Abstract

To evaluate the diagnostic accuracy of aortic valve area (AVA) assessment with 320-detector Computed Tomography (MDCT) compared to transthoracic echocardiography (TTE) in a population with mild to severe aortic valve stenosis. AVA was estimated in 169 patients by planimetry on MDCT images (AVAMDCT) and by the continuity equation with TTE (AVATTE). To generate a reference AVA (AVAREF) we used the stroke volume from MDCT divided by the velocity time integral from CW Doppler by TTE (according to the continuity equation: stroke volume in LVOT = stroke volume passing the aortic valve). AVAREF was used as the reference to compare both measures against, since it bypasses the assumption of LVOT being circular in the continuity equation and the potential placement error of PW Doppler in the LVOT. The mean (±SD) age of the patients was 71 (±9) years, 113 (67 %) were males. Mean AVATTE was 0.93 (±0.33) cm2, mean AVAMDCT was 0.99 (±0.36) cm2 and mean AVAREF was 1.00 (±0.39) cm2. The mean difference between AVATTE and AVAMDCT was −0.06 cm2, p = 0.001, mean difference between AVATTE and AVAREF was −0.06 cm2, p < 0.001, and mean difference between AVAMDCT and AVAREF was −0.01 cm2, p = 0.60. Calcification of the aortic valve quantified by Agatston score, significantly decreased the correlation between AVAMDCT and AVAREF, (r low Agatston = 0.90, r high Agatston = 0.57). MDCT measured AVA is slightly larger than AVA measured by TTE (0.06 cm2). The accuracy and precision errors on AVA measurements are comparable for MDCT and TTE. Valvular calcification may primarily affect the accuracy of AVAMDCT.
Literature
1.
go back to reference Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Baron-Esquivias G, Baumgartner H et al (2012) Guidelines on the management of valvular heart disease (version 2012): The Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur J Cardiothorac Surg 33:2451–2496 Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Baron-Esquivias G, Baumgartner H et al (2012) Guidelines on the management of valvular heart disease (version 2012): The Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur J Cardiothorac Surg  33:2451–2496
2.
go back to reference Leipsic J, Gurvitch R, Labounty TM, Min JK, Wood D, Johnson M et al (2011) Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging 4(4):416–429PubMedCrossRef Leipsic J, Gurvitch R, Labounty TM, Min JK, Wood D, Johnson M et al (2011) Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging 4(4):416–429PubMedCrossRef
3.
go back to reference Feuchtner GM, Dichtl W, Friedrich GJ, Frick M, Alber H, Schachner T et al (2006) Multislice computed tomography for detection of patients with aortic valve stenosis and quantification of severity. J Am Coll Cardiol 47(7):1410–1417PubMedCrossRef Feuchtner GM, Dichtl W, Friedrich GJ, Frick M, Alber H, Schachner T et al (2006) Multislice computed tomography for detection of patients with aortic valve stenosis and quantification of severity. J Am Coll Cardiol 47(7):1410–1417PubMedCrossRef
4.
go back to reference Alkadhi H, Wildermuth S, Plass A, Bettex D, Baumert B, Leschka S et al (2006) Aortic stenosis: comparative evaluation of 16-detector row CT and echocardiography. Radiology 240(1):47–55PubMedCrossRef Alkadhi H, Wildermuth S, Plass A, Bettex D, Baumert B, Leschka S et al (2006) Aortic stenosis: comparative evaluation of 16-detector row CT and echocardiography. Radiology 240(1):47–55PubMedCrossRef
5.
go back to reference Pouleur AC, le Polain de Waroux JB, Pasquet A, Vanoverschelde JL, Gerber BL (2007) Aortic valve area assessment: multidetector CT compared with cine MR imaging and transthoracic and transesophageal echocardiography. Radiology 244(3):745–754PubMedCrossRef Pouleur AC, le Polain de Waroux JB, Pasquet A, Vanoverschelde JL, Gerber BL (2007) Aortic valve area assessment: multidetector CT compared with cine MR imaging and transthoracic and transesophageal echocardiography. Radiology 244(3):745–754PubMedCrossRef
6.
