Skip to main content
Top
Published in: European Radiology 6/2016

01-06-2016 | Head and Neck

CT pre-operative planning of a new semi-implantable bone conduction hearing device

Authors: Eric K. C. Law, Kunwar S. S. Bhatia, Willis S. S. Tsang, Michael C. F. Tong, Lin Shi

Published in: European Radiology | Issue 6/2016

Login to get access

Abstract

Purpose

Accommodating a novel semi-implantable bone conduction hearing device within the temporal bone presents challenges for surgical planning. This study describes the utility of CT in pre-operative assessment of such an implant.

Methods

Retrospective review of pre-operative CT, clinical and surgical records of 16 adults considered for device implantation. Radiological suitability was assessed on CT using 3D simulation software. Antero-posterior (AP) dimensions of the mastoid bone and minimum skull thickness were measured. CT planning results were correlated with operative records.

Results

Eight and five candidates were suitable for device placement in the transmastoid and retrosigmoid positions, respectively, and three were radiologically unsuitable. The mean AP diameter of the mastoid cavity was 14.6 mm for the transmastoid group and 4.6 mm for the retrosigmoid group (p < 0.05). Contracted mastoid and/or prior surgery were predisposing factors for unsuitability. Four transmastoid and five retrosigmoid positions required sigmoid sinus/dural depression and/or use of lifts due to insufficient bone capacity.

Conclusion

A high proportion of patients being considered have contracted or operated mastoids, which reduces the feasibility of the transmastoid approach. This finding combined with the complex temporal bone geometry illustrates the importance of careful CT evaluation using 3D software for precise device simulation.

