go back to reference Pandit H, Jenkins C, Gill HS, Barker K, Dodd CA, Murray DW. Minimally invasive Oxford phase 3 unicompartmental knee replacement: results of 1000 cases. J Bone Joint Surg Br. 2011;93:198–204.PubMedCrossRef Pandit H, Jenkins C, Gill HS, Barker K, Dodd CA, Murray DW. Minimally invasive Oxford phase 3 unicompartmental knee replacement: results of 1000 cases. J Bone Joint Surg Br. 2011;93:198–204.PubMedCrossRef
24.
go back to reference Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92:2143–2149.PubMedCrossRef Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92:2143–2149.PubMedCrossRef
25.
go back to reference Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA. The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am. 2011;93:1588–1596.PubMedCrossRef Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA. The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am. 2011;93:1588–1596.PubMedCrossRef
26.
go back to reference Rothwell AG, Hooper GJ, Hobbs A, Frampton CM. An analysis of the Oxford hip and knee scores and their relationship to early joint revision in the New Zealand Joint Registry. J Bone Joint Surg Br. 2010;92:413–418.PubMedCrossRef Rothwell AG, Hooper GJ, Hobbs A, Frampton CM. An analysis of the Oxford hip and knee scores and their relationship to early joint revision in the New Zealand Joint Registry. J Bone Joint Surg Br. 2010;92:413–418.PubMedCrossRef
Metadata
Title
Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category?
Authors
Stephen M. Howell, MD
Stacey J. Howell, BS
Kyle T. Kuznik, BS
Joe Cohen
Maury L. Hull, PhD
Publication date
01-03-2013
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 3/2013
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-012-2613-z

Other articles of this Issue 3/2013

Clinical Orthopaedics and Related Research® 3/2013 Go to the issue

Symposium: Highlights from the First Combined 2011 Meeting of the Musculoskeletal Tumor Society and Connective Tissue Oncology Society

Using the CUSUM Test to Control the Proportion of Inadequate Open Biopsies of Musculoskeletal Tumors

Symposium: Highlights from the First Combined 2011 Meeting of the Musculoskeletal Tumor Society and Connective Tissue Oncology Society

Primary Osseous Tumors of the Hindfoot: Why the Delay in Diagnosis and Should We Be Concerned?