Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2020

Open Access 01-12-2020 | Computed Tomography | Research article

Effect of unilateral pulsed jet lavage prior to vertebroplasty on the intravertebral pressure and cement distribution

Authors: Jun Yan, Qiaohui Liu, Yanping Zheng, Ziqun Liu, Xinyu Liu, Xun Guo, Penghui Liu, Peng Chen, Suomao Yuan, Yonghao Tian, Wanlong Xu

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2020

Login to get access

Abstract

Background

Percutaneous vertebroplasty is the most common treatment for osteoporotic vertebral compression fracture. However, the morbidity of vertebroplasty-related complications, such as cement leakage, remains high. We tested a new technique of unilateral pulsed jet lavage and investigated its effect on the intravertebral pressure and bone cement distribution.

Methods

Thirty lumbar vertebrae (L1-L5) from six cadaver spines were randomly allocated into two groups (with and without irrigation). Prior to vertebroplasty, pulsed jet lavage was performed through one side of the pedicle by using a novel cannula with two concentric conduits to remove the fat and bone marrow of the vertebral bodies in the group with irrigation. The control group was not irrigated. Then, standardized vertebroplasty was performed in the vertebral bodies in both groups. Changes in the intravertebral pressure during injection were recorded. Computed tomography (CT) was performed to observe the cement distribution and extravasations, and the cement mass volume (CMV) was calculated.

Results

During cement injection, the average maximum intravertebral pressure of the unirrigated group was higher than that of the irrigated group (4.92 kPa versus 2.22 kPa, P < 0.05). CT scans showed a more homogeneous cement distribution with less CMV (3832 mm3 vs. 4344 mm3, P < 0.05) and less leakage rate (6.7% vs. 46.7%, P < 0.05) in the irrigated group than in the control group.

