Cyclic changes in area- and perimeter-derived effective dimensions of the aortic annulus measured with multislice computed tomography and comparison with metric intraoperative sizing

Authors: Won-Keun Kim, Alexander Meyer, Helge Möllmann, Andreas Rolf, Susanne Möllmann, Johannes Blumenstein, Arnaud Van Linden, Christian W. Hamm, Thomas Walther, Jörg Kempfert

Published in: Clinical Research in Cardiology | Issue 7/2016

Login to get access

Abstract

Aims

Multislice computed tomography (MSCT) is recommended for annular sizing prior to transcatheter aortic valve implantation (TAVI), but it remains unclear whether systolic or diastolic reconstructions should be used and whether the effective annular diameter should be derived by area or perimeter. In this study these different approaches were compared with intraoperative sizing.

Methods

In 52 patients who were evaluated but deemed unsuitable for TAVI, the annulus was measured during conventional surgery using metric sizers (AnnOp) and compared with MSCT measurements (cross-sectional diameter derived by area [AnnAsys, AnnAdia; AnnAmean = (AnnAsys + AnnAdia)/2] and perimeter (AnnPsys, AnnPdia) in systole and diastole). Furthermore, TAVI was simulated based on AnnOp and the impact of the various MSCT approaches on sizing strategy was determined.

Results

The best agreement with AnnOp [mean difference (limits of agreement)] was shown for AnnAmean [0.03 mm (−1.9 to 1.96)], whereas the strongest deviation was noted for AnnPsys [−1.08 mm (−3.01 to 0.86)]. Mean differences between systole and diastole were significant but small: 0.82 mm (3.5 %) for area- and 0.81 mm (3.3 %) for perimeter-derived measurements. Simulation of TAVI revealed the least change of strategy for AnnAmean (76.9 %) as compared with AnnPsys (53.8 %); between AnnAsys and AnnAdia sizing would have been deviant in 17.3 % due to relatively large intraindividual cyclic differences.