go back to reference Laissy JP, Messika-Zeitoun D, Serfaty JM, Sebban V, Schouman-Claeys E, Iung B et al (2007) Comprehensive evaluation of preoperative patients with aortic valve stenosis: usefulness of cardiac multidetector computed tomography. Heart 93(9):1121–1125PubMedCrossRef Laissy JP, Messika-Zeitoun D, Serfaty JM, Sebban V, Schouman-Claeys E, Iung B et al (2007) Comprehensive evaluation of preoperative patients with aortic valve stenosis: usefulness of cardiac multidetector computed tomography. Heart 93(9):1121–1125PubMedCrossRef
7.
go back to reference Feuchtner GM, Muller S, Bonatti J, Schachner T, Velik-Salchner C, Pachinger O et al (2007) Sixty-four slice CT evaluation of aortic stenosis using planimetry of the aortic valve area. AJR Am J Roentgenol 189(1):197–203PubMedCrossRef Feuchtner GM, Muller S, Bonatti J, Schachner T, Velik-Salchner C, Pachinger O et al (2007) Sixty-four slice CT evaluation of aortic stenosis using planimetry of the aortic valve area. AJR Am J Roentgenol 189(1):197–203PubMedCrossRef
8.
go back to reference Tanaka H, Shimada K, Yoshida K, Jissho S, Yoshikawa J, Yoshiyama M (2007) The simultaneous assessment of aortic valve area and coronary artery stenosis using 16-slice multidetector-row computed tomography in patients with aortic stenosis comparison with echocardiography. Circ J 71(10):1593–1598PubMedCrossRef Tanaka H, Shimada K, Yoshida K, Jissho S, Yoshikawa J, Yoshiyama M (2007) The simultaneous assessment of aortic valve area and coronary artery stenosis using 16-slice multidetector-row computed tomography in patients with aortic stenosis comparison with echocardiography. Circ J 71(10):1593–1598PubMedCrossRef
9.
go back to reference Lembcke A, Thiele H, Lachnitt A, Enzweiler CN, Wagner M, Hein PA et al (2008) Precision of forty slice spiral computed tomography for quantifying aortic valve stenosis: comparison with echocardiography and validation against cardiac catheterization. Invest Radiol 43(10):719–728PubMedCrossRef Lembcke A, Thiele H, Lachnitt A, Enzweiler CN, Wagner M, Hein PA et al (2008) Precision of forty slice spiral computed tomography for quantifying aortic valve stenosis: comparison with echocardiography and validation against cardiac catheterization. Invest Radiol 43(10):719–728PubMedCrossRef
10.
go back to reference LaBounty TM, Sundaram B, Agarwal P, Armstrong WA, Kazerooni EA, Yamada E (2008) Aortic valve area on 64-MDCT correlates with transesophageal echocardiography in aortic stenosis. AJR Am J Roentgenol 191(6):1652–1658PubMedCrossRef LaBounty TM, Sundaram B, Agarwal P, Armstrong WA, Kazerooni EA, Yamada E (2008) Aortic valve area on 64-MDCT correlates with transesophageal echocardiography in aortic stenosis. AJR Am J Roentgenol 191(6):1652–1658PubMedCrossRef
11.
go back to reference Lembcke A, Kivelitz DE, Borges AC, Lachnitt A, Hein PA, Dohmen PM et al (2009) Quantification of aortic valve stenosis: head-to-head comparison of 64-slice spiral computed tomography with transesophageal and transthoracic echocardiography and cardiac catheterization. Invest Radiol 44(1):7–14PubMedCrossRef Lembcke A, Kivelitz DE, Borges AC, Lachnitt A, Hein PA, Dohmen PM et al (2009) Quantification of aortic valve stenosis: head-to-head comparison of 64-slice spiral computed tomography with transesophageal and transthoracic echocardiography and cardiac catheterization. Invest Radiol 44(1):7–14PubMedCrossRef
12.
go back to reference Halpern EJ, Mallya R, Sewell M, Shulman M, Zwas DR (2009) Differences in aortic valve area measured with CT planimetry and echocardiography (continuity equation) are related to divergent estimates of left ventricular outflow tract area. AJR Am J Roentgenol 192(6):1668–1673PubMedCrossRef Halpern EJ, Mallya R, Sewell M, Shulman M, Zwas DR (2009) Differences in aortic valve area measured with CT planimetry and echocardiography (continuity equation) are related to divergent estimates of left ventricular outflow tract area. AJR Am J Roentgenol 192(6):1668–1673PubMedCrossRef
13.
