27-10-2022 | Computed Tomography | Original Article

Computed tomography vs. cinefluoroscopy for the assessment of mechanical prosthetic valve leaflet motion

Authors: Mohammad Abdelghani, Mohamed Abdelfattah, Ahmed Mohamed Diab, Hamada Elsheikh, Mohy E. Mansour Elabbady

Published in: Heart and Vessels | Issue 4/2023

Login to get access

Abstract

Evaluation of mechanical prosthetic valve function is based on echocardiography, but adequate assessment of leaflet motion is limited by acoustic shadowing. Cinefluoroscopy is a standard method to assess leaflet motion, while computed tomography (CT) has been suggested as an alternative. We sought to compare the feasibility of leaflet motion assessment by cinefluoroscopy vs. CT. In 35 prospectively enrolled patients, leaflet motion was assessed in 43 bileaflet mechanical prostheses (29 mitral and 14 aortic) by cinefluoroscopy and non-contrast CT. Assessment was considered feasible when the ‘in profile’ projection (with the radiographic beam parallel to both the valve ring plane and the tilting axis of discs) could be achieved. Overall feasibility of fluoroscopic assessment was 74% (mitral, 66% vs. aortic, 93%; p = 0.071), while feasibility of CT assessment was 100% (p = 0.003). Among prostheses with unfeasible fluoroscopic assessment, CT suggested an extreme C-arm angulation to achieve the “in profile” projection (RAO: 76.0 ± 5.8°, LAO: 122.7 ± 32.5°, CRA: 51.4 ± 16.0°, CAU: 57.0 ± 18.2°). Among prostheses with feasible assessment by both techniques, fluoroscopy and CT yielded similar opening and closing angles (intraclass correlation coefficient, 0.959–0.998) with lower irradiation with CT as compared with fluoroscopy (26.2[21.1–29.3] vs. 289[179–358] mGy, p < 0.001). While CT scan took 8.7 ± 0.5 s, fluoroscopy required 2.64 ± 1.56 min to achieve and record the “in profile” projection. Non-contrast CT provides a higher feasibility and a quicker evaluation of mechanical prosthetic valve leaflet motion with less irradiation than fluoroscopy, especially in mitral valve position.
Literature
1.
go back to reference Lancellotti P, Pibarot P, Chambers J, Edvardsen T, Delgado V, Dulgheru R, Pepi M, Cosyns B, Dweck MR, Garbi M, Magne J, Nieman K, Rosenhek R, Bernard A, Lowenstein J, Vieira ML, Rabischoffsky A, Vyhmeister RH, Zhou X, Zhang Y, Zamorano JL, Habib G (2016) Recommendations for the imaging assessment of prosthetic heart valves: a report from the European association of cardiovascular imaging endorsed by the Chinese society of echocardiography, the inter-American society of echocardiography, and the Brazilian department of cardiovascular imaging. Eur Heart J Cardiovasc Imaging 17(6):589–590CrossRefPubMed Lancellotti P, Pibarot P, Chambers J, Edvardsen T, Delgado V, Dulgheru R, Pepi M, Cosyns B, Dweck MR, Garbi M, Magne J, Nieman K, Rosenhek R, Bernard A, Lowenstein J, Vieira ML, Rabischoffsky A, Vyhmeister RH, Zhou X, Zhang Y, Zamorano JL, Habib G (2016) Recommendations for the imaging assessment of prosthetic heart valves: a report from the European association of cardiovascular imaging endorsed by the Chinese society of echocardiography, the inter-American society of echocardiography, and the Brazilian department of cardiovascular imaging. Eur Heart J Cardiovasc Imaging 17(6):589–590CrossRefPubMed
2.
go back to reference Muratori M, Montorsi P, Teruzzi G, Celeste F, Doria E, Alamanni F, Pepi M (2006) Feasibility and diagnostic accuracy of quantitative assessment of mechanical prostheses leaflet motion by transthoracic and transesophageal echocardiography in suspected prosthetic valve dysfunction. Am J Cardiol 97(1):94–100CrossRefPubMed Muratori M, Montorsi P, Teruzzi G, Celeste F, Doria E, Alamanni F, Pepi M (2006) Feasibility and diagnostic accuracy of quantitative assessment of mechanical prostheses leaflet motion by transthoracic and transesophageal echocardiography in suspected prosthetic valve dysfunction. Am J Cardiol 97(1):94–100CrossRefPubMed
