Skip to main content
Top
Published in: Radiological Physics and Technology 1/2020

01-03-2020

Development of a computer simulation technique for low-dose chest radiographs: a phantom study

Authors: Rie Murakami, Shigehiko Katsuragawa

Published in: Radiological Physics and Technology | Issue 1/2020

Login to get access

Abstract

The present study aimed to develop a simple computer simulation method of low-dose radiographs based on a radiograph acquired at a clinical-dose level. A chest phantom was used for the development of this method. In this method, a simulated low-dose image was obtained from a clinical-dose image using an input–output characteristic curve of a flat panel detector and noise metrics of the standard deviation (SD) and noise power spectrum. We applied this method for low-dose images of a chest phantom to evaluate the simulation accuracy. The noise SDs were compared between the simulated and real images corresponding to 1/2, 1/4, and 1/8 of clinical doses. The relative error of noise SDs in the chest phantom images was less than 3%. Therefore, we believe that the proposed simulation method has the potential to be useful for determination of the optimal exposure condition in chest radiography to reduce patients’ exposure dose.
Literature
1.
go back to reference International commission on radiological protection: radiological protection and safety in medicine. ICRP Publication 73. Ann. ICRP26. Oxford: Pergamon Press; 1996. p. 1–47. International commission on radiological protection: radiological protection and safety in medicine. ICRP Publication 73. Ann. ICRP26. Oxford: Pergamon Press; 1996. p. 1–47.
2.
go back to reference Moores DM, Regulla D. A review of the scientific basis for radiation protection of the patient. Radiat Prot Dosim. 2011;147:22–9.CrossRef Moores DM, Regulla D. A review of the scientific basis for radiation protection of the patient. Radiat Prot Dosim. 2011;147:22–9.CrossRef
3.
go back to reference Hendee WR, Edward FM. ARALA and an integrated approach to radiation protection. Semin Nucl Med. 1986;16:142–50.CrossRef Hendee WR, Edward FM. ARALA and an integrated approach to radiation protection. Semin Nucl Med. 1986;16:142–50.CrossRef
4.
go back to reference Uffmann M, Schaefer-Prokop C. Digital radiography: the balance between image quality and required radiation dose. Eur J Radiol. 2009;72:202–8.CrossRef Uffmann M, Schaefer-Prokop C. Digital radiography: the balance between image quality and required radiation dose. Eur J Radiol. 2009;72:202–8.CrossRef
5.
go back to reference Willis CE, Slovis TL. The ALARA concept in pediatric CR and DR: dose reduction in pediatric radiographic exams—a white paper conference executive summary. Pediatr Radiol. 2004;34:162–4.CrossRef Willis CE, Slovis TL. The ALARA concept in pediatric CR and DR: dose reduction in pediatric radiographic exams—a white paper conference executive summary. Pediatr Radiol. 2004;34:162–4.CrossRef
6.
go back to reference Sund P, Båth M, Kheddache S, Månsson LG. Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography. Eur Radiol. 2004;14:48–58.CrossRef Sund P, Båth M, Kheddache S, Månsson LG. Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography. Eur Radiol. 2004;14:48–58.CrossRef
7.
go back to reference Saunders RS, Samei E. A method for modifying the image quality parameters of digital radiographic images. Med Phys. 2003;30:3006–177.CrossRef Saunders RS, Samei E. A method for modifying the image quality parameters of digital radiographic images. Med Phys. 2003;30:3006–177.CrossRef
8.
go back to reference Samei E, Flynn MJ, Eyler WR. Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs. Radiology. 1999;213:727–34.CrossRef Samei E, Flynn MJ, Eyler WR. Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs. Radiology. 1999;213:727–34.CrossRef
9.
go back to reference Veldkamp WJH, Kroft LJM, Geleijns J. Dose and perceived image quality in chest radiography. Eur J Radiol. 2009;72:209–17.CrossRef Veldkamp WJH, Kroft LJM, Geleijns J. Dose and perceived image quality in chest radiography. Eur J Radiol. 2009;72:209–17.CrossRef
10.
go back to reference Bochud FO, Valley JF, Verdun FR, Hessler C, Schnyder P. Estimation of the noisy component of anatomical backgrounds. Med Phys. 1999;26:1365–70.CrossRef Bochud FO, Valley JF, Verdun FR, Hessler C, Schnyder P. Estimation of the noisy component of anatomical backgrounds. Med Phys. 1999;26:1365–70.CrossRef
11.
go back to reference Veldkamp WJH, Kroft LJM, Van Delft JPA, Geleijns J. A technique for simulating the effect of dose reduction on image quality in digital chest radiography. J Digit Imaging. 2009;22:114–25.CrossRef Veldkamp WJH, Kroft LJM, Van Delft JPA, Geleijns J. A technique for simulating the effect of dose reduction on image quality in digital chest radiography. J Digit Imaging. 2009;22:114–25.CrossRef
12.
go back to reference Tanaka R, Ichikawa K, Matsubara K, Kawashima H. Review of a simple noise simulation technique in digital radiography. Radiol Phys Technol. 2012;5:178–85.CrossRef Tanaka R, Ichikawa K, Matsubara K, Kawashima H. Review of a simple noise simulation technique in digital radiography. Radiol Phys Technol. 2012;5:178–85.CrossRef
13.
go back to reference Båth M, Håkansson M, Tingberg A, Månsson LG. Method of simulating dose reduction for digital radiographic systems. Radiat Prot Dosim. 2005;114:253–9.CrossRef Båth M, Håkansson M, Tingberg A, Månsson LG. Method of simulating dose reduction for digital radiographic systems. Radiat Prot Dosim. 2005;114:253–9.CrossRef
14.
go back to reference Saito Y, Kawai A, Fujita N, Yamada M, Kodera Y. Reduction of patient dose in digital mammography: simulation of low-dose image from a routine dose. Lect Notes Comput Sci. 2012;7361:611–8.CrossRef Saito Y, Kawai A, Fujita N, Yamada M, Kodera Y. Reduction of patient dose in digital mammography: simulation of low-dose image from a routine dose. Lect Notes Comput Sci. 2012;7361:611–8.CrossRef
15.
go back to reference Saito Y, Sakai M, Fujita N, Kodera Y. Reduction of patient dose in digital mammography: simulation of low-dose image using computed radiography system and flat panel detector system. Proc of SPIE. 2013;8668:86684K.CrossRef Saito Y, Sakai M, Fujita N, Kodera Y. Reduction of patient dose in digital mammography: simulation of low-dose image using computed radiography system and flat panel detector system. Proc of SPIE. 2013;8668:86684K.CrossRef
16.
go back to reference Samei E, Peck DJ. Hendee's physics of medical imaging. Hoboken: Wiley; 2019. p. 105–125. Samei E, Peck DJ. Hendee's physics of medical imaging. Hoboken: Wiley; 2019. p. 105–125.
Metadata
Title
Development of a computer simulation technique for low-dose chest radiographs: a phantom study
Authors
Rie Murakami
Shigehiko Katsuragawa
Publication date
01-03-2020
Publisher
Springer Singapore
Published in
Radiological Physics and Technology / Issue 1/2020
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-020-00555-6

Other articles of this Issue 1/2020

Radiological Physics and Technology 1/2020 Go to the issue