Abstract

Background

With the Bonebridge, a new bone-anchored hearing aid has been available since March 2012. The objective of the study was to analyse the visualisation of the implant itself as well as its impact on the representation of the bony structures of the petrosal bone in CT, MRI and cone beam CT (CBCT).

Methods

The Bonebridge was implanted unilaterally in two completely prepared human heads. The radiological imaging by means of CBCT, 64-slice CT, 1.5-T and 3.0-T MRI was conducted both preoperatively and postoperatively. The images were subsequently evaluated from both the ENT medical and nd radiological perspectives.

Results

As anticipated, no visualisation of the implant or of the petrosal bones could be realised on MRI because of the interactive technology and the magnet artefact. In contrast, an excellent evaluability of the implant itself as well as of the surrounding neurovascular structures (sinus sigmoideus, skull base, middle ear, inner ear, inner auditory canal) was exhibited in both the CT and in the CBCT.

Conclusion

The Bonebridge can be excellently imaged with the radiological imaging technologies of CT and CBCT. In the process, CBCT shows discrete advantages in comparison with CT. No relevant restrictions in image quality in the evaluation of the bony structures of the petrosal bones could be seen.
Appendix
Available only for authorised users
Literature
1.
go back to reference Cremers CW, Snik FM, Beynon AJ: Hearing with the bone-anchored hearing aid (BAHA, HC 200) compared to a conventional bone-conduction hearing aid. Clin Otolaryngol Allied Sci 1992, 17: 275–279. 10.1111/j.1365-2273.1992.tb01842.xCrossRefPubMed Cremers CW, Snik FM, Beynon AJ: Hearing with the bone-anchored hearing aid (BAHA, HC 200) compared to a conventional bone-conduction hearing aid. Clin Otolaryngol Allied Sci 1992, 17: 275–279. 10.1111/j.1365-2273.1992.tb01842.xCrossRefPubMed
2.
go back to reference Hol MK, Cremers CW, Coppens-Schellekens W, Snik AF: The BAHA Softband: a new treatment for young children with bilateral congenital aural atresia. Int J Pediatr Otorhinolaryngol 2005, 69: 973–980. 10.1016/j.ijporl.2005.02.010CrossRefPubMed Hol MK, Cremers CW, Coppens-Schellekens W, Snik AF: The BAHA Softband: a new treatment for young children with bilateral congenital aural atresia. Int J Pediatr Otorhinolaryngol 2005, 69: 973–980. 10.1016/j.ijporl.2005.02.010CrossRefPubMed
3.
go back to reference Snik AF, Mylanus EA, Proops DW, Wolfaardt JF, Hodgetts WE, Somers T, Niparko JK, Wazen JJ, Sterkers O, Cremers CW, Tjellstrom A: Consensus statements on the BAHA system: where do we stand at present? Ann Otol Rhinol Laryngol Suppl 2005, 195: 2–12.PubMed Snik AF, Mylanus EA, Proops DW, Wolfaardt JF, Hodgetts WE, Somers T, Niparko JK, Wazen JJ, Sterkers O, Cremers CW, Tjellstrom A: Consensus statements on the BAHA system: where do we stand at present? Ann Otol Rhinol Laryngol Suppl 2005, 195: 2–12.PubMed
4.
go back to reference Verhagen CV, Hol MK, Coppens-Schellekens W, Snik AF, Cremers CW: The Baha Softband: a new treatment for young children with bilateral congenital aural atresia. Int J Pediatr Otorhinolaryngol 2008, 72: 1455–1459. 10.1016/j.ijporl.2008.06.009CrossRefPubMed Verhagen CV, Hol MK, Coppens-Schellekens W, Snik AF, Cremers CW: The Baha Softband: a new treatment for young children with bilateral congenital aural atresia. Int J Pediatr Otorhinolaryngol 2008, 72: 1455–1459. 10.1016/j.ijporl.2008.06.009CrossRefPubMed
5.
