Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 1/2014

01-01-2014 | Original Paper

Coronary artery angiography and myocardial viability imaging: a 3.0-T contrast-enhanced magnetic resonance coronary artery angiography with Gd-BOPTA

Authors: Hong Yun, Hang Jin, Shan Yang, Dong Huang, Zhang-wei Chen, Meng-su Zeng

Published in: The International Journal of Cardiovascular Imaging | Issue 1/2014

Login to get access

Abstract

With improving MR sequence, phase-array coil and image quality, cardiac magnetic resonance imaging is becoming a promising method for a comprehensive non-invasive evaluation of coronary artery and myocardial viability. The study aimed to evaluate contrast-enhanced whole-heart coronary MR angiography (CE WH-CMRA) at 3.0-Tesla for the diagnosis of significant stenosis (≥50 %) and detection of myocardial infarction (MI) in patients with suspected coronary artery disease (CAD). CE WH-CMRA was performed in consecutive 70 patients with suspected CAD by using a 3.0-T MR system. A respiratory-gated, electrocardiography-triggered, inversion-recovery, segmented fast low angle shot sequence (TI = 200 ms) was used. Data acquisition began 60 s after the slow injection of Gd-BOPTA (0.2 mmol/kg body weight, at an injection rate 0.3 ml/s). At last, breath-hold 2D-PSIR-SSFP sequence was performed. Diagnostic accuracy of CE WH-CMRA in detecting significant stenosis (≥50 %) was evaluated using invasive coronary angiography as the referenced standard. The MI region appearing as high signal intensity visualized on CEWH-CMRA and 2D-PSIR-SSFP images were compared and analyzed. CE WH-CMRA correctly identified 42 of 44 patients with significant CAD. The overall sensitivity, specificity, negative predictive value, positive predictive value and accuracy for diagnosing significant CAD was 83.6, 95.8, 96.0, 82.8 and 93.4 % respectively. The MI region detected by WH-CMRA and 2D-PSIR-SSFP were consistent in 10 patients and these segments manifested with transmural or subendocardial enhancement patterns. Only one MI patient was judged inconsistent between WH-CMRA and 2D-PSIR-SSFP, who was confirmed by clinical and electrocardiogram results. The enhancement pattern in this patient was spotted and focal in 2D-PSIR-SSFP, but was dismissed by WH-CMRA. It is feasible to obtain information about coronary artery stenosis and myocardial viability in a single CE WH-CMRA with administration of Gd-BOPTA.
Literature
1.
go back to reference Arrighi JA, Dilsizian V (2012) Multimodality imaging for assessment of myocardial viability: nuclear, echocardiography, MR, and CT. Curr Cardiol Rep 14:234–243PubMedCrossRef Arrighi JA, Dilsizian V (2012) Multimodality imaging for assessment of myocardial viability: nuclear, echocardiography, MR, and CT. Curr Cardiol Rep 14:234–243PubMedCrossRef
2.
go back to reference Bhat H, Yang Q, Zuehlsdorff S, Li K, Li D (2010) Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging. Invest Radiol 45:458–464PubMedCentralPubMedCrossRef Bhat H, Yang Q, Zuehlsdorff S, Li K, Li D (2010) Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging. Invest Radiol 45:458–464PubMedCentralPubMedCrossRef
3.
go back to reference Huber ME, Kozerke S, Pruessmann KP, Smink J, Boesiger P (2004) Sensitivity-encoded coronary MRA at 3T. Magn Reson Med 52:221–227PubMedCrossRef Huber ME, Kozerke S, Pruessmann KP, Smink J, Boesiger P (2004) Sensitivity-encoded coronary MRA at 3T. Magn Reson Med 52:221–227PubMedCrossRef
4.
go back to reference Schmitt M, Potthast A, Sosnovik DE, Polimeni JR, Wiggins GC, Triantafyllou C, Wald LL (2008) A 128-channel receive only cardiac coil for highly accelerated cardiac MRI at 3 tesla. Magn Reson Med 59:1431–1439PubMedCentralPubMedCrossRef Schmitt M, Potthast A, Sosnovik DE, Polimeni JR, Wiggins GC, Triantafyllou C, Wald LL (2008) A 128-channel receive only cardiac coil for highly accelerated cardiac MRI at 3 tesla. Magn Reson Med 59:1431–1439PubMedCentralPubMedCrossRef
5.
go back to reference Yang Q, Li K, Bi X, An J, Renate J, Li D (2009) 3T contrast-enhanced whole heart coronary MRA using 32-channel cardiac coils for the detection of coronary artery disease. J Cardiovasc Magn Reson 11(Suppl 1):5CrossRef Yang Q, Li K, Bi X, An J, Renate J, Li D (2009) 3T contrast-enhanced whole heart coronary MRA using 32-channel cardiac coils for the detection of coronary artery disease. J Cardiovasc Magn Reson 11(Suppl 1):5CrossRef
6.
go back to reference Knopp MV, Runge VM, Essig M, Hartman M, Jansen O, Kirchin MA, Moeller A, Seeberg AH, Lodemann KP (2004) Primary and secondary brain tumors at MR imaging: bicentric intraindividual crossover comparison of gadobenate dimeglumine and gadopentetate dimeglumine. Radiology 230:55–64PubMedCrossRef Knopp MV, Runge VM, Essig M, Hartman M, Jansen O, Kirchin MA, Moeller A, Seeberg AH, Lodemann KP (2004) Primary and secondary brain tumors at MR imaging: bicentric intraindividual crossover comparison of gadobenate dimeglumine and gadopentetate dimeglumine. Radiology 230:55–64PubMedCrossRef