Conclusions

AnnAmean demonstrated the best agreement with AnnOp, whereas perimeter-derived measurements were somewhat overestimated. Despite a negligible average difference between systolic and diastolic annular values, in a subset of patients the intraindividual cyclic variability was relatively large and potentially of clinical impact.
Appendix
Available only for authorised users
Literature
2.
go back to reference Blumenstein J, Liebetrau C, Van Linden A et al (2013) Recent advances in transcatheter aortic valve implantation: novel devices and potential shortcomings. Curr Cardiol Rev 9(4):274–280CrossRefPubMedPubMedCentral Blumenstein J, Liebetrau C, Van Linden A et al (2013) Recent advances in transcatheter aortic valve implantation: novel devices and potential shortcomings. Curr Cardiol Rev 9(4):274–280CrossRefPubMedPubMedCentral
3.
go back to reference Jilaihawi H, Kashif M, Fontana G et al (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59(14):1275–1286. doi:10.1016/j.jacc.2011.11.045 (S0735-1097(12)00077-0 [pii]) CrossRefPubMed Jilaihawi H, Kashif M, Fontana G et al (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59(14):1275–1286. doi:10.​1016/​j.​jacc.​2011.​11.​045 (S0735-1097(12)00077-0 [pii]) CrossRefPubMed
4.
go back to reference Van Linden A, Kempfert J, Blumenstein J et al (2013) Prosthesis-patient mismatch after transcatheter aortic valve implantation using the Edwards SAPIEN prosthesis. Thorac Cardiovasc Surg 61(5):414–420. doi:10.1055/s-0032-1311534 CrossRefPubMed Van Linden A, Kempfert J, Blumenstein J et al (2013) Prosthesis-patient mismatch after transcatheter aortic valve implantation using the Edwards SAPIEN prosthesis. Thorac Cardiovasc Surg 61(5):414–420. doi:10.​1055/​s-0032-1311534 CrossRefPubMed
5.
go back to reference Schymik G, Heimeshoff M, Bramlage P et al (2014) Ruptures of the device landing zone in patients undergoing transcatheter aortic valve implantation: an analysis of TAVI Karlsruhe (TAVIK) patients. Clin Res Cardiol 103(11):912–920. doi:10.1007/s00392-014-0729-8 CrossRefPubMed Schymik G, Heimeshoff M, Bramlage P et al (2014) Ruptures of the device landing zone in patients undergoing transcatheter aortic valve implantation: an analysis of TAVI Karlsruhe (TAVIK) patients. Clin Res Cardiol 103(11):912–920. doi:10.​1007/​s00392-014-0729-8 CrossRefPubMed
6.
go back to reference Pontone G, Andreini D, Bartorelli AL et al (2011) Feasibility and accuracy of a comprehensive multidetector computed tomography acquisition for patients referred for balloon-expandable transcatheter aortic valve implantation. Am Heart J 161(6):1106–1113. doi:10.1016/j.ahj.2011.03.003 (S0002-8703(11)00184-0 [pii]) CrossRefPubMed Pontone G, Andreini D, Bartorelli AL et al (2011) Feasibility and accuracy of a comprehensive multidetector computed tomography acquisition for patients referred for balloon-expandable transcatheter aortic valve implantation. Am Heart J 161(6):1106–1113. doi:10.​1016/​j.​ahj.​2011.​03.​003 (S0002-8703(11)00184-0 [pii]) CrossRefPubMed
8.
go back to reference Tops LF, Wood DA, Delgado V et al (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1(3):321–330. doi:10.1016/j.jcmg.2007.12.006 (S1936-878X(08)00031-4 [pii]) CrossRefPubMed Tops LF, Wood DA, Delgado V et al (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1(3):321–330. doi:10.​1016/​j.​jcmg.​2007.​12.​006 (S1936-878X(08)00031-4 [pii]) CrossRefPubMed
9.
go back to reference Bertaso AG, Wong DT, Liew GY et al (2012) Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole. Int J Cardiovasc Imaging 28(8):2091–2098. doi:10.1007/s10554-012-0018-4 CrossRefPubMed Bertaso AG, Wong DT, Liew GY et al (2012) Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole. Int J Cardiovasc Imaging 28(8):2091–2098. doi:10.​1007/​s10554-012-0018-4 CrossRefPubMed
10.
11.
go back to reference Kempfert J, Van Linden A, Lehmkuhl L et al (2012) Aortic annulus sizing: echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing. Eur J Cardiothorac Surg 42(4):627–633 (10.1093/ejcts/ezs064ezs064 [pii]) CrossRefPubMed Kempfert J, Van Linden A, Lehmkuhl L et al (2012) Aortic annulus sizing: echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing. Eur J Cardiothorac Surg 42(4):627–633 (10.1093/ejcts/ezs064ezs064 [pii]) CrossRefPubMed
12.
go back to reference Opolski MP, Kim WK, Liebetrau C et al (2015) Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation. Clin Res Cardiol 104(6):471–480. doi:10.1007/s00392-014-0806-z CrossRefPubMed Opolski MP, Kim WK, Liebetrau C et al (2015) Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation. Clin Res Cardiol 104(6):471–480. doi:10.​1007/​s00392-014-0806-z CrossRefPubMed
13.
17.
go back to reference Murphy DT, Blanke P, Alaamri S et al (2015) Dynamism of the aortic annulus: effect of diastolic versus systolic CT annular measurements on device selection in transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr. doi:10.1016/j.jcct.2015.07.008 Murphy DT, Blanke P, Alaamri S et al (2015) Dynamism of the aortic annulus: effect of diastolic versus systolic CT annular measurements on device selection in transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr. doi:10.​1016/​j.​jcct.​2015.​07.​008
18.
19.
go back to reference Lehmkuhl L, Foldyna B, Von Aspern K et al (2012) Inter-individual variance and cardiac cycle dependency of aortic root dimensions and shape as assessed by ECG-gated multi-slice computed tomography in patients with severe aortic stenosis prior to transcatheter aortic valve implantation: is it crucial for correct sizing? Int J Cardiovasc Imaging. doi:10.1007/s10554-012-0123-4 PubMedCentral Lehmkuhl L, Foldyna B, Von Aspern K et al (2012) Inter-individual variance and cardiac cycle dependency of aortic root dimensions and shape as assessed by ECG-gated multi-slice computed tomography in patients with severe aortic stenosis prior to transcatheter aortic valve implantation: is it crucial for correct sizing? Int J Cardiovasc Imaging. doi:10.​1007/​s10554-012-0123-4 PubMedCentral
21.
go back to reference Hamdan A, Guetta V, Konen E et al (2012) Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol 59(2):119–127. doi:10.1016/j.jacc.2011.09.045 CrossRefPubMed Hamdan A, Guetta V, Konen E et al (2012) Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol 59(2):119–127. doi:10.​1016/​j.​jacc.​2011.​09.​045 CrossRefPubMed
23.
go back to reference Thubrikar M, Piepgrass WC, Shaner TW et al (1981) The design of the normal aortic valve. Am J Physiol 241(6):H795–H801PubMed Thubrikar M, Piepgrass WC, Shaner TW et al (1981) The design of the normal aortic valve. Am J Physiol 241(6):H795–H801PubMed
Metadata
Title
Cyclic changes in area- and perimeter-derived effective dimensions of the aortic annulus measured with multislice computed tomography and comparison with metric intraoperative sizing
Authors
Won-Keun Kim
Alexander Meyer
Helge Möllmann
Andreas Rolf
Susanne Möllmann
Johannes Blumenstein
Arnaud Van Linden
Christian W. Hamm
Thomas Walther
Jörg Kempfert
Publication date
01-07-2016
Publisher
Springer Berlin Heidelberg
Published in
Clinical Research in Cardiology / Issue 7/2016
Print ISSN: 1861-0684
Electronic ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-016-0971-3

Other articles of this Issue 7/2016

Clinical Research in Cardiology 7/2016 Go to the issue