go back to reference Federspil PA: [Bone anchored hearing aids (BAHA)]. HNO 2009, 57: 216–222. 10.1007/s00106-009-1887-2CrossRefPubMed Federspil PA: [Bone anchored hearing aids (BAHA)]. HNO 2009, 57: 216–222. 10.1007/s00106-009-1887-2CrossRefPubMed
6.
go back to reference Siau D, Nik H, Hobson JC, Roper AJ, Rothera MP, Green KM: Bone-anchored hearing aids and chronic pain: a long-term complication and a cause for elective implant removal. J Laryngol Otol 2012, 126: 445–449. 10.1017/S0022215112000394CrossRefPubMed Siau D, Nik H, Hobson JC, Roper AJ, Rothera MP, Green KM: Bone-anchored hearing aids and chronic pain: a long-term complication and a cause for elective implant removal. J Laryngol Otol 2012, 126: 445–449. 10.1017/S0022215112000394CrossRefPubMed
7.
go back to reference Ricci G, Della Volpe A, Faralli M, Longari F, Gulla M, Mansi N, Frenguelli A: Results and complications of the Baha system (bone-anchored hearing aid). Eur Arch Otorhinolaryngol 2010, 267: 1539–1545. 10.1007/s00405-010-1293-0CrossRefPubMed Ricci G, Della Volpe A, Faralli M, Longari F, Gulla M, Mansi N, Frenguelli A: Results and complications of the Baha system (bone-anchored hearing aid). Eur Arch Otorhinolaryngol 2010, 267: 1539–1545. 10.1007/s00405-010-1293-0CrossRefPubMed
8.
go back to reference Doshi J, Karagama Y, Buckley D, Johnson I: Observational study of bone-anchored hearing aid infection rates using different post-operative dressings. J Laryngol Otol 2006, 120: 842–844.PubMed Doshi J, Karagama Y, Buckley D, Johnson I: Observational study of bone-anchored hearing aid infection rates using different post-operative dressings. J Laryngol Otol 2006, 120: 842–844.PubMed
9.
go back to reference De Wolf MJ, Hol MK, Mylanus EA, Cremers CW: Bone-anchored hearing aid surgery in older adults: implant loss and skin reactions. Ann Otol Rhinol Laryngol 2009, 118: 525–531.CrossRefPubMed De Wolf MJ, Hol MK, Mylanus EA, Cremers CW: Bone-anchored hearing aid surgery in older adults: implant loss and skin reactions. Ann Otol Rhinol Laryngol 2009, 118: 525–531.CrossRefPubMed
10.
go back to reference Monksfield P, Chapple IL, Matthews JB, Grant MM, Addison O, Reid AP, Proops DW, Sammons RL: Biofilm formation on bone-anchored hearing aids. J Laryngol Otol 2011, 125: 1125–1130. 10.1017/S0022215111002143CrossRefPubMed Monksfield P, Chapple IL, Matthews JB, Grant MM, Addison O, Reid AP, Proops DW, Sammons RL: Biofilm formation on bone-anchored hearing aids. J Laryngol Otol 2011, 125: 1125–1130. 10.1017/S0022215111002143CrossRefPubMed
11.
go back to reference Wazen JJ, Wycherly B, Daugherty J: Complications of bone-anchored hearing devices. Adv Otorhinolaryngol 2011, 71: 63–72.PubMed Wazen JJ, Wycherly B, Daugherty J: Complications of bone-anchored hearing devices. Adv Otorhinolaryngol 2011, 71: 63–72.PubMed
12.
go back to reference Gluth MB, Eager KM, Eikelboom RH, Atlas MD: Long-term benefit perception, complications, and device malfunction rate of bone-anchored hearing aid implantation for profound unilateral sensorineural hearing loss. Otol Neurotol 2010, 31: 1427–1434.PubMed Gluth MB, Eager KM, Eikelboom RH, Atlas MD: Long-term benefit perception, complications, and device malfunction rate of bone-anchored hearing aid implantation for profound unilateral sensorineural hearing loss. Otol Neurotol 2010, 31: 1427–1434.PubMed
13.
go back to reference Hobson JC, Roper AJ, Andrew R, Rothera MP, Hill P, Green KM: Complications of bone-anchored hearing aid implantation. J Laryngol Otol 2009, 124: 132–136.CrossRefPubMed Hobson JC, Roper AJ, Andrew R, Rothera MP, Hill P, Green KM: Complications of bone-anchored hearing aid implantation. J Laryngol Otol 2009, 124: 132–136.CrossRefPubMed