Conclusions

Unilateral pulsed jet lavage can reduce intravertebral pressure and lower the incidence of cement leakage during vertebroplasty. An enhanced bone cement distribution can also be achieved through this lavage system.
Literature
1.
go back to reference Gerling MC, Eubanks JD, Patel R, Whang PG, Bohlman HH, Ahn NU. Cement augmentation of refractory osteoporotic vertebral compression fractures. Spine. 2011;36(19):E1266–9.CrossRef Gerling MC, Eubanks JD, Patel R, Whang PG, Bohlman HH, Ahn NU. Cement augmentation of refractory osteoporotic vertebral compression fractures. Spine. 2011;36(19):E1266–9.CrossRef
2.
go back to reference Pneumaticos SG, Triantafyllopoulos GK, Evangelopoulos DS, Hipp JA, Heggeness MH. Effect of vertebroplasty on the compressive strength of vertebral bodies. The Spine Journal. 2013;13(12):1921–7.CrossRef Pneumaticos SG, Triantafyllopoulos GK, Evangelopoulos DS, Hipp JA, Heggeness MH. Effect of vertebroplasty on the compressive strength of vertebral bodies. The Spine Journal. 2013;13(12):1921–7.CrossRef
3.
go back to reference Barr JD, Barr MS, Lemley TJ, McCann RM. Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine (Phila Pa 1976). 2000;25(8):923–8.CrossRef Barr JD, Barr MS, Lemley TJ, McCann RM. Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine (Phila Pa 1976). 2000;25(8):923–8.CrossRef
4.
go back to reference Heini PF. The current treatment—a survey of osteoporotic fracture treatment. Osteoporotic spine fractures: the spine surgeon’s perspective. Osteoporosis International. 2004;16(S02):S85–92.CrossRef Heini PF. The current treatment—a survey of osteoporotic fracture treatment. Osteoporotic spine fractures: the spine surgeon’s perspective. Osteoporosis International. 2004;16(S02):S85–92.CrossRef
5.
go back to reference Klazen CAH, Lohle PNM, de Vries J, Jansen FH, Tielbeek AV, Blonk MC, et al. Vertebroplasty versus conservative treatment in acute osteoporotic vertebral compression fractures (Vertos II): an open-label randomised trial. The Lancet. 2010;376(9746):1085–92.CrossRef Klazen CAH, Lohle PNM, de Vries J, Jansen FH, Tielbeek AV, Blonk MC, et al. Vertebroplasty versus conservative treatment in acute osteoporotic vertebral compression fractures (Vertos II): an open-label randomised trial. The Lancet. 2010;376(9746):1085–92.CrossRef
6.
go back to reference Benneker LM, Heini PF, Suhm N, Gisep A. The effect of pulsed jet lavage in vertebroplasty on injection forces of polymethylmethacrylate bone cement, material distribution, and potential fat embolism: a cadaver study. Spine (Phila Pa 1976). 2008;33(23):E906–10. Benneker LM, Heini PF, Suhm N, Gisep A. The effect of pulsed jet lavage in vertebroplasty on injection forces of polymethylmethacrylate bone cement, material distribution, and potential fat embolism: a cadaver study. Spine (Phila Pa 1976). 2008;33(23):E906–10.
7.
go back to reference Boger A, Benneker LM, Krebs J, Boner V, Heini PF, Gisep A. The effect of pulsed jet lavage in vertebroplasty on injection forces of PMMA bone cement: an animal study. Eur Spine J. 2009;18(12):1957–62.CrossRef Boger A, Benneker LM, Krebs J, Boner V, Heini PF, Gisep A. The effect of pulsed jet lavage in vertebroplasty on injection forces of PMMA bone cement: an animal study. Eur Spine J. 2009;18(12):1957–62.CrossRef
8.
go back to reference Benneker LM, Krebs J, Boner V, Boger A, Hoerstrup S, Heini PF, et al. Cardiovascular changes after PMMA vertebroplasty in sheep: the effect of bone marrow removal using pulsed jet-lavage. European Spine Journal. 2010;19(11):1913–20.CrossRef Benneker LM, Krebs J, Boner V, Boger A, Hoerstrup S, Heini PF, et al. Cardiovascular changes after PMMA vertebroplasty in sheep: the effect of bone marrow removal using pulsed jet-lavage. European Spine Journal. 2010;19(11):1913–20.CrossRef
9.
go back to reference Albers CE, Schott PM, Ahmad SS, Benneker LM, Nieuwkamp N, Hoppe S. Vertebral body lavage reduces hemodynamic response to vertebral body augmentation with PMMA. Global Spine Journal. 2018;9(5):499–504.CrossRef Albers CE, Schott PM, Ahmad SS, Benneker LM, Nieuwkamp N, Hoppe S. Vertebral body lavage reduces hemodynamic response to vertebral body augmentation with PMMA. Global Spine Journal. 2018;9(5):499–504.CrossRef
10.
go back to reference Hoppe S, Elfiky T, Keel MJ, Aghayev E, Ecker TM, Benneker LM. Lavage prior to vertebral augmentation reduces the risk for cement leakage. Eur Spine J. 2016;25(11):3463–9.CrossRef Hoppe S, Elfiky T, Keel MJ, Aghayev E, Ecker TM, Benneker LM. Lavage prior to vertebral augmentation reduces the risk for cement leakage. Eur Spine J. 2016;25(11):3463–9.CrossRef
11.
