Discrepancy in Optical & Mechanical Method in Coagulation Tests in a Turbid Sample

Authors: Swati Aggarwal, Deepak M. Nayak, Chethan Manohar

Published in: Indian Journal of Hematology and Blood Transfusion | Special Issue 1/2014

Login to get access

Abstract

Automated coagulation analyzers have replaced manual methods to meet the ever-increasing test load in many laboratories. Of the different methods, two distinct methods exist based on optical and mechanical clot detection (magnetic steel ball method). In optical method the detection of clot formation is measured by a change in optical density (OD) of a test sample. Mechanical clot detection technology, involves monitoring the movement of a steel ball within the test solution using a magnetic sensor. There are limited studies comparing both these methods and they have conflicting results regarding the effect of plasma turbidity on the final result. We report a case where a plasma factor (lipemia) caused prolongation of both PT and APTT, as measured by the photo optical method.
Literature
1.
go back to reference Bai B, Christie DJ, Gorman RT, Wu JR (2008) Comparison of optical and mechanical clot detection for routine coagulation testing in a large volume clinical laboratory. Blood Coagul Fibrinolysis 19:569–576PubMedCrossRef Bai B, Christie DJ, Gorman RT, Wu JR (2008) Comparison of optical and mechanical clot detection for routine coagulation testing in a large volume clinical laboratory. Blood Coagul Fibrinolysis 19:569–576PubMedCrossRef
2.
go back to reference Fischer F, Appert-Flory A, Jambou D, Toulon P (2006) Evaluation of the automated coagulation analyzer Sysmex CA-7000. Thromb Res 117:721–729PubMedCrossRef Fischer F, Appert-Flory A, Jambou D, Toulon P (2006) Evaluation of the automated coagulation analyzer Sysmex CA-7000. Thromb Res 117:721–729PubMedCrossRef
3.
go back to reference Nayak MD, Manohar C, Saroja, Patil A (2013) Comparison of photo-optical and mechanical methods for prothrombin time test. Indian J Appl Res 3:457–458 Nayak MD, Manohar C, Saroja, Patil A (2013) Comparison of photo-optical and mechanical methods for prothrombin time test. Indian J Appl Res 3:457–458
4.
go back to reference Quehenberger P, Kapiotis S, Handler S, Ruzicka K, Speiser W (1999) Evaluation of the automated coagulation analyzer SYSMEX CA 6000. Thromb Res 96:65–71PubMedCrossRef Quehenberger P, Kapiotis S, Handler S, Ruzicka K, Speiser W (1999) Evaluation of the automated coagulation analyzer SYSMEX CA 6000. Thromb Res 96:65–71PubMedCrossRef
5.
go back to reference Dorn-Beineke A, Dempfle CE, Bertsch T, Wisser H (2005) Evaluation of the automated coagulation analyzer Sysmex CA-7000. Thromb Res 116:171–179PubMedCrossRef Dorn-Beineke A, Dempfle CE, Bertsch T, Wisser H (2005) Evaluation of the automated coagulation analyzer Sysmex CA-7000. Thromb Res 116:171–179PubMedCrossRef
6.
go back to reference Tekkesin N, Kılınc C (2012) Optical and mechanical clot detection methodologies: a comparison study for routine coagulation testing. J Clin Lab Anal 26:125–129PubMedCrossRef Tekkesin N, Kılınc C (2012) Optical and mechanical clot detection methodologies: a comparison study for routine coagulation testing. J Clin Lab Anal 26:125–129PubMedCrossRef
7.
go back to reference Toh CH, Samis J, Downey C et al (2002) Biphasic transmittance waveform in the APTT coagulation assay is due to the formation of a Ca(++)-dependent complex of C-reactive protein with very-low-density lipoprotein and is a novel marker of impending disseminated intravascular coagulation. Blood 100:2522–2529PubMedCrossRef Toh CH, Samis J, Downey C et al (2002) Biphasic transmittance waveform in the APTT coagulation assay is due to the formation of a Ca(++)-dependent complex of C-reactive protein with very-low-density lipoprotein and is a novel marker of impending disseminated intravascular coagulation. Blood 100:2522–2529PubMedCrossRef
8.
go back to reference Lippi G, Montagnana M, Salvagno GL, Guidi GC (2006) Interference of blood cell lysis on routine coagulation testing. Arch Pathol Lab Med 130:181–184PubMed Lippi G, Montagnana M, Salvagno GL, Guidi GC (2006) Interference of blood cell lysis on routine coagulation testing. Arch Pathol Lab Med 130:181–184PubMed
Metadata
Title
Discrepancy in Optical & Mechanical Method in Coagulation Tests in a Turbid Sample
Authors
Swati Aggarwal
Deepak M. Nayak
Chethan Manohar
Publication date
01-09-2014
Publisher
Springer India
Published in
Indian Journal of Hematology and Blood Transfusion / Issue Special Issue 1/2014
Print ISSN: 0971-4502
Electronic ISSN: 0974-0449
DOI
https://doi.org/10.1007/s12288-014-0438-5

Other articles of this Special Issue 1/2014

Indian Journal of Hematology and Blood Transfusion 1/2014 Go to the issue
Webinar | 19-02-2024 | 17:30 (CET)

Keynote webinar | Spotlight on antibody–drug conjugates in cancer

Antibody–drug conjugates (ADCs) are novel agents that have shown promise across multiple tumor types. Explore the current landscape of ADCs in breast and lung cancer with our experts, and gain insights into the mechanism of action, key clinical trials data, existing challenges, and future directions.

Dr. Véronique Diéras
Prof. Fabrice Barlesi
Developed by: Springer Medicine