3.
go back to reference Muratori M, Montorsi P, Maffessanti F, Teruzzi G, Zoghbi WA, Gripari P, Tamborini G, Ghulam Ali S, Fusini L, Fiorentini C, Pepi M (2013) Dysfunction of bileaflet aortic prosthesis: accuracy of echocardiography versus fluoroscopy. JACC Cardiovasc Imaging 6(2):196–205CrossRefPubMed Muratori M, Montorsi P, Maffessanti F, Teruzzi G, Zoghbi WA, Gripari P, Tamborini G, Ghulam Ali S, Fusini L, Fiorentini C, Pepi M (2013) Dysfunction of bileaflet aortic prosthesis: accuracy of echocardiography versus fluoroscopy. JACC Cardiovasc Imaging 6(2):196–205CrossRefPubMed
4.
go back to reference Montorsi P, Arena V, Muratori M, Lavarra F, Cavoretto D, Repossini A, Guazzi MD (1996) Fluoroscopic functional evaluation of bileaflet prostheses: effect of different intraoperative valve orientation. Am J Card Imaging 10(2):101–107PubMed Montorsi P, Arena V, Muratori M, Lavarra F, Cavoretto D, Repossini A, Guazzi MD (1996) Fluoroscopic functional evaluation of bileaflet prostheses: effect of different intraoperative valve orientation. Am J Card Imaging 10(2):101–107PubMed
5.
go back to reference Habets J, Symersky P, van Herwerden LA, de Mol BA, Spijkerboer AM, Mali WP, Budde RP (2011) Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients. Eur Radiol 21(7):1390–1396CrossRefPubMedPubMedCentral Habets J, Symersky P, van Herwerden LA, de Mol BA, Spijkerboer AM, Mali WP, Budde RP (2011) Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients. Eur Radiol 21(7):1390–1396CrossRefPubMedPubMedCentral
6.
go back to reference Suchá D, Symersky P, Vonken EJ, Provoost E, Chamuleau SA, Budde RP (2014) Multidetector-row computed tomography allows accurate measurement of mechanical prosthetic heart valve leaflet closing angles compared with fluoroscopy. J Comput Assist Tomogr 38(3):451–456CrossRefPubMed Suchá D, Symersky P, Vonken EJ, Provoost E, Chamuleau SA, Budde RP (2014) Multidetector-row computed tomography allows accurate measurement of mechanical prosthetic heart valve leaflet closing angles compared with fluoroscopy. J Comput Assist Tomogr 38(3):451–456CrossRefPubMed
7.
go back to reference Symersky P, Budde RP, de Mol BA, Prokop M (2009) Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction. Am J Cardiol 104(8):1128–1134CrossRefPubMed Symersky P, Budde RP, de Mol BA, Prokop M (2009) Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction. Am J Cardiol 104(8):1128–1134CrossRefPubMed
8.
go back to reference Cianciulli TE, Lax JA, Beck MA, Cerruti FE, Gigena GE, Saccheri MC, Fernández E, Dorelle AN, Leguizamón JH, Prezioso HA (2005) Cinefluoroscopic assessment of mechanical disc prostheses: its value as a complementary method to echocardiography. J Heart Valve Dis 14(5):664–673PubMed Cianciulli TE, Lax JA, Beck MA, Cerruti FE, Gigena GE, Saccheri MC, Fernández E, Dorelle AN, Leguizamón JH, Prezioso HA (2005) Cinefluoroscopic assessment of mechanical disc prostheses: its value as a complementary method to echocardiography. J Heart Valve Dis 14(5):664–673PubMed
Metadata
Title
Computed tomography vs. cinefluoroscopy for the assessment of mechanical prosthetic valve leaflet motion
Authors
Mohammad Abdelghani
Mohamed Abdelfattah
Ahmed Mohamed Diab
Hamada Elsheikh
Mohy E. Mansour Elabbady
Publication date
27-10-2022
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 4/2023
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-022-02193-x

Other articles of this Issue 4/2023

Heart and Vessels 4/2023 Go to the issue