go back to reference Westermann Y, Geigenmuller A, Elgeti T, Wagner M, Dushe S, Borges AC et al (2011) Planimetry of the aortic valve orifice area: comparison of multislice spiral computed tomography and magnetic resonance imaging. Eur J Radiol 77(3):426–435PubMedCrossRef Westermann Y, Geigenmuller A, Elgeti T, Wagner M, Dushe S, Borges AC et al (2011) Planimetry of the aortic valve orifice area: comparison of multislice spiral computed tomography and magnetic resonance imaging. Eur J Radiol 77(3):426–435PubMedCrossRef
14.
go back to reference Mizia-Stec K, Pysz P, Jasinski M, Adamczyk T, Drzewiecka-Gerber A, Chmiel A et al (2012) Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis. Int J Cardiovasc Imaging 28(2):343–352PubMedCentralPubMedCrossRef Mizia-Stec K, Pysz P, Jasinski M, Adamczyk T, Drzewiecka-Gerber A, Chmiel A et al (2012) Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis. Int J Cardiovasc Imaging 28(2):343–352PubMedCentralPubMedCrossRef
15.
go back to reference Bouvier E, Logeart D, Sablayrolles JL, Feignoux J, Scheuble C, Touche T et al (2006) Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography. Eur Heart J 27(24):3033–3038PubMedCrossRef Bouvier E, Logeart D, Sablayrolles JL, Feignoux J, Scheuble C, Touche T et al (2006) Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography. Eur Heart J 27(24):3033–3038PubMedCrossRef
16.
go back to reference Lembcke A, Woinke M, Borges AC, Dohmen PM, Lachnitt A, Westermann Y et al (2009) Grading of aortic valve stenosis at 64-slice spiral computed tomography: comparison with transthoracic echocardiography and calibration against cardiac catheterization. Invest Radiol 44(6):360–368PubMedCrossRef Lembcke A, Woinke M, Borges AC, Dohmen PM, Lachnitt A, Westermann Y et al (2009) Grading of aortic valve stenosis at 64-slice spiral computed tomography: comparison with transthoracic echocardiography and calibration against cardiac catheterization. Invest Radiol 44(6):360–368PubMedCrossRef
17.
go back to reference Utsunomiya H, Yamamoto H, Horiguchi J, Kunita E, Okada T, Yamazato R et al (2012) Underestimation of aortic valve area in calcified aortic valve disease: effects of left ventricular outflow tract ellipticity. Int J Cardiol 157(3):347–353PubMedCrossRef Utsunomiya H, Yamamoto H, Horiguchi J, Kunita E, Okada T, Yamazato R et al (2012) Underestimation of aortic valve area in calcified aortic valve disease: effects of left ventricular outflow tract ellipticity. Int J Cardiol 157(3):347–353PubMedCrossRef
18.
go back to reference Fuchs A, Kuhl JT, Lonborg J, Engstrom T, Vejlstrup N, Kober L et al (2012) Automated assessment of heart chamber volumes and function in patients with previous myocardial infarction using multidetector computed tomography. J Cardiovasc Comput Tomogr 6(5):325–334PubMedCrossRef Fuchs A, Kuhl JT, Lonborg J, Engstrom T, Vejlstrup N, Kober L et al (2012) Automated assessment of heart chamber volumes and function in patients with previous myocardial infarction using multidetector computed tomography. J Cardiovasc Comput Tomogr 6(5):325–334PubMedCrossRef
19.
go back to reference Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A, Griffin BP et al (2009) Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. J Am Soc Echocardiogr 22(1):1–23PubMedCrossRef Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A, Griffin BP et al (2009) Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. J Am Soc Echocardiogr 22(1):1–23PubMedCrossRef
20.
go back to reference Doddamani S, Grushko MJ, Makaryus AN, Jain VR, Bello R, Friedman MA et al (2009) Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT. Int J Cardiovasc Imaging 25(2):175–181PubMedCrossRef Doddamani S, Grushko MJ, Makaryus AN, Jain VR, Bello R, Friedman MA et al (2009) Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT. Int J Cardiovasc Imaging 25(2):175–181PubMedCrossRef
21.