Key points

Preoperative temporal bone CT is essential for determining Bonebridge device suitability.
Mastoid under-pneumatisation and prior mastoidectomy predict a retrosigmoid Bonebridge position.
3D simulation software is recommended for precise device positioning.
Literature
1.
go back to reference Dun CA, Faber HT, de Wolf MJ, Cremers CW, Hol MK (2011) An overview of different systems: the bone-anchored hearing aid. Adv Otorhinolaryngol 71:22–31PubMed Dun CA, Faber HT, de Wolf MJ, Cremers CW, Hol MK (2011) An overview of different systems: the bone-anchored hearing aid. Adv Otorhinolaryngol 71:22–31PubMed
2.
go back to reference Kiringoda R, Lustig LR (2013) A meta-analysis of the complications associated with osseointegrated hearing aids. Otol Neurotol 34:790–794CrossRefPubMed Kiringoda R, Lustig LR (2013) A meta-analysis of the complications associated with osseointegrated hearing aids. Otol Neurotol 34:790–794CrossRefPubMed
3.
go back to reference Barbara M, Perotti M, Gioia B, Volpini L, Monini S (2013) Transcutaneous bone-conduction hearing device: audiological and surgical aspects in a. Acta Otolaryngol 133:1058–1064CrossRefPubMed Barbara M, Perotti M, Gioia B, Volpini L, Monini S (2013) Transcutaneous bone-conduction hearing device: audiological and surgical aspects in a. Acta Otolaryngol 133:1058–1064CrossRefPubMed
4.
go back to reference Canis M, Ihler F, Blum J, Matthias C (2013) CT-assisted navigation for retrosigmoidal implantation of the Bonebridge. HNO 61:1038–1044CrossRefPubMed Canis M, Ihler F, Blum J, Matthias C (2013) CT-assisted navigation for retrosigmoidal implantation of the Bonebridge. HNO 61:1038–1044CrossRefPubMed
5.
go back to reference Huber AM, Sim JH, Xie YZ, Chatzimichalis M, Ullrich O, Röösli C (2013) The Bonebridge: preclinical evaluation of a new transcutaneously-activated bone anchored hearing device. Hear Res 301:93–99CrossRefPubMed Huber AM, Sim JH, Xie YZ, Chatzimichalis M, Ullrich O, Röösli C (2013) The Bonebridge: preclinical evaluation of a new transcutaneously-activated bone anchored hearing device. Hear Res 301:93–99CrossRefPubMed
6.
go back to reference Lo JF, Tsang WS, Yu JY, Ho OY, Ku PK, Tong MC (2014) Contemporary hearing rehabilitation options in patients with aural atresia. Biomed Res Int 2014:761579CrossRefPubMedPubMedCentral Lo JF, Tsang WS, Yu JY, Ho OY, Ku PK, Tong MC (2014) Contemporary hearing rehabilitation options in patients with aural atresia. Biomed Res Int 2014:761579CrossRefPubMedPubMedCentral
7.
go back to reference Plontke SK, Radetzki F, Seiwerth I, Herzog M, Brandt S, Delank KS, Rahne T (2014) Individual computer-assisted 3D planning for surgical placement of a new bone conduction hearing device. Otol Neurotol 35:1251–1257PubMed Plontke SK, Radetzki F, Seiwerth I, Herzog M, Brandt S, Delank KS, Rahne T (2014) Individual computer-assisted 3D planning for surgical placement of a new bone conduction hearing device. Otol Neurotol 35:1251–1257PubMed
8.
go back to reference Tsang WS, Yu JK, Bhatia KS, Wong TK, Tong MC (2013) The Bonebridge semi-implantable bone conduction hearing device: experience in an Asian patient. J Laryngol Otol 127:1214–1221 Tsang WS, Yu JK, Bhatia KS, Wong TK, Tong MC (2013) The Bonebridge semi-implantable bone conduction hearing device: experience in an Asian patient. J Laryngol Otol 127:1214–1221
9.
go back to reference Güldner C, Heinrichs J, Weiß R, Zimmermann AP, Dassinger B, Bien S, Werner JA, Diogo I (2013) Visualisation of the Bonebridge by means of CT and CBCT. Eur J Med Res 18:30CrossRefPubMedPubMedCentral Güldner C, Heinrichs J, Weiß R, Zimmermann AP, Dassinger B, Bien S, Werner JA, Diogo I (2013) Visualisation of the Bonebridge by means of CT and CBCT. Eur J Med Res 18:30CrossRefPubMedPubMedCentral
10.
go back to reference Lassaletta L, Sanchez-Cuadrado I, Muñoz E, Gavilan J (2014) Retrosigmoid implantation of an active bone conduction stimulator in a patient with chronic otitis media. Auris Nasus Larynx 1-4 Lassaletta L, Sanchez-Cuadrado I, Muñoz E, Gavilan J (2014) Retrosigmoid implantation of an active bone conduction stimulator in a patient with chronic otitis media. Auris Nasus Larynx 1-4
11.
go back to reference Lin S, Wang D, Lok KH, Li L, Bhatia KS, Tong MC (2014) Computer-assisted Surgical Planning for Bonebridge Implantation. 4th East Asian Symposium on Otology, Shanghai, China Lin S, Wang D, Lok KH, Li L, Bhatia KS, Tong MC (2014) Computer-assisted Surgical Planning for Bonebridge Implantation. 4th East Asian Symposium on Otology, Shanghai, China
12.
go back to reference Wimmer W, Gerber N, Guignard J, Dubach P, Kompis M, Weber S, Caversaccio M (2015) Topographic bone thickness maps for Bonebridge implantations. Eur Arch Oto-Rhino-Laryngol Off J Eur Fed Oto-Rhino-Laryngol Soc 272:1651–1658CrossRef Wimmer W, Gerber N, Guignard J, Dubach P, Kompis M, Weber S, Caversaccio M (2015) Topographic bone thickness maps for Bonebridge implantations. Eur Arch Oto-Rhino-Laryngol Off J Eur Fed Oto-Rhino-Laryngol Soc 272:1651–1658CrossRef
13.
go back to reference Takumi Y, Matsumoto N, Cho B, Ono H, Mori K, Tsukada K, Ichinose A, Yoshimura H, Iwasaki S, Komune S, Usami S (2014) A clinical experience of 'STAMP' plate-guided Bonebridge implantation. Acta Otolaryngol 134:1042–1046CrossRefPubMedPubMedCentral Takumi Y, Matsumoto N, Cho B, Ono H, Mori K, Tsukada K, Ichinose A, Yoshimura H, Iwasaki S, Komune S, Usami S (2014) A clinical experience of 'STAMP' plate-guided Bonebridge implantation. Acta Otolaryngol 134:1042–1046CrossRefPubMedPubMedCentral
14.
go back to reference Hassepass F, Bulla S, Aschendorff A, Maier W, Traser L, Steinmetz C, Wesarg T, Arndt S (2014) The Bonebridge as a transcutaneous bone conduction hearing system: preliminary surgical and audiological results in children and adolescents. Eur Arch Otorhinolaryngol 272(9):2235-41 Hassepass F, Bulla S, Aschendorff A, Maier W, Traser L, Steinmetz C, Wesarg T, Arndt S (2014) The Bonebridge as a transcutaneous bone conduction hearing system: preliminary surgical and audiological results in children and adolescents. Eur Arch Otorhinolaryngol 272(9):2235-41
Metadata
Title
CT pre-operative planning of a new semi-implantable bone conduction hearing device
Authors
Eric K. C. Law
Kunwar S. S. Bhatia
Willis S. S. Tsang
Michael C. F. Tong
Lin Shi
Publication date
01-06-2016
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 6/2016
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-015-3983-x

Other articles of this Issue 6/2016

European Radiology 6/2016 Go to the issue