14.
go back to reference Zeitler DM, Herman BS, Snapp HA, Telischi FF, Angeli SI: Ethnic disparity in skin complications following bone-anchored hearing aid implantation. Ann Otol Rhinol Laryngol 2012, 121: 549–554.PubMed Zeitler DM, Herman BS, Snapp HA, Telischi FF, Angeli SI: Ethnic disparity in skin complications following bone-anchored hearing aid implantation. Ann Otol Rhinol Laryngol 2012, 121: 549–554.PubMed
15.
go back to reference Siegert R: Partially implantable bone conduction hearing aids without a percutaneous abutment (Otomag): technique and preliminary clinical results. Adv Otorhinolaryngol 2011, 71: 41–46.PubMed Siegert R: Partially implantable bone conduction hearing aids without a percutaneous abutment (Otomag): technique and preliminary clinical results. Adv Otorhinolaryngol 2011, 71: 41–46.PubMed
16.
go back to reference Offergeld C, Kromeier J, Aschendorff A, Maier W, Klenzner T, Beleites T, Zahnert T, Schipper J, Laszig R: Rotational tomography of the normal and reconstructed middle ear in temporal bones: an experimental study. Eur Arch Otorhinolaryngol 2007, 264: 345–351. 10.1007/s00405-006-0180-1CrossRefPubMed Offergeld C, Kromeier J, Aschendorff A, Maier W, Klenzner T, Beleites T, Zahnert T, Schipper J, Laszig R: Rotational tomography of the normal and reconstructed middle ear in temporal bones: an experimental study. Eur Arch Otorhinolaryngol 2007, 264: 345–351. 10.1007/s00405-006-0180-1CrossRefPubMed
17.
go back to reference Offergeld C, Kromeier J, Merchant SN, Lasurashvili N, Neudert M, Bornitz M, Laszig R, Zahnert T: Experimental investigation of rotational tomography in reconstructed middle ears with clinical implications. Hear Res 2009, 263: 191–197.PubMedCentralCrossRefPubMed Offergeld C, Kromeier J, Merchant SN, Lasurashvili N, Neudert M, Bornitz M, Laszig R, Zahnert T: Experimental investigation of rotational tomography in reconstructed middle ears with clinical implications. Hear Res 2009, 263: 191–197.PubMedCentralCrossRefPubMed
18.
go back to reference Kurzweg T, Dalchow CV, Bremke M, Majdani O, Kureck I, Knecht R, Werner JA, Teymoortash A: The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens. Ear Hear 2011, 31: 413–419.CrossRef Kurzweg T, Dalchow CV, Bremke M, Majdani O, Kureck I, Knecht R, Werner JA, Teymoortash A: The value of digital volume tomography in assessing the position of cochlear implant arrays in temporal bone specimens. Ear Hear 2011, 31: 413–419.CrossRef
19.
go back to reference Teymoortash A, Hamzei S, Murthum T, Eivazi B, Kureck I, Werner JA: Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study. Surg Radiol Anat 2011, 33: 123–128. 10.1007/s00276-010-0713-6CrossRefPubMed Teymoortash A, Hamzei S, Murthum T, Eivazi B, Kureck I, Werner JA: Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study. Surg Radiol Anat 2011, 33: 123–128. 10.1007/s00276-010-0713-6CrossRefPubMed
20.
go back to reference Dalchow C, Weber A, Bien S, Yanagihara N, Werner J: Value of digital volume tomography in patients with conductive hearing loss. Eur Arch Otorhinolaryngol 2006, 263: 92–99. 10.1007/s00405-005-0995-1CrossRefPubMed Dalchow C, Weber A, Bien S, Yanagihara N, Werner J: Value of digital volume tomography in patients with conductive hearing loss. Eur Arch Otorhinolaryngol 2006, 263: 92–99. 10.1007/s00405-005-0995-1CrossRefPubMed
21.
go back to reference Dalchow CV, Weber AL, Yanagihara N, Bien S, Werner JA: Digital volume tomography: radiologic examinations of the temporal bone. AJR Am J Roentgenol 2006, 186: 416–423. 10.2214/AJR.04.1353CrossRefPubMed Dalchow CV, Weber AL, Yanagihara N, Bien S, Werner JA: Digital volume tomography: radiologic examinations of the temporal bone. AJR Am J Roentgenol 2006, 186: 416–423. 10.2214/AJR.04.1353CrossRefPubMed