7.
go back to reference Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40:715–724PubMedCrossRef Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40:715–724PubMedCrossRef
8.
go back to reference Yang Q, Li K, Liu X et al (2009) Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0-T: a comparative study with X-ray angiography in a single center. J Am Coll Cardiol 54:69–76PubMedCentralPubMedCrossRef Yang Q, Li K, Liu X et al (2009) Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0-T: a comparative study with X-ray angiography in a single center. J Am Coll Cardiol 54:69–76PubMedCentralPubMedCrossRef
9.
go back to reference Wang Yi, Vidan Erez, Bergman Geoffrey W (1999) Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 213:751–758PubMedCrossRef Wang Yi, Vidan Erez, Bergman Geoffrey W (1999) Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiography. Radiology 213:751–758PubMedCrossRef
10.
go back to reference Johnson KR, Patel SJ, Whigham A, Hakim A, Pettigrew RI, Oshinski JN (2004) Three-dimensional, time-resolved motion of the coronary arteries. J Cardiovasc Magn Reson 6:663–673PubMedCrossRef Johnson KR, Patel SJ, Whigham A, Hakim A, Pettigrew RI, Oshinski JN (2004) Three-dimensional, time-resolved motion of the coronary arteries. J Cardiovasc Magn Reson 6:663–673PubMedCrossRef
11.
go back to reference Liu X, Bi X, Huang J, Jerecic R, Carr J, Li D (2008) Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0 T: comparison with steady-state free precession technique at 1.5 T. Invest Radiol 43:663–668PubMedCrossRef Liu X, Bi X, Huang J, Jerecic R, Carr J, Li D (2008) Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0 T: comparison with steady-state free precession technique at 1.5 T. Invest Radiol 43:663–668PubMedCrossRef
12.
go back to reference Bi X, Carr JC, Li D (2007) Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent. Magn Reson Med 58:1–7PubMedCrossRef Bi X, Carr JC, Li D (2007) Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent. Magn Reson Med 58:1–7PubMedCrossRef
13.
go back to reference Bi X, Deshpande V, Simonetti O et al (2005) Three-dimensional breathhold SSFP coronary MRA: a comparison between 1.5 T and 3.0 T. J Magn Reson Imaging 22:206–212PubMedCrossRef Bi X, Deshpande V, Simonetti O et al (2005) Three-dimensional breathhold SSFP coronary MRA: a comparison between 1.5 T and 3.0 T. J Magn Reson Imaging 22:206–212PubMedCrossRef
14.
go back to reference Sommer T, Hackenbroch M, Hofer U et al (2005) Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease. Radiology 234:718–725PubMedCrossRef Sommer T, Hackenbroch M, Hofer U et al (2005) Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease. Radiology 234:718–725PubMedCrossRef
15.
go back to reference Prompona M, Cyran C, Nikolaou K, Bauner K, Reiser M, Huber A (2009) Contrast-enhanced whole-heart MR coronary angiography at 3.0 T using the intravascular contrast agent gadofosveset. Invest Radiol 44:369–374PubMedCrossRef Prompona M, Cyran C, Nikolaou K, Bauner K, Reiser M, Huber A (2009) Contrast-enhanced whole-heart MR coronary angiography at 3.0 T using the intravascular contrast agent gadofosveset. Invest Radiol 44:369–374PubMedCrossRef
16.
go back to reference Thornhill RE, Prato FS, Wisenberg G, Moran GR, Sykes J (2004) Determining the extent to which delayed-enhancement images reflect the partition-coefficient of Gd-DTPA in canine studies of reperfused and unreperfused myocardial infarction. Magn Reson Med 52:1069–1079PubMedCrossRef Thornhill RE, Prato FS, Wisenberg G, Moran GR, Sykes J (2004) Determining the extent to which delayed-enhancement images reflect the partition-coefficient of Gd-DTPA in canine studies of reperfused and unreperfused myocardial infarction. Magn Reson Med 52:1069–1079PubMedCrossRef
17.
go back to reference Hu P, Chan J, Ngo LH, Smink J, Goddu B, Kissinger KV, Goepfert L, Hauser TH, Rofsky NM, Manning WJ, Nezafat R (2011) Contrast-enhanced whole-heart coronary MRI with bolus infusion of gadobenate dimeglumine at 1.5 T. Magn Reson Med 65:392–398PubMedCrossRef Hu P, Chan J, Ngo LH, Smink J, Goddu B, Kissinger KV, Goepfert L, Hauser TH, Rofsky NM, Manning WJ, Nezafat R (2011) Contrast-enhanced whole-heart coronary MRI with bolus infusion of gadobenate dimeglumine at 1.5 T. Magn Reson Med 65:392–398PubMedCrossRef
Metadata
Title
Coronary artery angiography and myocardial viability imaging: a 3.0-T contrast-enhanced magnetic resonance coronary artery angiography with Gd-BOPTA
Authors
Hong Yun
Hang Jin
Shan Yang
Dong Huang
Zhang-wei Chen
Meng-su Zeng
Publication date
01-01-2014
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 1/2014
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-013-0297-4

Other articles of this Issue 1/2014

The International Journal of Cardiovascular Imaging 1/2014 Go to the issue