go back to reference Cheng X, Long H-Q, Xu J-H, Huang Y-L, Li F-B. Comparison of unilateral versus bilateral percutaneous kyphoplasty for the treatment of patients with osteoporosis vertebral compression fracture (OVCF): a systematic review and meta-analysis. European Spine Journal. 2016;25(11):3439–49.CrossRef Cheng X, Long H-Q, Xu J-H, Huang Y-L, Li F-B. Comparison of unilateral versus bilateral percutaneous kyphoplasty for the treatment of patients with osteoporosis vertebral compression fracture (OVCF): a systematic review and meta-analysis. European Spine Journal. 2016;25(11):3439–49.CrossRef
12.
go back to reference Sun H, Li C. Comparison of unilateral and bilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a systematic review and meta-analysis, Journal of Orthopaedic Surgery and Research. 2016;11(1):156. Sun H, Li C. Comparison of unilateral and bilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a systematic review and meta-analysis, Journal of Orthopaedic Surgery and Research. 2016;11(1):156.
13.
go back to reference Zhang LG, Gu X, Zhang HL, Zhang QG, Cai XB, Tao K. Unilateral or bilateral percutaneous vertebroplasty for acute osteoporotic vertebral fracture: a prospective study. J Spinal Disord Tech. 2015;28(2):E85–8.CrossRef Zhang LG, Gu X, Zhang HL, Zhang QG, Cai XB, Tao K. Unilateral or bilateral percutaneous vertebroplasty for acute osteoporotic vertebral fracture: a prospective study. J Spinal Disord Tech. 2015;28(2):E85–8.CrossRef
14.
go back to reference Yan L, He B, Guo H, Liu T, Hao D. The prospective self-controlled study of unilateral transverse process-pedicle and bilateral puncture techniques in percutaneous kyphoplasty, Osteoporosis International. 2015;27(5):1849–55. Yan L, He B, Guo H, Liu T, Hao D. The prospective self-controlled study of unilateral transverse process-pedicle and bilateral puncture techniques in percutaneous kyphoplasty, Osteoporosis International. 2015;27(5):1849–55.
15.
go back to reference Chen C, Bian J, Zhang W, Zhang W, Zhao C, Wei H. Unilateral versus bilateral vertebroplasty for severe osteoporotic vertebral compression fractures. J Spinal Disord Tech. 2014;27(8):E301–4.CrossRef Chen C, Bian J, Zhang W, Zhang W, Zhao C, Wei H. Unilateral versus bilateral vertebroplasty for severe osteoporotic vertebral compression fractures. J Spinal Disord Tech. 2014;27(8):E301–4.CrossRef
16.
go back to reference Zhao C, Sun Y, Jiang W, Cory E, Caffrey JP, Hsu FH, et al. Pulsed lavage cleansing of osteochondral grafts depends on lavage duration, flow intensity, and graft storage condition. Plos One. 2017;12(5):e0176934.CrossRef Zhao C, Sun Y, Jiang W, Cory E, Caffrey JP, Hsu FH, et al. Pulsed lavage cleansing of osteochondral grafts depends on lavage duration, flow intensity, and graft storage condition. Plos One. 2017;12(5):e0176934.CrossRef
17.
go back to reference Mohamed R, Silbermann C, Ahmari A, Bohner M, Becker S, Baroud G. Cement filling control and bone marrow removal in vertebral body augmentation by unipedicular aspiration technique: an experimental study using leakage model. Spine (Phila Pa 1976). 2010;35(3):353–60.CrossRef Mohamed R, Silbermann C, Ahmari A, Bohner M, Becker S, Baroud G. Cement filling control and bone marrow removal in vertebral body augmentation by unipedicular aspiration technique: an experimental study using leakage model. Spine (Phila Pa 1976). 2010;35(3):353–60.CrossRef
18.
go back to reference Hershkovich O, Lucantoni C, Kapoor S, Boszczyk B. Bone marrow washout for multilevel vertebroplasty in multiple myeloma spinal involvement. Technical note. European Spine Journal. 2018;28(6):1455–60.CrossRef Hershkovich O, Lucantoni C, Kapoor S, Boszczyk B. Bone marrow washout for multilevel vertebroplasty in multiple myeloma spinal involvement. Technical note. European Spine Journal. 2018;28(6):1455–60.CrossRef
19.
go back to reference Li K, Yan J, Yang Q, Li Z, Li J. The effect of void creation prior to vertebroplasty on intravertebral pressure and cement distribution in cadaveric spines with simulated metastases. Journal of Orthopaedic Surgery and Research. 2015;10(1):20.CrossRef Li K, Yan J, Yang Q, Li Z, Li J. The effect of void creation prior to vertebroplasty on intravertebral pressure and cement distribution in cadaveric spines with simulated metastases. Journal of Orthopaedic Surgery and Research. 2015;10(1):20.CrossRef
Metadata
Title
Effect of unilateral pulsed jet lavage prior to vertebroplasty on the intravertebral pressure and cement distribution
Authors
Jun Yan
Qiaohui Liu
Yanping Zheng
Ziqun Liu
Xinyu Liu
Xun Guo
Penghui Liu
Peng Chen
Suomao Yuan
Yonghao Tian
Wanlong Xu
Publication date
01-12-2020
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2020
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-020-01779-3

Other articles of this Issue 1/2020

Journal of Orthopaedic Surgery and Research 1/2020 Go to the issue