Skip to main content
Top
Published in: Japanese Journal of Radiology 2/2024

Open Access 27-08-2023 | Computed Tomography | Pictorial Essay

Evaluation of the ear ossicles with photon-counting detector CT

Authors: Yuka Takahashi, Fumiyo Higaki, Akiko Sugaya, Yudai Asano, Katsuhide Kojima, Yusuke Morimitsu, Noriaki Akagi, Toshihide Itoh, Yusuke Matsui, Takao Hiraki

Published in: Japanese Journal of Radiology | Issue 2/2024

Login to get access

Abstract

Recently, computed tomography with photon-counting detector (PCD-CT) has been developed to enable high-resolution imaging at a lower radiation dose. PCD-CT employs a photon-counting detector that can measure the number of incident X-ray photons and their energy. The newly released PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Forchheim, Germany) has been in clinical use at our institution since December 2022. The PCD-CT offers several advantages over current state-of-the-art energy-integrating detector CT (EID-CT). The PCD-CT does not require septa to create a detector channel, while EID-CT does. Therefore, downsizing the anode to achieve higher resolution does not affect the dose efficiency of the PCD-CT. CT is an indispensable modality for evaluating ear ossicles. The ear ossicles and joints are clearly depicted by PCD-CT. In particular, the anterior and posterior legs of the stapes, which are sometimes unclear on conventional CT scans, can be clearly visualized. We present cases of congenital anomalies of the ossicular chain, ossicular chain dislocation, tympanosclerosis, and cholesteatoma in which PCD-CT was useful. This short article reports the usefulness of PCD-CT in the 3D visualization of the ear ossicles.
Literature
1.
go back to reference Benson JC, Rajendran K, Lane JI, Diehn FE, Weber NM, Thorne JE, et al. A new frontier in temporal bone imaging: photon-counting detector CT demonstrates superior visualization of critical anatomic structures at reduced radiation dose. AJNR Am J Neuroradiol. 2022;43:579–84.CrossRefPubMedPubMedCentral Benson JC, Rajendran K, Lane JI, Diehn FE, Weber NM, Thorne JE, et al. A new frontier in temporal bone imaging: photon-counting detector CT demonstrates superior visualization of critical anatomic structures at reduced radiation dose. AJNR Am J Neuroradiol. 2022;43:579–84.CrossRefPubMedPubMedCentral
2.
go back to reference Zhou W, Lane JI, Carlson ML, Bruesewitz MR, Witte RJ, Koeller KK, et al. Comparison of a photon-counting-detector CT with an energy-integrating-detector CT for temporal bone imaging: a cadaveric study. AJNR Am J Neuroradiol. 2018;39:1733–8.CrossRefPubMedPubMedCentral Zhou W, Lane JI, Carlson ML, Bruesewitz MR, Witte RJ, Koeller KK, et al. Comparison of a photon-counting-detector CT with an energy-integrating-detector CT for temporal bone imaging: a cadaveric study. AJNR Am J Neuroradiol. 2018;39:1733–8.CrossRefPubMedPubMedCentral
3.
go back to reference Pourmorteza A, Symons R, Henning A, Ulzheimer S, Bluemke DA. Dose efficiency of quarter-millimeter photon-counting computed tomography: first-in-human results. Invest Radiol. 2018;53:365–72.CrossRefPubMed Pourmorteza A, Symons R, Henning A, Ulzheimer S, Bluemke DA. Dose efficiency of quarter-millimeter photon-counting computed tomography: first-in-human results. Invest Radiol. 2018;53:365–72.CrossRefPubMed
4.