22.
go back to reference Güldner C, Diogo I, Windfuhr J, Bien S, Teymoortash A, Werner JA, Bremke M: Analysis of the fossa olfactoria using cone beam tomography (CBT). Acta Otolaryngol 2011, 131: 72–78. 10.3109/00016489.2010.506653CrossRefPubMed Güldner C, Diogo I, Windfuhr J, Bien S, Teymoortash A, Werner JA, Bremke M: Analysis of the fossa olfactoria using cone beam tomography (CBT). Acta Otolaryngol 2011, 131: 72–78. 10.3109/00016489.2010.506653CrossRefPubMed
23.
go back to reference Güldner C, Ningo A, Voigt J, Diogo I, Heinrichs J, Weber R, Wilhelm T, Fiebich M: Potential of dosage reduction in cone-beam-computed tomography (CBCT) for radiological diagnostics of the paranasal sinuses. Eur Arch Otorhinolaryngol 2012, 270(4):1307–1315.CrossRefPubMed Güldner C, Ningo A, Voigt J, Diogo I, Heinrichs J, Weber R, Wilhelm T, Fiebich M: Potential of dosage reduction in cone-beam-computed tomography (CBCT) for radiological diagnostics of the paranasal sinuses. Eur Arch Otorhinolaryngol 2012, 270(4):1307–1315.CrossRefPubMed
24.
go back to reference Güldner C, Pistorius SM, Diogo I, Bien S, Sesterhenn A, Werner JA: Analysis of pneumatization and neurovascular structures of the sphenoid sinus using cone-beam tomography (CBT). Acta Radiol 2012, 53: 214–219. 10.1258/ar.2011.110381CrossRefPubMed Güldner C, Pistorius SM, Diogo I, Bien S, Sesterhenn A, Werner JA: Analysis of pneumatization and neurovascular structures of the sphenoid sinus using cone-beam tomography (CBT). Acta Radiol 2012, 53: 214–219. 10.1258/ar.2011.110381CrossRefPubMed
25.
go back to reference Bremke M, Sesterhenn AM, Murthum T, Al Hail A, Bien S, Werner JA: Digital volume tomography (DVT) as a diagnostic modality of the anterior skull base. Acta Otolaryngol 2009, 129: 1106–1114. 10.1080/00016480802620621CrossRefPubMed Bremke M, Sesterhenn AM, Murthum T, Al Hail A, Bien S, Werner JA: Digital volume tomography (DVT) as a diagnostic modality of the anterior skull base. Acta Otolaryngol 2009, 129: 1106–1114. 10.1080/00016480802620621CrossRefPubMed
26.
go back to reference Bremke M, Wiegand S, Sesterhenn AM, Eken M, Bien S, Werner JA: Digital volume tomography in the diagnosis of nasal bone fractures. Rhinology 2009, 47: 126–131.PubMed Bremke M, Wiegand S, Sesterhenn AM, Eken M, Bien S, Werner JA: Digital volume tomography in the diagnosis of nasal bone fractures. Rhinology 2009, 47: 126–131.PubMed
27.
go back to reference Majdani O, Thews K, Bartling S, Leinung M, Dalchow C, Labadie R, Lenarz T, Heidrich G: Temporal bone imaging: comparison of flat panel volume CT and multisection CT. AJNR Am J Neuroradiol 2009, 30: 1419–1424. 10.3174/ajnr.A1560CrossRefPubMed Majdani O, Thews K, Bartling S, Leinung M, Dalchow C, Labadie R, Lenarz T, Heidrich G: Temporal bone imaging: comparison of flat panel volume CT and multisection CT. AJNR Am J Neuroradiol 2009, 30: 1419–1424. 10.3174/ajnr.A1560CrossRefPubMed
Metadata
Title
Visualisation of the Bonebridge by means of CT and CBCT
Authors
Christian Güldner
Julia Heinrichs
Rainer Weiß
Annette Paula Zimmermann
Benjamin Dassinger
Siegfried Bien
Jochen Alfred Werner
Isabell Diogo
Publication date
01-12-2013
Publisher
BioMed Central
Published in
European Journal of Medical Research / Issue 1/2013
Electronic ISSN: 2047-783X
DOI
https://doi.org/10.1186/2047-783X-18-30

Other articles of this Issue 1/2013

European Journal of Medical Research 1/2013 Go to the issue