go back to reference Small GR, Kazmi M, Dekemp RA, Chow BJ (2011) Established and emerging dose reduction methods in cardiac computed tomography. J Nucl Cardiol 18(4):570–579PubMedCrossRef Small GR, Kazmi M, Dekemp RA, Chow BJ (2011) Established and emerging dose reduction methods in cardiac computed tomography. J Nucl Cardiol 18(4):570–579PubMedCrossRef
22.
go back to reference Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY et al (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol 195(3):649–654PubMedCrossRef Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY et al (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol 195(3):649–654PubMedCrossRef
23.
go back to reference Abdulla J, Sivertsen J, Kofoed KF, Alkadhi H, LaBounty T, Abildstrom SZ et al (2009) Evaluation of aortic valve stenosis by cardiac multislice computed tomography compared with echocardiography: a systematic review and meta-analysis. J Heart Valve Dis 18(6):634–643PubMed Abdulla J, Sivertsen J, Kofoed KF, Alkadhi H, LaBounty T, Abildstrom SZ et al (2009) Evaluation of aortic valve stenosis by cardiac multislice computed tomography compared with echocardiography: a systematic review and meta-analysis. J Heart Valve Dis 18(6):634–643PubMed
24.
go back to reference Shah RG, Novaro GM, Blandon RJ, Whiteman MS, Asher CR, Kirsch J (2009) Aortic valve area: meta-analysis of diagnostic performance of multi-detector computed tomography for aortic valve area measurements as compared to transthoracic echocardiography. Int J Cardiovasc Imaging 25(6):601–609PubMedCrossRef Shah RG, Novaro GM, Blandon RJ, Whiteman MS, Asher CR, Kirsch J (2009) Aortic valve area: meta-analysis of diagnostic performance of multi-detector computed tomography for aortic valve area measurements as compared to transthoracic echocardiography. Int J Cardiovasc Imaging 25(6):601–609PubMedCrossRef
25.
go back to reference Messika-Zeitoun D, Aubry MC, Detaint D, Bielak LF, Peyser PA, Sheedy PF et al (2004) Evaluation and clinical implications of aortic valve calcification measured by electron-beam computed tomography. Circulation 110(3):356–362PubMedCrossRef Messika-Zeitoun D, Aubry MC, Detaint D, Bielak LF, Peyser PA, Sheedy PF et al (2004) Evaluation and clinical implications of aortic valve calcification measured by electron-beam computed tomography. Circulation 110(3):356–362PubMedCrossRef
26.
go back to reference Koos R, Mahnken AH, Sinha AM, Wildberger JE, Hoffmann R, Kuhl HP (2004) Aortic valve calcification as a marker for aortic stenosis severity: assessment on 16-MDCT. AJR Am J Roentgenol 183(6):1813–1818PubMedCrossRef Koos R, Mahnken AH, Sinha AM, Wildberger JE, Hoffmann R, Kuhl HP (2004) Aortic valve calcification as a marker for aortic stenosis severity: assessment on 16-MDCT. AJR Am J Roentgenol 183(6):1813–1818PubMedCrossRef
27.
go back to reference Cowell SJ, Newby DE, Burton J, White A, Northridge DB, Boon NA et al (2003) Aortic valve calcification on computed tomography predicts the severity of aortic stenosis. Clin Radiol 58(9):712–716PubMedCrossRef Cowell SJ, Newby DE, Burton J, White A, Northridge DB, Boon NA et al (2003) Aortic valve calcification on computed tomography predicts the severity of aortic stenosis. Clin Radiol 58(9):712–716PubMedCrossRef
28.
go back to reference Baumgartner H (2006) Hemodynamic assessment of aortic stenosis: are there still lessons to learn? J Am Coll Cardiol 47(1):138–140PubMedCrossRef Baumgartner H (2006) Hemodynamic assessment of aortic stenosis: are there still lessons to learn? J Am Coll Cardiol 47(1):138–140PubMedCrossRef
Metadata
Title
Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography
Authors
Linnea Hornbech Larsen
Klaus Fuglsang Kofoed
Helle Gervig Carstensen
Mads Rams Mejdahl
Mads Jønsson Andersen
Jesper Kjaergaard
Olav Wendelboe Nielsen
Lars Køber
Rasmus Møgelvang
Christian Hassager
Publication date
01-01-2014
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 1/2014
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-013-0295-6

Other articles of this Issue 1/2014

The International Journal of Cardiovascular Imaging 1/2014 Go to the issue

Images in Cardiology

Massive left atrium thrombus