go back to reference Yu Z, Leng S, Kappler S, Hahn K, Li Z, Halaweish AF, et al. Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner. J Med Imaging (Bellingham). 2016;3: 043503.CrossRefPubMed Yu Z, Leng S, Kappler S, Hahn K, Li Z, Halaweish AF, et al. Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner. J Med Imaging (Bellingham). 2016;3: 043503.CrossRefPubMed
5.
go back to reference Teunissen EB, Cremers WR. Classification of congenital middle ear anomalies. Report on 144 ears. Ann Otol Rhinol Laryngol. 1993;102:606–12. Teunissen EB, Cremers WR. Classification of congenital middle ear anomalies. Report on 144 ears. Ann Otol Rhinol Laryngol. 1993;102:606–12.
6.
go back to reference Schubiger O, Valavanis A, Stuckmann G, Antonucci F. Temporal bone fractures and their complications. Examination with high resolution CT. Neuroradiology. 1986;28:93–9.CrossRefPubMed Schubiger O, Valavanis A, Stuckmann G, Antonucci F. Temporal bone fractures and their complications. Examination with high resolution CT. Neuroradiology. 1986;28:93–9.CrossRefPubMed
7.
go back to reference Yetiser S, Hidir Y, Birkent H, Satar B, Durmaz A. Traumatic ossicular dislocations: etiology and management. Am J Otolaryngol. 2008;29:31–6.CrossRefPubMed Yetiser S, Hidir Y, Birkent H, Satar B, Durmaz A. Traumatic ossicular dislocations: etiology and management. Am J Otolaryngol. 2008;29:31–6.CrossRefPubMed
8.
go back to reference Meriot P, Veillon F, Garcia JF, Nonent M, Jezequel J, Bourjat P, et al. CT appearances of ossicular injuries. Radiographics. 1997;17:1445–54.CrossRefPubMed Meriot P, Veillon F, Garcia JF, Nonent M, Jezequel J, Bourjat P, et al. CT appearances of ossicular injuries. Radiographics. 1997;17:1445–54.CrossRefPubMed
9.
go back to reference Delrue S, Verhaert N, Dinther JV, Zarowski A, Somers T, Desloovere C, et al. Surgical management and hearing outcome of traumatic ossicular injuries. J Int Adv Otol. 2016;12:231–6.CrossRefPubMed Delrue S, Verhaert N, Dinther JV, Zarowski A, Somers T, Desloovere C, et al. Surgical management and hearing outcome of traumatic ossicular injuries. J Int Adv Otol. 2016;12:231–6.CrossRefPubMed
10.
go back to reference Maillot O, Attyé A, Boyer E, Heck O, Kastler A, Grand S, et al. Post-traumatic deafness: a pictorial review of CT and MRI findings. Insights Imaging. 2016;7:341–50.CrossRefPubMedPubMedCentral Maillot O, Attyé A, Boyer E, Heck O, Kastler A, Grand S, et al. Post-traumatic deafness: a pictorial review of CT and MRI findings. Insights Imaging. 2016;7:341–50.CrossRefPubMedPubMedCentral
11.
go back to reference Ho KY, Tsai SM, Chai CY, Wang HM. Clinical analysis of intratympanic tympanosclerosis: etiology, ossicular chain findings, and hearing results of surgery. Acta Otolaryngol. 2010;130:370–4.CrossRefPubMed Ho KY, Tsai SM, Chai CY, Wang HM. Clinical analysis of intratympanic tympanosclerosis: etiology, ossicular chain findings, and hearing results of surgery. Acta Otolaryngol. 2010;130:370–4.CrossRefPubMed
Metadata
Title
Evaluation of the ear ossicles with photon-counting detector CT
Authors
Yuka Takahashi
Fumiyo Higaki
Akiko Sugaya
Yudai Asano
Katsuhide Kojima
Yusuke Morimitsu
Noriaki Akagi
Toshihide Itoh
Yusuke Matsui
Takao Hiraki
Publication date
27-08-2023
Publisher
Springer Nature Singapore
Published in
Japanese Journal of Radiology / Issue 2/2024
Print ISSN: 1867-1071
Electronic ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-023-01485-0

Other articles of this Issue 2/2024

Japanese Journal of Radiology 2/2024 Go to the issue